The best fitting distribution of annual maximum rainfall in Peninsular Malaysia based on methods of L-moment and LQ-moment
Abstract The main objective of this study is to determine the best fitting distribution to describe the annual series of maximum daily rainfall from 1975 to 2004 for 50 rain gauge stations in Peninsular Malaysia based on L-moment and LQ-moment. Five three-parameter extreme-value distributions which...
Ausführliche Beschreibung
Autor*in: |
Wan Zin, Wan Zawiah [verfasserIn] |
---|
Format: |
Artikel |
---|---|
Sprache: |
Englisch |
Erschienen: |
2008 |
---|
Schlagwörter: |
---|
Systematik: |
|
---|
Anmerkung: |
© Springer-Verlag 2008 |
---|
Übergeordnetes Werk: |
Enthalten in: Theoretical and applied climatology - Springer Vienna, 1986, 96(2008), 3-4 vom: 17. Juli, Seite 337-344 |
---|---|
Übergeordnetes Werk: |
volume:96 ; year:2008 ; number:3-4 ; day:17 ; month:07 ; pages:337-344 |
Links: |
---|
DOI / URN: |
10.1007/s00704-008-0044-2 |
---|
Katalog-ID: |
OLC2048442439 |
---|
LEADER | 01000caa a22002652 4500 | ||
---|---|---|---|
001 | OLC2048442439 | ||
003 | DE-627 | ||
005 | 20230502135651.0 | ||
007 | tu | ||
008 | 200820s2008 xx ||||| 00| ||eng c | ||
024 | 7 | |a 10.1007/s00704-008-0044-2 |2 doi | |
035 | |a (DE-627)OLC2048442439 | ||
035 | |a (DE-He213)s00704-008-0044-2-p | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
082 | 0 | 4 | |a 550 |q VZ |
084 | |a 14 |2 ssgn | ||
084 | |a RA 1000 |q VZ |2 rvk | ||
100 | 1 | |a Wan Zin, Wan Zawiah |e verfasserin |4 aut | |
245 | 1 | 0 | |a The best fitting distribution of annual maximum rainfall in Peninsular Malaysia based on methods of L-moment and LQ-moment |
264 | 1 | |c 2008 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a ohne Hilfsmittel zu benutzen |b n |2 rdamedia | ||
338 | |a Band |b nc |2 rdacarrier | ||
500 | |a © Springer-Verlag 2008 | ||
520 | |a Abstract The main objective of this study is to determine the best fitting distribution to describe the annual series of maximum daily rainfall from 1975 to 2004 for 50 rain gauge stations in Peninsular Malaysia based on L-moment and LQ-moment. Five three-parameter extreme-value distributions which are considered are generalized extreme value (GEV), generalized Pareto (GP), generalized logistic (GL), lognormal (LN3) and Pearson (P3) distributions. The estimation of parameters of these distributions is determined using the L-moment and LQ-moment. The adequacy of the distributions based on parameter estimates computed using the two methods are evaluated using goodness-of-fit tests. When the goodness-of-fit results for these distributions are compared, it is found that, on the average, the performance of L-moment is better than the performance of LQ-moment. Although the best fitting distribution may vary according to the method of estimation and stations considered, in most cases, data for the majority of the stations are found to follow the generalized logistic distribution. | ||
650 | 4 | |a Malaysia | |
650 | 4 | |a Generalize Extreme Value | |
650 | 4 | |a Extreme Rainfall | |
650 | 4 | |a Generalize Extreme Value Distribution | |
650 | 4 | |a Extreme Rainfall Event | |
700 | 1 | |a Jemain, Abdul Aziz |4 aut | |
700 | 1 | |a Ibrahim, Kamarulzaman |4 aut | |
773 | 0 | 8 | |i Enthalten in |t Theoretical and applied climatology |d Springer Vienna, 1986 |g 96(2008), 3-4 vom: 17. Juli, Seite 337-344 |w (DE-627)129958808 |w (DE-600)405799-5 |w (DE-576)01552857X |x 0177-798X |7 nnns |
773 | 1 | 8 | |g volume:96 |g year:2008 |g number:3-4 |g day:17 |g month:07 |g pages:337-344 |
856 | 4 | 1 | |u https://doi.org/10.1007/s00704-008-0044-2 |z lizenzpflichtig |3 Volltext |
912 | |a GBV_USEFLAG_A | ||
912 | |a SYSFLAG_A | ||
912 | |a GBV_OLC | ||
912 | |a SSG-OLC-GEO | ||
912 | |a SSG-OPC-GGO | ||
912 | |a GBV_ILN_40 | ||
912 | |a GBV_ILN_70 | ||
912 | |a GBV_ILN_381 | ||
912 | |a GBV_ILN_2003 | ||
912 | |a GBV_ILN_2006 | ||
912 | |a GBV_ILN_4012 | ||
912 | |a GBV_ILN_4029 | ||
912 | |a GBV_ILN_4306 | ||
912 | |a GBV_ILN_4311 | ||
912 | |a GBV_ILN_4313 | ||
936 | r | v | |a RA 1000 |
951 | |a AR | ||
952 | |d 96 |j 2008 |e 3-4 |b 17 |c 07 |h 337-344 |
author_variant |
z w z w zwz zwzw a a j aa aaj k i ki |
---|---|
matchkey_str |
article:0177798X:2008----::hbsftigitiuinfnulaiuriflipnnuamlyibsd |
hierarchy_sort_str |
2008 |
publishDate |
2008 |
allfields |
10.1007/s00704-008-0044-2 doi (DE-627)OLC2048442439 (DE-He213)s00704-008-0044-2-p DE-627 ger DE-627 rakwb eng 550 VZ 14 ssgn RA 1000 VZ rvk Wan Zin, Wan Zawiah verfasserin aut The best fitting distribution of annual maximum rainfall in Peninsular Malaysia based on methods of L-moment and LQ-moment 2008 Text txt rdacontent ohne Hilfsmittel zu benutzen n rdamedia Band nc rdacarrier © Springer-Verlag 2008 Abstract The main objective of this study is to determine the best fitting distribution to describe the annual series of maximum daily rainfall from 1975 to 2004 for 50 rain gauge stations in Peninsular Malaysia based on L-moment and LQ-moment. Five three-parameter extreme-value distributions which are considered are generalized extreme value (GEV), generalized Pareto (GP), generalized logistic (GL), lognormal (LN3) and Pearson (P3) distributions. The estimation of parameters of these distributions is determined using the L-moment and LQ-moment. The adequacy of the distributions based on parameter estimates computed using the two methods are evaluated using goodness-of-fit tests. When the goodness-of-fit results for these distributions are compared, it is found that, on the average, the performance of L-moment is better than the performance of LQ-moment. Although the best fitting distribution may vary according to the method of estimation and stations considered, in most cases, data for the majority of the stations are found to follow the generalized logistic distribution. Malaysia Generalize Extreme Value Extreme Rainfall Generalize Extreme Value Distribution Extreme Rainfall Event Jemain, Abdul Aziz aut Ibrahim, Kamarulzaman aut Enthalten in Theoretical and applied climatology Springer Vienna, 1986 96(2008), 3-4 vom: 17. Juli, Seite 337-344 (DE-627)129958808 (DE-600)405799-5 (DE-576)01552857X 0177-798X nnns volume:96 year:2008 number:3-4 day:17 month:07 pages:337-344 https://doi.org/10.1007/s00704-008-0044-2 lizenzpflichtig Volltext GBV_USEFLAG_A SYSFLAG_A GBV_OLC SSG-OLC-GEO SSG-OPC-GGO GBV_ILN_40 GBV_ILN_70 GBV_ILN_381 GBV_ILN_2003 GBV_ILN_2006 GBV_ILN_4012 GBV_ILN_4029 GBV_ILN_4306 GBV_ILN_4311 GBV_ILN_4313 RA 1000 AR 96 2008 3-4 17 07 337-344 |
spelling |
10.1007/s00704-008-0044-2 doi (DE-627)OLC2048442439 (DE-He213)s00704-008-0044-2-p DE-627 ger DE-627 rakwb eng 550 VZ 14 ssgn RA 1000 VZ rvk Wan Zin, Wan Zawiah verfasserin aut The best fitting distribution of annual maximum rainfall in Peninsular Malaysia based on methods of L-moment and LQ-moment 2008 Text txt rdacontent ohne Hilfsmittel zu benutzen n rdamedia Band nc rdacarrier © Springer-Verlag 2008 Abstract The main objective of this study is to determine the best fitting distribution to describe the annual series of maximum daily rainfall from 1975 to 2004 for 50 rain gauge stations in Peninsular Malaysia based on L-moment and LQ-moment. Five three-parameter extreme-value distributions which are considered are generalized extreme value (GEV), generalized Pareto (GP), generalized logistic (GL), lognormal (LN3) and Pearson (P3) distributions. The estimation of parameters of these distributions is determined using the L-moment and LQ-moment. The adequacy of the distributions based on parameter estimates computed using the two methods are evaluated using goodness-of-fit tests. When the goodness-of-fit results for these distributions are compared, it is found that, on the average, the performance of L-moment is better than the performance of LQ-moment. Although the best fitting distribution may vary according to the method of estimation and stations considered, in most cases, data for the majority of the stations are found to follow the generalized logistic distribution. Malaysia Generalize Extreme Value Extreme Rainfall Generalize Extreme Value Distribution Extreme Rainfall Event Jemain, Abdul Aziz aut Ibrahim, Kamarulzaman aut Enthalten in Theoretical and applied climatology Springer Vienna, 1986 96(2008), 3-4 vom: 17. Juli, Seite 337-344 (DE-627)129958808 (DE-600)405799-5 (DE-576)01552857X 0177-798X nnns volume:96 year:2008 number:3-4 day:17 month:07 pages:337-344 https://doi.org/10.1007/s00704-008-0044-2 lizenzpflichtig Volltext GBV_USEFLAG_A SYSFLAG_A GBV_OLC SSG-OLC-GEO SSG-OPC-GGO GBV_ILN_40 GBV_ILN_70 GBV_ILN_381 GBV_ILN_2003 GBV_ILN_2006 GBV_ILN_4012 GBV_ILN_4029 GBV_ILN_4306 GBV_ILN_4311 GBV_ILN_4313 RA 1000 AR 96 2008 3-4 17 07 337-344 |
allfields_unstemmed |
10.1007/s00704-008-0044-2 doi (DE-627)OLC2048442439 (DE-He213)s00704-008-0044-2-p DE-627 ger DE-627 rakwb eng 550 VZ 14 ssgn RA 1000 VZ rvk Wan Zin, Wan Zawiah verfasserin aut The best fitting distribution of annual maximum rainfall in Peninsular Malaysia based on methods of L-moment and LQ-moment 2008 Text txt rdacontent ohne Hilfsmittel zu benutzen n rdamedia Band nc rdacarrier © Springer-Verlag 2008 Abstract The main objective of this study is to determine the best fitting distribution to describe the annual series of maximum daily rainfall from 1975 to 2004 for 50 rain gauge stations in Peninsular Malaysia based on L-moment and LQ-moment. Five three-parameter extreme-value distributions which are considered are generalized extreme value (GEV), generalized Pareto (GP), generalized logistic (GL), lognormal (LN3) and Pearson (P3) distributions. The estimation of parameters of these distributions is determined using the L-moment and LQ-moment. The adequacy of the distributions based on parameter estimates computed using the two methods are evaluated using goodness-of-fit tests. When the goodness-of-fit results for these distributions are compared, it is found that, on the average, the performance of L-moment is better than the performance of LQ-moment. Although the best fitting distribution may vary according to the method of estimation and stations considered, in most cases, data for the majority of the stations are found to follow the generalized logistic distribution. Malaysia Generalize Extreme Value Extreme Rainfall Generalize Extreme Value Distribution Extreme Rainfall Event Jemain, Abdul Aziz aut Ibrahim, Kamarulzaman aut Enthalten in Theoretical and applied climatology Springer Vienna, 1986 96(2008), 3-4 vom: 17. Juli, Seite 337-344 (DE-627)129958808 (DE-600)405799-5 (DE-576)01552857X 0177-798X nnns volume:96 year:2008 number:3-4 day:17 month:07 pages:337-344 https://doi.org/10.1007/s00704-008-0044-2 lizenzpflichtig Volltext GBV_USEFLAG_A SYSFLAG_A GBV_OLC SSG-OLC-GEO SSG-OPC-GGO GBV_ILN_40 GBV_ILN_70 GBV_ILN_381 GBV_ILN_2003 GBV_ILN_2006 GBV_ILN_4012 GBV_ILN_4029 GBV_ILN_4306 GBV_ILN_4311 GBV_ILN_4313 RA 1000 AR 96 2008 3-4 17 07 337-344 |
allfieldsGer |
10.1007/s00704-008-0044-2 doi (DE-627)OLC2048442439 (DE-He213)s00704-008-0044-2-p DE-627 ger DE-627 rakwb eng 550 VZ 14 ssgn RA 1000 VZ rvk Wan Zin, Wan Zawiah verfasserin aut The best fitting distribution of annual maximum rainfall in Peninsular Malaysia based on methods of L-moment and LQ-moment 2008 Text txt rdacontent ohne Hilfsmittel zu benutzen n rdamedia Band nc rdacarrier © Springer-Verlag 2008 Abstract The main objective of this study is to determine the best fitting distribution to describe the annual series of maximum daily rainfall from 1975 to 2004 for 50 rain gauge stations in Peninsular Malaysia based on L-moment and LQ-moment. Five three-parameter extreme-value distributions which are considered are generalized extreme value (GEV), generalized Pareto (GP), generalized logistic (GL), lognormal (LN3) and Pearson (P3) distributions. The estimation of parameters of these distributions is determined using the L-moment and LQ-moment. The adequacy of the distributions based on parameter estimates computed using the two methods are evaluated using goodness-of-fit tests. When the goodness-of-fit results for these distributions are compared, it is found that, on the average, the performance of L-moment is better than the performance of LQ-moment. Although the best fitting distribution may vary according to the method of estimation and stations considered, in most cases, data for the majority of the stations are found to follow the generalized logistic distribution. Malaysia Generalize Extreme Value Extreme Rainfall Generalize Extreme Value Distribution Extreme Rainfall Event Jemain, Abdul Aziz aut Ibrahim, Kamarulzaman aut Enthalten in Theoretical and applied climatology Springer Vienna, 1986 96(2008), 3-4 vom: 17. Juli, Seite 337-344 (DE-627)129958808 (DE-600)405799-5 (DE-576)01552857X 0177-798X nnns volume:96 year:2008 number:3-4 day:17 month:07 pages:337-344 https://doi.org/10.1007/s00704-008-0044-2 lizenzpflichtig Volltext GBV_USEFLAG_A SYSFLAG_A GBV_OLC SSG-OLC-GEO SSG-OPC-GGO GBV_ILN_40 GBV_ILN_70 GBV_ILN_381 GBV_ILN_2003 GBV_ILN_2006 GBV_ILN_4012 GBV_ILN_4029 GBV_ILN_4306 GBV_ILN_4311 GBV_ILN_4313 RA 1000 AR 96 2008 3-4 17 07 337-344 |
allfieldsSound |
10.1007/s00704-008-0044-2 doi (DE-627)OLC2048442439 (DE-He213)s00704-008-0044-2-p DE-627 ger DE-627 rakwb eng 550 VZ 14 ssgn RA 1000 VZ rvk Wan Zin, Wan Zawiah verfasserin aut The best fitting distribution of annual maximum rainfall in Peninsular Malaysia based on methods of L-moment and LQ-moment 2008 Text txt rdacontent ohne Hilfsmittel zu benutzen n rdamedia Band nc rdacarrier © Springer-Verlag 2008 Abstract The main objective of this study is to determine the best fitting distribution to describe the annual series of maximum daily rainfall from 1975 to 2004 for 50 rain gauge stations in Peninsular Malaysia based on L-moment and LQ-moment. Five three-parameter extreme-value distributions which are considered are generalized extreme value (GEV), generalized Pareto (GP), generalized logistic (GL), lognormal (LN3) and Pearson (P3) distributions. The estimation of parameters of these distributions is determined using the L-moment and LQ-moment. The adequacy of the distributions based on parameter estimates computed using the two methods are evaluated using goodness-of-fit tests. When the goodness-of-fit results for these distributions are compared, it is found that, on the average, the performance of L-moment is better than the performance of LQ-moment. Although the best fitting distribution may vary according to the method of estimation and stations considered, in most cases, data for the majority of the stations are found to follow the generalized logistic distribution. Malaysia Generalize Extreme Value Extreme Rainfall Generalize Extreme Value Distribution Extreme Rainfall Event Jemain, Abdul Aziz aut Ibrahim, Kamarulzaman aut Enthalten in Theoretical and applied climatology Springer Vienna, 1986 96(2008), 3-4 vom: 17. Juli, Seite 337-344 (DE-627)129958808 (DE-600)405799-5 (DE-576)01552857X 0177-798X nnns volume:96 year:2008 number:3-4 day:17 month:07 pages:337-344 https://doi.org/10.1007/s00704-008-0044-2 lizenzpflichtig Volltext GBV_USEFLAG_A SYSFLAG_A GBV_OLC SSG-OLC-GEO SSG-OPC-GGO GBV_ILN_40 GBV_ILN_70 GBV_ILN_381 GBV_ILN_2003 GBV_ILN_2006 GBV_ILN_4012 GBV_ILN_4029 GBV_ILN_4306 GBV_ILN_4311 GBV_ILN_4313 RA 1000 AR 96 2008 3-4 17 07 337-344 |
language |
English |
source |
Enthalten in Theoretical and applied climatology 96(2008), 3-4 vom: 17. Juli, Seite 337-344 volume:96 year:2008 number:3-4 day:17 month:07 pages:337-344 |
sourceStr |
Enthalten in Theoretical and applied climatology 96(2008), 3-4 vom: 17. Juli, Seite 337-344 volume:96 year:2008 number:3-4 day:17 month:07 pages:337-344 |
format_phy_str_mv |
Article |
institution |
findex.gbv.de |
topic_facet |
Malaysia Generalize Extreme Value Extreme Rainfall Generalize Extreme Value Distribution Extreme Rainfall Event |
dewey-raw |
550 |
isfreeaccess_bool |
false |
container_title |
Theoretical and applied climatology |
authorswithroles_txt_mv |
Wan Zin, Wan Zawiah @@aut@@ Jemain, Abdul Aziz @@aut@@ Ibrahim, Kamarulzaman @@aut@@ |
publishDateDaySort_date |
2008-07-17T00:00:00Z |
hierarchy_top_id |
129958808 |
dewey-sort |
3550 |
id |
OLC2048442439 |
language_de |
englisch |
fullrecord |
<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim"><record><leader>01000caa a22002652 4500</leader><controlfield tag="001">OLC2048442439</controlfield><controlfield tag="003">DE-627</controlfield><controlfield tag="005">20230502135651.0</controlfield><controlfield tag="007">tu</controlfield><controlfield tag="008">200820s2008 xx ||||| 00| ||eng c</controlfield><datafield tag="024" ind1="7" ind2=" "><subfield code="a">10.1007/s00704-008-0044-2</subfield><subfield code="2">doi</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-627)OLC2048442439</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-He213)s00704-008-0044-2-p</subfield></datafield><datafield tag="040" ind1=" " ind2=" "><subfield code="a">DE-627</subfield><subfield code="b">ger</subfield><subfield code="c">DE-627</subfield><subfield code="e">rakwb</subfield></datafield><datafield tag="041" ind1=" " ind2=" "><subfield code="a">eng</subfield></datafield><datafield tag="082" ind1="0" ind2="4"><subfield code="a">550</subfield><subfield code="q">VZ</subfield></datafield><datafield tag="084" ind1=" " ind2=" "><subfield code="a">14</subfield><subfield code="2">ssgn</subfield></datafield><datafield tag="084" ind1=" " ind2=" "><subfield code="a">RA 1000</subfield><subfield code="q">VZ</subfield><subfield code="2">rvk</subfield></datafield><datafield tag="100" ind1="1" ind2=" "><subfield code="a">Wan Zin, Wan Zawiah</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="245" ind1="1" ind2="0"><subfield code="a">The best fitting distribution of annual maximum rainfall in Peninsular Malaysia based on methods of L-moment and LQ-moment</subfield></datafield><datafield tag="264" ind1=" " ind2="1"><subfield code="c">2008</subfield></datafield><datafield tag="336" ind1=" " ind2=" "><subfield code="a">Text</subfield><subfield code="b">txt</subfield><subfield code="2">rdacontent</subfield></datafield><datafield tag="337" ind1=" " ind2=" "><subfield code="a">ohne Hilfsmittel zu benutzen</subfield><subfield code="b">n</subfield><subfield code="2">rdamedia</subfield></datafield><datafield tag="338" ind1=" " ind2=" "><subfield code="a">Band</subfield><subfield code="b">nc</subfield><subfield code="2">rdacarrier</subfield></datafield><datafield tag="500" ind1=" " ind2=" "><subfield code="a">© Springer-Verlag 2008</subfield></datafield><datafield tag="520" ind1=" " ind2=" "><subfield code="a">Abstract The main objective of this study is to determine the best fitting distribution to describe the annual series of maximum daily rainfall from 1975 to 2004 for 50 rain gauge stations in Peninsular Malaysia based on L-moment and LQ-moment. Five three-parameter extreme-value distributions which are considered are generalized extreme value (GEV), generalized Pareto (GP), generalized logistic (GL), lognormal (LN3) and Pearson (P3) distributions. The estimation of parameters of these distributions is determined using the L-moment and LQ-moment. The adequacy of the distributions based on parameter estimates computed using the two methods are evaluated using goodness-of-fit tests. When the goodness-of-fit results for these distributions are compared, it is found that, on the average, the performance of L-moment is better than the performance of LQ-moment. Although the best fitting distribution may vary according to the method of estimation and stations considered, in most cases, data for the majority of the stations are found to follow the generalized logistic distribution.</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Malaysia</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Generalize Extreme Value</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Extreme Rainfall</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Generalize Extreme Value Distribution</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Extreme Rainfall Event</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Jemain, Abdul Aziz</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Ibrahim, Kamarulzaman</subfield><subfield code="4">aut</subfield></datafield><datafield tag="773" ind1="0" ind2="8"><subfield code="i">Enthalten in</subfield><subfield code="t">Theoretical and applied climatology</subfield><subfield code="d">Springer Vienna, 1986</subfield><subfield code="g">96(2008), 3-4 vom: 17. Juli, Seite 337-344</subfield><subfield code="w">(DE-627)129958808</subfield><subfield code="w">(DE-600)405799-5</subfield><subfield code="w">(DE-576)01552857X</subfield><subfield code="x">0177-798X</subfield><subfield code="7">nnns</subfield></datafield><datafield tag="773" ind1="1" ind2="8"><subfield code="g">volume:96</subfield><subfield code="g">year:2008</subfield><subfield code="g">number:3-4</subfield><subfield code="g">day:17</subfield><subfield code="g">month:07</subfield><subfield code="g">pages:337-344</subfield></datafield><datafield tag="856" ind1="4" ind2="1"><subfield code="u">https://doi.org/10.1007/s00704-008-0044-2</subfield><subfield code="z">lizenzpflichtig</subfield><subfield code="3">Volltext</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_USEFLAG_A</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">SYSFLAG_A</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_OLC</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">SSG-OLC-GEO</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">SSG-OPC-GGO</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_40</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_70</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_381</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2003</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2006</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4012</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4029</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4306</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4311</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4313</subfield></datafield><datafield tag="936" ind1="r" ind2="v"><subfield code="a">RA 1000</subfield></datafield><datafield tag="951" ind1=" " ind2=" "><subfield code="a">AR</subfield></datafield><datafield tag="952" ind1=" " ind2=" "><subfield code="d">96</subfield><subfield code="j">2008</subfield><subfield code="e">3-4</subfield><subfield code="b">17</subfield><subfield code="c">07</subfield><subfield code="h">337-344</subfield></datafield></record></collection>
|
author |
Wan Zin, Wan Zawiah |
spellingShingle |
Wan Zin, Wan Zawiah ddc 550 ssgn 14 rvk RA 1000 misc Malaysia misc Generalize Extreme Value misc Extreme Rainfall misc Generalize Extreme Value Distribution misc Extreme Rainfall Event The best fitting distribution of annual maximum rainfall in Peninsular Malaysia based on methods of L-moment and LQ-moment |
authorStr |
Wan Zin, Wan Zawiah |
ppnlink_with_tag_str_mv |
@@773@@(DE-627)129958808 |
format |
Article |
dewey-ones |
550 - Earth sciences |
delete_txt_mv |
keep |
author_role |
aut aut aut |
collection |
OLC |
remote_str |
false |
illustrated |
Not Illustrated |
issn |
0177-798X |
topic_title |
550 VZ 14 ssgn RA 1000 VZ rvk The best fitting distribution of annual maximum rainfall in Peninsular Malaysia based on methods of L-moment and LQ-moment Malaysia Generalize Extreme Value Extreme Rainfall Generalize Extreme Value Distribution Extreme Rainfall Event |
topic |
ddc 550 ssgn 14 rvk RA 1000 misc Malaysia misc Generalize Extreme Value misc Extreme Rainfall misc Generalize Extreme Value Distribution misc Extreme Rainfall Event |
topic_unstemmed |
ddc 550 ssgn 14 rvk RA 1000 misc Malaysia misc Generalize Extreme Value misc Extreme Rainfall misc Generalize Extreme Value Distribution misc Extreme Rainfall Event |
topic_browse |
ddc 550 ssgn 14 rvk RA 1000 misc Malaysia misc Generalize Extreme Value misc Extreme Rainfall misc Generalize Extreme Value Distribution misc Extreme Rainfall Event |
format_facet |
Aufsätze Gedruckte Aufsätze |
format_main_str_mv |
Text Zeitschrift/Artikel |
carriertype_str_mv |
nc |
hierarchy_parent_title |
Theoretical and applied climatology |
hierarchy_parent_id |
129958808 |
dewey-tens |
550 - Earth sciences & geology |
hierarchy_top_title |
Theoretical and applied climatology |
isfreeaccess_txt |
false |
familylinks_str_mv |
(DE-627)129958808 (DE-600)405799-5 (DE-576)01552857X |
title |
The best fitting distribution of annual maximum rainfall in Peninsular Malaysia based on methods of L-moment and LQ-moment |
ctrlnum |
(DE-627)OLC2048442439 (DE-He213)s00704-008-0044-2-p |
title_full |
The best fitting distribution of annual maximum rainfall in Peninsular Malaysia based on methods of L-moment and LQ-moment |
author_sort |
Wan Zin, Wan Zawiah |
journal |
Theoretical and applied climatology |
journalStr |
Theoretical and applied climatology |
lang_code |
eng |
isOA_bool |
false |
dewey-hundreds |
500 - Science |
recordtype |
marc |
publishDateSort |
2008 |
contenttype_str_mv |
txt |
container_start_page |
337 |
author_browse |
Wan Zin, Wan Zawiah Jemain, Abdul Aziz Ibrahim, Kamarulzaman |
container_volume |
96 |
class |
550 VZ 14 ssgn RA 1000 VZ rvk |
format_se |
Aufsätze |
author-letter |
Wan Zin, Wan Zawiah |
doi_str_mv |
10.1007/s00704-008-0044-2 |
dewey-full |
550 |
title_sort |
the best fitting distribution of annual maximum rainfall in peninsular malaysia based on methods of l-moment and lq-moment |
title_auth |
The best fitting distribution of annual maximum rainfall in Peninsular Malaysia based on methods of L-moment and LQ-moment |
abstract |
Abstract The main objective of this study is to determine the best fitting distribution to describe the annual series of maximum daily rainfall from 1975 to 2004 for 50 rain gauge stations in Peninsular Malaysia based on L-moment and LQ-moment. Five three-parameter extreme-value distributions which are considered are generalized extreme value (GEV), generalized Pareto (GP), generalized logistic (GL), lognormal (LN3) and Pearson (P3) distributions. The estimation of parameters of these distributions is determined using the L-moment and LQ-moment. The adequacy of the distributions based on parameter estimates computed using the two methods are evaluated using goodness-of-fit tests. When the goodness-of-fit results for these distributions are compared, it is found that, on the average, the performance of L-moment is better than the performance of LQ-moment. Although the best fitting distribution may vary according to the method of estimation and stations considered, in most cases, data for the majority of the stations are found to follow the generalized logistic distribution. © Springer-Verlag 2008 |
abstractGer |
Abstract The main objective of this study is to determine the best fitting distribution to describe the annual series of maximum daily rainfall from 1975 to 2004 for 50 rain gauge stations in Peninsular Malaysia based on L-moment and LQ-moment. Five three-parameter extreme-value distributions which are considered are generalized extreme value (GEV), generalized Pareto (GP), generalized logistic (GL), lognormal (LN3) and Pearson (P3) distributions. The estimation of parameters of these distributions is determined using the L-moment and LQ-moment. The adequacy of the distributions based on parameter estimates computed using the two methods are evaluated using goodness-of-fit tests. When the goodness-of-fit results for these distributions are compared, it is found that, on the average, the performance of L-moment is better than the performance of LQ-moment. Although the best fitting distribution may vary according to the method of estimation and stations considered, in most cases, data for the majority of the stations are found to follow the generalized logistic distribution. © Springer-Verlag 2008 |
abstract_unstemmed |
Abstract The main objective of this study is to determine the best fitting distribution to describe the annual series of maximum daily rainfall from 1975 to 2004 for 50 rain gauge stations in Peninsular Malaysia based on L-moment and LQ-moment. Five three-parameter extreme-value distributions which are considered are generalized extreme value (GEV), generalized Pareto (GP), generalized logistic (GL), lognormal (LN3) and Pearson (P3) distributions. The estimation of parameters of these distributions is determined using the L-moment and LQ-moment. The adequacy of the distributions based on parameter estimates computed using the two methods are evaluated using goodness-of-fit tests. When the goodness-of-fit results for these distributions are compared, it is found that, on the average, the performance of L-moment is better than the performance of LQ-moment. Although the best fitting distribution may vary according to the method of estimation and stations considered, in most cases, data for the majority of the stations are found to follow the generalized logistic distribution. © Springer-Verlag 2008 |
collection_details |
GBV_USEFLAG_A SYSFLAG_A GBV_OLC SSG-OLC-GEO SSG-OPC-GGO GBV_ILN_40 GBV_ILN_70 GBV_ILN_381 GBV_ILN_2003 GBV_ILN_2006 GBV_ILN_4012 GBV_ILN_4029 GBV_ILN_4306 GBV_ILN_4311 GBV_ILN_4313 |
container_issue |
3-4 |
title_short |
The best fitting distribution of annual maximum rainfall in Peninsular Malaysia based on methods of L-moment and LQ-moment |
url |
https://doi.org/10.1007/s00704-008-0044-2 |
remote_bool |
false |
author2 |
Jemain, Abdul Aziz Ibrahim, Kamarulzaman |
author2Str |
Jemain, Abdul Aziz Ibrahim, Kamarulzaman |
ppnlink |
129958808 |
mediatype_str_mv |
n |
isOA_txt |
false |
hochschulschrift_bool |
false |
doi_str |
10.1007/s00704-008-0044-2 |
up_date |
2024-07-03T18:44:46.783Z |
_version_ |
1803584575145771008 |
fullrecord_marcxml |
<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim"><record><leader>01000caa a22002652 4500</leader><controlfield tag="001">OLC2048442439</controlfield><controlfield tag="003">DE-627</controlfield><controlfield tag="005">20230502135651.0</controlfield><controlfield tag="007">tu</controlfield><controlfield tag="008">200820s2008 xx ||||| 00| ||eng c</controlfield><datafield tag="024" ind1="7" ind2=" "><subfield code="a">10.1007/s00704-008-0044-2</subfield><subfield code="2">doi</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-627)OLC2048442439</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-He213)s00704-008-0044-2-p</subfield></datafield><datafield tag="040" ind1=" " ind2=" "><subfield code="a">DE-627</subfield><subfield code="b">ger</subfield><subfield code="c">DE-627</subfield><subfield code="e">rakwb</subfield></datafield><datafield tag="041" ind1=" " ind2=" "><subfield code="a">eng</subfield></datafield><datafield tag="082" ind1="0" ind2="4"><subfield code="a">550</subfield><subfield code="q">VZ</subfield></datafield><datafield tag="084" ind1=" " ind2=" "><subfield code="a">14</subfield><subfield code="2">ssgn</subfield></datafield><datafield tag="084" ind1=" " ind2=" "><subfield code="a">RA 1000</subfield><subfield code="q">VZ</subfield><subfield code="2">rvk</subfield></datafield><datafield tag="100" ind1="1" ind2=" "><subfield code="a">Wan Zin, Wan Zawiah</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="245" ind1="1" ind2="0"><subfield code="a">The best fitting distribution of annual maximum rainfall in Peninsular Malaysia based on methods of L-moment and LQ-moment</subfield></datafield><datafield tag="264" ind1=" " ind2="1"><subfield code="c">2008</subfield></datafield><datafield tag="336" ind1=" " ind2=" "><subfield code="a">Text</subfield><subfield code="b">txt</subfield><subfield code="2">rdacontent</subfield></datafield><datafield tag="337" ind1=" " ind2=" "><subfield code="a">ohne Hilfsmittel zu benutzen</subfield><subfield code="b">n</subfield><subfield code="2">rdamedia</subfield></datafield><datafield tag="338" ind1=" " ind2=" "><subfield code="a">Band</subfield><subfield code="b">nc</subfield><subfield code="2">rdacarrier</subfield></datafield><datafield tag="500" ind1=" " ind2=" "><subfield code="a">© Springer-Verlag 2008</subfield></datafield><datafield tag="520" ind1=" " ind2=" "><subfield code="a">Abstract The main objective of this study is to determine the best fitting distribution to describe the annual series of maximum daily rainfall from 1975 to 2004 for 50 rain gauge stations in Peninsular Malaysia based on L-moment and LQ-moment. Five three-parameter extreme-value distributions which are considered are generalized extreme value (GEV), generalized Pareto (GP), generalized logistic (GL), lognormal (LN3) and Pearson (P3) distributions. The estimation of parameters of these distributions is determined using the L-moment and LQ-moment. The adequacy of the distributions based on parameter estimates computed using the two methods are evaluated using goodness-of-fit tests. When the goodness-of-fit results for these distributions are compared, it is found that, on the average, the performance of L-moment is better than the performance of LQ-moment. Although the best fitting distribution may vary according to the method of estimation and stations considered, in most cases, data for the majority of the stations are found to follow the generalized logistic distribution.</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Malaysia</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Generalize Extreme Value</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Extreme Rainfall</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Generalize Extreme Value Distribution</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Extreme Rainfall Event</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Jemain, Abdul Aziz</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Ibrahim, Kamarulzaman</subfield><subfield code="4">aut</subfield></datafield><datafield tag="773" ind1="0" ind2="8"><subfield code="i">Enthalten in</subfield><subfield code="t">Theoretical and applied climatology</subfield><subfield code="d">Springer Vienna, 1986</subfield><subfield code="g">96(2008), 3-4 vom: 17. Juli, Seite 337-344</subfield><subfield code="w">(DE-627)129958808</subfield><subfield code="w">(DE-600)405799-5</subfield><subfield code="w">(DE-576)01552857X</subfield><subfield code="x">0177-798X</subfield><subfield code="7">nnns</subfield></datafield><datafield tag="773" ind1="1" ind2="8"><subfield code="g">volume:96</subfield><subfield code="g">year:2008</subfield><subfield code="g">number:3-4</subfield><subfield code="g">day:17</subfield><subfield code="g">month:07</subfield><subfield code="g">pages:337-344</subfield></datafield><datafield tag="856" ind1="4" ind2="1"><subfield code="u">https://doi.org/10.1007/s00704-008-0044-2</subfield><subfield code="z">lizenzpflichtig</subfield><subfield code="3">Volltext</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_USEFLAG_A</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">SYSFLAG_A</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_OLC</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">SSG-OLC-GEO</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">SSG-OPC-GGO</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_40</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_70</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_381</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2003</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2006</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4012</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4029</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4306</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4311</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4313</subfield></datafield><datafield tag="936" ind1="r" ind2="v"><subfield code="a">RA 1000</subfield></datafield><datafield tag="951" ind1=" " ind2=" "><subfield code="a">AR</subfield></datafield><datafield tag="952" ind1=" " ind2=" "><subfield code="d">96</subfield><subfield code="j">2008</subfield><subfield code="e">3-4</subfield><subfield code="b">17</subfield><subfield code="c">07</subfield><subfield code="h">337-344</subfield></datafield></record></collection>
|
score |
7.397565 |