Characterizing Firebrand Exposure from Wildland–Urban Interface (WUI) Fires: Results from the 2007 Angora Fire
Abstract This study examines the size distribution and other characteristics of firebrand exposure during the 2007 Angora fire, a severe wildland–urban interface fire in California. Of the 401 houses that received direct interface fire exposure 61% were destroyed and 30% did not burn at all. The ign...
Ausführliche Beschreibung
Autor*in: |
Manzello, Samuel L. [verfasserIn] |
---|
Format: |
Artikel |
---|---|
Sprache: |
Englisch |
Erschienen: |
2012 |
---|
Schlagwörter: |
---|
Anmerkung: |
© Springer Science+Business Media, LLC (Outside the USA) 2012 |
---|
Übergeordnetes Werk: |
Enthalten in: Fire technology - Springer US, 1965, 50(2012), 1 vom: 22. Sept., Seite 105-124 |
---|---|
Übergeordnetes Werk: |
volume:50 ; year:2012 ; number:1 ; day:22 ; month:09 ; pages:105-124 |
Links: |
---|
DOI / URN: |
10.1007/s10694-012-0295-4 |
---|
Katalog-ID: |
OLC2072760380 |
---|
LEADER | 01000caa a22002652 4500 | ||
---|---|---|---|
001 | OLC2072760380 | ||
003 | DE-627 | ||
005 | 20230503060628.0 | ||
007 | tu | ||
008 | 200819s2012 xx ||||| 00| ||eng c | ||
024 | 7 | |a 10.1007/s10694-012-0295-4 |2 doi | |
035 | |a (DE-627)OLC2072760380 | ||
035 | |a (DE-He213)s10694-012-0295-4-p | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
082 | 0 | 4 | |a 690 |a 620 |q VZ |
100 | 1 | |a Manzello, Samuel L. |e verfasserin |4 aut | |
245 | 1 | 0 | |a Characterizing Firebrand Exposure from Wildland–Urban Interface (WUI) Fires: Results from the 2007 Angora Fire |
264 | 1 | |c 2012 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a ohne Hilfsmittel zu benutzen |b n |2 rdamedia | ||
338 | |a Band |b nc |2 rdacarrier | ||
500 | |a © Springer Science+Business Media, LLC (Outside the USA) 2012 | ||
520 | |a Abstract This study examines the size distribution and other characteristics of firebrand exposure during the 2007 Angora fire, a severe wildland–urban interface fire in California. Of the 401 houses that received direct interface fire exposure 61% were destroyed and 30% did not burn at all. The ignition of buildings by wind-driven firebrand showers and the starting of “spot fires” in unburned vegetation ahead of wildfires have been observed for some time. Empirically quantifying the exposure severity or describing how many firebrands of what size and over what duration and distance cause ignition problems of concern has not yet been possible. However, a unique opportunity to gather empirical firebrand data from an actual interface fire evolved in the days immediately following the Angora fire. Digital analyses of burn patterns from materials exposed to the Angora fire were conducted to determine firebrand size distributions. It is probable that some burn patterns were larger in area than the firebrands due to progressive combustion or melting, but it was assumed that the overall size distributions of burn pattern areas were representative of actual firebrand sizes. This assumption was investigated by exposing sections of materials collected in the Angora fire to wind driven firebrands generated in the laboratory using the unique NIST Dragon’s lofting and ignition research facility (NIST Dragon’s LAIR facility). The firebrand size distributions reported were compared to firebrand size distributions from experimental firebrand generation in both recent laboratory building ignition studies conducted by NIST and from historical firebrand field studies. Such data is needed to form the basis of effective and appropriate interface fire hazard mitigation measures as well as modeling fire spread. Comparisons are made to current wildfire protection building construction regulations and test standards. The most salient result of this study is documentation of the consistently small size of firebrands and the close correlation of these results with the sizes of experimentally generated firebrands. | ||
650 | 4 | |a Firebrands | |
650 | 4 | |a Wildland–urban interface (WUI) fire | |
650 | 4 | |a Firebrand exposure | |
700 | 1 | |a Foote, Ethan I. D. |4 aut | |
773 | 0 | 8 | |i Enthalten in |t Fire technology |d Springer US, 1965 |g 50(2012), 1 vom: 22. Sept., Seite 105-124 |w (DE-627)130411485 |w (DE-600)622603-6 |w (DE-576)028033434 |x 0015-2684 |7 nnns |
773 | 1 | 8 | |g volume:50 |g year:2012 |g number:1 |g day:22 |g month:09 |g pages:105-124 |
856 | 4 | 1 | |u https://doi.org/10.1007/s10694-012-0295-4 |z lizenzpflichtig |3 Volltext |
912 | |a GBV_USEFLAG_A | ||
912 | |a SYSFLAG_A | ||
912 | |a GBV_OLC | ||
912 | |a SSG-OLC-UMW | ||
912 | |a SSG-OLC-ARC | ||
912 | |a SSG-OLC-TEC | ||
912 | |a GBV_ILN_70 | ||
912 | |a GBV_ILN_2014 | ||
951 | |a AR | ||
952 | |d 50 |j 2012 |e 1 |b 22 |c 09 |h 105-124 |
author_variant |
s l m sl slm e i d f eid eidf |
---|---|
matchkey_str |
article:00152684:2012----::hrceiigiernepsrfowllnubnnefcwiiers |
hierarchy_sort_str |
2012 |
publishDate |
2012 |
allfields |
10.1007/s10694-012-0295-4 doi (DE-627)OLC2072760380 (DE-He213)s10694-012-0295-4-p DE-627 ger DE-627 rakwb eng 690 620 VZ Manzello, Samuel L. verfasserin aut Characterizing Firebrand Exposure from Wildland–Urban Interface (WUI) Fires: Results from the 2007 Angora Fire 2012 Text txt rdacontent ohne Hilfsmittel zu benutzen n rdamedia Band nc rdacarrier © Springer Science+Business Media, LLC (Outside the USA) 2012 Abstract This study examines the size distribution and other characteristics of firebrand exposure during the 2007 Angora fire, a severe wildland–urban interface fire in California. Of the 401 houses that received direct interface fire exposure 61% were destroyed and 30% did not burn at all. The ignition of buildings by wind-driven firebrand showers and the starting of “spot fires” in unburned vegetation ahead of wildfires have been observed for some time. Empirically quantifying the exposure severity or describing how many firebrands of what size and over what duration and distance cause ignition problems of concern has not yet been possible. However, a unique opportunity to gather empirical firebrand data from an actual interface fire evolved in the days immediately following the Angora fire. Digital analyses of burn patterns from materials exposed to the Angora fire were conducted to determine firebrand size distributions. It is probable that some burn patterns were larger in area than the firebrands due to progressive combustion or melting, but it was assumed that the overall size distributions of burn pattern areas were representative of actual firebrand sizes. This assumption was investigated by exposing sections of materials collected in the Angora fire to wind driven firebrands generated in the laboratory using the unique NIST Dragon’s lofting and ignition research facility (NIST Dragon’s LAIR facility). The firebrand size distributions reported were compared to firebrand size distributions from experimental firebrand generation in both recent laboratory building ignition studies conducted by NIST and from historical firebrand field studies. Such data is needed to form the basis of effective and appropriate interface fire hazard mitigation measures as well as modeling fire spread. Comparisons are made to current wildfire protection building construction regulations and test standards. The most salient result of this study is documentation of the consistently small size of firebrands and the close correlation of these results with the sizes of experimentally generated firebrands. Firebrands Wildland–urban interface (WUI) fire Firebrand exposure Foote, Ethan I. D. aut Enthalten in Fire technology Springer US, 1965 50(2012), 1 vom: 22. Sept., Seite 105-124 (DE-627)130411485 (DE-600)622603-6 (DE-576)028033434 0015-2684 nnns volume:50 year:2012 number:1 day:22 month:09 pages:105-124 https://doi.org/10.1007/s10694-012-0295-4 lizenzpflichtig Volltext GBV_USEFLAG_A SYSFLAG_A GBV_OLC SSG-OLC-UMW SSG-OLC-ARC SSG-OLC-TEC GBV_ILN_70 GBV_ILN_2014 AR 50 2012 1 22 09 105-124 |
spelling |
10.1007/s10694-012-0295-4 doi (DE-627)OLC2072760380 (DE-He213)s10694-012-0295-4-p DE-627 ger DE-627 rakwb eng 690 620 VZ Manzello, Samuel L. verfasserin aut Characterizing Firebrand Exposure from Wildland–Urban Interface (WUI) Fires: Results from the 2007 Angora Fire 2012 Text txt rdacontent ohne Hilfsmittel zu benutzen n rdamedia Band nc rdacarrier © Springer Science+Business Media, LLC (Outside the USA) 2012 Abstract This study examines the size distribution and other characteristics of firebrand exposure during the 2007 Angora fire, a severe wildland–urban interface fire in California. Of the 401 houses that received direct interface fire exposure 61% were destroyed and 30% did not burn at all. The ignition of buildings by wind-driven firebrand showers and the starting of “spot fires” in unburned vegetation ahead of wildfires have been observed for some time. Empirically quantifying the exposure severity or describing how many firebrands of what size and over what duration and distance cause ignition problems of concern has not yet been possible. However, a unique opportunity to gather empirical firebrand data from an actual interface fire evolved in the days immediately following the Angora fire. Digital analyses of burn patterns from materials exposed to the Angora fire were conducted to determine firebrand size distributions. It is probable that some burn patterns were larger in area than the firebrands due to progressive combustion or melting, but it was assumed that the overall size distributions of burn pattern areas were representative of actual firebrand sizes. This assumption was investigated by exposing sections of materials collected in the Angora fire to wind driven firebrands generated in the laboratory using the unique NIST Dragon’s lofting and ignition research facility (NIST Dragon’s LAIR facility). The firebrand size distributions reported were compared to firebrand size distributions from experimental firebrand generation in both recent laboratory building ignition studies conducted by NIST and from historical firebrand field studies. Such data is needed to form the basis of effective and appropriate interface fire hazard mitigation measures as well as modeling fire spread. Comparisons are made to current wildfire protection building construction regulations and test standards. The most salient result of this study is documentation of the consistently small size of firebrands and the close correlation of these results with the sizes of experimentally generated firebrands. Firebrands Wildland–urban interface (WUI) fire Firebrand exposure Foote, Ethan I. D. aut Enthalten in Fire technology Springer US, 1965 50(2012), 1 vom: 22. Sept., Seite 105-124 (DE-627)130411485 (DE-600)622603-6 (DE-576)028033434 0015-2684 nnns volume:50 year:2012 number:1 day:22 month:09 pages:105-124 https://doi.org/10.1007/s10694-012-0295-4 lizenzpflichtig Volltext GBV_USEFLAG_A SYSFLAG_A GBV_OLC SSG-OLC-UMW SSG-OLC-ARC SSG-OLC-TEC GBV_ILN_70 GBV_ILN_2014 AR 50 2012 1 22 09 105-124 |
allfields_unstemmed |
10.1007/s10694-012-0295-4 doi (DE-627)OLC2072760380 (DE-He213)s10694-012-0295-4-p DE-627 ger DE-627 rakwb eng 690 620 VZ Manzello, Samuel L. verfasserin aut Characterizing Firebrand Exposure from Wildland–Urban Interface (WUI) Fires: Results from the 2007 Angora Fire 2012 Text txt rdacontent ohne Hilfsmittel zu benutzen n rdamedia Band nc rdacarrier © Springer Science+Business Media, LLC (Outside the USA) 2012 Abstract This study examines the size distribution and other characteristics of firebrand exposure during the 2007 Angora fire, a severe wildland–urban interface fire in California. Of the 401 houses that received direct interface fire exposure 61% were destroyed and 30% did not burn at all. The ignition of buildings by wind-driven firebrand showers and the starting of “spot fires” in unburned vegetation ahead of wildfires have been observed for some time. Empirically quantifying the exposure severity or describing how many firebrands of what size and over what duration and distance cause ignition problems of concern has not yet been possible. However, a unique opportunity to gather empirical firebrand data from an actual interface fire evolved in the days immediately following the Angora fire. Digital analyses of burn patterns from materials exposed to the Angora fire were conducted to determine firebrand size distributions. It is probable that some burn patterns were larger in area than the firebrands due to progressive combustion or melting, but it was assumed that the overall size distributions of burn pattern areas were representative of actual firebrand sizes. This assumption was investigated by exposing sections of materials collected in the Angora fire to wind driven firebrands generated in the laboratory using the unique NIST Dragon’s lofting and ignition research facility (NIST Dragon’s LAIR facility). The firebrand size distributions reported were compared to firebrand size distributions from experimental firebrand generation in both recent laboratory building ignition studies conducted by NIST and from historical firebrand field studies. Such data is needed to form the basis of effective and appropriate interface fire hazard mitigation measures as well as modeling fire spread. Comparisons are made to current wildfire protection building construction regulations and test standards. The most salient result of this study is documentation of the consistently small size of firebrands and the close correlation of these results with the sizes of experimentally generated firebrands. Firebrands Wildland–urban interface (WUI) fire Firebrand exposure Foote, Ethan I. D. aut Enthalten in Fire technology Springer US, 1965 50(2012), 1 vom: 22. Sept., Seite 105-124 (DE-627)130411485 (DE-600)622603-6 (DE-576)028033434 0015-2684 nnns volume:50 year:2012 number:1 day:22 month:09 pages:105-124 https://doi.org/10.1007/s10694-012-0295-4 lizenzpflichtig Volltext GBV_USEFLAG_A SYSFLAG_A GBV_OLC SSG-OLC-UMW SSG-OLC-ARC SSG-OLC-TEC GBV_ILN_70 GBV_ILN_2014 AR 50 2012 1 22 09 105-124 |
allfieldsGer |
10.1007/s10694-012-0295-4 doi (DE-627)OLC2072760380 (DE-He213)s10694-012-0295-4-p DE-627 ger DE-627 rakwb eng 690 620 VZ Manzello, Samuel L. verfasserin aut Characterizing Firebrand Exposure from Wildland–Urban Interface (WUI) Fires: Results from the 2007 Angora Fire 2012 Text txt rdacontent ohne Hilfsmittel zu benutzen n rdamedia Band nc rdacarrier © Springer Science+Business Media, LLC (Outside the USA) 2012 Abstract This study examines the size distribution and other characteristics of firebrand exposure during the 2007 Angora fire, a severe wildland–urban interface fire in California. Of the 401 houses that received direct interface fire exposure 61% were destroyed and 30% did not burn at all. The ignition of buildings by wind-driven firebrand showers and the starting of “spot fires” in unburned vegetation ahead of wildfires have been observed for some time. Empirically quantifying the exposure severity or describing how many firebrands of what size and over what duration and distance cause ignition problems of concern has not yet been possible. However, a unique opportunity to gather empirical firebrand data from an actual interface fire evolved in the days immediately following the Angora fire. Digital analyses of burn patterns from materials exposed to the Angora fire were conducted to determine firebrand size distributions. It is probable that some burn patterns were larger in area than the firebrands due to progressive combustion or melting, but it was assumed that the overall size distributions of burn pattern areas were representative of actual firebrand sizes. This assumption was investigated by exposing sections of materials collected in the Angora fire to wind driven firebrands generated in the laboratory using the unique NIST Dragon’s lofting and ignition research facility (NIST Dragon’s LAIR facility). The firebrand size distributions reported were compared to firebrand size distributions from experimental firebrand generation in both recent laboratory building ignition studies conducted by NIST and from historical firebrand field studies. Such data is needed to form the basis of effective and appropriate interface fire hazard mitigation measures as well as modeling fire spread. Comparisons are made to current wildfire protection building construction regulations and test standards. The most salient result of this study is documentation of the consistently small size of firebrands and the close correlation of these results with the sizes of experimentally generated firebrands. Firebrands Wildland–urban interface (WUI) fire Firebrand exposure Foote, Ethan I. D. aut Enthalten in Fire technology Springer US, 1965 50(2012), 1 vom: 22. Sept., Seite 105-124 (DE-627)130411485 (DE-600)622603-6 (DE-576)028033434 0015-2684 nnns volume:50 year:2012 number:1 day:22 month:09 pages:105-124 https://doi.org/10.1007/s10694-012-0295-4 lizenzpflichtig Volltext GBV_USEFLAG_A SYSFLAG_A GBV_OLC SSG-OLC-UMW SSG-OLC-ARC SSG-OLC-TEC GBV_ILN_70 GBV_ILN_2014 AR 50 2012 1 22 09 105-124 |
allfieldsSound |
10.1007/s10694-012-0295-4 doi (DE-627)OLC2072760380 (DE-He213)s10694-012-0295-4-p DE-627 ger DE-627 rakwb eng 690 620 VZ Manzello, Samuel L. verfasserin aut Characterizing Firebrand Exposure from Wildland–Urban Interface (WUI) Fires: Results from the 2007 Angora Fire 2012 Text txt rdacontent ohne Hilfsmittel zu benutzen n rdamedia Band nc rdacarrier © Springer Science+Business Media, LLC (Outside the USA) 2012 Abstract This study examines the size distribution and other characteristics of firebrand exposure during the 2007 Angora fire, a severe wildland–urban interface fire in California. Of the 401 houses that received direct interface fire exposure 61% were destroyed and 30% did not burn at all. The ignition of buildings by wind-driven firebrand showers and the starting of “spot fires” in unburned vegetation ahead of wildfires have been observed for some time. Empirically quantifying the exposure severity or describing how many firebrands of what size and over what duration and distance cause ignition problems of concern has not yet been possible. However, a unique opportunity to gather empirical firebrand data from an actual interface fire evolved in the days immediately following the Angora fire. Digital analyses of burn patterns from materials exposed to the Angora fire were conducted to determine firebrand size distributions. It is probable that some burn patterns were larger in area than the firebrands due to progressive combustion or melting, but it was assumed that the overall size distributions of burn pattern areas were representative of actual firebrand sizes. This assumption was investigated by exposing sections of materials collected in the Angora fire to wind driven firebrands generated in the laboratory using the unique NIST Dragon’s lofting and ignition research facility (NIST Dragon’s LAIR facility). The firebrand size distributions reported were compared to firebrand size distributions from experimental firebrand generation in both recent laboratory building ignition studies conducted by NIST and from historical firebrand field studies. Such data is needed to form the basis of effective and appropriate interface fire hazard mitigation measures as well as modeling fire spread. Comparisons are made to current wildfire protection building construction regulations and test standards. The most salient result of this study is documentation of the consistently small size of firebrands and the close correlation of these results with the sizes of experimentally generated firebrands. Firebrands Wildland–urban interface (WUI) fire Firebrand exposure Foote, Ethan I. D. aut Enthalten in Fire technology Springer US, 1965 50(2012), 1 vom: 22. Sept., Seite 105-124 (DE-627)130411485 (DE-600)622603-6 (DE-576)028033434 0015-2684 nnns volume:50 year:2012 number:1 day:22 month:09 pages:105-124 https://doi.org/10.1007/s10694-012-0295-4 lizenzpflichtig Volltext GBV_USEFLAG_A SYSFLAG_A GBV_OLC SSG-OLC-UMW SSG-OLC-ARC SSG-OLC-TEC GBV_ILN_70 GBV_ILN_2014 AR 50 2012 1 22 09 105-124 |
language |
English |
source |
Enthalten in Fire technology 50(2012), 1 vom: 22. Sept., Seite 105-124 volume:50 year:2012 number:1 day:22 month:09 pages:105-124 |
sourceStr |
Enthalten in Fire technology 50(2012), 1 vom: 22. Sept., Seite 105-124 volume:50 year:2012 number:1 day:22 month:09 pages:105-124 |
format_phy_str_mv |
Article |
institution |
findex.gbv.de |
topic_facet |
Firebrands Wildland–urban interface (WUI) fire Firebrand exposure |
dewey-raw |
690 |
isfreeaccess_bool |
false |
container_title |
Fire technology |
authorswithroles_txt_mv |
Manzello, Samuel L. @@aut@@ Foote, Ethan I. D. @@aut@@ |
publishDateDaySort_date |
2012-09-22T00:00:00Z |
hierarchy_top_id |
130411485 |
dewey-sort |
3690 |
id |
OLC2072760380 |
language_de |
englisch |
fullrecord |
<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim"><record><leader>01000caa a22002652 4500</leader><controlfield tag="001">OLC2072760380</controlfield><controlfield tag="003">DE-627</controlfield><controlfield tag="005">20230503060628.0</controlfield><controlfield tag="007">tu</controlfield><controlfield tag="008">200819s2012 xx ||||| 00| ||eng c</controlfield><datafield tag="024" ind1="7" ind2=" "><subfield code="a">10.1007/s10694-012-0295-4</subfield><subfield code="2">doi</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-627)OLC2072760380</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-He213)s10694-012-0295-4-p</subfield></datafield><datafield tag="040" ind1=" " ind2=" "><subfield code="a">DE-627</subfield><subfield code="b">ger</subfield><subfield code="c">DE-627</subfield><subfield code="e">rakwb</subfield></datafield><datafield tag="041" ind1=" " ind2=" "><subfield code="a">eng</subfield></datafield><datafield tag="082" ind1="0" ind2="4"><subfield code="a">690</subfield><subfield code="a">620</subfield><subfield code="q">VZ</subfield></datafield><datafield tag="100" ind1="1" ind2=" "><subfield code="a">Manzello, Samuel L.</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="245" ind1="1" ind2="0"><subfield code="a">Characterizing Firebrand Exposure from Wildland–Urban Interface (WUI) Fires: Results from the 2007 Angora Fire</subfield></datafield><datafield tag="264" ind1=" " ind2="1"><subfield code="c">2012</subfield></datafield><datafield tag="336" ind1=" " ind2=" "><subfield code="a">Text</subfield><subfield code="b">txt</subfield><subfield code="2">rdacontent</subfield></datafield><datafield tag="337" ind1=" " ind2=" "><subfield code="a">ohne Hilfsmittel zu benutzen</subfield><subfield code="b">n</subfield><subfield code="2">rdamedia</subfield></datafield><datafield tag="338" ind1=" " ind2=" "><subfield code="a">Band</subfield><subfield code="b">nc</subfield><subfield code="2">rdacarrier</subfield></datafield><datafield tag="500" ind1=" " ind2=" "><subfield code="a">© Springer Science+Business Media, LLC (Outside the USA) 2012</subfield></datafield><datafield tag="520" ind1=" " ind2=" "><subfield code="a">Abstract This study examines the size distribution and other characteristics of firebrand exposure during the 2007 Angora fire, a severe wildland–urban interface fire in California. Of the 401 houses that received direct interface fire exposure 61% were destroyed and 30% did not burn at all. The ignition of buildings by wind-driven firebrand showers and the starting of “spot fires” in unburned vegetation ahead of wildfires have been observed for some time. Empirically quantifying the exposure severity or describing how many firebrands of what size and over what duration and distance cause ignition problems of concern has not yet been possible. However, a unique opportunity to gather empirical firebrand data from an actual interface fire evolved in the days immediately following the Angora fire. Digital analyses of burn patterns from materials exposed to the Angora fire were conducted to determine firebrand size distributions. It is probable that some burn patterns were larger in area than the firebrands due to progressive combustion or melting, but it was assumed that the overall size distributions of burn pattern areas were representative of actual firebrand sizes. This assumption was investigated by exposing sections of materials collected in the Angora fire to wind driven firebrands generated in the laboratory using the unique NIST Dragon’s lofting and ignition research facility (NIST Dragon’s LAIR facility). The firebrand size distributions reported were compared to firebrand size distributions from experimental firebrand generation in both recent laboratory building ignition studies conducted by NIST and from historical firebrand field studies. Such data is needed to form the basis of effective and appropriate interface fire hazard mitigation measures as well as modeling fire spread. Comparisons are made to current wildfire protection building construction regulations and test standards. The most salient result of this study is documentation of the consistently small size of firebrands and the close correlation of these results with the sizes of experimentally generated firebrands.</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Firebrands</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Wildland–urban interface (WUI) fire</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Firebrand exposure</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Foote, Ethan I. D.</subfield><subfield code="4">aut</subfield></datafield><datafield tag="773" ind1="0" ind2="8"><subfield code="i">Enthalten in</subfield><subfield code="t">Fire technology</subfield><subfield code="d">Springer US, 1965</subfield><subfield code="g">50(2012), 1 vom: 22. Sept., Seite 105-124</subfield><subfield code="w">(DE-627)130411485</subfield><subfield code="w">(DE-600)622603-6</subfield><subfield code="w">(DE-576)028033434</subfield><subfield code="x">0015-2684</subfield><subfield code="7">nnns</subfield></datafield><datafield tag="773" ind1="1" ind2="8"><subfield code="g">volume:50</subfield><subfield code="g">year:2012</subfield><subfield code="g">number:1</subfield><subfield code="g">day:22</subfield><subfield code="g">month:09</subfield><subfield code="g">pages:105-124</subfield></datafield><datafield tag="856" ind1="4" ind2="1"><subfield code="u">https://doi.org/10.1007/s10694-012-0295-4</subfield><subfield code="z">lizenzpflichtig</subfield><subfield code="3">Volltext</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_USEFLAG_A</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">SYSFLAG_A</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_OLC</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">SSG-OLC-UMW</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">SSG-OLC-ARC</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">SSG-OLC-TEC</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_70</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2014</subfield></datafield><datafield tag="951" ind1=" " ind2=" "><subfield code="a">AR</subfield></datafield><datafield tag="952" ind1=" " ind2=" "><subfield code="d">50</subfield><subfield code="j">2012</subfield><subfield code="e">1</subfield><subfield code="b">22</subfield><subfield code="c">09</subfield><subfield code="h">105-124</subfield></datafield></record></collection>
|
author |
Manzello, Samuel L. |
spellingShingle |
Manzello, Samuel L. ddc 690 misc Firebrands misc Wildland–urban interface (WUI) fire misc Firebrand exposure Characterizing Firebrand Exposure from Wildland–Urban Interface (WUI) Fires: Results from the 2007 Angora Fire |
authorStr |
Manzello, Samuel L. |
ppnlink_with_tag_str_mv |
@@773@@(DE-627)130411485 |
format |
Article |
dewey-ones |
690 - Buildings 620 - Engineering & allied operations |
delete_txt_mv |
keep |
author_role |
aut aut |
collection |
OLC |
remote_str |
false |
illustrated |
Not Illustrated |
issn |
0015-2684 |
topic_title |
690 620 VZ Characterizing Firebrand Exposure from Wildland–Urban Interface (WUI) Fires: Results from the 2007 Angora Fire Firebrands Wildland–urban interface (WUI) fire Firebrand exposure |
topic |
ddc 690 misc Firebrands misc Wildland–urban interface (WUI) fire misc Firebrand exposure |
topic_unstemmed |
ddc 690 misc Firebrands misc Wildland–urban interface (WUI) fire misc Firebrand exposure |
topic_browse |
ddc 690 misc Firebrands misc Wildland–urban interface (WUI) fire misc Firebrand exposure |
format_facet |
Aufsätze Gedruckte Aufsätze |
format_main_str_mv |
Text Zeitschrift/Artikel |
carriertype_str_mv |
nc |
hierarchy_parent_title |
Fire technology |
hierarchy_parent_id |
130411485 |
dewey-tens |
690 - Building & construction 620 - Engineering |
hierarchy_top_title |
Fire technology |
isfreeaccess_txt |
false |
familylinks_str_mv |
(DE-627)130411485 (DE-600)622603-6 (DE-576)028033434 |
title |
Characterizing Firebrand Exposure from Wildland–Urban Interface (WUI) Fires: Results from the 2007 Angora Fire |
ctrlnum |
(DE-627)OLC2072760380 (DE-He213)s10694-012-0295-4-p |
title_full |
Characterizing Firebrand Exposure from Wildland–Urban Interface (WUI) Fires: Results from the 2007 Angora Fire |
author_sort |
Manzello, Samuel L. |
journal |
Fire technology |
journalStr |
Fire technology |
lang_code |
eng |
isOA_bool |
false |
dewey-hundreds |
600 - Technology |
recordtype |
marc |
publishDateSort |
2012 |
contenttype_str_mv |
txt |
container_start_page |
105 |
author_browse |
Manzello, Samuel L. Foote, Ethan I. D. |
container_volume |
50 |
class |
690 620 VZ |
format_se |
Aufsätze |
author-letter |
Manzello, Samuel L. |
doi_str_mv |
10.1007/s10694-012-0295-4 |
dewey-full |
690 620 |
title_sort |
characterizing firebrand exposure from wildland–urban interface (wui) fires: results from the 2007 angora fire |
title_auth |
Characterizing Firebrand Exposure from Wildland–Urban Interface (WUI) Fires: Results from the 2007 Angora Fire |
abstract |
Abstract This study examines the size distribution and other characteristics of firebrand exposure during the 2007 Angora fire, a severe wildland–urban interface fire in California. Of the 401 houses that received direct interface fire exposure 61% were destroyed and 30% did not burn at all. The ignition of buildings by wind-driven firebrand showers and the starting of “spot fires” in unburned vegetation ahead of wildfires have been observed for some time. Empirically quantifying the exposure severity or describing how many firebrands of what size and over what duration and distance cause ignition problems of concern has not yet been possible. However, a unique opportunity to gather empirical firebrand data from an actual interface fire evolved in the days immediately following the Angora fire. Digital analyses of burn patterns from materials exposed to the Angora fire were conducted to determine firebrand size distributions. It is probable that some burn patterns were larger in area than the firebrands due to progressive combustion or melting, but it was assumed that the overall size distributions of burn pattern areas were representative of actual firebrand sizes. This assumption was investigated by exposing sections of materials collected in the Angora fire to wind driven firebrands generated in the laboratory using the unique NIST Dragon’s lofting and ignition research facility (NIST Dragon’s LAIR facility). The firebrand size distributions reported were compared to firebrand size distributions from experimental firebrand generation in both recent laboratory building ignition studies conducted by NIST and from historical firebrand field studies. Such data is needed to form the basis of effective and appropriate interface fire hazard mitigation measures as well as modeling fire spread. Comparisons are made to current wildfire protection building construction regulations and test standards. The most salient result of this study is documentation of the consistently small size of firebrands and the close correlation of these results with the sizes of experimentally generated firebrands. © Springer Science+Business Media, LLC (Outside the USA) 2012 |
abstractGer |
Abstract This study examines the size distribution and other characteristics of firebrand exposure during the 2007 Angora fire, a severe wildland–urban interface fire in California. Of the 401 houses that received direct interface fire exposure 61% were destroyed and 30% did not burn at all. The ignition of buildings by wind-driven firebrand showers and the starting of “spot fires” in unburned vegetation ahead of wildfires have been observed for some time. Empirically quantifying the exposure severity or describing how many firebrands of what size and over what duration and distance cause ignition problems of concern has not yet been possible. However, a unique opportunity to gather empirical firebrand data from an actual interface fire evolved in the days immediately following the Angora fire. Digital analyses of burn patterns from materials exposed to the Angora fire were conducted to determine firebrand size distributions. It is probable that some burn patterns were larger in area than the firebrands due to progressive combustion or melting, but it was assumed that the overall size distributions of burn pattern areas were representative of actual firebrand sizes. This assumption was investigated by exposing sections of materials collected in the Angora fire to wind driven firebrands generated in the laboratory using the unique NIST Dragon’s lofting and ignition research facility (NIST Dragon’s LAIR facility). The firebrand size distributions reported were compared to firebrand size distributions from experimental firebrand generation in both recent laboratory building ignition studies conducted by NIST and from historical firebrand field studies. Such data is needed to form the basis of effective and appropriate interface fire hazard mitigation measures as well as modeling fire spread. Comparisons are made to current wildfire protection building construction regulations and test standards. The most salient result of this study is documentation of the consistently small size of firebrands and the close correlation of these results with the sizes of experimentally generated firebrands. © Springer Science+Business Media, LLC (Outside the USA) 2012 |
abstract_unstemmed |
Abstract This study examines the size distribution and other characteristics of firebrand exposure during the 2007 Angora fire, a severe wildland–urban interface fire in California. Of the 401 houses that received direct interface fire exposure 61% were destroyed and 30% did not burn at all. The ignition of buildings by wind-driven firebrand showers and the starting of “spot fires” in unburned vegetation ahead of wildfires have been observed for some time. Empirically quantifying the exposure severity or describing how many firebrands of what size and over what duration and distance cause ignition problems of concern has not yet been possible. However, a unique opportunity to gather empirical firebrand data from an actual interface fire evolved in the days immediately following the Angora fire. Digital analyses of burn patterns from materials exposed to the Angora fire were conducted to determine firebrand size distributions. It is probable that some burn patterns were larger in area than the firebrands due to progressive combustion or melting, but it was assumed that the overall size distributions of burn pattern areas were representative of actual firebrand sizes. This assumption was investigated by exposing sections of materials collected in the Angora fire to wind driven firebrands generated in the laboratory using the unique NIST Dragon’s lofting and ignition research facility (NIST Dragon’s LAIR facility). The firebrand size distributions reported were compared to firebrand size distributions from experimental firebrand generation in both recent laboratory building ignition studies conducted by NIST and from historical firebrand field studies. Such data is needed to form the basis of effective and appropriate interface fire hazard mitigation measures as well as modeling fire spread. Comparisons are made to current wildfire protection building construction regulations and test standards. The most salient result of this study is documentation of the consistently small size of firebrands and the close correlation of these results with the sizes of experimentally generated firebrands. © Springer Science+Business Media, LLC (Outside the USA) 2012 |
collection_details |
GBV_USEFLAG_A SYSFLAG_A GBV_OLC SSG-OLC-UMW SSG-OLC-ARC SSG-OLC-TEC GBV_ILN_70 GBV_ILN_2014 |
container_issue |
1 |
title_short |
Characterizing Firebrand Exposure from Wildland–Urban Interface (WUI) Fires: Results from the 2007 Angora Fire |
url |
https://doi.org/10.1007/s10694-012-0295-4 |
remote_bool |
false |
author2 |
Foote, Ethan I. D. |
author2Str |
Foote, Ethan I. D. |
ppnlink |
130411485 |
mediatype_str_mv |
n |
isOA_txt |
false |
hochschulschrift_bool |
false |
doi_str |
10.1007/s10694-012-0295-4 |
up_date |
2024-07-03T16:05:06.122Z |
_version_ |
1803574529112408064 |
fullrecord_marcxml |
<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim"><record><leader>01000caa a22002652 4500</leader><controlfield tag="001">OLC2072760380</controlfield><controlfield tag="003">DE-627</controlfield><controlfield tag="005">20230503060628.0</controlfield><controlfield tag="007">tu</controlfield><controlfield tag="008">200819s2012 xx ||||| 00| ||eng c</controlfield><datafield tag="024" ind1="7" ind2=" "><subfield code="a">10.1007/s10694-012-0295-4</subfield><subfield code="2">doi</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-627)OLC2072760380</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-He213)s10694-012-0295-4-p</subfield></datafield><datafield tag="040" ind1=" " ind2=" "><subfield code="a">DE-627</subfield><subfield code="b">ger</subfield><subfield code="c">DE-627</subfield><subfield code="e">rakwb</subfield></datafield><datafield tag="041" ind1=" " ind2=" "><subfield code="a">eng</subfield></datafield><datafield tag="082" ind1="0" ind2="4"><subfield code="a">690</subfield><subfield code="a">620</subfield><subfield code="q">VZ</subfield></datafield><datafield tag="100" ind1="1" ind2=" "><subfield code="a">Manzello, Samuel L.</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="245" ind1="1" ind2="0"><subfield code="a">Characterizing Firebrand Exposure from Wildland–Urban Interface (WUI) Fires: Results from the 2007 Angora Fire</subfield></datafield><datafield tag="264" ind1=" " ind2="1"><subfield code="c">2012</subfield></datafield><datafield tag="336" ind1=" " ind2=" "><subfield code="a">Text</subfield><subfield code="b">txt</subfield><subfield code="2">rdacontent</subfield></datafield><datafield tag="337" ind1=" " ind2=" "><subfield code="a">ohne Hilfsmittel zu benutzen</subfield><subfield code="b">n</subfield><subfield code="2">rdamedia</subfield></datafield><datafield tag="338" ind1=" " ind2=" "><subfield code="a">Band</subfield><subfield code="b">nc</subfield><subfield code="2">rdacarrier</subfield></datafield><datafield tag="500" ind1=" " ind2=" "><subfield code="a">© Springer Science+Business Media, LLC (Outside the USA) 2012</subfield></datafield><datafield tag="520" ind1=" " ind2=" "><subfield code="a">Abstract This study examines the size distribution and other characteristics of firebrand exposure during the 2007 Angora fire, a severe wildland–urban interface fire in California. Of the 401 houses that received direct interface fire exposure 61% were destroyed and 30% did not burn at all. The ignition of buildings by wind-driven firebrand showers and the starting of “spot fires” in unburned vegetation ahead of wildfires have been observed for some time. Empirically quantifying the exposure severity or describing how many firebrands of what size and over what duration and distance cause ignition problems of concern has not yet been possible. However, a unique opportunity to gather empirical firebrand data from an actual interface fire evolved in the days immediately following the Angora fire. Digital analyses of burn patterns from materials exposed to the Angora fire were conducted to determine firebrand size distributions. It is probable that some burn patterns were larger in area than the firebrands due to progressive combustion or melting, but it was assumed that the overall size distributions of burn pattern areas were representative of actual firebrand sizes. This assumption was investigated by exposing sections of materials collected in the Angora fire to wind driven firebrands generated in the laboratory using the unique NIST Dragon’s lofting and ignition research facility (NIST Dragon’s LAIR facility). The firebrand size distributions reported were compared to firebrand size distributions from experimental firebrand generation in both recent laboratory building ignition studies conducted by NIST and from historical firebrand field studies. Such data is needed to form the basis of effective and appropriate interface fire hazard mitigation measures as well as modeling fire spread. Comparisons are made to current wildfire protection building construction regulations and test standards. The most salient result of this study is documentation of the consistently small size of firebrands and the close correlation of these results with the sizes of experimentally generated firebrands.</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Firebrands</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Wildland–urban interface (WUI) fire</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Firebrand exposure</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Foote, Ethan I. D.</subfield><subfield code="4">aut</subfield></datafield><datafield tag="773" ind1="0" ind2="8"><subfield code="i">Enthalten in</subfield><subfield code="t">Fire technology</subfield><subfield code="d">Springer US, 1965</subfield><subfield code="g">50(2012), 1 vom: 22. Sept., Seite 105-124</subfield><subfield code="w">(DE-627)130411485</subfield><subfield code="w">(DE-600)622603-6</subfield><subfield code="w">(DE-576)028033434</subfield><subfield code="x">0015-2684</subfield><subfield code="7">nnns</subfield></datafield><datafield tag="773" ind1="1" ind2="8"><subfield code="g">volume:50</subfield><subfield code="g">year:2012</subfield><subfield code="g">number:1</subfield><subfield code="g">day:22</subfield><subfield code="g">month:09</subfield><subfield code="g">pages:105-124</subfield></datafield><datafield tag="856" ind1="4" ind2="1"><subfield code="u">https://doi.org/10.1007/s10694-012-0295-4</subfield><subfield code="z">lizenzpflichtig</subfield><subfield code="3">Volltext</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_USEFLAG_A</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">SYSFLAG_A</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_OLC</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">SSG-OLC-UMW</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">SSG-OLC-ARC</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">SSG-OLC-TEC</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_70</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2014</subfield></datafield><datafield tag="951" ind1=" " ind2=" "><subfield code="a">AR</subfield></datafield><datafield tag="952" ind1=" " ind2=" "><subfield code="d">50</subfield><subfield code="j">2012</subfield><subfield code="e">1</subfield><subfield code="b">22</subfield><subfield code="c">09</subfield><subfield code="h">105-124</subfield></datafield></record></collection>
|
score |
7.401531 |