RF-coupling and cooling techniques of stored heavy ions
Abstract A tandem Penning trap system, the ISOLTRAP, is now used at the on-line mass separator ISOLDE at CERN, Geneva, for accurate mass measurements of short-lived nuclei. The mass of the stored ions is measured by the determination of the cyclotron frequency $ ω_{c} $=qB/m in theB=6 T magnetic fie...
Ausführliche Beschreibung
Autor*in: |
Savard, G. [verfasserIn] |
---|
Format: |
Artikel |
---|---|
Sprache: |
Englisch |
Erschienen: |
1993 |
---|
Schlagwörter: |
---|
Anmerkung: |
© J.C. Baltzer AG, Science Publishers 1993 |
---|
Übergeordnetes Werk: |
Enthalten in: Hyperfine interactions - Kluwer Academic Publishers, 1975, 81(1993), 1-4 vom: März, Seite 135-142 |
---|---|
Übergeordnetes Werk: |
volume:81 ; year:1993 ; number:1-4 ; month:03 ; pages:135-142 |
Links: |
---|
DOI / URN: |
10.1007/BF00567257 |
---|
Katalog-ID: |
OLC2076375856 |
---|
LEADER | 01000caa a22002652 4500 | ||
---|---|---|---|
001 | OLC2076375856 | ||
003 | DE-627 | ||
005 | 20230503073735.0 | ||
007 | tu | ||
008 | 200820s1993 xx ||||| 00| ||eng c | ||
024 | 7 | |a 10.1007/BF00567257 |2 doi | |
035 | |a (DE-627)OLC2076375856 | ||
035 | |a (DE-He213)BF00567257-p | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
082 | 0 | 4 | |a 530 |q VZ |
084 | |a 33.00 |2 bkl | ||
100 | 1 | |a Savard, G. |e verfasserin |4 aut | |
245 | 1 | 0 | |a RF-coupling and cooling techniques of stored heavy ions |
264 | 1 | |c 1993 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a ohne Hilfsmittel zu benutzen |b n |2 rdamedia | ||
338 | |a Band |b nc |2 rdacarrier | ||
500 | |a © J.C. Baltzer AG, Science Publishers 1993 | ||
520 | |a Abstract A tandem Penning trap system, the ISOLTRAP, is now used at the on-line mass separator ISOLDE at CERN, Geneva, for accurate mass measurements of short-lived nuclei. The mass of the stored ions is measured by the determination of the cyclotron frequency $ ω_{c} $=qB/m in theB=6 T magnetic field of the trap. A new technique has been developed and implemented to allow reliable high-efficiency loading of the trap with radioactive heavy ions. | ||
650 | 4 | |a Mass Measurement | |
650 | 4 | |a Accurate Mass | |
650 | 4 | |a Cyclotron Frequency | |
650 | 4 | |a Accurate Mass Measurement | |
650 | 4 | |a Mass Separator | |
773 | 0 | 8 | |i Enthalten in |t Hyperfine interactions |d Kluwer Academic Publishers, 1975 |g 81(1993), 1-4 vom: März, Seite 135-142 |w (DE-627)129438685 |w (DE-600)194471-X |w (DE-576)014809028 |x 0304-3843 |7 nnns |
773 | 1 | 8 | |g volume:81 |g year:1993 |g number:1-4 |g month:03 |g pages:135-142 |
856 | 4 | 1 | |u https://doi.org/10.1007/BF00567257 |z lizenzpflichtig |3 Volltext |
912 | |a GBV_USEFLAG_A | ||
912 | |a SYSFLAG_A | ||
912 | |a GBV_OLC | ||
912 | |a SSG-OLC-PHY | ||
912 | |a GBV_ILN_20 | ||
912 | |a GBV_ILN_22 | ||
912 | |a GBV_ILN_40 | ||
912 | |a GBV_ILN_70 | ||
912 | |a GBV_ILN_2279 | ||
912 | |a GBV_ILN_4012 | ||
912 | |a GBV_ILN_4046 | ||
936 | b | k | |a 33.00 |q VZ |
951 | |a AR | ||
952 | |d 81 |j 1993 |e 1-4 |c 03 |h 135-142 |
author_variant |
g s gs |
---|---|
matchkey_str |
article:03043843:1993----::fopigncoigehiusf |
hierarchy_sort_str |
1993 |
bklnumber |
33.00 |
publishDate |
1993 |
allfields |
10.1007/BF00567257 doi (DE-627)OLC2076375856 (DE-He213)BF00567257-p DE-627 ger DE-627 rakwb eng 530 VZ 33.00 bkl Savard, G. verfasserin aut RF-coupling and cooling techniques of stored heavy ions 1993 Text txt rdacontent ohne Hilfsmittel zu benutzen n rdamedia Band nc rdacarrier © J.C. Baltzer AG, Science Publishers 1993 Abstract A tandem Penning trap system, the ISOLTRAP, is now used at the on-line mass separator ISOLDE at CERN, Geneva, for accurate mass measurements of short-lived nuclei. The mass of the stored ions is measured by the determination of the cyclotron frequency $ ω_{c} $=qB/m in theB=6 T magnetic field of the trap. A new technique has been developed and implemented to allow reliable high-efficiency loading of the trap with radioactive heavy ions. Mass Measurement Accurate Mass Cyclotron Frequency Accurate Mass Measurement Mass Separator Enthalten in Hyperfine interactions Kluwer Academic Publishers, 1975 81(1993), 1-4 vom: März, Seite 135-142 (DE-627)129438685 (DE-600)194471-X (DE-576)014809028 0304-3843 nnns volume:81 year:1993 number:1-4 month:03 pages:135-142 https://doi.org/10.1007/BF00567257 lizenzpflichtig Volltext GBV_USEFLAG_A SYSFLAG_A GBV_OLC SSG-OLC-PHY GBV_ILN_20 GBV_ILN_22 GBV_ILN_40 GBV_ILN_70 GBV_ILN_2279 GBV_ILN_4012 GBV_ILN_4046 33.00 VZ AR 81 1993 1-4 03 135-142 |
spelling |
10.1007/BF00567257 doi (DE-627)OLC2076375856 (DE-He213)BF00567257-p DE-627 ger DE-627 rakwb eng 530 VZ 33.00 bkl Savard, G. verfasserin aut RF-coupling and cooling techniques of stored heavy ions 1993 Text txt rdacontent ohne Hilfsmittel zu benutzen n rdamedia Band nc rdacarrier © J.C. Baltzer AG, Science Publishers 1993 Abstract A tandem Penning trap system, the ISOLTRAP, is now used at the on-line mass separator ISOLDE at CERN, Geneva, for accurate mass measurements of short-lived nuclei. The mass of the stored ions is measured by the determination of the cyclotron frequency $ ω_{c} $=qB/m in theB=6 T magnetic field of the trap. A new technique has been developed and implemented to allow reliable high-efficiency loading of the trap with radioactive heavy ions. Mass Measurement Accurate Mass Cyclotron Frequency Accurate Mass Measurement Mass Separator Enthalten in Hyperfine interactions Kluwer Academic Publishers, 1975 81(1993), 1-4 vom: März, Seite 135-142 (DE-627)129438685 (DE-600)194471-X (DE-576)014809028 0304-3843 nnns volume:81 year:1993 number:1-4 month:03 pages:135-142 https://doi.org/10.1007/BF00567257 lizenzpflichtig Volltext GBV_USEFLAG_A SYSFLAG_A GBV_OLC SSG-OLC-PHY GBV_ILN_20 GBV_ILN_22 GBV_ILN_40 GBV_ILN_70 GBV_ILN_2279 GBV_ILN_4012 GBV_ILN_4046 33.00 VZ AR 81 1993 1-4 03 135-142 |
allfields_unstemmed |
10.1007/BF00567257 doi (DE-627)OLC2076375856 (DE-He213)BF00567257-p DE-627 ger DE-627 rakwb eng 530 VZ 33.00 bkl Savard, G. verfasserin aut RF-coupling and cooling techniques of stored heavy ions 1993 Text txt rdacontent ohne Hilfsmittel zu benutzen n rdamedia Band nc rdacarrier © J.C. Baltzer AG, Science Publishers 1993 Abstract A tandem Penning trap system, the ISOLTRAP, is now used at the on-line mass separator ISOLDE at CERN, Geneva, for accurate mass measurements of short-lived nuclei. The mass of the stored ions is measured by the determination of the cyclotron frequency $ ω_{c} $=qB/m in theB=6 T magnetic field of the trap. A new technique has been developed and implemented to allow reliable high-efficiency loading of the trap with radioactive heavy ions. Mass Measurement Accurate Mass Cyclotron Frequency Accurate Mass Measurement Mass Separator Enthalten in Hyperfine interactions Kluwer Academic Publishers, 1975 81(1993), 1-4 vom: März, Seite 135-142 (DE-627)129438685 (DE-600)194471-X (DE-576)014809028 0304-3843 nnns volume:81 year:1993 number:1-4 month:03 pages:135-142 https://doi.org/10.1007/BF00567257 lizenzpflichtig Volltext GBV_USEFLAG_A SYSFLAG_A GBV_OLC SSG-OLC-PHY GBV_ILN_20 GBV_ILN_22 GBV_ILN_40 GBV_ILN_70 GBV_ILN_2279 GBV_ILN_4012 GBV_ILN_4046 33.00 VZ AR 81 1993 1-4 03 135-142 |
allfieldsGer |
10.1007/BF00567257 doi (DE-627)OLC2076375856 (DE-He213)BF00567257-p DE-627 ger DE-627 rakwb eng 530 VZ 33.00 bkl Savard, G. verfasserin aut RF-coupling and cooling techniques of stored heavy ions 1993 Text txt rdacontent ohne Hilfsmittel zu benutzen n rdamedia Band nc rdacarrier © J.C. Baltzer AG, Science Publishers 1993 Abstract A tandem Penning trap system, the ISOLTRAP, is now used at the on-line mass separator ISOLDE at CERN, Geneva, for accurate mass measurements of short-lived nuclei. The mass of the stored ions is measured by the determination of the cyclotron frequency $ ω_{c} $=qB/m in theB=6 T magnetic field of the trap. A new technique has been developed and implemented to allow reliable high-efficiency loading of the trap with radioactive heavy ions. Mass Measurement Accurate Mass Cyclotron Frequency Accurate Mass Measurement Mass Separator Enthalten in Hyperfine interactions Kluwer Academic Publishers, 1975 81(1993), 1-4 vom: März, Seite 135-142 (DE-627)129438685 (DE-600)194471-X (DE-576)014809028 0304-3843 nnns volume:81 year:1993 number:1-4 month:03 pages:135-142 https://doi.org/10.1007/BF00567257 lizenzpflichtig Volltext GBV_USEFLAG_A SYSFLAG_A GBV_OLC SSG-OLC-PHY GBV_ILN_20 GBV_ILN_22 GBV_ILN_40 GBV_ILN_70 GBV_ILN_2279 GBV_ILN_4012 GBV_ILN_4046 33.00 VZ AR 81 1993 1-4 03 135-142 |
allfieldsSound |
10.1007/BF00567257 doi (DE-627)OLC2076375856 (DE-He213)BF00567257-p DE-627 ger DE-627 rakwb eng 530 VZ 33.00 bkl Savard, G. verfasserin aut RF-coupling and cooling techniques of stored heavy ions 1993 Text txt rdacontent ohne Hilfsmittel zu benutzen n rdamedia Band nc rdacarrier © J.C. Baltzer AG, Science Publishers 1993 Abstract A tandem Penning trap system, the ISOLTRAP, is now used at the on-line mass separator ISOLDE at CERN, Geneva, for accurate mass measurements of short-lived nuclei. The mass of the stored ions is measured by the determination of the cyclotron frequency $ ω_{c} $=qB/m in theB=6 T magnetic field of the trap. A new technique has been developed and implemented to allow reliable high-efficiency loading of the trap with radioactive heavy ions. Mass Measurement Accurate Mass Cyclotron Frequency Accurate Mass Measurement Mass Separator Enthalten in Hyperfine interactions Kluwer Academic Publishers, 1975 81(1993), 1-4 vom: März, Seite 135-142 (DE-627)129438685 (DE-600)194471-X (DE-576)014809028 0304-3843 nnns volume:81 year:1993 number:1-4 month:03 pages:135-142 https://doi.org/10.1007/BF00567257 lizenzpflichtig Volltext GBV_USEFLAG_A SYSFLAG_A GBV_OLC SSG-OLC-PHY GBV_ILN_20 GBV_ILN_22 GBV_ILN_40 GBV_ILN_70 GBV_ILN_2279 GBV_ILN_4012 GBV_ILN_4046 33.00 VZ AR 81 1993 1-4 03 135-142 |
language |
English |
source |
Enthalten in Hyperfine interactions 81(1993), 1-4 vom: März, Seite 135-142 volume:81 year:1993 number:1-4 month:03 pages:135-142 |
sourceStr |
Enthalten in Hyperfine interactions 81(1993), 1-4 vom: März, Seite 135-142 volume:81 year:1993 number:1-4 month:03 pages:135-142 |
format_phy_str_mv |
Article |
institution |
findex.gbv.de |
topic_facet |
Mass Measurement Accurate Mass Cyclotron Frequency Accurate Mass Measurement Mass Separator |
dewey-raw |
530 |
isfreeaccess_bool |
false |
container_title |
Hyperfine interactions |
authorswithroles_txt_mv |
Savard, G. @@aut@@ |
publishDateDaySort_date |
1993-03-01T00:00:00Z |
hierarchy_top_id |
129438685 |
dewey-sort |
3530 |
id |
OLC2076375856 |
language_de |
englisch |
fullrecord |
<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim"><record><leader>01000caa a22002652 4500</leader><controlfield tag="001">OLC2076375856</controlfield><controlfield tag="003">DE-627</controlfield><controlfield tag="005">20230503073735.0</controlfield><controlfield tag="007">tu</controlfield><controlfield tag="008">200820s1993 xx ||||| 00| ||eng c</controlfield><datafield tag="024" ind1="7" ind2=" "><subfield code="a">10.1007/BF00567257</subfield><subfield code="2">doi</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-627)OLC2076375856</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-He213)BF00567257-p</subfield></datafield><datafield tag="040" ind1=" " ind2=" "><subfield code="a">DE-627</subfield><subfield code="b">ger</subfield><subfield code="c">DE-627</subfield><subfield code="e">rakwb</subfield></datafield><datafield tag="041" ind1=" " ind2=" "><subfield code="a">eng</subfield></datafield><datafield tag="082" ind1="0" ind2="4"><subfield code="a">530</subfield><subfield code="q">VZ</subfield></datafield><datafield tag="084" ind1=" " ind2=" "><subfield code="a">33.00</subfield><subfield code="2">bkl</subfield></datafield><datafield tag="100" ind1="1" ind2=" "><subfield code="a">Savard, G.</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="245" ind1="1" ind2="0"><subfield code="a">RF-coupling and cooling techniques of stored heavy ions</subfield></datafield><datafield tag="264" ind1=" " ind2="1"><subfield code="c">1993</subfield></datafield><datafield tag="336" ind1=" " ind2=" "><subfield code="a">Text</subfield><subfield code="b">txt</subfield><subfield code="2">rdacontent</subfield></datafield><datafield tag="337" ind1=" " ind2=" "><subfield code="a">ohne Hilfsmittel zu benutzen</subfield><subfield code="b">n</subfield><subfield code="2">rdamedia</subfield></datafield><datafield tag="338" ind1=" " ind2=" "><subfield code="a">Band</subfield><subfield code="b">nc</subfield><subfield code="2">rdacarrier</subfield></datafield><datafield tag="500" ind1=" " ind2=" "><subfield code="a">© J.C. Baltzer AG, Science Publishers 1993</subfield></datafield><datafield tag="520" ind1=" " ind2=" "><subfield code="a">Abstract A tandem Penning trap system, the ISOLTRAP, is now used at the on-line mass separator ISOLDE at CERN, Geneva, for accurate mass measurements of short-lived nuclei. The mass of the stored ions is measured by the determination of the cyclotron frequency $ ω_{c} $=qB/m in theB=6 T magnetic field of the trap. A new technique has been developed and implemented to allow reliable high-efficiency loading of the trap with radioactive heavy ions.</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Mass Measurement</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Accurate Mass</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Cyclotron Frequency</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Accurate Mass Measurement</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Mass Separator</subfield></datafield><datafield tag="773" ind1="0" ind2="8"><subfield code="i">Enthalten in</subfield><subfield code="t">Hyperfine interactions</subfield><subfield code="d">Kluwer Academic Publishers, 1975</subfield><subfield code="g">81(1993), 1-4 vom: März, Seite 135-142</subfield><subfield code="w">(DE-627)129438685</subfield><subfield code="w">(DE-600)194471-X</subfield><subfield code="w">(DE-576)014809028</subfield><subfield code="x">0304-3843</subfield><subfield code="7">nnns</subfield></datafield><datafield tag="773" ind1="1" ind2="8"><subfield code="g">volume:81</subfield><subfield code="g">year:1993</subfield><subfield code="g">number:1-4</subfield><subfield code="g">month:03</subfield><subfield code="g">pages:135-142</subfield></datafield><datafield tag="856" ind1="4" ind2="1"><subfield code="u">https://doi.org/10.1007/BF00567257</subfield><subfield code="z">lizenzpflichtig</subfield><subfield code="3">Volltext</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_USEFLAG_A</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">SYSFLAG_A</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_OLC</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">SSG-OLC-PHY</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_20</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_22</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_40</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_70</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2279</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4012</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4046</subfield></datafield><datafield tag="936" ind1="b" ind2="k"><subfield code="a">33.00</subfield><subfield code="q">VZ</subfield></datafield><datafield tag="951" ind1=" " ind2=" "><subfield code="a">AR</subfield></datafield><datafield tag="952" ind1=" " ind2=" "><subfield code="d">81</subfield><subfield code="j">1993</subfield><subfield code="e">1-4</subfield><subfield code="c">03</subfield><subfield code="h">135-142</subfield></datafield></record></collection>
|
author |
Savard, G. |
spellingShingle |
Savard, G. ddc 530 bkl 33.00 misc Mass Measurement misc Accurate Mass misc Cyclotron Frequency misc Accurate Mass Measurement misc Mass Separator RF-coupling and cooling techniques of stored heavy ions |
authorStr |
Savard, G. |
ppnlink_with_tag_str_mv |
@@773@@(DE-627)129438685 |
format |
Article |
dewey-ones |
530 - Physics |
delete_txt_mv |
keep |
author_role |
aut |
collection |
OLC |
remote_str |
false |
illustrated |
Not Illustrated |
issn |
0304-3843 |
topic_title |
530 VZ 33.00 bkl RF-coupling and cooling techniques of stored heavy ions Mass Measurement Accurate Mass Cyclotron Frequency Accurate Mass Measurement Mass Separator |
topic |
ddc 530 bkl 33.00 misc Mass Measurement misc Accurate Mass misc Cyclotron Frequency misc Accurate Mass Measurement misc Mass Separator |
topic_unstemmed |
ddc 530 bkl 33.00 misc Mass Measurement misc Accurate Mass misc Cyclotron Frequency misc Accurate Mass Measurement misc Mass Separator |
topic_browse |
ddc 530 bkl 33.00 misc Mass Measurement misc Accurate Mass misc Cyclotron Frequency misc Accurate Mass Measurement misc Mass Separator |
format_facet |
Aufsätze Gedruckte Aufsätze |
format_main_str_mv |
Text Zeitschrift/Artikel |
carriertype_str_mv |
nc |
hierarchy_parent_title |
Hyperfine interactions |
hierarchy_parent_id |
129438685 |
dewey-tens |
530 - Physics |
hierarchy_top_title |
Hyperfine interactions |
isfreeaccess_txt |
false |
familylinks_str_mv |
(DE-627)129438685 (DE-600)194471-X (DE-576)014809028 |
title |
RF-coupling and cooling techniques of stored heavy ions |
ctrlnum |
(DE-627)OLC2076375856 (DE-He213)BF00567257-p |
title_full |
RF-coupling and cooling techniques of stored heavy ions |
author_sort |
Savard, G. |
journal |
Hyperfine interactions |
journalStr |
Hyperfine interactions |
lang_code |
eng |
isOA_bool |
false |
dewey-hundreds |
500 - Science |
recordtype |
marc |
publishDateSort |
1993 |
contenttype_str_mv |
txt |
container_start_page |
135 |
author_browse |
Savard, G. |
container_volume |
81 |
class |
530 VZ 33.00 bkl |
format_se |
Aufsätze |
author-letter |
Savard, G. |
doi_str_mv |
10.1007/BF00567257 |
dewey-full |
530 |
title_sort |
rf-coupling and cooling techniques of stored heavy ions |
title_auth |
RF-coupling and cooling techniques of stored heavy ions |
abstract |
Abstract A tandem Penning trap system, the ISOLTRAP, is now used at the on-line mass separator ISOLDE at CERN, Geneva, for accurate mass measurements of short-lived nuclei. The mass of the stored ions is measured by the determination of the cyclotron frequency $ ω_{c} $=qB/m in theB=6 T magnetic field of the trap. A new technique has been developed and implemented to allow reliable high-efficiency loading of the trap with radioactive heavy ions. © J.C. Baltzer AG, Science Publishers 1993 |
abstractGer |
Abstract A tandem Penning trap system, the ISOLTRAP, is now used at the on-line mass separator ISOLDE at CERN, Geneva, for accurate mass measurements of short-lived nuclei. The mass of the stored ions is measured by the determination of the cyclotron frequency $ ω_{c} $=qB/m in theB=6 T magnetic field of the trap. A new technique has been developed and implemented to allow reliable high-efficiency loading of the trap with radioactive heavy ions. © J.C. Baltzer AG, Science Publishers 1993 |
abstract_unstemmed |
Abstract A tandem Penning trap system, the ISOLTRAP, is now used at the on-line mass separator ISOLDE at CERN, Geneva, for accurate mass measurements of short-lived nuclei. The mass of the stored ions is measured by the determination of the cyclotron frequency $ ω_{c} $=qB/m in theB=6 T magnetic field of the trap. A new technique has been developed and implemented to allow reliable high-efficiency loading of the trap with radioactive heavy ions. © J.C. Baltzer AG, Science Publishers 1993 |
collection_details |
GBV_USEFLAG_A SYSFLAG_A GBV_OLC SSG-OLC-PHY GBV_ILN_20 GBV_ILN_22 GBV_ILN_40 GBV_ILN_70 GBV_ILN_2279 GBV_ILN_4012 GBV_ILN_4046 |
container_issue |
1-4 |
title_short |
RF-coupling and cooling techniques of stored heavy ions |
url |
https://doi.org/10.1007/BF00567257 |
remote_bool |
false |
ppnlink |
129438685 |
mediatype_str_mv |
n |
isOA_txt |
false |
hochschulschrift_bool |
false |
doi_str |
10.1007/BF00567257 |
up_date |
2024-07-04T03:13:12.180Z |
_version_ |
1803616562385518592 |
fullrecord_marcxml |
<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim"><record><leader>01000caa a22002652 4500</leader><controlfield tag="001">OLC2076375856</controlfield><controlfield tag="003">DE-627</controlfield><controlfield tag="005">20230503073735.0</controlfield><controlfield tag="007">tu</controlfield><controlfield tag="008">200820s1993 xx ||||| 00| ||eng c</controlfield><datafield tag="024" ind1="7" ind2=" "><subfield code="a">10.1007/BF00567257</subfield><subfield code="2">doi</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-627)OLC2076375856</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-He213)BF00567257-p</subfield></datafield><datafield tag="040" ind1=" " ind2=" "><subfield code="a">DE-627</subfield><subfield code="b">ger</subfield><subfield code="c">DE-627</subfield><subfield code="e">rakwb</subfield></datafield><datafield tag="041" ind1=" " ind2=" "><subfield code="a">eng</subfield></datafield><datafield tag="082" ind1="0" ind2="4"><subfield code="a">530</subfield><subfield code="q">VZ</subfield></datafield><datafield tag="084" ind1=" " ind2=" "><subfield code="a">33.00</subfield><subfield code="2">bkl</subfield></datafield><datafield tag="100" ind1="1" ind2=" "><subfield code="a">Savard, G.</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="245" ind1="1" ind2="0"><subfield code="a">RF-coupling and cooling techniques of stored heavy ions</subfield></datafield><datafield tag="264" ind1=" " ind2="1"><subfield code="c">1993</subfield></datafield><datafield tag="336" ind1=" " ind2=" "><subfield code="a">Text</subfield><subfield code="b">txt</subfield><subfield code="2">rdacontent</subfield></datafield><datafield tag="337" ind1=" " ind2=" "><subfield code="a">ohne Hilfsmittel zu benutzen</subfield><subfield code="b">n</subfield><subfield code="2">rdamedia</subfield></datafield><datafield tag="338" ind1=" " ind2=" "><subfield code="a">Band</subfield><subfield code="b">nc</subfield><subfield code="2">rdacarrier</subfield></datafield><datafield tag="500" ind1=" " ind2=" "><subfield code="a">© J.C. Baltzer AG, Science Publishers 1993</subfield></datafield><datafield tag="520" ind1=" " ind2=" "><subfield code="a">Abstract A tandem Penning trap system, the ISOLTRAP, is now used at the on-line mass separator ISOLDE at CERN, Geneva, for accurate mass measurements of short-lived nuclei. The mass of the stored ions is measured by the determination of the cyclotron frequency $ ω_{c} $=qB/m in theB=6 T magnetic field of the trap. A new technique has been developed and implemented to allow reliable high-efficiency loading of the trap with radioactive heavy ions.</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Mass Measurement</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Accurate Mass</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Cyclotron Frequency</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Accurate Mass Measurement</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Mass Separator</subfield></datafield><datafield tag="773" ind1="0" ind2="8"><subfield code="i">Enthalten in</subfield><subfield code="t">Hyperfine interactions</subfield><subfield code="d">Kluwer Academic Publishers, 1975</subfield><subfield code="g">81(1993), 1-4 vom: März, Seite 135-142</subfield><subfield code="w">(DE-627)129438685</subfield><subfield code="w">(DE-600)194471-X</subfield><subfield code="w">(DE-576)014809028</subfield><subfield code="x">0304-3843</subfield><subfield code="7">nnns</subfield></datafield><datafield tag="773" ind1="1" ind2="8"><subfield code="g">volume:81</subfield><subfield code="g">year:1993</subfield><subfield code="g">number:1-4</subfield><subfield code="g">month:03</subfield><subfield code="g">pages:135-142</subfield></datafield><datafield tag="856" ind1="4" ind2="1"><subfield code="u">https://doi.org/10.1007/BF00567257</subfield><subfield code="z">lizenzpflichtig</subfield><subfield code="3">Volltext</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_USEFLAG_A</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">SYSFLAG_A</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_OLC</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">SSG-OLC-PHY</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_20</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_22</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_40</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_70</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2279</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4012</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4046</subfield></datafield><datafield tag="936" ind1="b" ind2="k"><subfield code="a">33.00</subfield><subfield code="q">VZ</subfield></datafield><datafield tag="951" ind1=" " ind2=" "><subfield code="a">AR</subfield></datafield><datafield tag="952" ind1=" " ind2=" "><subfield code="d">81</subfield><subfield code="j">1993</subfield><subfield code="e">1-4</subfield><subfield code="c">03</subfield><subfield code="h">135-142</subfield></datafield></record></collection>
|
score |
7.4025326 |