Simultaneous time- and spectrum-resolved multifocal multiphoton microscopy
Abstract We present a novel multifocal multiphoton microscope that is based on a sampling imaging technique using a microlens array, a prism for two-dimensionalspectral dispersion, and a specially designed streak camera to provide simultaneous time- and spectrum-resolved fluorescence microscopy. We...
Ausführliche Beschreibung
Autor*in: |
Liu, L. [verfasserIn] |
---|
Format: |
Artikel |
---|---|
Sprache: |
Englisch |
Erschienen: |
2006 |
---|
Schlagwörter: |
---|
Systematik: |
|
---|
Anmerkung: |
© Springer-Verlag 2006 |
---|
Übergeordnetes Werk: |
Enthalten in: Applied physics. B, Lasers and optics - Springer-Verlag, 1981, 84(2006), 3 vom: 28. Juni, Seite 379-383 |
---|---|
Übergeordnetes Werk: |
volume:84 ; year:2006 ; number:3 ; day:28 ; month:06 ; pages:379-383 |
Links: |
---|
DOI / URN: |
10.1007/s00340-006-2314-y |
---|
Katalog-ID: |
OLC2074284985 |
---|
LEADER | 01000caa a22002652 4500 | ||
---|---|---|---|
001 | OLC2074284985 | ||
003 | DE-627 | ||
005 | 20230331133011.0 | ||
007 | tu | ||
008 | 200819s2006 xx ||||| 00| ||eng c | ||
024 | 7 | |a 10.1007/s00340-006-2314-y |2 doi | |
035 | |a (DE-627)OLC2074284985 | ||
035 | |a (DE-He213)s00340-006-2314-y-p | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
082 | 0 | 4 | |a 530 |a 620 |q VZ |
082 | 0 | 4 | |a 530 |q VZ |
084 | |a UA 9001 |q VZ |2 rvk | ||
100 | 1 | |a Liu, L. |e verfasserin |4 aut | |
245 | 1 | 0 | |a Simultaneous time- and spectrum-resolved multifocal multiphoton microscopy |
264 | 1 | |c 2006 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a ohne Hilfsmittel zu benutzen |b n |2 rdamedia | ||
338 | |a Band |b nc |2 rdacarrier | ||
500 | |a © Springer-Verlag 2006 | ||
520 | |a Abstract We present a novel multifocal multiphoton microscope that is based on a sampling imaging technique using a microlens array, a prism for two-dimensionalspectral dispersion, and a specially designed streak camera to provide simultaneous time- and spectrum-resolved fluorescence microscopy. We split the near-infrared light of a mode-locked titanium:sapphire femtosecond laser into an array of beams that are transformed into an array of high-aperture foci at the sample. A time- and spectrum-resolved image of 3×3 foci on the sample can be obtained with a snapshot. By translating the sample stage laterally and axially and implementing a dedicated image reconstruction algorithm in the control system of the instrument, we demonstrate the acquisition of a five-dimensional data set combining lifetime and spectral resolutions in biological fluorescence imaging. | ||
650 | 4 | |a Sample Stage | |
650 | 4 | |a Streak Camera | |
650 | 4 | |a Microlens Array | |
650 | 4 | |a Tissue Slide | |
650 | 4 | |a Simultaneous Time | |
700 | 1 | |a Qu, J. |4 aut | |
700 | 1 | |a Lin, Z. |4 aut | |
700 | 1 | |a Wang, L. |4 aut | |
700 | 1 | |a Fu, Z. |4 aut | |
700 | 1 | |a Guo, B. |4 aut | |
700 | 1 | |a Niu, H. |4 aut | |
773 | 0 | 8 | |i Enthalten in |t Applied physics. B, Lasers and optics |d Springer-Verlag, 1981 |g 84(2006), 3 vom: 28. Juni, Seite 379-383 |w (DE-627)130297682 |w (DE-600)579693-3 |w (DE-576)015877272 |x 0946-2171 |7 nnns |
773 | 1 | 8 | |g volume:84 |g year:2006 |g number:3 |g day:28 |g month:06 |g pages:379-383 |
856 | 4 | 1 | |u https://doi.org/10.1007/s00340-006-2314-y |z lizenzpflichtig |3 Volltext |
912 | |a GBV_USEFLAG_A | ||
912 | |a SYSFLAG_A | ||
912 | |a GBV_OLC | ||
912 | |a SSG-OLC-PHY | ||
912 | |a GBV_ILN_21 | ||
912 | |a GBV_ILN_22 | ||
912 | |a GBV_ILN_24 | ||
912 | |a GBV_ILN_30 | ||
912 | |a GBV_ILN_31 | ||
912 | |a GBV_ILN_40 | ||
912 | |a GBV_ILN_60 | ||
912 | |a GBV_ILN_70 | ||
912 | |a GBV_ILN_130 | ||
912 | |a GBV_ILN_170 | ||
912 | |a GBV_ILN_285 | ||
912 | |a GBV_ILN_602 | ||
912 | |a GBV_ILN_2010 | ||
912 | |a GBV_ILN_2018 | ||
912 | |a GBV_ILN_2021 | ||
912 | |a GBV_ILN_4036 | ||
912 | |a GBV_ILN_4116 | ||
912 | |a GBV_ILN_4126 | ||
912 | |a GBV_ILN_4266 | ||
912 | |a GBV_ILN_4277 | ||
912 | |a GBV_ILN_4306 | ||
912 | |a GBV_ILN_4307 | ||
912 | |a GBV_ILN_4313 | ||
912 | |a GBV_ILN_4323 | ||
936 | r | v | |a UA 9001 |
951 | |a AR | ||
952 | |d 84 |j 2006 |e 3 |b 28 |c 06 |h 379-383 |
author_variant |
l l ll j q jq z l zl l w lw z f zf b g bg h n hn |
---|---|
matchkey_str |
article:09462171:2006----::iutnosienseturslemlioaml |
hierarchy_sort_str |
2006 |
publishDate |
2006 |
allfields |
10.1007/s00340-006-2314-y doi (DE-627)OLC2074284985 (DE-He213)s00340-006-2314-y-p DE-627 ger DE-627 rakwb eng 530 620 VZ 530 VZ UA 9001 VZ rvk Liu, L. verfasserin aut Simultaneous time- and spectrum-resolved multifocal multiphoton microscopy 2006 Text txt rdacontent ohne Hilfsmittel zu benutzen n rdamedia Band nc rdacarrier © Springer-Verlag 2006 Abstract We present a novel multifocal multiphoton microscope that is based on a sampling imaging technique using a microlens array, a prism for two-dimensionalspectral dispersion, and a specially designed streak camera to provide simultaneous time- and spectrum-resolved fluorescence microscopy. We split the near-infrared light of a mode-locked titanium:sapphire femtosecond laser into an array of beams that are transformed into an array of high-aperture foci at the sample. A time- and spectrum-resolved image of 3×3 foci on the sample can be obtained with a snapshot. By translating the sample stage laterally and axially and implementing a dedicated image reconstruction algorithm in the control system of the instrument, we demonstrate the acquisition of a five-dimensional data set combining lifetime and spectral resolutions in biological fluorescence imaging. Sample Stage Streak Camera Microlens Array Tissue Slide Simultaneous Time Qu, J. aut Lin, Z. aut Wang, L. aut Fu, Z. aut Guo, B. aut Niu, H. aut Enthalten in Applied physics. B, Lasers and optics Springer-Verlag, 1981 84(2006), 3 vom: 28. Juni, Seite 379-383 (DE-627)130297682 (DE-600)579693-3 (DE-576)015877272 0946-2171 nnns volume:84 year:2006 number:3 day:28 month:06 pages:379-383 https://doi.org/10.1007/s00340-006-2314-y lizenzpflichtig Volltext GBV_USEFLAG_A SYSFLAG_A GBV_OLC SSG-OLC-PHY GBV_ILN_21 GBV_ILN_22 GBV_ILN_24 GBV_ILN_30 GBV_ILN_31 GBV_ILN_40 GBV_ILN_60 GBV_ILN_70 GBV_ILN_130 GBV_ILN_170 GBV_ILN_285 GBV_ILN_602 GBV_ILN_2010 GBV_ILN_2018 GBV_ILN_2021 GBV_ILN_4036 GBV_ILN_4116 GBV_ILN_4126 GBV_ILN_4266 GBV_ILN_4277 GBV_ILN_4306 GBV_ILN_4307 GBV_ILN_4313 GBV_ILN_4323 UA 9001 AR 84 2006 3 28 06 379-383 |
spelling |
10.1007/s00340-006-2314-y doi (DE-627)OLC2074284985 (DE-He213)s00340-006-2314-y-p DE-627 ger DE-627 rakwb eng 530 620 VZ 530 VZ UA 9001 VZ rvk Liu, L. verfasserin aut Simultaneous time- and spectrum-resolved multifocal multiphoton microscopy 2006 Text txt rdacontent ohne Hilfsmittel zu benutzen n rdamedia Band nc rdacarrier © Springer-Verlag 2006 Abstract We present a novel multifocal multiphoton microscope that is based on a sampling imaging technique using a microlens array, a prism for two-dimensionalspectral dispersion, and a specially designed streak camera to provide simultaneous time- and spectrum-resolved fluorescence microscopy. We split the near-infrared light of a mode-locked titanium:sapphire femtosecond laser into an array of beams that are transformed into an array of high-aperture foci at the sample. A time- and spectrum-resolved image of 3×3 foci on the sample can be obtained with a snapshot. By translating the sample stage laterally and axially and implementing a dedicated image reconstruction algorithm in the control system of the instrument, we demonstrate the acquisition of a five-dimensional data set combining lifetime and spectral resolutions in biological fluorescence imaging. Sample Stage Streak Camera Microlens Array Tissue Slide Simultaneous Time Qu, J. aut Lin, Z. aut Wang, L. aut Fu, Z. aut Guo, B. aut Niu, H. aut Enthalten in Applied physics. B, Lasers and optics Springer-Verlag, 1981 84(2006), 3 vom: 28. Juni, Seite 379-383 (DE-627)130297682 (DE-600)579693-3 (DE-576)015877272 0946-2171 nnns volume:84 year:2006 number:3 day:28 month:06 pages:379-383 https://doi.org/10.1007/s00340-006-2314-y lizenzpflichtig Volltext GBV_USEFLAG_A SYSFLAG_A GBV_OLC SSG-OLC-PHY GBV_ILN_21 GBV_ILN_22 GBV_ILN_24 GBV_ILN_30 GBV_ILN_31 GBV_ILN_40 GBV_ILN_60 GBV_ILN_70 GBV_ILN_130 GBV_ILN_170 GBV_ILN_285 GBV_ILN_602 GBV_ILN_2010 GBV_ILN_2018 GBV_ILN_2021 GBV_ILN_4036 GBV_ILN_4116 GBV_ILN_4126 GBV_ILN_4266 GBV_ILN_4277 GBV_ILN_4306 GBV_ILN_4307 GBV_ILN_4313 GBV_ILN_4323 UA 9001 AR 84 2006 3 28 06 379-383 |
allfields_unstemmed |
10.1007/s00340-006-2314-y doi (DE-627)OLC2074284985 (DE-He213)s00340-006-2314-y-p DE-627 ger DE-627 rakwb eng 530 620 VZ 530 VZ UA 9001 VZ rvk Liu, L. verfasserin aut Simultaneous time- and spectrum-resolved multifocal multiphoton microscopy 2006 Text txt rdacontent ohne Hilfsmittel zu benutzen n rdamedia Band nc rdacarrier © Springer-Verlag 2006 Abstract We present a novel multifocal multiphoton microscope that is based on a sampling imaging technique using a microlens array, a prism for two-dimensionalspectral dispersion, and a specially designed streak camera to provide simultaneous time- and spectrum-resolved fluorescence microscopy. We split the near-infrared light of a mode-locked titanium:sapphire femtosecond laser into an array of beams that are transformed into an array of high-aperture foci at the sample. A time- and spectrum-resolved image of 3×3 foci on the sample can be obtained with a snapshot. By translating the sample stage laterally and axially and implementing a dedicated image reconstruction algorithm in the control system of the instrument, we demonstrate the acquisition of a five-dimensional data set combining lifetime and spectral resolutions in biological fluorescence imaging. Sample Stage Streak Camera Microlens Array Tissue Slide Simultaneous Time Qu, J. aut Lin, Z. aut Wang, L. aut Fu, Z. aut Guo, B. aut Niu, H. aut Enthalten in Applied physics. B, Lasers and optics Springer-Verlag, 1981 84(2006), 3 vom: 28. Juni, Seite 379-383 (DE-627)130297682 (DE-600)579693-3 (DE-576)015877272 0946-2171 nnns volume:84 year:2006 number:3 day:28 month:06 pages:379-383 https://doi.org/10.1007/s00340-006-2314-y lizenzpflichtig Volltext GBV_USEFLAG_A SYSFLAG_A GBV_OLC SSG-OLC-PHY GBV_ILN_21 GBV_ILN_22 GBV_ILN_24 GBV_ILN_30 GBV_ILN_31 GBV_ILN_40 GBV_ILN_60 GBV_ILN_70 GBV_ILN_130 GBV_ILN_170 GBV_ILN_285 GBV_ILN_602 GBV_ILN_2010 GBV_ILN_2018 GBV_ILN_2021 GBV_ILN_4036 GBV_ILN_4116 GBV_ILN_4126 GBV_ILN_4266 GBV_ILN_4277 GBV_ILN_4306 GBV_ILN_4307 GBV_ILN_4313 GBV_ILN_4323 UA 9001 AR 84 2006 3 28 06 379-383 |
allfieldsGer |
10.1007/s00340-006-2314-y doi (DE-627)OLC2074284985 (DE-He213)s00340-006-2314-y-p DE-627 ger DE-627 rakwb eng 530 620 VZ 530 VZ UA 9001 VZ rvk Liu, L. verfasserin aut Simultaneous time- and spectrum-resolved multifocal multiphoton microscopy 2006 Text txt rdacontent ohne Hilfsmittel zu benutzen n rdamedia Band nc rdacarrier © Springer-Verlag 2006 Abstract We present a novel multifocal multiphoton microscope that is based on a sampling imaging technique using a microlens array, a prism for two-dimensionalspectral dispersion, and a specially designed streak camera to provide simultaneous time- and spectrum-resolved fluorescence microscopy. We split the near-infrared light of a mode-locked titanium:sapphire femtosecond laser into an array of beams that are transformed into an array of high-aperture foci at the sample. A time- and spectrum-resolved image of 3×3 foci on the sample can be obtained with a snapshot. By translating the sample stage laterally and axially and implementing a dedicated image reconstruction algorithm in the control system of the instrument, we demonstrate the acquisition of a five-dimensional data set combining lifetime and spectral resolutions in biological fluorescence imaging. Sample Stage Streak Camera Microlens Array Tissue Slide Simultaneous Time Qu, J. aut Lin, Z. aut Wang, L. aut Fu, Z. aut Guo, B. aut Niu, H. aut Enthalten in Applied physics. B, Lasers and optics Springer-Verlag, 1981 84(2006), 3 vom: 28. Juni, Seite 379-383 (DE-627)130297682 (DE-600)579693-3 (DE-576)015877272 0946-2171 nnns volume:84 year:2006 number:3 day:28 month:06 pages:379-383 https://doi.org/10.1007/s00340-006-2314-y lizenzpflichtig Volltext GBV_USEFLAG_A SYSFLAG_A GBV_OLC SSG-OLC-PHY GBV_ILN_21 GBV_ILN_22 GBV_ILN_24 GBV_ILN_30 GBV_ILN_31 GBV_ILN_40 GBV_ILN_60 GBV_ILN_70 GBV_ILN_130 GBV_ILN_170 GBV_ILN_285 GBV_ILN_602 GBV_ILN_2010 GBV_ILN_2018 GBV_ILN_2021 GBV_ILN_4036 GBV_ILN_4116 GBV_ILN_4126 GBV_ILN_4266 GBV_ILN_4277 GBV_ILN_4306 GBV_ILN_4307 GBV_ILN_4313 GBV_ILN_4323 UA 9001 AR 84 2006 3 28 06 379-383 |
allfieldsSound |
10.1007/s00340-006-2314-y doi (DE-627)OLC2074284985 (DE-He213)s00340-006-2314-y-p DE-627 ger DE-627 rakwb eng 530 620 VZ 530 VZ UA 9001 VZ rvk Liu, L. verfasserin aut Simultaneous time- and spectrum-resolved multifocal multiphoton microscopy 2006 Text txt rdacontent ohne Hilfsmittel zu benutzen n rdamedia Band nc rdacarrier © Springer-Verlag 2006 Abstract We present a novel multifocal multiphoton microscope that is based on a sampling imaging technique using a microlens array, a prism for two-dimensionalspectral dispersion, and a specially designed streak camera to provide simultaneous time- and spectrum-resolved fluorescence microscopy. We split the near-infrared light of a mode-locked titanium:sapphire femtosecond laser into an array of beams that are transformed into an array of high-aperture foci at the sample. A time- and spectrum-resolved image of 3×3 foci on the sample can be obtained with a snapshot. By translating the sample stage laterally and axially and implementing a dedicated image reconstruction algorithm in the control system of the instrument, we demonstrate the acquisition of a five-dimensional data set combining lifetime and spectral resolutions in biological fluorescence imaging. Sample Stage Streak Camera Microlens Array Tissue Slide Simultaneous Time Qu, J. aut Lin, Z. aut Wang, L. aut Fu, Z. aut Guo, B. aut Niu, H. aut Enthalten in Applied physics. B, Lasers and optics Springer-Verlag, 1981 84(2006), 3 vom: 28. Juni, Seite 379-383 (DE-627)130297682 (DE-600)579693-3 (DE-576)015877272 0946-2171 nnns volume:84 year:2006 number:3 day:28 month:06 pages:379-383 https://doi.org/10.1007/s00340-006-2314-y lizenzpflichtig Volltext GBV_USEFLAG_A SYSFLAG_A GBV_OLC SSG-OLC-PHY GBV_ILN_21 GBV_ILN_22 GBV_ILN_24 GBV_ILN_30 GBV_ILN_31 GBV_ILN_40 GBV_ILN_60 GBV_ILN_70 GBV_ILN_130 GBV_ILN_170 GBV_ILN_285 GBV_ILN_602 GBV_ILN_2010 GBV_ILN_2018 GBV_ILN_2021 GBV_ILN_4036 GBV_ILN_4116 GBV_ILN_4126 GBV_ILN_4266 GBV_ILN_4277 GBV_ILN_4306 GBV_ILN_4307 GBV_ILN_4313 GBV_ILN_4323 UA 9001 AR 84 2006 3 28 06 379-383 |
language |
English |
source |
Enthalten in Applied physics. B, Lasers and optics 84(2006), 3 vom: 28. Juni, Seite 379-383 volume:84 year:2006 number:3 day:28 month:06 pages:379-383 |
sourceStr |
Enthalten in Applied physics. B, Lasers and optics 84(2006), 3 vom: 28. Juni, Seite 379-383 volume:84 year:2006 number:3 day:28 month:06 pages:379-383 |
format_phy_str_mv |
Article |
institution |
findex.gbv.de |
topic_facet |
Sample Stage Streak Camera Microlens Array Tissue Slide Simultaneous Time |
dewey-raw |
530 |
isfreeaccess_bool |
false |
container_title |
Applied physics. B, Lasers and optics |
authorswithroles_txt_mv |
Liu, L. @@aut@@ Qu, J. @@aut@@ Lin, Z. @@aut@@ Wang, L. @@aut@@ Fu, Z. @@aut@@ Guo, B. @@aut@@ Niu, H. @@aut@@ |
publishDateDaySort_date |
2006-06-28T00:00:00Z |
hierarchy_top_id |
130297682 |
dewey-sort |
3530 |
id |
OLC2074284985 |
language_de |
englisch |
fullrecord |
<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim"><record><leader>01000caa a22002652 4500</leader><controlfield tag="001">OLC2074284985</controlfield><controlfield tag="003">DE-627</controlfield><controlfield tag="005">20230331133011.0</controlfield><controlfield tag="007">tu</controlfield><controlfield tag="008">200819s2006 xx ||||| 00| ||eng c</controlfield><datafield tag="024" ind1="7" ind2=" "><subfield code="a">10.1007/s00340-006-2314-y</subfield><subfield code="2">doi</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-627)OLC2074284985</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-He213)s00340-006-2314-y-p</subfield></datafield><datafield tag="040" ind1=" " ind2=" "><subfield code="a">DE-627</subfield><subfield code="b">ger</subfield><subfield code="c">DE-627</subfield><subfield code="e">rakwb</subfield></datafield><datafield tag="041" ind1=" " ind2=" "><subfield code="a">eng</subfield></datafield><datafield tag="082" ind1="0" ind2="4"><subfield code="a">530</subfield><subfield code="a">620</subfield><subfield code="q">VZ</subfield></datafield><datafield tag="082" ind1="0" ind2="4"><subfield code="a">530</subfield><subfield code="q">VZ</subfield></datafield><datafield tag="084" ind1=" " ind2=" "><subfield code="a">UA 9001</subfield><subfield code="q">VZ</subfield><subfield code="2">rvk</subfield></datafield><datafield tag="100" ind1="1" ind2=" "><subfield code="a">Liu, L.</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="245" ind1="1" ind2="0"><subfield code="a">Simultaneous time- and spectrum-resolved multifocal multiphoton microscopy</subfield></datafield><datafield tag="264" ind1=" " ind2="1"><subfield code="c">2006</subfield></datafield><datafield tag="336" ind1=" " ind2=" "><subfield code="a">Text</subfield><subfield code="b">txt</subfield><subfield code="2">rdacontent</subfield></datafield><datafield tag="337" ind1=" " ind2=" "><subfield code="a">ohne Hilfsmittel zu benutzen</subfield><subfield code="b">n</subfield><subfield code="2">rdamedia</subfield></datafield><datafield tag="338" ind1=" " ind2=" "><subfield code="a">Band</subfield><subfield code="b">nc</subfield><subfield code="2">rdacarrier</subfield></datafield><datafield tag="500" ind1=" " ind2=" "><subfield code="a">© Springer-Verlag 2006</subfield></datafield><datafield tag="520" ind1=" " ind2=" "><subfield code="a">Abstract We present a novel multifocal multiphoton microscope that is based on a sampling imaging technique using a microlens array, a prism for two-dimensionalspectral dispersion, and a specially designed streak camera to provide simultaneous time- and spectrum-resolved fluorescence microscopy. We split the near-infrared light of a mode-locked titanium:sapphire femtosecond laser into an array of beams that are transformed into an array of high-aperture foci at the sample. A time- and spectrum-resolved image of 3×3 foci on the sample can be obtained with a snapshot. By translating the sample stage laterally and axially and implementing a dedicated image reconstruction algorithm in the control system of the instrument, we demonstrate the acquisition of a five-dimensional data set combining lifetime and spectral resolutions in biological fluorescence imaging.</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Sample Stage</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Streak Camera</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Microlens Array</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Tissue Slide</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Simultaneous Time</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Qu, J.</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Lin, Z.</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Wang, L.</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Fu, Z.</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Guo, B.</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Niu, H.</subfield><subfield code="4">aut</subfield></datafield><datafield tag="773" ind1="0" ind2="8"><subfield code="i">Enthalten in</subfield><subfield code="t">Applied physics. B, Lasers and optics</subfield><subfield code="d">Springer-Verlag, 1981</subfield><subfield code="g">84(2006), 3 vom: 28. Juni, Seite 379-383</subfield><subfield code="w">(DE-627)130297682</subfield><subfield code="w">(DE-600)579693-3</subfield><subfield code="w">(DE-576)015877272</subfield><subfield code="x">0946-2171</subfield><subfield code="7">nnns</subfield></datafield><datafield tag="773" ind1="1" ind2="8"><subfield code="g">volume:84</subfield><subfield code="g">year:2006</subfield><subfield code="g">number:3</subfield><subfield code="g">day:28</subfield><subfield code="g">month:06</subfield><subfield code="g">pages:379-383</subfield></datafield><datafield tag="856" ind1="4" ind2="1"><subfield code="u">https://doi.org/10.1007/s00340-006-2314-y</subfield><subfield code="z">lizenzpflichtig</subfield><subfield code="3">Volltext</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_USEFLAG_A</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">SYSFLAG_A</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_OLC</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">SSG-OLC-PHY</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_21</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_22</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_24</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_30</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_31</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_40</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_60</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_70</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_130</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_170</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_285</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_602</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2010</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2018</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2021</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4036</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4116</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4126</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4266</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4277</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4306</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4307</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4313</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4323</subfield></datafield><datafield tag="936" ind1="r" ind2="v"><subfield code="a">UA 9001</subfield></datafield><datafield tag="951" ind1=" " ind2=" "><subfield code="a">AR</subfield></datafield><datafield tag="952" ind1=" " ind2=" "><subfield code="d">84</subfield><subfield code="j">2006</subfield><subfield code="e">3</subfield><subfield code="b">28</subfield><subfield code="c">06</subfield><subfield code="h">379-383</subfield></datafield></record></collection>
|
author |
Liu, L. |
spellingShingle |
Liu, L. ddc 530 rvk UA 9001 misc Sample Stage misc Streak Camera misc Microlens Array misc Tissue Slide misc Simultaneous Time Simultaneous time- and spectrum-resolved multifocal multiphoton microscopy |
authorStr |
Liu, L. |
ppnlink_with_tag_str_mv |
@@773@@(DE-627)130297682 |
format |
Article |
dewey-ones |
530 - Physics 620 - Engineering & allied operations |
delete_txt_mv |
keep |
author_role |
aut aut aut aut aut aut aut |
collection |
OLC |
remote_str |
false |
illustrated |
Not Illustrated |
issn |
0946-2171 |
topic_title |
530 620 VZ 530 VZ UA 9001 VZ rvk Simultaneous time- and spectrum-resolved multifocal multiphoton microscopy Sample Stage Streak Camera Microlens Array Tissue Slide Simultaneous Time |
topic |
ddc 530 rvk UA 9001 misc Sample Stage misc Streak Camera misc Microlens Array misc Tissue Slide misc Simultaneous Time |
topic_unstemmed |
ddc 530 rvk UA 9001 misc Sample Stage misc Streak Camera misc Microlens Array misc Tissue Slide misc Simultaneous Time |
topic_browse |
ddc 530 rvk UA 9001 misc Sample Stage misc Streak Camera misc Microlens Array misc Tissue Slide misc Simultaneous Time |
format_facet |
Aufsätze Gedruckte Aufsätze |
format_main_str_mv |
Text Zeitschrift/Artikel |
carriertype_str_mv |
nc |
hierarchy_parent_title |
Applied physics. B, Lasers and optics |
hierarchy_parent_id |
130297682 |
dewey-tens |
530 - Physics 620 - Engineering |
hierarchy_top_title |
Applied physics. B, Lasers and optics |
isfreeaccess_txt |
false |
familylinks_str_mv |
(DE-627)130297682 (DE-600)579693-3 (DE-576)015877272 |
title |
Simultaneous time- and spectrum-resolved multifocal multiphoton microscopy |
ctrlnum |
(DE-627)OLC2074284985 (DE-He213)s00340-006-2314-y-p |
title_full |
Simultaneous time- and spectrum-resolved multifocal multiphoton microscopy |
author_sort |
Liu, L. |
journal |
Applied physics. B, Lasers and optics |
journalStr |
Applied physics. B, Lasers and optics |
lang_code |
eng |
isOA_bool |
false |
dewey-hundreds |
500 - Science 600 - Technology |
recordtype |
marc |
publishDateSort |
2006 |
contenttype_str_mv |
txt |
container_start_page |
379 |
author_browse |
Liu, L. Qu, J. Lin, Z. Wang, L. Fu, Z. Guo, B. Niu, H. |
container_volume |
84 |
class |
530 620 VZ 530 VZ UA 9001 VZ rvk |
format_se |
Aufsätze |
author-letter |
Liu, L. |
doi_str_mv |
10.1007/s00340-006-2314-y |
dewey-full |
530 620 |
title_sort |
simultaneous time- and spectrum-resolved multifocal multiphoton microscopy |
title_auth |
Simultaneous time- and spectrum-resolved multifocal multiphoton microscopy |
abstract |
Abstract We present a novel multifocal multiphoton microscope that is based on a sampling imaging technique using a microlens array, a prism for two-dimensionalspectral dispersion, and a specially designed streak camera to provide simultaneous time- and spectrum-resolved fluorescence microscopy. We split the near-infrared light of a mode-locked titanium:sapphire femtosecond laser into an array of beams that are transformed into an array of high-aperture foci at the sample. A time- and spectrum-resolved image of 3×3 foci on the sample can be obtained with a snapshot. By translating the sample stage laterally and axially and implementing a dedicated image reconstruction algorithm in the control system of the instrument, we demonstrate the acquisition of a five-dimensional data set combining lifetime and spectral resolutions in biological fluorescence imaging. © Springer-Verlag 2006 |
abstractGer |
Abstract We present a novel multifocal multiphoton microscope that is based on a sampling imaging technique using a microlens array, a prism for two-dimensionalspectral dispersion, and a specially designed streak camera to provide simultaneous time- and spectrum-resolved fluorescence microscopy. We split the near-infrared light of a mode-locked titanium:sapphire femtosecond laser into an array of beams that are transformed into an array of high-aperture foci at the sample. A time- and spectrum-resolved image of 3×3 foci on the sample can be obtained with a snapshot. By translating the sample stage laterally and axially and implementing a dedicated image reconstruction algorithm in the control system of the instrument, we demonstrate the acquisition of a five-dimensional data set combining lifetime and spectral resolutions in biological fluorescence imaging. © Springer-Verlag 2006 |
abstract_unstemmed |
Abstract We present a novel multifocal multiphoton microscope that is based on a sampling imaging technique using a microlens array, a prism for two-dimensionalspectral dispersion, and a specially designed streak camera to provide simultaneous time- and spectrum-resolved fluorescence microscopy. We split the near-infrared light of a mode-locked titanium:sapphire femtosecond laser into an array of beams that are transformed into an array of high-aperture foci at the sample. A time- and spectrum-resolved image of 3×3 foci on the sample can be obtained with a snapshot. By translating the sample stage laterally and axially and implementing a dedicated image reconstruction algorithm in the control system of the instrument, we demonstrate the acquisition of a five-dimensional data set combining lifetime and spectral resolutions in biological fluorescence imaging. © Springer-Verlag 2006 |
collection_details |
GBV_USEFLAG_A SYSFLAG_A GBV_OLC SSG-OLC-PHY GBV_ILN_21 GBV_ILN_22 GBV_ILN_24 GBV_ILN_30 GBV_ILN_31 GBV_ILN_40 GBV_ILN_60 GBV_ILN_70 GBV_ILN_130 GBV_ILN_170 GBV_ILN_285 GBV_ILN_602 GBV_ILN_2010 GBV_ILN_2018 GBV_ILN_2021 GBV_ILN_4036 GBV_ILN_4116 GBV_ILN_4126 GBV_ILN_4266 GBV_ILN_4277 GBV_ILN_4306 GBV_ILN_4307 GBV_ILN_4313 GBV_ILN_4323 |
container_issue |
3 |
title_short |
Simultaneous time- and spectrum-resolved multifocal multiphoton microscopy |
url |
https://doi.org/10.1007/s00340-006-2314-y |
remote_bool |
false |
author2 |
Qu, J. Lin, Z. Wang, L. Fu, Z. Guo, B. Niu, H. |
author2Str |
Qu, J. Lin, Z. Wang, L. Fu, Z. Guo, B. Niu, H. |
ppnlink |
130297682 |
mediatype_str_mv |
n |
isOA_txt |
false |
hochschulschrift_bool |
false |
doi_str |
10.1007/s00340-006-2314-y |
up_date |
2024-07-03T21:41:24.468Z |
_version_ |
1803595687626014721 |
fullrecord_marcxml |
<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim"><record><leader>01000caa a22002652 4500</leader><controlfield tag="001">OLC2074284985</controlfield><controlfield tag="003">DE-627</controlfield><controlfield tag="005">20230331133011.0</controlfield><controlfield tag="007">tu</controlfield><controlfield tag="008">200819s2006 xx ||||| 00| ||eng c</controlfield><datafield tag="024" ind1="7" ind2=" "><subfield code="a">10.1007/s00340-006-2314-y</subfield><subfield code="2">doi</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-627)OLC2074284985</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-He213)s00340-006-2314-y-p</subfield></datafield><datafield tag="040" ind1=" " ind2=" "><subfield code="a">DE-627</subfield><subfield code="b">ger</subfield><subfield code="c">DE-627</subfield><subfield code="e">rakwb</subfield></datafield><datafield tag="041" ind1=" " ind2=" "><subfield code="a">eng</subfield></datafield><datafield tag="082" ind1="0" ind2="4"><subfield code="a">530</subfield><subfield code="a">620</subfield><subfield code="q">VZ</subfield></datafield><datafield tag="082" ind1="0" ind2="4"><subfield code="a">530</subfield><subfield code="q">VZ</subfield></datafield><datafield tag="084" ind1=" " ind2=" "><subfield code="a">UA 9001</subfield><subfield code="q">VZ</subfield><subfield code="2">rvk</subfield></datafield><datafield tag="100" ind1="1" ind2=" "><subfield code="a">Liu, L.</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="245" ind1="1" ind2="0"><subfield code="a">Simultaneous time- and spectrum-resolved multifocal multiphoton microscopy</subfield></datafield><datafield tag="264" ind1=" " ind2="1"><subfield code="c">2006</subfield></datafield><datafield tag="336" ind1=" " ind2=" "><subfield code="a">Text</subfield><subfield code="b">txt</subfield><subfield code="2">rdacontent</subfield></datafield><datafield tag="337" ind1=" " ind2=" "><subfield code="a">ohne Hilfsmittel zu benutzen</subfield><subfield code="b">n</subfield><subfield code="2">rdamedia</subfield></datafield><datafield tag="338" ind1=" " ind2=" "><subfield code="a">Band</subfield><subfield code="b">nc</subfield><subfield code="2">rdacarrier</subfield></datafield><datafield tag="500" ind1=" " ind2=" "><subfield code="a">© Springer-Verlag 2006</subfield></datafield><datafield tag="520" ind1=" " ind2=" "><subfield code="a">Abstract We present a novel multifocal multiphoton microscope that is based on a sampling imaging technique using a microlens array, a prism for two-dimensionalspectral dispersion, and a specially designed streak camera to provide simultaneous time- and spectrum-resolved fluorescence microscopy. We split the near-infrared light of a mode-locked titanium:sapphire femtosecond laser into an array of beams that are transformed into an array of high-aperture foci at the sample. A time- and spectrum-resolved image of 3×3 foci on the sample can be obtained with a snapshot. By translating the sample stage laterally and axially and implementing a dedicated image reconstruction algorithm in the control system of the instrument, we demonstrate the acquisition of a five-dimensional data set combining lifetime and spectral resolutions in biological fluorescence imaging.</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Sample Stage</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Streak Camera</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Microlens Array</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Tissue Slide</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Simultaneous Time</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Qu, J.</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Lin, Z.</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Wang, L.</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Fu, Z.</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Guo, B.</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Niu, H.</subfield><subfield code="4">aut</subfield></datafield><datafield tag="773" ind1="0" ind2="8"><subfield code="i">Enthalten in</subfield><subfield code="t">Applied physics. B, Lasers and optics</subfield><subfield code="d">Springer-Verlag, 1981</subfield><subfield code="g">84(2006), 3 vom: 28. Juni, Seite 379-383</subfield><subfield code="w">(DE-627)130297682</subfield><subfield code="w">(DE-600)579693-3</subfield><subfield code="w">(DE-576)015877272</subfield><subfield code="x">0946-2171</subfield><subfield code="7">nnns</subfield></datafield><datafield tag="773" ind1="1" ind2="8"><subfield code="g">volume:84</subfield><subfield code="g">year:2006</subfield><subfield code="g">number:3</subfield><subfield code="g">day:28</subfield><subfield code="g">month:06</subfield><subfield code="g">pages:379-383</subfield></datafield><datafield tag="856" ind1="4" ind2="1"><subfield code="u">https://doi.org/10.1007/s00340-006-2314-y</subfield><subfield code="z">lizenzpflichtig</subfield><subfield code="3">Volltext</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_USEFLAG_A</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">SYSFLAG_A</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_OLC</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">SSG-OLC-PHY</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_21</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_22</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_24</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_30</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_31</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_40</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_60</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_70</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_130</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_170</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_285</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_602</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2010</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2018</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2021</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4036</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4116</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4126</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4266</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4277</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4306</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4307</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4313</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4323</subfield></datafield><datafield tag="936" ind1="r" ind2="v"><subfield code="a">UA 9001</subfield></datafield><datafield tag="951" ind1=" " ind2=" "><subfield code="a">AR</subfield></datafield><datafield tag="952" ind1=" " ind2=" "><subfield code="d">84</subfield><subfield code="j">2006</subfield><subfield code="e">3</subfield><subfield code="b">28</subfield><subfield code="c">06</subfield><subfield code="h">379-383</subfield></datafield></record></collection>
|
score |
7.401005 |