Purification of liquid xenon with the spark discharge technique for use in two-phase emission detectors
Abstract A procedure for spark-discharge purification of a liquid xenon sample with a mass of 55 kg is described. The average lifetime of ionization electrons before capture by electronegative impurities in liquid xenon increased from ≤ 0.1 μs to ≥ 50 μs for an electric field of 50–500 V/cm as a res...
Ausführliche Beschreibung
Autor*in: |
Akimov, D. Yu. [verfasserIn] |
---|
Format: |
Artikel |
---|---|
Sprache: |
Englisch |
Erschienen: |
2017 |
---|
Anmerkung: |
© Pleiades Publishing, Inc. 2017 |
---|
Übergeordnetes Werk: |
Enthalten in: Instruments and experimental techniques - Pleiades Publishing, 1959, 60(2017), 6 vom: Nov., Seite 782-788 |
---|---|
Übergeordnetes Werk: |
volume:60 ; year:2017 ; number:6 ; month:11 ; pages:782-788 |
Links: |
---|
DOI / URN: |
10.1134/S002044121705013X |
---|
Katalog-ID: |
OLC2034159705 |
---|
LEADER | 01000caa a22002652 4500 | ||
---|---|---|---|
001 | OLC2034159705 | ||
003 | DE-627 | ||
005 | 20230503094510.0 | ||
007 | tu | ||
008 | 200819s2017 xx ||||| 00| ||eng c | ||
024 | 7 | |a 10.1134/S002044121705013X |2 doi | |
035 | |a (DE-627)OLC2034159705 | ||
035 | |a (DE-He213)S002044121705013X-p | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
082 | 0 | 4 | |a 620 |q VZ |
084 | |a 11 |2 ssgn | ||
100 | 1 | |a Akimov, D. Yu. |e verfasserin |4 aut | |
245 | 1 | 0 | |a Purification of liquid xenon with the spark discharge technique for use in two-phase emission detectors |
264 | 1 | |c 2017 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a ohne Hilfsmittel zu benutzen |b n |2 rdamedia | ||
338 | |a Band |b nc |2 rdacarrier | ||
500 | |a © Pleiades Publishing, Inc. 2017 | ||
520 | |a Abstract A procedure for spark-discharge purification of a liquid xenon sample with a mass of 55 kg is described. The average lifetime of ionization electrons before capture by electronegative impurities in liquid xenon increased from ≤ 0.1 μs to ≥ 50 μs for an electric field of 50–500 V/cm as a result of the procedure. The xenon purified with this method is intended for use in the RED-100 detector for observation of the process of coherent elastic neutrino scattering off xenon nuclei. | ||
700 | 1 | |a Belov, V. A. |4 aut | |
700 | 1 | |a Berdnikova, A. K. |4 aut | |
700 | 1 | |a Bobkov, S. V. |4 aut | |
700 | 1 | |a Bolozdynya, A. I. |4 aut | |
700 | 1 | |a Dolgolenko, A. G. |4 aut | |
700 | 1 | |a Dzhumaev, P. S. |4 aut | |
700 | 1 | |a Gusakov, Yu. V. |4 aut | |
700 | 1 | |a Guss, D. V. |4 aut | |
700 | 1 | |a Khromov, A. V. |4 aut | |
700 | 1 | |a Kolpakov, M. Yu. |4 aut | |
700 | 1 | |a Konovalov, A. M. |4 aut | |
700 | 1 | |a Kovalenko, A. G. |4 aut | |
700 | 1 | |a Kozlova, E. S. |4 aut | |
700 | 1 | |a Krakhmalova, T. D. |4 aut | |
700 | 1 | |a Kumpan, A. V. |4 aut | |
700 | 1 | |a Lukyashin, A. V. |4 aut | |
700 | 1 | |a Melikyan, Yu. A. |4 aut | |
700 | 1 | |a Nepochataya, O. E. |4 aut | |
700 | 1 | |a Rudik, D. G. |4 aut | |
700 | 1 | |a Savinov, M. Yu. |4 aut | |
700 | 1 | |a Shakirov, A. V. |4 aut | |
700 | 1 | |a Sidorenko, A. V. |4 aut | |
700 | 1 | |a Simakov, G. E. |4 aut | |
700 | 1 | |a Sosnovtsev, V. V. |4 aut | |
700 | 1 | |a Taer, G. S. |4 aut | |
773 | 0 | 8 | |i Enthalten in |t Instruments and experimental techniques |d Pleiades Publishing, 1959 |g 60(2017), 6 vom: Nov., Seite 782-788 |w (DE-627)129603007 |w (DE-600)241643-8 |w (DE-576)015096815 |x 0020-4412 |7 nnns |
773 | 1 | 8 | |g volume:60 |g year:2017 |g number:6 |g month:11 |g pages:782-788 |
856 | 4 | 1 | |u https://doi.org/10.1134/S002044121705013X |z lizenzpflichtig |3 Volltext |
912 | |a GBV_USEFLAG_A | ||
912 | |a SYSFLAG_A | ||
912 | |a GBV_OLC | ||
912 | |a SSG-OLC-TEC | ||
912 | |a SSG-OLC-PHY | ||
912 | |a GBV_ILN_70 | ||
951 | |a AR | ||
952 | |d 60 |j 2017 |e 6 |c 11 |h 782-788 |
author_variant |
d y a dy dya v a b va vab a k b ak akb s v b sv svb a i b ai aib a g d ag agd p s d ps psd y v g yv yvg d v g dv dvg a v k av avk m y k my myk a m k am amk a g k ag agk e s k es esk t d k td tdk a v k av avk a v l av avl y a m ya yam o e n oe oen d g r dg dgr m y s my mys a v s av avs a v s av avs g e s ge ges v v s vv vvs g s t gs gst |
---|---|
matchkey_str |
article:00204412:2017----::uiiainfiudeowtteprdshreehiufrsito |
hierarchy_sort_str |
2017 |
publishDate |
2017 |
allfields |
10.1134/S002044121705013X doi (DE-627)OLC2034159705 (DE-He213)S002044121705013X-p DE-627 ger DE-627 rakwb eng 620 VZ 11 ssgn Akimov, D. Yu. verfasserin aut Purification of liquid xenon with the spark discharge technique for use in two-phase emission detectors 2017 Text txt rdacontent ohne Hilfsmittel zu benutzen n rdamedia Band nc rdacarrier © Pleiades Publishing, Inc. 2017 Abstract A procedure for spark-discharge purification of a liquid xenon sample with a mass of 55 kg is described. The average lifetime of ionization electrons before capture by electronegative impurities in liquid xenon increased from ≤ 0.1 μs to ≥ 50 μs for an electric field of 50–500 V/cm as a result of the procedure. The xenon purified with this method is intended for use in the RED-100 detector for observation of the process of coherent elastic neutrino scattering off xenon nuclei. Belov, V. A. aut Berdnikova, A. K. aut Bobkov, S. V. aut Bolozdynya, A. I. aut Dolgolenko, A. G. aut Dzhumaev, P. S. aut Gusakov, Yu. V. aut Guss, D. V. aut Khromov, A. V. aut Kolpakov, M. Yu. aut Konovalov, A. M. aut Kovalenko, A. G. aut Kozlova, E. S. aut Krakhmalova, T. D. aut Kumpan, A. V. aut Lukyashin, A. V. aut Melikyan, Yu. A. aut Nepochataya, O. E. aut Rudik, D. G. aut Savinov, M. Yu. aut Shakirov, A. V. aut Sidorenko, A. V. aut Simakov, G. E. aut Sosnovtsev, V. V. aut Taer, G. S. aut Enthalten in Instruments and experimental techniques Pleiades Publishing, 1959 60(2017), 6 vom: Nov., Seite 782-788 (DE-627)129603007 (DE-600)241643-8 (DE-576)015096815 0020-4412 nnns volume:60 year:2017 number:6 month:11 pages:782-788 https://doi.org/10.1134/S002044121705013X lizenzpflichtig Volltext GBV_USEFLAG_A SYSFLAG_A GBV_OLC SSG-OLC-TEC SSG-OLC-PHY GBV_ILN_70 AR 60 2017 6 11 782-788 |
spelling |
10.1134/S002044121705013X doi (DE-627)OLC2034159705 (DE-He213)S002044121705013X-p DE-627 ger DE-627 rakwb eng 620 VZ 11 ssgn Akimov, D. Yu. verfasserin aut Purification of liquid xenon with the spark discharge technique for use in two-phase emission detectors 2017 Text txt rdacontent ohne Hilfsmittel zu benutzen n rdamedia Band nc rdacarrier © Pleiades Publishing, Inc. 2017 Abstract A procedure for spark-discharge purification of a liquid xenon sample with a mass of 55 kg is described. The average lifetime of ionization electrons before capture by electronegative impurities in liquid xenon increased from ≤ 0.1 μs to ≥ 50 μs for an electric field of 50–500 V/cm as a result of the procedure. The xenon purified with this method is intended for use in the RED-100 detector for observation of the process of coherent elastic neutrino scattering off xenon nuclei. Belov, V. A. aut Berdnikova, A. K. aut Bobkov, S. V. aut Bolozdynya, A. I. aut Dolgolenko, A. G. aut Dzhumaev, P. S. aut Gusakov, Yu. V. aut Guss, D. V. aut Khromov, A. V. aut Kolpakov, M. Yu. aut Konovalov, A. M. aut Kovalenko, A. G. aut Kozlova, E. S. aut Krakhmalova, T. D. aut Kumpan, A. V. aut Lukyashin, A. V. aut Melikyan, Yu. A. aut Nepochataya, O. E. aut Rudik, D. G. aut Savinov, M. Yu. aut Shakirov, A. V. aut Sidorenko, A. V. aut Simakov, G. E. aut Sosnovtsev, V. V. aut Taer, G. S. aut Enthalten in Instruments and experimental techniques Pleiades Publishing, 1959 60(2017), 6 vom: Nov., Seite 782-788 (DE-627)129603007 (DE-600)241643-8 (DE-576)015096815 0020-4412 nnns volume:60 year:2017 number:6 month:11 pages:782-788 https://doi.org/10.1134/S002044121705013X lizenzpflichtig Volltext GBV_USEFLAG_A SYSFLAG_A GBV_OLC SSG-OLC-TEC SSG-OLC-PHY GBV_ILN_70 AR 60 2017 6 11 782-788 |
allfields_unstemmed |
10.1134/S002044121705013X doi (DE-627)OLC2034159705 (DE-He213)S002044121705013X-p DE-627 ger DE-627 rakwb eng 620 VZ 11 ssgn Akimov, D. Yu. verfasserin aut Purification of liquid xenon with the spark discharge technique for use in two-phase emission detectors 2017 Text txt rdacontent ohne Hilfsmittel zu benutzen n rdamedia Band nc rdacarrier © Pleiades Publishing, Inc. 2017 Abstract A procedure for spark-discharge purification of a liquid xenon sample with a mass of 55 kg is described. The average lifetime of ionization electrons before capture by electronegative impurities in liquid xenon increased from ≤ 0.1 μs to ≥ 50 μs for an electric field of 50–500 V/cm as a result of the procedure. The xenon purified with this method is intended for use in the RED-100 detector for observation of the process of coherent elastic neutrino scattering off xenon nuclei. Belov, V. A. aut Berdnikova, A. K. aut Bobkov, S. V. aut Bolozdynya, A. I. aut Dolgolenko, A. G. aut Dzhumaev, P. S. aut Gusakov, Yu. V. aut Guss, D. V. aut Khromov, A. V. aut Kolpakov, M. Yu. aut Konovalov, A. M. aut Kovalenko, A. G. aut Kozlova, E. S. aut Krakhmalova, T. D. aut Kumpan, A. V. aut Lukyashin, A. V. aut Melikyan, Yu. A. aut Nepochataya, O. E. aut Rudik, D. G. aut Savinov, M. Yu. aut Shakirov, A. V. aut Sidorenko, A. V. aut Simakov, G. E. aut Sosnovtsev, V. V. aut Taer, G. S. aut Enthalten in Instruments and experimental techniques Pleiades Publishing, 1959 60(2017), 6 vom: Nov., Seite 782-788 (DE-627)129603007 (DE-600)241643-8 (DE-576)015096815 0020-4412 nnns volume:60 year:2017 number:6 month:11 pages:782-788 https://doi.org/10.1134/S002044121705013X lizenzpflichtig Volltext GBV_USEFLAG_A SYSFLAG_A GBV_OLC SSG-OLC-TEC SSG-OLC-PHY GBV_ILN_70 AR 60 2017 6 11 782-788 |
allfieldsGer |
10.1134/S002044121705013X doi (DE-627)OLC2034159705 (DE-He213)S002044121705013X-p DE-627 ger DE-627 rakwb eng 620 VZ 11 ssgn Akimov, D. Yu. verfasserin aut Purification of liquid xenon with the spark discharge technique for use in two-phase emission detectors 2017 Text txt rdacontent ohne Hilfsmittel zu benutzen n rdamedia Band nc rdacarrier © Pleiades Publishing, Inc. 2017 Abstract A procedure for spark-discharge purification of a liquid xenon sample with a mass of 55 kg is described. The average lifetime of ionization electrons before capture by electronegative impurities in liquid xenon increased from ≤ 0.1 μs to ≥ 50 μs for an electric field of 50–500 V/cm as a result of the procedure. The xenon purified with this method is intended for use in the RED-100 detector for observation of the process of coherent elastic neutrino scattering off xenon nuclei. Belov, V. A. aut Berdnikova, A. K. aut Bobkov, S. V. aut Bolozdynya, A. I. aut Dolgolenko, A. G. aut Dzhumaev, P. S. aut Gusakov, Yu. V. aut Guss, D. V. aut Khromov, A. V. aut Kolpakov, M. Yu. aut Konovalov, A. M. aut Kovalenko, A. G. aut Kozlova, E. S. aut Krakhmalova, T. D. aut Kumpan, A. V. aut Lukyashin, A. V. aut Melikyan, Yu. A. aut Nepochataya, O. E. aut Rudik, D. G. aut Savinov, M. Yu. aut Shakirov, A. V. aut Sidorenko, A. V. aut Simakov, G. E. aut Sosnovtsev, V. V. aut Taer, G. S. aut Enthalten in Instruments and experimental techniques Pleiades Publishing, 1959 60(2017), 6 vom: Nov., Seite 782-788 (DE-627)129603007 (DE-600)241643-8 (DE-576)015096815 0020-4412 nnns volume:60 year:2017 number:6 month:11 pages:782-788 https://doi.org/10.1134/S002044121705013X lizenzpflichtig Volltext GBV_USEFLAG_A SYSFLAG_A GBV_OLC SSG-OLC-TEC SSG-OLC-PHY GBV_ILN_70 AR 60 2017 6 11 782-788 |
allfieldsSound |
10.1134/S002044121705013X doi (DE-627)OLC2034159705 (DE-He213)S002044121705013X-p DE-627 ger DE-627 rakwb eng 620 VZ 11 ssgn Akimov, D. Yu. verfasserin aut Purification of liquid xenon with the spark discharge technique for use in two-phase emission detectors 2017 Text txt rdacontent ohne Hilfsmittel zu benutzen n rdamedia Band nc rdacarrier © Pleiades Publishing, Inc. 2017 Abstract A procedure for spark-discharge purification of a liquid xenon sample with a mass of 55 kg is described. The average lifetime of ionization electrons before capture by electronegative impurities in liquid xenon increased from ≤ 0.1 μs to ≥ 50 μs for an electric field of 50–500 V/cm as a result of the procedure. The xenon purified with this method is intended for use in the RED-100 detector for observation of the process of coherent elastic neutrino scattering off xenon nuclei. Belov, V. A. aut Berdnikova, A. K. aut Bobkov, S. V. aut Bolozdynya, A. I. aut Dolgolenko, A. G. aut Dzhumaev, P. S. aut Gusakov, Yu. V. aut Guss, D. V. aut Khromov, A. V. aut Kolpakov, M. Yu. aut Konovalov, A. M. aut Kovalenko, A. G. aut Kozlova, E. S. aut Krakhmalova, T. D. aut Kumpan, A. V. aut Lukyashin, A. V. aut Melikyan, Yu. A. aut Nepochataya, O. E. aut Rudik, D. G. aut Savinov, M. Yu. aut Shakirov, A. V. aut Sidorenko, A. V. aut Simakov, G. E. aut Sosnovtsev, V. V. aut Taer, G. S. aut Enthalten in Instruments and experimental techniques Pleiades Publishing, 1959 60(2017), 6 vom: Nov., Seite 782-788 (DE-627)129603007 (DE-600)241643-8 (DE-576)015096815 0020-4412 nnns volume:60 year:2017 number:6 month:11 pages:782-788 https://doi.org/10.1134/S002044121705013X lizenzpflichtig Volltext GBV_USEFLAG_A SYSFLAG_A GBV_OLC SSG-OLC-TEC SSG-OLC-PHY GBV_ILN_70 AR 60 2017 6 11 782-788 |
language |
English |
source |
Enthalten in Instruments and experimental techniques 60(2017), 6 vom: Nov., Seite 782-788 volume:60 year:2017 number:6 month:11 pages:782-788 |
sourceStr |
Enthalten in Instruments and experimental techniques 60(2017), 6 vom: Nov., Seite 782-788 volume:60 year:2017 number:6 month:11 pages:782-788 |
format_phy_str_mv |
Article |
institution |
findex.gbv.de |
dewey-raw |
620 |
isfreeaccess_bool |
false |
container_title |
Instruments and experimental techniques |
authorswithroles_txt_mv |
Akimov, D. Yu. @@aut@@ Belov, V. A. @@aut@@ Berdnikova, A. K. @@aut@@ Bobkov, S. V. @@aut@@ Bolozdynya, A. I. @@aut@@ Dolgolenko, A. G. @@aut@@ Dzhumaev, P. S. @@aut@@ Gusakov, Yu. V. @@aut@@ Guss, D. V. @@aut@@ Khromov, A. V. @@aut@@ Kolpakov, M. Yu. @@aut@@ Konovalov, A. M. @@aut@@ Kovalenko, A. G. @@aut@@ Kozlova, E. S. @@aut@@ Krakhmalova, T. D. @@aut@@ Kumpan, A. V. @@aut@@ Lukyashin, A. V. @@aut@@ Melikyan, Yu. A. @@aut@@ Nepochataya, O. E. @@aut@@ Rudik, D. G. @@aut@@ Savinov, M. Yu. @@aut@@ Shakirov, A. V. @@aut@@ Sidorenko, A. V. @@aut@@ Simakov, G. E. @@aut@@ Sosnovtsev, V. V. @@aut@@ Taer, G. S. @@aut@@ |
publishDateDaySort_date |
2017-11-01T00:00:00Z |
hierarchy_top_id |
129603007 |
dewey-sort |
3620 |
id |
OLC2034159705 |
language_de |
englisch |
fullrecord |
<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim"><record><leader>01000caa a22002652 4500</leader><controlfield tag="001">OLC2034159705</controlfield><controlfield tag="003">DE-627</controlfield><controlfield tag="005">20230503094510.0</controlfield><controlfield tag="007">tu</controlfield><controlfield tag="008">200819s2017 xx ||||| 00| ||eng c</controlfield><datafield tag="024" ind1="7" ind2=" "><subfield code="a">10.1134/S002044121705013X</subfield><subfield code="2">doi</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-627)OLC2034159705</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-He213)S002044121705013X-p</subfield></datafield><datafield tag="040" ind1=" " ind2=" "><subfield code="a">DE-627</subfield><subfield code="b">ger</subfield><subfield code="c">DE-627</subfield><subfield code="e">rakwb</subfield></datafield><datafield tag="041" ind1=" " ind2=" "><subfield code="a">eng</subfield></datafield><datafield tag="082" ind1="0" ind2="4"><subfield code="a">620</subfield><subfield code="q">VZ</subfield></datafield><datafield tag="084" ind1=" " ind2=" "><subfield code="a">11</subfield><subfield code="2">ssgn</subfield></datafield><datafield tag="100" ind1="1" ind2=" "><subfield code="a">Akimov, D. Yu.</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="245" ind1="1" ind2="0"><subfield code="a">Purification of liquid xenon with the spark discharge technique for use in two-phase emission detectors</subfield></datafield><datafield tag="264" ind1=" " ind2="1"><subfield code="c">2017</subfield></datafield><datafield tag="336" ind1=" " ind2=" "><subfield code="a">Text</subfield><subfield code="b">txt</subfield><subfield code="2">rdacontent</subfield></datafield><datafield tag="337" ind1=" " ind2=" "><subfield code="a">ohne Hilfsmittel zu benutzen</subfield><subfield code="b">n</subfield><subfield code="2">rdamedia</subfield></datafield><datafield tag="338" ind1=" " ind2=" "><subfield code="a">Band</subfield><subfield code="b">nc</subfield><subfield code="2">rdacarrier</subfield></datafield><datafield tag="500" ind1=" " ind2=" "><subfield code="a">© Pleiades Publishing, Inc. 2017</subfield></datafield><datafield tag="520" ind1=" " ind2=" "><subfield code="a">Abstract A procedure for spark-discharge purification of a liquid xenon sample with a mass of 55 kg is described. The average lifetime of ionization electrons before capture by electronegative impurities in liquid xenon increased from ≤ 0.1 μs to ≥ 50 μs for an electric field of 50–500 V/cm as a result of the procedure. The xenon purified with this method is intended for use in the RED-100 detector for observation of the process of coherent elastic neutrino scattering off xenon nuclei.</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Belov, V. A.</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Berdnikova, A. K.</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Bobkov, S. V.</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Bolozdynya, A. I.</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Dolgolenko, A. G.</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Dzhumaev, P. S.</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Gusakov, Yu. V.</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Guss, D. V.</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Khromov, A. V.</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Kolpakov, M. Yu.</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Konovalov, A. M.</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Kovalenko, A. G.</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Kozlova, E. S.</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Krakhmalova, T. D.</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Kumpan, A. V.</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Lukyashin, A. V.</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Melikyan, Yu. A.</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Nepochataya, O. E.</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Rudik, D. G.</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Savinov, M. Yu.</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Shakirov, A. V.</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Sidorenko, A. V.</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Simakov, G. E.</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Sosnovtsev, V. V.</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Taer, G. S.</subfield><subfield code="4">aut</subfield></datafield><datafield tag="773" ind1="0" ind2="8"><subfield code="i">Enthalten in</subfield><subfield code="t">Instruments and experimental techniques</subfield><subfield code="d">Pleiades Publishing, 1959</subfield><subfield code="g">60(2017), 6 vom: Nov., Seite 782-788</subfield><subfield code="w">(DE-627)129603007</subfield><subfield code="w">(DE-600)241643-8</subfield><subfield code="w">(DE-576)015096815</subfield><subfield code="x">0020-4412</subfield><subfield code="7">nnns</subfield></datafield><datafield tag="773" ind1="1" ind2="8"><subfield code="g">volume:60</subfield><subfield code="g">year:2017</subfield><subfield code="g">number:6</subfield><subfield code="g">month:11</subfield><subfield code="g">pages:782-788</subfield></datafield><datafield tag="856" ind1="4" ind2="1"><subfield code="u">https://doi.org/10.1134/S002044121705013X</subfield><subfield code="z">lizenzpflichtig</subfield><subfield code="3">Volltext</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_USEFLAG_A</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">SYSFLAG_A</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_OLC</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">SSG-OLC-TEC</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">SSG-OLC-PHY</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_70</subfield></datafield><datafield tag="951" ind1=" " ind2=" "><subfield code="a">AR</subfield></datafield><datafield tag="952" ind1=" " ind2=" "><subfield code="d">60</subfield><subfield code="j">2017</subfield><subfield code="e">6</subfield><subfield code="c">11</subfield><subfield code="h">782-788</subfield></datafield></record></collection>
|
author |
Akimov, D. Yu. |
spellingShingle |
Akimov, D. Yu. ddc 620 ssgn 11 Purification of liquid xenon with the spark discharge technique for use in two-phase emission detectors |
authorStr |
Akimov, D. Yu. |
ppnlink_with_tag_str_mv |
@@773@@(DE-627)129603007 |
format |
Article |
dewey-ones |
620 - Engineering & allied operations |
delete_txt_mv |
keep |
author_role |
aut aut aut aut aut aut aut aut aut aut aut aut aut aut aut aut aut aut aut aut aut aut aut aut aut aut |
collection |
OLC |
remote_str |
false |
illustrated |
Not Illustrated |
issn |
0020-4412 |
topic_title |
620 VZ 11 ssgn Purification of liquid xenon with the spark discharge technique for use in two-phase emission detectors |
topic |
ddc 620 ssgn 11 |
topic_unstemmed |
ddc 620 ssgn 11 |
topic_browse |
ddc 620 ssgn 11 |
format_facet |
Aufsätze Gedruckte Aufsätze |
format_main_str_mv |
Text Zeitschrift/Artikel |
carriertype_str_mv |
nc |
hierarchy_parent_title |
Instruments and experimental techniques |
hierarchy_parent_id |
129603007 |
dewey-tens |
620 - Engineering |
hierarchy_top_title |
Instruments and experimental techniques |
isfreeaccess_txt |
false |
familylinks_str_mv |
(DE-627)129603007 (DE-600)241643-8 (DE-576)015096815 |
title |
Purification of liquid xenon with the spark discharge technique for use in two-phase emission detectors |
ctrlnum |
(DE-627)OLC2034159705 (DE-He213)S002044121705013X-p |
title_full |
Purification of liquid xenon with the spark discharge technique for use in two-phase emission detectors |
author_sort |
Akimov, D. Yu. |
journal |
Instruments and experimental techniques |
journalStr |
Instruments and experimental techniques |
lang_code |
eng |
isOA_bool |
false |
dewey-hundreds |
600 - Technology |
recordtype |
marc |
publishDateSort |
2017 |
contenttype_str_mv |
txt |
container_start_page |
782 |
author_browse |
Akimov, D. Yu. Belov, V. A. Berdnikova, A. K. Bobkov, S. V. Bolozdynya, A. I. Dolgolenko, A. G. Dzhumaev, P. S. Gusakov, Yu. V. Guss, D. V. Khromov, A. V. Kolpakov, M. Yu. Konovalov, A. M. Kovalenko, A. G. Kozlova, E. S. Krakhmalova, T. D. Kumpan, A. V. Lukyashin, A. V. Melikyan, Yu. A. Nepochataya, O. E. Rudik, D. G. Savinov, M. Yu. Shakirov, A. V. Sidorenko, A. V. Simakov, G. E. Sosnovtsev, V. V. Taer, G. S. |
container_volume |
60 |
class |
620 VZ 11 ssgn |
format_se |
Aufsätze |
author-letter |
Akimov, D. Yu. |
doi_str_mv |
10.1134/S002044121705013X |
dewey-full |
620 |
title_sort |
purification of liquid xenon with the spark discharge technique for use in two-phase emission detectors |
title_auth |
Purification of liquid xenon with the spark discharge technique for use in two-phase emission detectors |
abstract |
Abstract A procedure for spark-discharge purification of a liquid xenon sample with a mass of 55 kg is described. The average lifetime of ionization electrons before capture by electronegative impurities in liquid xenon increased from ≤ 0.1 μs to ≥ 50 μs for an electric field of 50–500 V/cm as a result of the procedure. The xenon purified with this method is intended for use in the RED-100 detector for observation of the process of coherent elastic neutrino scattering off xenon nuclei. © Pleiades Publishing, Inc. 2017 |
abstractGer |
Abstract A procedure for spark-discharge purification of a liquid xenon sample with a mass of 55 kg is described. The average lifetime of ionization electrons before capture by electronegative impurities in liquid xenon increased from ≤ 0.1 μs to ≥ 50 μs for an electric field of 50–500 V/cm as a result of the procedure. The xenon purified with this method is intended for use in the RED-100 detector for observation of the process of coherent elastic neutrino scattering off xenon nuclei. © Pleiades Publishing, Inc. 2017 |
abstract_unstemmed |
Abstract A procedure for spark-discharge purification of a liquid xenon sample with a mass of 55 kg is described. The average lifetime of ionization electrons before capture by electronegative impurities in liquid xenon increased from ≤ 0.1 μs to ≥ 50 μs for an electric field of 50–500 V/cm as a result of the procedure. The xenon purified with this method is intended for use in the RED-100 detector for observation of the process of coherent elastic neutrino scattering off xenon nuclei. © Pleiades Publishing, Inc. 2017 |
collection_details |
GBV_USEFLAG_A SYSFLAG_A GBV_OLC SSG-OLC-TEC SSG-OLC-PHY GBV_ILN_70 |
container_issue |
6 |
title_short |
Purification of liquid xenon with the spark discharge technique for use in two-phase emission detectors |
url |
https://doi.org/10.1134/S002044121705013X |
remote_bool |
false |
author2 |
Belov, V. A. Berdnikova, A. K. Bobkov, S. V. Bolozdynya, A. I. Dolgolenko, A. G. Dzhumaev, P. S. Gusakov, Yu. V. Guss, D. V. Khromov, A. V. Kolpakov, M. Yu Konovalov, A. M. Kovalenko, A. G. Kozlova, E. S. Krakhmalova, T. D. Kumpan, A. V. Lukyashin, A. V. Melikyan, Yu. A. Nepochataya, O. E. Rudik, D. G. Savinov, M. Yu Shakirov, A. V. Sidorenko, A. V. Simakov, G. E. Sosnovtsev, V. V. Taer, G. S. |
author2Str |
Belov, V. A. Berdnikova, A. K. Bobkov, S. V. Bolozdynya, A. I. Dolgolenko, A. G. Dzhumaev, P. S. Gusakov, Yu. V. Guss, D. V. Khromov, A. V. Kolpakov, M. Yu Konovalov, A. M. Kovalenko, A. G. Kozlova, E. S. Krakhmalova, T. D. Kumpan, A. V. Lukyashin, A. V. Melikyan, Yu. A. Nepochataya, O. E. Rudik, D. G. Savinov, M. Yu Shakirov, A. V. Sidorenko, A. V. Simakov, G. E. Sosnovtsev, V. V. Taer, G. S. |
ppnlink |
129603007 |
mediatype_str_mv |
n |
isOA_txt |
false |
hochschulschrift_bool |
false |
doi_str |
10.1134/S002044121705013X |
up_date |
2024-07-03T19:51:49.324Z |
_version_ |
1803588793095159808 |
fullrecord_marcxml |
<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim"><record><leader>01000caa a22002652 4500</leader><controlfield tag="001">OLC2034159705</controlfield><controlfield tag="003">DE-627</controlfield><controlfield tag="005">20230503094510.0</controlfield><controlfield tag="007">tu</controlfield><controlfield tag="008">200819s2017 xx ||||| 00| ||eng c</controlfield><datafield tag="024" ind1="7" ind2=" "><subfield code="a">10.1134/S002044121705013X</subfield><subfield code="2">doi</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-627)OLC2034159705</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-He213)S002044121705013X-p</subfield></datafield><datafield tag="040" ind1=" " ind2=" "><subfield code="a">DE-627</subfield><subfield code="b">ger</subfield><subfield code="c">DE-627</subfield><subfield code="e">rakwb</subfield></datafield><datafield tag="041" ind1=" " ind2=" "><subfield code="a">eng</subfield></datafield><datafield tag="082" ind1="0" ind2="4"><subfield code="a">620</subfield><subfield code="q">VZ</subfield></datafield><datafield tag="084" ind1=" " ind2=" "><subfield code="a">11</subfield><subfield code="2">ssgn</subfield></datafield><datafield tag="100" ind1="1" ind2=" "><subfield code="a">Akimov, D. Yu.</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="245" ind1="1" ind2="0"><subfield code="a">Purification of liquid xenon with the spark discharge technique for use in two-phase emission detectors</subfield></datafield><datafield tag="264" ind1=" " ind2="1"><subfield code="c">2017</subfield></datafield><datafield tag="336" ind1=" " ind2=" "><subfield code="a">Text</subfield><subfield code="b">txt</subfield><subfield code="2">rdacontent</subfield></datafield><datafield tag="337" ind1=" " ind2=" "><subfield code="a">ohne Hilfsmittel zu benutzen</subfield><subfield code="b">n</subfield><subfield code="2">rdamedia</subfield></datafield><datafield tag="338" ind1=" " ind2=" "><subfield code="a">Band</subfield><subfield code="b">nc</subfield><subfield code="2">rdacarrier</subfield></datafield><datafield tag="500" ind1=" " ind2=" "><subfield code="a">© Pleiades Publishing, Inc. 2017</subfield></datafield><datafield tag="520" ind1=" " ind2=" "><subfield code="a">Abstract A procedure for spark-discharge purification of a liquid xenon sample with a mass of 55 kg is described. The average lifetime of ionization electrons before capture by electronegative impurities in liquid xenon increased from ≤ 0.1 μs to ≥ 50 μs for an electric field of 50–500 V/cm as a result of the procedure. The xenon purified with this method is intended for use in the RED-100 detector for observation of the process of coherent elastic neutrino scattering off xenon nuclei.</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Belov, V. A.</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Berdnikova, A. K.</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Bobkov, S. V.</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Bolozdynya, A. I.</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Dolgolenko, A. G.</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Dzhumaev, P. S.</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Gusakov, Yu. V.</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Guss, D. V.</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Khromov, A. V.</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Kolpakov, M. Yu.</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Konovalov, A. M.</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Kovalenko, A. G.</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Kozlova, E. S.</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Krakhmalova, T. D.</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Kumpan, A. V.</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Lukyashin, A. V.</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Melikyan, Yu. A.</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Nepochataya, O. E.</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Rudik, D. G.</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Savinov, M. Yu.</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Shakirov, A. V.</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Sidorenko, A. V.</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Simakov, G. E.</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Sosnovtsev, V. V.</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Taer, G. S.</subfield><subfield code="4">aut</subfield></datafield><datafield tag="773" ind1="0" ind2="8"><subfield code="i">Enthalten in</subfield><subfield code="t">Instruments and experimental techniques</subfield><subfield code="d">Pleiades Publishing, 1959</subfield><subfield code="g">60(2017), 6 vom: Nov., Seite 782-788</subfield><subfield code="w">(DE-627)129603007</subfield><subfield code="w">(DE-600)241643-8</subfield><subfield code="w">(DE-576)015096815</subfield><subfield code="x">0020-4412</subfield><subfield code="7">nnns</subfield></datafield><datafield tag="773" ind1="1" ind2="8"><subfield code="g">volume:60</subfield><subfield code="g">year:2017</subfield><subfield code="g">number:6</subfield><subfield code="g">month:11</subfield><subfield code="g">pages:782-788</subfield></datafield><datafield tag="856" ind1="4" ind2="1"><subfield code="u">https://doi.org/10.1134/S002044121705013X</subfield><subfield code="z">lizenzpflichtig</subfield><subfield code="3">Volltext</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_USEFLAG_A</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">SYSFLAG_A</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_OLC</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">SSG-OLC-TEC</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">SSG-OLC-PHY</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_70</subfield></datafield><datafield tag="951" ind1=" " ind2=" "><subfield code="a">AR</subfield></datafield><datafield tag="952" ind1=" " ind2=" "><subfield code="d">60</subfield><subfield code="j">2017</subfield><subfield code="e">6</subfield><subfield code="c">11</subfield><subfield code="h">782-788</subfield></datafield></record></collection>
|
score |
7.4007416 |