A combined cryostat/oven and specimen transfer device for tensile testing in the range 83 to 473° K
Abstract Design details and performance of a combined cryostat and oven for an Instron TT-CM universal testing machine are described. The cryostat is suitable for tensile testing in the range 83 to 473° K and has a test chamber 5.5 in. × 5.5 in. and 20 in. deep which could be used for testing specim...
Ausführliche Beschreibung
Autor*in: |
Reed, P. E. [verfasserIn] |
---|
Format: |
Artikel |
---|---|
Sprache: |
Englisch |
Erschienen: |
1966 |
---|
Schlagwörter: |
---|
Anmerkung: |
© Chapman and Hall 1966 |
---|
Übergeordnetes Werk: |
Enthalten in: Journal of materials science - Kluwer Academic Publishers, 1966, 1(1966), 1 vom: Feb., Seite 91-95 |
---|---|
Übergeordnetes Werk: |
volume:1 ; year:1966 ; number:1 ; month:02 ; pages:91-95 |
Links: |
---|
DOI / URN: |
10.1007/BF00549723 |
---|
Katalog-ID: |
OLC2046068831 |
---|
LEADER | 01000caa a22002652 4500 | ||
---|---|---|---|
001 | OLC2046068831 | ||
003 | DE-627 | ||
005 | 20230503120816.0 | ||
007 | tu | ||
008 | 200820s1966 xx ||||| 00| ||eng c | ||
024 | 7 | |a 10.1007/BF00549723 |2 doi | |
035 | |a (DE-627)OLC2046068831 | ||
035 | |a (DE-He213)BF00549723-p | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
082 | 0 | 4 | |a 670 |q VZ |
100 | 1 | |a Reed, P. E. |e verfasserin |4 aut | |
245 | 1 | 0 | |a A combined cryostat/oven and specimen transfer device for tensile testing in the range 83 to 473° K |
264 | 1 | |c 1966 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a ohne Hilfsmittel zu benutzen |b n |2 rdamedia | ||
338 | |a Band |b nc |2 rdacarrier | ||
500 | |a © Chapman and Hall 1966 | ||
520 | |a Abstract Design details and performance of a combined cryostat and oven for an Instron TT-CM universal testing machine are described. The cryostat is suitable for tensile testing in the range 83 to 473° K and has a test chamber 5.5 in. × 5.5 in. and 20 in. deep which could be used for testing specimens 7 in. wide. Special attention is drawn to the ease of specimen insertion which may be performed while the cryostat is cold. The temperature within the test chamber is controlled, by admitting dry air, to ± 1 ° C of any desired test temperature for periods of at least 20 min. A specimen transfer device is also described for transferring a pretreated specimen at −26° C to the cryostat with a temperature rise of less than 1 ° C. The transfer device provides a method of rapid specimen insertion once the cryostat is cold. | ||
650 | 4 | |a Polymer | |
650 | 4 | |a Tensile Testing | |
650 | 4 | |a Temperature Rise | |
650 | 4 | |a Testing Specimen | |
650 | 4 | |a Testing Machine | |
773 | 0 | 8 | |i Enthalten in |t Journal of materials science |d Kluwer Academic Publishers, 1966 |g 1(1966), 1 vom: Feb., Seite 91-95 |w (DE-627)129546372 |w (DE-600)218324-9 |w (DE-576)014996774 |x 0022-2461 |7 nnns |
773 | 1 | 8 | |g volume:1 |g year:1966 |g number:1 |g month:02 |g pages:91-95 |
856 | 4 | 1 | |u https://doi.org/10.1007/BF00549723 |z lizenzpflichtig |3 Volltext |
912 | |a GBV_USEFLAG_A | ||
912 | |a SYSFLAG_A | ||
912 | |a GBV_OLC | ||
912 | |a SSG-OLC-TEC | ||
912 | |a GBV_ILN_20 | ||
912 | |a GBV_ILN_30 | ||
912 | |a GBV_ILN_62 | ||
912 | |a GBV_ILN_65 | ||
912 | |a GBV_ILN_70 | ||
912 | |a GBV_ILN_170 | ||
912 | |a GBV_ILN_2006 | ||
912 | |a GBV_ILN_2015 | ||
912 | |a GBV_ILN_2020 | ||
912 | |a GBV_ILN_2021 | ||
912 | |a GBV_ILN_2027 | ||
912 | |a GBV_ILN_2242 | ||
912 | |a GBV_ILN_4309 | ||
912 | |a GBV_ILN_4319 | ||
951 | |a AR | ||
952 | |d 1 |j 1966 |e 1 |c 02 |h 91-95 |
author_variant |
p e r pe per |
---|---|
matchkey_str |
article:00222461:1966----::cmiecysaoeadpcmnrnfreieotnieet |
hierarchy_sort_str |
1966 |
publishDate |
1966 |
allfields |
10.1007/BF00549723 doi (DE-627)OLC2046068831 (DE-He213)BF00549723-p DE-627 ger DE-627 rakwb eng 670 VZ Reed, P. E. verfasserin aut A combined cryostat/oven and specimen transfer device for tensile testing in the range 83 to 473° K 1966 Text txt rdacontent ohne Hilfsmittel zu benutzen n rdamedia Band nc rdacarrier © Chapman and Hall 1966 Abstract Design details and performance of a combined cryostat and oven for an Instron TT-CM universal testing machine are described. The cryostat is suitable for tensile testing in the range 83 to 473° K and has a test chamber 5.5 in. × 5.5 in. and 20 in. deep which could be used for testing specimens 7 in. wide. Special attention is drawn to the ease of specimen insertion which may be performed while the cryostat is cold. The temperature within the test chamber is controlled, by admitting dry air, to ± 1 ° C of any desired test temperature for periods of at least 20 min. A specimen transfer device is also described for transferring a pretreated specimen at −26° C to the cryostat with a temperature rise of less than 1 ° C. The transfer device provides a method of rapid specimen insertion once the cryostat is cold. Polymer Tensile Testing Temperature Rise Testing Specimen Testing Machine Enthalten in Journal of materials science Kluwer Academic Publishers, 1966 1(1966), 1 vom: Feb., Seite 91-95 (DE-627)129546372 (DE-600)218324-9 (DE-576)014996774 0022-2461 nnns volume:1 year:1966 number:1 month:02 pages:91-95 https://doi.org/10.1007/BF00549723 lizenzpflichtig Volltext GBV_USEFLAG_A SYSFLAG_A GBV_OLC SSG-OLC-TEC GBV_ILN_20 GBV_ILN_30 GBV_ILN_62 GBV_ILN_65 GBV_ILN_70 GBV_ILN_170 GBV_ILN_2006 GBV_ILN_2015 GBV_ILN_2020 GBV_ILN_2021 GBV_ILN_2027 GBV_ILN_2242 GBV_ILN_4309 GBV_ILN_4319 AR 1 1966 1 02 91-95 |
spelling |
10.1007/BF00549723 doi (DE-627)OLC2046068831 (DE-He213)BF00549723-p DE-627 ger DE-627 rakwb eng 670 VZ Reed, P. E. verfasserin aut A combined cryostat/oven and specimen transfer device for tensile testing in the range 83 to 473° K 1966 Text txt rdacontent ohne Hilfsmittel zu benutzen n rdamedia Band nc rdacarrier © Chapman and Hall 1966 Abstract Design details and performance of a combined cryostat and oven for an Instron TT-CM universal testing machine are described. The cryostat is suitable for tensile testing in the range 83 to 473° K and has a test chamber 5.5 in. × 5.5 in. and 20 in. deep which could be used for testing specimens 7 in. wide. Special attention is drawn to the ease of specimen insertion which may be performed while the cryostat is cold. The temperature within the test chamber is controlled, by admitting dry air, to ± 1 ° C of any desired test temperature for periods of at least 20 min. A specimen transfer device is also described for transferring a pretreated specimen at −26° C to the cryostat with a temperature rise of less than 1 ° C. The transfer device provides a method of rapid specimen insertion once the cryostat is cold. Polymer Tensile Testing Temperature Rise Testing Specimen Testing Machine Enthalten in Journal of materials science Kluwer Academic Publishers, 1966 1(1966), 1 vom: Feb., Seite 91-95 (DE-627)129546372 (DE-600)218324-9 (DE-576)014996774 0022-2461 nnns volume:1 year:1966 number:1 month:02 pages:91-95 https://doi.org/10.1007/BF00549723 lizenzpflichtig Volltext GBV_USEFLAG_A SYSFLAG_A GBV_OLC SSG-OLC-TEC GBV_ILN_20 GBV_ILN_30 GBV_ILN_62 GBV_ILN_65 GBV_ILN_70 GBV_ILN_170 GBV_ILN_2006 GBV_ILN_2015 GBV_ILN_2020 GBV_ILN_2021 GBV_ILN_2027 GBV_ILN_2242 GBV_ILN_4309 GBV_ILN_4319 AR 1 1966 1 02 91-95 |
allfields_unstemmed |
10.1007/BF00549723 doi (DE-627)OLC2046068831 (DE-He213)BF00549723-p DE-627 ger DE-627 rakwb eng 670 VZ Reed, P. E. verfasserin aut A combined cryostat/oven and specimen transfer device for tensile testing in the range 83 to 473° K 1966 Text txt rdacontent ohne Hilfsmittel zu benutzen n rdamedia Band nc rdacarrier © Chapman and Hall 1966 Abstract Design details and performance of a combined cryostat and oven for an Instron TT-CM universal testing machine are described. The cryostat is suitable for tensile testing in the range 83 to 473° K and has a test chamber 5.5 in. × 5.5 in. and 20 in. deep which could be used for testing specimens 7 in. wide. Special attention is drawn to the ease of specimen insertion which may be performed while the cryostat is cold. The temperature within the test chamber is controlled, by admitting dry air, to ± 1 ° C of any desired test temperature for periods of at least 20 min. A specimen transfer device is also described for transferring a pretreated specimen at −26° C to the cryostat with a temperature rise of less than 1 ° C. The transfer device provides a method of rapid specimen insertion once the cryostat is cold. Polymer Tensile Testing Temperature Rise Testing Specimen Testing Machine Enthalten in Journal of materials science Kluwer Academic Publishers, 1966 1(1966), 1 vom: Feb., Seite 91-95 (DE-627)129546372 (DE-600)218324-9 (DE-576)014996774 0022-2461 nnns volume:1 year:1966 number:1 month:02 pages:91-95 https://doi.org/10.1007/BF00549723 lizenzpflichtig Volltext GBV_USEFLAG_A SYSFLAG_A GBV_OLC SSG-OLC-TEC GBV_ILN_20 GBV_ILN_30 GBV_ILN_62 GBV_ILN_65 GBV_ILN_70 GBV_ILN_170 GBV_ILN_2006 GBV_ILN_2015 GBV_ILN_2020 GBV_ILN_2021 GBV_ILN_2027 GBV_ILN_2242 GBV_ILN_4309 GBV_ILN_4319 AR 1 1966 1 02 91-95 |
allfieldsGer |
10.1007/BF00549723 doi (DE-627)OLC2046068831 (DE-He213)BF00549723-p DE-627 ger DE-627 rakwb eng 670 VZ Reed, P. E. verfasserin aut A combined cryostat/oven and specimen transfer device for tensile testing in the range 83 to 473° K 1966 Text txt rdacontent ohne Hilfsmittel zu benutzen n rdamedia Band nc rdacarrier © Chapman and Hall 1966 Abstract Design details and performance of a combined cryostat and oven for an Instron TT-CM universal testing machine are described. The cryostat is suitable for tensile testing in the range 83 to 473° K and has a test chamber 5.5 in. × 5.5 in. and 20 in. deep which could be used for testing specimens 7 in. wide. Special attention is drawn to the ease of specimen insertion which may be performed while the cryostat is cold. The temperature within the test chamber is controlled, by admitting dry air, to ± 1 ° C of any desired test temperature for periods of at least 20 min. A specimen transfer device is also described for transferring a pretreated specimen at −26° C to the cryostat with a temperature rise of less than 1 ° C. The transfer device provides a method of rapid specimen insertion once the cryostat is cold. Polymer Tensile Testing Temperature Rise Testing Specimen Testing Machine Enthalten in Journal of materials science Kluwer Academic Publishers, 1966 1(1966), 1 vom: Feb., Seite 91-95 (DE-627)129546372 (DE-600)218324-9 (DE-576)014996774 0022-2461 nnns volume:1 year:1966 number:1 month:02 pages:91-95 https://doi.org/10.1007/BF00549723 lizenzpflichtig Volltext GBV_USEFLAG_A SYSFLAG_A GBV_OLC SSG-OLC-TEC GBV_ILN_20 GBV_ILN_30 GBV_ILN_62 GBV_ILN_65 GBV_ILN_70 GBV_ILN_170 GBV_ILN_2006 GBV_ILN_2015 GBV_ILN_2020 GBV_ILN_2021 GBV_ILN_2027 GBV_ILN_2242 GBV_ILN_4309 GBV_ILN_4319 AR 1 1966 1 02 91-95 |
allfieldsSound |
10.1007/BF00549723 doi (DE-627)OLC2046068831 (DE-He213)BF00549723-p DE-627 ger DE-627 rakwb eng 670 VZ Reed, P. E. verfasserin aut A combined cryostat/oven and specimen transfer device for tensile testing in the range 83 to 473° K 1966 Text txt rdacontent ohne Hilfsmittel zu benutzen n rdamedia Band nc rdacarrier © Chapman and Hall 1966 Abstract Design details and performance of a combined cryostat and oven for an Instron TT-CM universal testing machine are described. The cryostat is suitable for tensile testing in the range 83 to 473° K and has a test chamber 5.5 in. × 5.5 in. and 20 in. deep which could be used for testing specimens 7 in. wide. Special attention is drawn to the ease of specimen insertion which may be performed while the cryostat is cold. The temperature within the test chamber is controlled, by admitting dry air, to ± 1 ° C of any desired test temperature for periods of at least 20 min. A specimen transfer device is also described for transferring a pretreated specimen at −26° C to the cryostat with a temperature rise of less than 1 ° C. The transfer device provides a method of rapid specimen insertion once the cryostat is cold. Polymer Tensile Testing Temperature Rise Testing Specimen Testing Machine Enthalten in Journal of materials science Kluwer Academic Publishers, 1966 1(1966), 1 vom: Feb., Seite 91-95 (DE-627)129546372 (DE-600)218324-9 (DE-576)014996774 0022-2461 nnns volume:1 year:1966 number:1 month:02 pages:91-95 https://doi.org/10.1007/BF00549723 lizenzpflichtig Volltext GBV_USEFLAG_A SYSFLAG_A GBV_OLC SSG-OLC-TEC GBV_ILN_20 GBV_ILN_30 GBV_ILN_62 GBV_ILN_65 GBV_ILN_70 GBV_ILN_170 GBV_ILN_2006 GBV_ILN_2015 GBV_ILN_2020 GBV_ILN_2021 GBV_ILN_2027 GBV_ILN_2242 GBV_ILN_4309 GBV_ILN_4319 AR 1 1966 1 02 91-95 |
language |
English |
source |
Enthalten in Journal of materials science 1(1966), 1 vom: Feb., Seite 91-95 volume:1 year:1966 number:1 month:02 pages:91-95 |
sourceStr |
Enthalten in Journal of materials science 1(1966), 1 vom: Feb., Seite 91-95 volume:1 year:1966 number:1 month:02 pages:91-95 |
format_phy_str_mv |
Article |
institution |
findex.gbv.de |
topic_facet |
Polymer Tensile Testing Temperature Rise Testing Specimen Testing Machine |
dewey-raw |
670 |
isfreeaccess_bool |
false |
container_title |
Journal of materials science |
authorswithroles_txt_mv |
Reed, P. E. @@aut@@ |
publishDateDaySort_date |
1966-02-01T00:00:00Z |
hierarchy_top_id |
129546372 |
dewey-sort |
3670 |
id |
OLC2046068831 |
language_de |
englisch |
fullrecord |
<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim"><record><leader>01000caa a22002652 4500</leader><controlfield tag="001">OLC2046068831</controlfield><controlfield tag="003">DE-627</controlfield><controlfield tag="005">20230503120816.0</controlfield><controlfield tag="007">tu</controlfield><controlfield tag="008">200820s1966 xx ||||| 00| ||eng c</controlfield><datafield tag="024" ind1="7" ind2=" "><subfield code="a">10.1007/BF00549723</subfield><subfield code="2">doi</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-627)OLC2046068831</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-He213)BF00549723-p</subfield></datafield><datafield tag="040" ind1=" " ind2=" "><subfield code="a">DE-627</subfield><subfield code="b">ger</subfield><subfield code="c">DE-627</subfield><subfield code="e">rakwb</subfield></datafield><datafield tag="041" ind1=" " ind2=" "><subfield code="a">eng</subfield></datafield><datafield tag="082" ind1="0" ind2="4"><subfield code="a">670</subfield><subfield code="q">VZ</subfield></datafield><datafield tag="100" ind1="1" ind2=" "><subfield code="a">Reed, P. E.</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="245" ind1="1" ind2="0"><subfield code="a">A combined cryostat/oven and specimen transfer device for tensile testing in the range 83 to 473° K</subfield></datafield><datafield tag="264" ind1=" " ind2="1"><subfield code="c">1966</subfield></datafield><datafield tag="336" ind1=" " ind2=" "><subfield code="a">Text</subfield><subfield code="b">txt</subfield><subfield code="2">rdacontent</subfield></datafield><datafield tag="337" ind1=" " ind2=" "><subfield code="a">ohne Hilfsmittel zu benutzen</subfield><subfield code="b">n</subfield><subfield code="2">rdamedia</subfield></datafield><datafield tag="338" ind1=" " ind2=" "><subfield code="a">Band</subfield><subfield code="b">nc</subfield><subfield code="2">rdacarrier</subfield></datafield><datafield tag="500" ind1=" " ind2=" "><subfield code="a">© Chapman and Hall 1966</subfield></datafield><datafield tag="520" ind1=" " ind2=" "><subfield code="a">Abstract Design details and performance of a combined cryostat and oven for an Instron TT-CM universal testing machine are described. The cryostat is suitable for tensile testing in the range 83 to 473° K and has a test chamber 5.5 in. × 5.5 in. and 20 in. deep which could be used for testing specimens 7 in. wide. Special attention is drawn to the ease of specimen insertion which may be performed while the cryostat is cold. The temperature within the test chamber is controlled, by admitting dry air, to ± 1 ° C of any desired test temperature for periods of at least 20 min. A specimen transfer device is also described for transferring a pretreated specimen at −26° C to the cryostat with a temperature rise of less than 1 ° C. The transfer device provides a method of rapid specimen insertion once the cryostat is cold.</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Polymer</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Tensile Testing</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Temperature Rise</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Testing Specimen</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Testing Machine</subfield></datafield><datafield tag="773" ind1="0" ind2="8"><subfield code="i">Enthalten in</subfield><subfield code="t">Journal of materials science</subfield><subfield code="d">Kluwer Academic Publishers, 1966</subfield><subfield code="g">1(1966), 1 vom: Feb., Seite 91-95</subfield><subfield code="w">(DE-627)129546372</subfield><subfield code="w">(DE-600)218324-9</subfield><subfield code="w">(DE-576)014996774</subfield><subfield code="x">0022-2461</subfield><subfield code="7">nnns</subfield></datafield><datafield tag="773" ind1="1" ind2="8"><subfield code="g">volume:1</subfield><subfield code="g">year:1966</subfield><subfield code="g">number:1</subfield><subfield code="g">month:02</subfield><subfield code="g">pages:91-95</subfield></datafield><datafield tag="856" ind1="4" ind2="1"><subfield code="u">https://doi.org/10.1007/BF00549723</subfield><subfield code="z">lizenzpflichtig</subfield><subfield code="3">Volltext</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_USEFLAG_A</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">SYSFLAG_A</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_OLC</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">SSG-OLC-TEC</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_20</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_30</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_62</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_65</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_70</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_170</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2006</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2015</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2020</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2021</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2027</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2242</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4309</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4319</subfield></datafield><datafield tag="951" ind1=" " ind2=" "><subfield code="a">AR</subfield></datafield><datafield tag="952" ind1=" " ind2=" "><subfield code="d">1</subfield><subfield code="j">1966</subfield><subfield code="e">1</subfield><subfield code="c">02</subfield><subfield code="h">91-95</subfield></datafield></record></collection>
|
author |
Reed, P. E. |
spellingShingle |
Reed, P. E. ddc 670 misc Polymer misc Tensile Testing misc Temperature Rise misc Testing Specimen misc Testing Machine A combined cryostat/oven and specimen transfer device for tensile testing in the range 83 to 473° K |
authorStr |
Reed, P. E. |
ppnlink_with_tag_str_mv |
@@773@@(DE-627)129546372 |
format |
Article |
dewey-ones |
670 - Manufacturing |
delete_txt_mv |
keep |
author_role |
aut |
collection |
OLC |
remote_str |
false |
illustrated |
Not Illustrated |
issn |
0022-2461 |
topic_title |
670 VZ A combined cryostat/oven and specimen transfer device for tensile testing in the range 83 to 473° K Polymer Tensile Testing Temperature Rise Testing Specimen Testing Machine |
topic |
ddc 670 misc Polymer misc Tensile Testing misc Temperature Rise misc Testing Specimen misc Testing Machine |
topic_unstemmed |
ddc 670 misc Polymer misc Tensile Testing misc Temperature Rise misc Testing Specimen misc Testing Machine |
topic_browse |
ddc 670 misc Polymer misc Tensile Testing misc Temperature Rise misc Testing Specimen misc Testing Machine |
format_facet |
Aufsätze Gedruckte Aufsätze |
format_main_str_mv |
Text Zeitschrift/Artikel |
carriertype_str_mv |
nc |
hierarchy_parent_title |
Journal of materials science |
hierarchy_parent_id |
129546372 |
dewey-tens |
670 - Manufacturing |
hierarchy_top_title |
Journal of materials science |
isfreeaccess_txt |
false |
familylinks_str_mv |
(DE-627)129546372 (DE-600)218324-9 (DE-576)014996774 |
title |
A combined cryostat/oven and specimen transfer device for tensile testing in the range 83 to 473° K |
ctrlnum |
(DE-627)OLC2046068831 (DE-He213)BF00549723-p |
title_full |
A combined cryostat/oven and specimen transfer device for tensile testing in the range 83 to 473° K |
author_sort |
Reed, P. E. |
journal |
Journal of materials science |
journalStr |
Journal of materials science |
lang_code |
eng |
isOA_bool |
false |
dewey-hundreds |
600 - Technology |
recordtype |
marc |
publishDateSort |
1966 |
contenttype_str_mv |
txt |
container_start_page |
91 |
author_browse |
Reed, P. E. |
container_volume |
1 |
class |
670 VZ |
format_se |
Aufsätze |
author-letter |
Reed, P. E. |
doi_str_mv |
10.1007/BF00549723 |
dewey-full |
670 |
title_sort |
a combined cryostat/oven and specimen transfer device for tensile testing in the range 83 to 473° k |
title_auth |
A combined cryostat/oven and specimen transfer device for tensile testing in the range 83 to 473° K |
abstract |
Abstract Design details and performance of a combined cryostat and oven for an Instron TT-CM universal testing machine are described. The cryostat is suitable for tensile testing in the range 83 to 473° K and has a test chamber 5.5 in. × 5.5 in. and 20 in. deep which could be used for testing specimens 7 in. wide. Special attention is drawn to the ease of specimen insertion which may be performed while the cryostat is cold. The temperature within the test chamber is controlled, by admitting dry air, to ± 1 ° C of any desired test temperature for periods of at least 20 min. A specimen transfer device is also described for transferring a pretreated specimen at −26° C to the cryostat with a temperature rise of less than 1 ° C. The transfer device provides a method of rapid specimen insertion once the cryostat is cold. © Chapman and Hall 1966 |
abstractGer |
Abstract Design details and performance of a combined cryostat and oven for an Instron TT-CM universal testing machine are described. The cryostat is suitable for tensile testing in the range 83 to 473° K and has a test chamber 5.5 in. × 5.5 in. and 20 in. deep which could be used for testing specimens 7 in. wide. Special attention is drawn to the ease of specimen insertion which may be performed while the cryostat is cold. The temperature within the test chamber is controlled, by admitting dry air, to ± 1 ° C of any desired test temperature for periods of at least 20 min. A specimen transfer device is also described for transferring a pretreated specimen at −26° C to the cryostat with a temperature rise of less than 1 ° C. The transfer device provides a method of rapid specimen insertion once the cryostat is cold. © Chapman and Hall 1966 |
abstract_unstemmed |
Abstract Design details and performance of a combined cryostat and oven for an Instron TT-CM universal testing machine are described. The cryostat is suitable for tensile testing in the range 83 to 473° K and has a test chamber 5.5 in. × 5.5 in. and 20 in. deep which could be used for testing specimens 7 in. wide. Special attention is drawn to the ease of specimen insertion which may be performed while the cryostat is cold. The temperature within the test chamber is controlled, by admitting dry air, to ± 1 ° C of any desired test temperature for periods of at least 20 min. A specimen transfer device is also described for transferring a pretreated specimen at −26° C to the cryostat with a temperature rise of less than 1 ° C. The transfer device provides a method of rapid specimen insertion once the cryostat is cold. © Chapman and Hall 1966 |
collection_details |
GBV_USEFLAG_A SYSFLAG_A GBV_OLC SSG-OLC-TEC GBV_ILN_20 GBV_ILN_30 GBV_ILN_62 GBV_ILN_65 GBV_ILN_70 GBV_ILN_170 GBV_ILN_2006 GBV_ILN_2015 GBV_ILN_2020 GBV_ILN_2021 GBV_ILN_2027 GBV_ILN_2242 GBV_ILN_4309 GBV_ILN_4319 |
container_issue |
1 |
title_short |
A combined cryostat/oven and specimen transfer device for tensile testing in the range 83 to 473° K |
url |
https://doi.org/10.1007/BF00549723 |
remote_bool |
false |
ppnlink |
129546372 |
mediatype_str_mv |
n |
isOA_txt |
false |
hochschulschrift_bool |
false |
doi_str |
10.1007/BF00549723 |
up_date |
2024-07-04T04:11:46.213Z |
_version_ |
1803620247104651264 |
fullrecord_marcxml |
<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim"><record><leader>01000caa a22002652 4500</leader><controlfield tag="001">OLC2046068831</controlfield><controlfield tag="003">DE-627</controlfield><controlfield tag="005">20230503120816.0</controlfield><controlfield tag="007">tu</controlfield><controlfield tag="008">200820s1966 xx ||||| 00| ||eng c</controlfield><datafield tag="024" ind1="7" ind2=" "><subfield code="a">10.1007/BF00549723</subfield><subfield code="2">doi</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-627)OLC2046068831</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-He213)BF00549723-p</subfield></datafield><datafield tag="040" ind1=" " ind2=" "><subfield code="a">DE-627</subfield><subfield code="b">ger</subfield><subfield code="c">DE-627</subfield><subfield code="e">rakwb</subfield></datafield><datafield tag="041" ind1=" " ind2=" "><subfield code="a">eng</subfield></datafield><datafield tag="082" ind1="0" ind2="4"><subfield code="a">670</subfield><subfield code="q">VZ</subfield></datafield><datafield tag="100" ind1="1" ind2=" "><subfield code="a">Reed, P. E.</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="245" ind1="1" ind2="0"><subfield code="a">A combined cryostat/oven and specimen transfer device for tensile testing in the range 83 to 473° K</subfield></datafield><datafield tag="264" ind1=" " ind2="1"><subfield code="c">1966</subfield></datafield><datafield tag="336" ind1=" " ind2=" "><subfield code="a">Text</subfield><subfield code="b">txt</subfield><subfield code="2">rdacontent</subfield></datafield><datafield tag="337" ind1=" " ind2=" "><subfield code="a">ohne Hilfsmittel zu benutzen</subfield><subfield code="b">n</subfield><subfield code="2">rdamedia</subfield></datafield><datafield tag="338" ind1=" " ind2=" "><subfield code="a">Band</subfield><subfield code="b">nc</subfield><subfield code="2">rdacarrier</subfield></datafield><datafield tag="500" ind1=" " ind2=" "><subfield code="a">© Chapman and Hall 1966</subfield></datafield><datafield tag="520" ind1=" " ind2=" "><subfield code="a">Abstract Design details and performance of a combined cryostat and oven for an Instron TT-CM universal testing machine are described. The cryostat is suitable for tensile testing in the range 83 to 473° K and has a test chamber 5.5 in. × 5.5 in. and 20 in. deep which could be used for testing specimens 7 in. wide. Special attention is drawn to the ease of specimen insertion which may be performed while the cryostat is cold. The temperature within the test chamber is controlled, by admitting dry air, to ± 1 ° C of any desired test temperature for periods of at least 20 min. A specimen transfer device is also described for transferring a pretreated specimen at −26° C to the cryostat with a temperature rise of less than 1 ° C. The transfer device provides a method of rapid specimen insertion once the cryostat is cold.</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Polymer</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Tensile Testing</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Temperature Rise</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Testing Specimen</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Testing Machine</subfield></datafield><datafield tag="773" ind1="0" ind2="8"><subfield code="i">Enthalten in</subfield><subfield code="t">Journal of materials science</subfield><subfield code="d">Kluwer Academic Publishers, 1966</subfield><subfield code="g">1(1966), 1 vom: Feb., Seite 91-95</subfield><subfield code="w">(DE-627)129546372</subfield><subfield code="w">(DE-600)218324-9</subfield><subfield code="w">(DE-576)014996774</subfield><subfield code="x">0022-2461</subfield><subfield code="7">nnns</subfield></datafield><datafield tag="773" ind1="1" ind2="8"><subfield code="g">volume:1</subfield><subfield code="g">year:1966</subfield><subfield code="g">number:1</subfield><subfield code="g">month:02</subfield><subfield code="g">pages:91-95</subfield></datafield><datafield tag="856" ind1="4" ind2="1"><subfield code="u">https://doi.org/10.1007/BF00549723</subfield><subfield code="z">lizenzpflichtig</subfield><subfield code="3">Volltext</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_USEFLAG_A</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">SYSFLAG_A</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_OLC</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">SSG-OLC-TEC</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_20</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_30</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_62</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_65</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_70</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_170</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2006</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2015</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2020</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2021</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2027</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2242</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4309</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4319</subfield></datafield><datafield tag="951" ind1=" " ind2=" "><subfield code="a">AR</subfield></datafield><datafield tag="952" ind1=" " ind2=" "><subfield code="d">1</subfield><subfield code="j">1966</subfield><subfield code="e">1</subfield><subfield code="c">02</subfield><subfield code="h">91-95</subfield></datafield></record></collection>
|
score |
7.401121 |