Does computer-assisted surgery improve postoperative leg alignment and implant positioning following total knee arthroplasty? A meta-analysis of randomized controlled trials?
Purpose Computer-assisted surgery has been proposed as a technique to improve implant alignment during total knee arthroplasty (TKA). However, there is still a debate over the accuracy of placing the femoral and tibial components using computer-assisted systems in TKA. The aim of this study is to es...
Ausführliche Beschreibung
Autor*in: |
Cheng, Tao [verfasserIn] |
---|
Format: |
E-Artikel |
---|---|
Sprache: |
Englisch |
Erschienen: |
2011 |
---|
Schlagwörter: |
---|
Anmerkung: |
© Springer-Verlag 2011 |
---|
Übergeordnetes Werk: |
Enthalten in: Knee surgery, sports traumatology, arthroscopy - Berlin : Springer, 1993, 20(2011), 7 vom: 06. Juli, Seite 1307-1322 |
---|---|
Übergeordnetes Werk: |
volume:20 ; year:2011 ; number:7 ; day:06 ; month:07 ; pages:1307-1322 |
Links: |
---|
DOI / URN: |
10.1007/s00167-011-1588-8 |
---|
Katalog-ID: |
SPR001383965 |
---|
LEADER | 01000caa a22002652 4500 | ||
---|---|---|---|
001 | SPR001383965 | ||
003 | DE-627 | ||
005 | 20230519085234.0 | ||
007 | cr uuu---uuuuu | ||
008 | 201001s2011 xx |||||o 00| ||eng c | ||
024 | 7 | |a 10.1007/s00167-011-1588-8 |2 doi | |
035 | |a (DE-627)SPR001383965 | ||
035 | |a (SPR)s00167-011-1588-8-e | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
100 | 1 | |a Cheng, Tao |e verfasserin |4 aut | |
245 | 1 | 0 | |a Does computer-assisted surgery improve postoperative leg alignment and implant positioning following total knee arthroplasty? A meta-analysis of randomized controlled trials? |
264 | 1 | |c 2011 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a Computermedien |b c |2 rdamedia | ||
338 | |a Online-Ressource |b cr |2 rdacarrier | ||
500 | |a © Springer-Verlag 2011 | ||
520 | |a Purpose Computer-assisted surgery has been proposed as a technique to improve implant alignment during total knee arthroplasty (TKA). However, there is still a debate over the accuracy of placing the femoral and tibial components using computer-assisted systems in TKA. The aim of this study is to establish whether computer-assisted surgery leads to superior mechanical leg axis and implant positioning than conventional technique in patients with primary TKA. Methods Major electronic databases were systematically searched to identify relevant studies without language restriction. A meta-analysis of 41 randomized controlled trials (RCTs) or quasi-RCTs was performed in a random effects model. A subgroup analysis was conducted by type of navigation system to explore the clinical heterogeneity between these trials. The following radiographic parameters were used to compare computer-assisted surgery with conventional technique: (1) mechanical leg axis, (2) femoral component coronal alignment, (3) tibial component coronal alignment, (4) femoral component sagittal alignment, and (5) tibial component sagittal alignment. Results For the mechanical leg axis and coronal positioning of femoral and tibial components, there are statistically significant reductions in the number of patients with malalignment in the CAS group if the outlier cutoff value is ±3 or 2° in the coronal and sagittal planes, respectively. Subgroup analysis demonstrates that CT-free navigation systems provide better alignment than conventional techniques in the coronal and sagittal alignment of femoral components within ±3 and 2°. If the outlier cutoff value for the tibial sagittal alignment is ±2°, the outlier percentages are higher in the CT-free navigation group than in the conventional group. However, there was no significant difference in the tibial sagittal alignment at ±3°. Conclusion Computer-assisted surgery does improve mechanical leg axis and component orientation in TKAs. However, high-quality RCTs are necessary to determine whether surgeons could use computer-assisted techniques to achieve a targeted tibial slope in TKA. Level of evidence Therapeutic study (Systematic review of Level I/II studies), Level II. | ||
650 | 4 | |a Computer-assisted surgery |7 (dpeaa)DE-He213 | |
650 | 4 | |a Navigation |7 (dpeaa)DE-He213 | |
650 | 4 | |a Total knee replacement |7 (dpeaa)DE-He213 | |
650 | 4 | |a TKR |7 (dpeaa)DE-He213 | |
650 | 4 | |a Meta-analysis |7 (dpeaa)DE-He213 | |
650 | 4 | |a Randomized controlled trial |7 (dpeaa)DE-He213 | |
700 | 1 | |a Zhao, Song |4 aut | |
700 | 1 | |a Peng, Xiaochun |4 aut | |
700 | 1 | |a Zhang, Xianlong |4 aut | |
773 | 0 | 8 | |i Enthalten in |t Knee surgery, sports traumatology, arthroscopy |d Berlin : Springer, 1993 |g 20(2011), 7 vom: 06. Juli, Seite 1307-1322 |w (DE-627)268761787 |w (DE-600)1473170-8 |x 1433-7347 |7 nnns |
773 | 1 | 8 | |g volume:20 |g year:2011 |g number:7 |g day:06 |g month:07 |g pages:1307-1322 |
856 | 4 | 0 | |u https://dx.doi.org/10.1007/s00167-011-1588-8 |z lizenzpflichtig |3 Volltext |
912 | |a GBV_USEFLAG_A | ||
912 | |a SYSFLAG_A | ||
912 | |a GBV_SPRINGER | ||
912 | |a SSG-OLC-PHA | ||
912 | |a GBV_ILN_11 | ||
912 | |a GBV_ILN_20 | ||
912 | |a GBV_ILN_22 | ||
912 | |a GBV_ILN_23 | ||
912 | |a GBV_ILN_24 | ||
912 | |a GBV_ILN_31 | ||
912 | |a GBV_ILN_32 | ||
912 | |a GBV_ILN_39 | ||
912 | |a GBV_ILN_40 | ||
912 | |a GBV_ILN_60 | ||
912 | |a GBV_ILN_62 | ||
912 | |a GBV_ILN_63 | ||
912 | |a GBV_ILN_69 | ||
912 | |a GBV_ILN_70 | ||
912 | |a GBV_ILN_73 | ||
912 | |a GBV_ILN_74 | ||
912 | |a GBV_ILN_90 | ||
912 | |a GBV_ILN_95 | ||
912 | |a GBV_ILN_100 | ||
912 | |a GBV_ILN_101 | ||
912 | |a GBV_ILN_105 | ||
912 | |a GBV_ILN_110 | ||
912 | |a GBV_ILN_120 | ||
912 | |a GBV_ILN_138 | ||
912 | |a GBV_ILN_150 | ||
912 | |a GBV_ILN_151 | ||
912 | |a GBV_ILN_152 | ||
912 | |a GBV_ILN_161 | ||
912 | |a GBV_ILN_165 | ||
912 | |a GBV_ILN_170 | ||
912 | |a GBV_ILN_171 | ||
912 | |a GBV_ILN_187 | ||
912 | |a GBV_ILN_213 | ||
912 | |a GBV_ILN_224 | ||
912 | |a GBV_ILN_230 | ||
912 | |a GBV_ILN_250 | ||
912 | |a GBV_ILN_267 | ||
912 | |a GBV_ILN_281 | ||
912 | |a GBV_ILN_285 | ||
912 | |a GBV_ILN_293 | ||
912 | |a GBV_ILN_370 | ||
912 | |a GBV_ILN_602 | ||
912 | |a GBV_ILN_636 | ||
912 | |a GBV_ILN_702 | ||
912 | |a GBV_ILN_711 | ||
912 | |a GBV_ILN_2001 | ||
912 | |a GBV_ILN_2003 | ||
912 | |a GBV_ILN_2004 | ||
912 | |a GBV_ILN_2005 | ||
912 | |a GBV_ILN_2006 | ||
912 | |a GBV_ILN_2007 | ||
912 | |a GBV_ILN_2009 | ||
912 | |a GBV_ILN_2010 | ||
912 | |a GBV_ILN_2011 | ||
912 | |a GBV_ILN_2014 | ||
912 | |a GBV_ILN_2015 | ||
912 | |a GBV_ILN_2020 | ||
912 | |a GBV_ILN_2021 | ||
912 | |a GBV_ILN_2025 | ||
912 | |a GBV_ILN_2026 | ||
912 | |a GBV_ILN_2027 | ||
912 | |a GBV_ILN_2031 | ||
912 | |a GBV_ILN_2034 | ||
912 | |a GBV_ILN_2037 | ||
912 | |a GBV_ILN_2038 | ||
912 | |a GBV_ILN_2039 | ||
912 | |a GBV_ILN_2044 | ||
912 | |a GBV_ILN_2048 | ||
912 | |a GBV_ILN_2049 | ||
912 | |a GBV_ILN_2050 | ||
912 | |a GBV_ILN_2055 | ||
912 | |a GBV_ILN_2056 | ||
912 | |a GBV_ILN_2057 | ||
912 | |a GBV_ILN_2059 | ||
912 | |a GBV_ILN_2061 | ||
912 | |a GBV_ILN_2064 | ||
912 | |a GBV_ILN_2065 | ||
912 | |a GBV_ILN_2068 | ||
912 | |a GBV_ILN_2070 | ||
912 | |a GBV_ILN_2086 | ||
912 | |a GBV_ILN_2088 | ||
912 | |a GBV_ILN_2093 | ||
912 | |a GBV_ILN_2106 | ||
912 | |a GBV_ILN_2107 | ||
912 | |a GBV_ILN_2108 | ||
912 | |a GBV_ILN_2110 | ||
912 | |a GBV_ILN_2111 | ||
912 | |a GBV_ILN_2112 | ||
912 | |a GBV_ILN_2113 | ||
912 | |a GBV_ILN_2116 | ||
912 | |a GBV_ILN_2118 | ||
912 | |a GBV_ILN_2119 | ||
912 | |a GBV_ILN_2122 | ||
912 | |a GBV_ILN_2129 | ||
912 | |a GBV_ILN_2143 | ||
912 | |a GBV_ILN_2144 | ||
912 | |a GBV_ILN_2147 | ||
912 | |a GBV_ILN_2148 | ||
912 | |a GBV_ILN_2152 | ||
912 | |a GBV_ILN_2153 | ||
912 | |a GBV_ILN_2188 | ||
912 | |a GBV_ILN_2190 | ||
912 | |a GBV_ILN_2232 | ||
912 | |a GBV_ILN_2336 | ||
912 | |a GBV_ILN_2446 | ||
912 | |a GBV_ILN_2470 | ||
912 | |a GBV_ILN_2472 | ||
912 | |a GBV_ILN_2507 | ||
912 | |a GBV_ILN_2522 | ||
912 | |a GBV_ILN_2548 | ||
912 | |a GBV_ILN_4012 | ||
912 | |a GBV_ILN_4035 | ||
912 | |a GBV_ILN_4037 | ||
912 | |a GBV_ILN_4046 | ||
912 | |a GBV_ILN_4112 | ||
912 | |a GBV_ILN_4125 | ||
912 | |a GBV_ILN_4126 | ||
912 | |a GBV_ILN_4242 | ||
912 | |a GBV_ILN_4246 | ||
912 | |a GBV_ILN_4249 | ||
912 | |a GBV_ILN_4251 | ||
912 | |a GBV_ILN_4305 | ||
912 | |a GBV_ILN_4306 | ||
912 | |a GBV_ILN_4307 | ||
912 | |a GBV_ILN_4313 | ||
912 | |a GBV_ILN_4322 | ||
912 | |a GBV_ILN_4323 | ||
912 | |a GBV_ILN_4324 | ||
912 | |a GBV_ILN_4325 | ||
912 | |a GBV_ILN_4326 | ||
912 | |a GBV_ILN_4328 | ||
912 | |a GBV_ILN_4333 | ||
912 | |a GBV_ILN_4334 | ||
912 | |a GBV_ILN_4335 | ||
912 | |a GBV_ILN_4336 | ||
912 | |a GBV_ILN_4338 | ||
912 | |a GBV_ILN_4393 | ||
912 | |a GBV_ILN_4700 | ||
951 | |a AR | ||
952 | |d 20 |j 2011 |e 7 |b 06 |c 07 |h 1307-1322 |
author_variant |
t c tc s z sz x p xp x z xz |
---|---|
matchkey_str |
article:14337347:2011----::osoptrsitdugripoeotprtvlglgmnadmlnpstoigolwnttlnerholsy |
hierarchy_sort_str |
2011 |
publishDate |
2011 |
allfields |
10.1007/s00167-011-1588-8 doi (DE-627)SPR001383965 (SPR)s00167-011-1588-8-e DE-627 ger DE-627 rakwb eng Cheng, Tao verfasserin aut Does computer-assisted surgery improve postoperative leg alignment and implant positioning following total knee arthroplasty? A meta-analysis of randomized controlled trials? 2011 Text txt rdacontent Computermedien c rdamedia Online-Ressource cr rdacarrier © Springer-Verlag 2011 Purpose Computer-assisted surgery has been proposed as a technique to improve implant alignment during total knee arthroplasty (TKA). However, there is still a debate over the accuracy of placing the femoral and tibial components using computer-assisted systems in TKA. The aim of this study is to establish whether computer-assisted surgery leads to superior mechanical leg axis and implant positioning than conventional technique in patients with primary TKA. Methods Major electronic databases were systematically searched to identify relevant studies without language restriction. A meta-analysis of 41 randomized controlled trials (RCTs) or quasi-RCTs was performed in a random effects model. A subgroup analysis was conducted by type of navigation system to explore the clinical heterogeneity between these trials. The following radiographic parameters were used to compare computer-assisted surgery with conventional technique: (1) mechanical leg axis, (2) femoral component coronal alignment, (3) tibial component coronal alignment, (4) femoral component sagittal alignment, and (5) tibial component sagittal alignment. Results For the mechanical leg axis and coronal positioning of femoral and tibial components, there are statistically significant reductions in the number of patients with malalignment in the CAS group if the outlier cutoff value is ±3 or 2° in the coronal and sagittal planes, respectively. Subgroup analysis demonstrates that CT-free navigation systems provide better alignment than conventional techniques in the coronal and sagittal alignment of femoral components within ±3 and 2°. If the outlier cutoff value for the tibial sagittal alignment is ±2°, the outlier percentages are higher in the CT-free navigation group than in the conventional group. However, there was no significant difference in the tibial sagittal alignment at ±3°. Conclusion Computer-assisted surgery does improve mechanical leg axis and component orientation in TKAs. However, high-quality RCTs are necessary to determine whether surgeons could use computer-assisted techniques to achieve a targeted tibial slope in TKA. Level of evidence Therapeutic study (Systematic review of Level I/II studies), Level II. Computer-assisted surgery (dpeaa)DE-He213 Navigation (dpeaa)DE-He213 Total knee replacement (dpeaa)DE-He213 TKR (dpeaa)DE-He213 Meta-analysis (dpeaa)DE-He213 Randomized controlled trial (dpeaa)DE-He213 Zhao, Song aut Peng, Xiaochun aut Zhang, Xianlong aut Enthalten in Knee surgery, sports traumatology, arthroscopy Berlin : Springer, 1993 20(2011), 7 vom: 06. Juli, Seite 1307-1322 (DE-627)268761787 (DE-600)1473170-8 1433-7347 nnns volume:20 year:2011 number:7 day:06 month:07 pages:1307-1322 https://dx.doi.org/10.1007/s00167-011-1588-8 lizenzpflichtig Volltext GBV_USEFLAG_A SYSFLAG_A GBV_SPRINGER SSG-OLC-PHA GBV_ILN_11 GBV_ILN_20 GBV_ILN_22 GBV_ILN_23 GBV_ILN_24 GBV_ILN_31 GBV_ILN_32 GBV_ILN_39 GBV_ILN_40 GBV_ILN_60 GBV_ILN_62 GBV_ILN_63 GBV_ILN_69 GBV_ILN_70 GBV_ILN_73 GBV_ILN_74 GBV_ILN_90 GBV_ILN_95 GBV_ILN_100 GBV_ILN_101 GBV_ILN_105 GBV_ILN_110 GBV_ILN_120 GBV_ILN_138 GBV_ILN_150 GBV_ILN_151 GBV_ILN_152 GBV_ILN_161 GBV_ILN_165 GBV_ILN_170 GBV_ILN_171 GBV_ILN_187 GBV_ILN_213 GBV_ILN_224 GBV_ILN_230 GBV_ILN_250 GBV_ILN_267 GBV_ILN_281 GBV_ILN_285 GBV_ILN_293 GBV_ILN_370 GBV_ILN_602 GBV_ILN_636 GBV_ILN_702 GBV_ILN_711 GBV_ILN_2001 GBV_ILN_2003 GBV_ILN_2004 GBV_ILN_2005 GBV_ILN_2006 GBV_ILN_2007 GBV_ILN_2009 GBV_ILN_2010 GBV_ILN_2011 GBV_ILN_2014 GBV_ILN_2015 GBV_ILN_2020 GBV_ILN_2021 GBV_ILN_2025 GBV_ILN_2026 GBV_ILN_2027 GBV_ILN_2031 GBV_ILN_2034 GBV_ILN_2037 GBV_ILN_2038 GBV_ILN_2039 GBV_ILN_2044 GBV_ILN_2048 GBV_ILN_2049 GBV_ILN_2050 GBV_ILN_2055 GBV_ILN_2056 GBV_ILN_2057 GBV_ILN_2059 GBV_ILN_2061 GBV_ILN_2064 GBV_ILN_2065 GBV_ILN_2068 GBV_ILN_2070 GBV_ILN_2086 GBV_ILN_2088 GBV_ILN_2093 GBV_ILN_2106 GBV_ILN_2107 GBV_ILN_2108 GBV_ILN_2110 GBV_ILN_2111 GBV_ILN_2112 GBV_ILN_2113 GBV_ILN_2116 GBV_ILN_2118 GBV_ILN_2119 GBV_ILN_2122 GBV_ILN_2129 GBV_ILN_2143 GBV_ILN_2144 GBV_ILN_2147 GBV_ILN_2148 GBV_ILN_2152 GBV_ILN_2153 GBV_ILN_2188 GBV_ILN_2190 GBV_ILN_2232 GBV_ILN_2336 GBV_ILN_2446 GBV_ILN_2470 GBV_ILN_2472 GBV_ILN_2507 GBV_ILN_2522 GBV_ILN_2548 GBV_ILN_4012 GBV_ILN_4035 GBV_ILN_4037 GBV_ILN_4046 GBV_ILN_4112 GBV_ILN_4125 GBV_ILN_4126 GBV_ILN_4242 GBV_ILN_4246 GBV_ILN_4249 GBV_ILN_4251 GBV_ILN_4305 GBV_ILN_4306 GBV_ILN_4307 GBV_ILN_4313 GBV_ILN_4322 GBV_ILN_4323 GBV_ILN_4324 GBV_ILN_4325 GBV_ILN_4326 GBV_ILN_4328 GBV_ILN_4333 GBV_ILN_4334 GBV_ILN_4335 GBV_ILN_4336 GBV_ILN_4338 GBV_ILN_4393 GBV_ILN_4700 AR 20 2011 7 06 07 1307-1322 |
spelling |
10.1007/s00167-011-1588-8 doi (DE-627)SPR001383965 (SPR)s00167-011-1588-8-e DE-627 ger DE-627 rakwb eng Cheng, Tao verfasserin aut Does computer-assisted surgery improve postoperative leg alignment and implant positioning following total knee arthroplasty? A meta-analysis of randomized controlled trials? 2011 Text txt rdacontent Computermedien c rdamedia Online-Ressource cr rdacarrier © Springer-Verlag 2011 Purpose Computer-assisted surgery has been proposed as a technique to improve implant alignment during total knee arthroplasty (TKA). However, there is still a debate over the accuracy of placing the femoral and tibial components using computer-assisted systems in TKA. The aim of this study is to establish whether computer-assisted surgery leads to superior mechanical leg axis and implant positioning than conventional technique in patients with primary TKA. Methods Major electronic databases were systematically searched to identify relevant studies without language restriction. A meta-analysis of 41 randomized controlled trials (RCTs) or quasi-RCTs was performed in a random effects model. A subgroup analysis was conducted by type of navigation system to explore the clinical heterogeneity between these trials. The following radiographic parameters were used to compare computer-assisted surgery with conventional technique: (1) mechanical leg axis, (2) femoral component coronal alignment, (3) tibial component coronal alignment, (4) femoral component sagittal alignment, and (5) tibial component sagittal alignment. Results For the mechanical leg axis and coronal positioning of femoral and tibial components, there are statistically significant reductions in the number of patients with malalignment in the CAS group if the outlier cutoff value is ±3 or 2° in the coronal and sagittal planes, respectively. Subgroup analysis demonstrates that CT-free navigation systems provide better alignment than conventional techniques in the coronal and sagittal alignment of femoral components within ±3 and 2°. If the outlier cutoff value for the tibial sagittal alignment is ±2°, the outlier percentages are higher in the CT-free navigation group than in the conventional group. However, there was no significant difference in the tibial sagittal alignment at ±3°. Conclusion Computer-assisted surgery does improve mechanical leg axis and component orientation in TKAs. However, high-quality RCTs are necessary to determine whether surgeons could use computer-assisted techniques to achieve a targeted tibial slope in TKA. Level of evidence Therapeutic study (Systematic review of Level I/II studies), Level II. Computer-assisted surgery (dpeaa)DE-He213 Navigation (dpeaa)DE-He213 Total knee replacement (dpeaa)DE-He213 TKR (dpeaa)DE-He213 Meta-analysis (dpeaa)DE-He213 Randomized controlled trial (dpeaa)DE-He213 Zhao, Song aut Peng, Xiaochun aut Zhang, Xianlong aut Enthalten in Knee surgery, sports traumatology, arthroscopy Berlin : Springer, 1993 20(2011), 7 vom: 06. Juli, Seite 1307-1322 (DE-627)268761787 (DE-600)1473170-8 1433-7347 nnns volume:20 year:2011 number:7 day:06 month:07 pages:1307-1322 https://dx.doi.org/10.1007/s00167-011-1588-8 lizenzpflichtig Volltext GBV_USEFLAG_A SYSFLAG_A GBV_SPRINGER SSG-OLC-PHA GBV_ILN_11 GBV_ILN_20 GBV_ILN_22 GBV_ILN_23 GBV_ILN_24 GBV_ILN_31 GBV_ILN_32 GBV_ILN_39 GBV_ILN_40 GBV_ILN_60 GBV_ILN_62 GBV_ILN_63 GBV_ILN_69 GBV_ILN_70 GBV_ILN_73 GBV_ILN_74 GBV_ILN_90 GBV_ILN_95 GBV_ILN_100 GBV_ILN_101 GBV_ILN_105 GBV_ILN_110 GBV_ILN_120 GBV_ILN_138 GBV_ILN_150 GBV_ILN_151 GBV_ILN_152 GBV_ILN_161 GBV_ILN_165 GBV_ILN_170 GBV_ILN_171 GBV_ILN_187 GBV_ILN_213 GBV_ILN_224 GBV_ILN_230 GBV_ILN_250 GBV_ILN_267 GBV_ILN_281 GBV_ILN_285 GBV_ILN_293 GBV_ILN_370 GBV_ILN_602 GBV_ILN_636 GBV_ILN_702 GBV_ILN_711 GBV_ILN_2001 GBV_ILN_2003 GBV_ILN_2004 GBV_ILN_2005 GBV_ILN_2006 GBV_ILN_2007 GBV_ILN_2009 GBV_ILN_2010 GBV_ILN_2011 GBV_ILN_2014 GBV_ILN_2015 GBV_ILN_2020 GBV_ILN_2021 GBV_ILN_2025 GBV_ILN_2026 GBV_ILN_2027 GBV_ILN_2031 GBV_ILN_2034 GBV_ILN_2037 GBV_ILN_2038 GBV_ILN_2039 GBV_ILN_2044 GBV_ILN_2048 GBV_ILN_2049 GBV_ILN_2050 GBV_ILN_2055 GBV_ILN_2056 GBV_ILN_2057 GBV_ILN_2059 GBV_ILN_2061 GBV_ILN_2064 GBV_ILN_2065 GBV_ILN_2068 GBV_ILN_2070 GBV_ILN_2086 GBV_ILN_2088 GBV_ILN_2093 GBV_ILN_2106 GBV_ILN_2107 GBV_ILN_2108 GBV_ILN_2110 GBV_ILN_2111 GBV_ILN_2112 GBV_ILN_2113 GBV_ILN_2116 GBV_ILN_2118 GBV_ILN_2119 GBV_ILN_2122 GBV_ILN_2129 GBV_ILN_2143 GBV_ILN_2144 GBV_ILN_2147 GBV_ILN_2148 GBV_ILN_2152 GBV_ILN_2153 GBV_ILN_2188 GBV_ILN_2190 GBV_ILN_2232 GBV_ILN_2336 GBV_ILN_2446 GBV_ILN_2470 GBV_ILN_2472 GBV_ILN_2507 GBV_ILN_2522 GBV_ILN_2548 GBV_ILN_4012 GBV_ILN_4035 GBV_ILN_4037 GBV_ILN_4046 GBV_ILN_4112 GBV_ILN_4125 GBV_ILN_4126 GBV_ILN_4242 GBV_ILN_4246 GBV_ILN_4249 GBV_ILN_4251 GBV_ILN_4305 GBV_ILN_4306 GBV_ILN_4307 GBV_ILN_4313 GBV_ILN_4322 GBV_ILN_4323 GBV_ILN_4324 GBV_ILN_4325 GBV_ILN_4326 GBV_ILN_4328 GBV_ILN_4333 GBV_ILN_4334 GBV_ILN_4335 GBV_ILN_4336 GBV_ILN_4338 GBV_ILN_4393 GBV_ILN_4700 AR 20 2011 7 06 07 1307-1322 |
allfields_unstemmed |
10.1007/s00167-011-1588-8 doi (DE-627)SPR001383965 (SPR)s00167-011-1588-8-e DE-627 ger DE-627 rakwb eng Cheng, Tao verfasserin aut Does computer-assisted surgery improve postoperative leg alignment and implant positioning following total knee arthroplasty? A meta-analysis of randomized controlled trials? 2011 Text txt rdacontent Computermedien c rdamedia Online-Ressource cr rdacarrier © Springer-Verlag 2011 Purpose Computer-assisted surgery has been proposed as a technique to improve implant alignment during total knee arthroplasty (TKA). However, there is still a debate over the accuracy of placing the femoral and tibial components using computer-assisted systems in TKA. The aim of this study is to establish whether computer-assisted surgery leads to superior mechanical leg axis and implant positioning than conventional technique in patients with primary TKA. Methods Major electronic databases were systematically searched to identify relevant studies without language restriction. A meta-analysis of 41 randomized controlled trials (RCTs) or quasi-RCTs was performed in a random effects model. A subgroup analysis was conducted by type of navigation system to explore the clinical heterogeneity between these trials. The following radiographic parameters were used to compare computer-assisted surgery with conventional technique: (1) mechanical leg axis, (2) femoral component coronal alignment, (3) tibial component coronal alignment, (4) femoral component sagittal alignment, and (5) tibial component sagittal alignment. Results For the mechanical leg axis and coronal positioning of femoral and tibial components, there are statistically significant reductions in the number of patients with malalignment in the CAS group if the outlier cutoff value is ±3 or 2° in the coronal and sagittal planes, respectively. Subgroup analysis demonstrates that CT-free navigation systems provide better alignment than conventional techniques in the coronal and sagittal alignment of femoral components within ±3 and 2°. If the outlier cutoff value for the tibial sagittal alignment is ±2°, the outlier percentages are higher in the CT-free navigation group than in the conventional group. However, there was no significant difference in the tibial sagittal alignment at ±3°. Conclusion Computer-assisted surgery does improve mechanical leg axis and component orientation in TKAs. However, high-quality RCTs are necessary to determine whether surgeons could use computer-assisted techniques to achieve a targeted tibial slope in TKA. Level of evidence Therapeutic study (Systematic review of Level I/II studies), Level II. Computer-assisted surgery (dpeaa)DE-He213 Navigation (dpeaa)DE-He213 Total knee replacement (dpeaa)DE-He213 TKR (dpeaa)DE-He213 Meta-analysis (dpeaa)DE-He213 Randomized controlled trial (dpeaa)DE-He213 Zhao, Song aut Peng, Xiaochun aut Zhang, Xianlong aut Enthalten in Knee surgery, sports traumatology, arthroscopy Berlin : Springer, 1993 20(2011), 7 vom: 06. Juli, Seite 1307-1322 (DE-627)268761787 (DE-600)1473170-8 1433-7347 nnns volume:20 year:2011 number:7 day:06 month:07 pages:1307-1322 https://dx.doi.org/10.1007/s00167-011-1588-8 lizenzpflichtig Volltext GBV_USEFLAG_A SYSFLAG_A GBV_SPRINGER SSG-OLC-PHA GBV_ILN_11 GBV_ILN_20 GBV_ILN_22 GBV_ILN_23 GBV_ILN_24 GBV_ILN_31 GBV_ILN_32 GBV_ILN_39 GBV_ILN_40 GBV_ILN_60 GBV_ILN_62 GBV_ILN_63 GBV_ILN_69 GBV_ILN_70 GBV_ILN_73 GBV_ILN_74 GBV_ILN_90 GBV_ILN_95 GBV_ILN_100 GBV_ILN_101 GBV_ILN_105 GBV_ILN_110 GBV_ILN_120 GBV_ILN_138 GBV_ILN_150 GBV_ILN_151 GBV_ILN_152 GBV_ILN_161 GBV_ILN_165 GBV_ILN_170 GBV_ILN_171 GBV_ILN_187 GBV_ILN_213 GBV_ILN_224 GBV_ILN_230 GBV_ILN_250 GBV_ILN_267 GBV_ILN_281 GBV_ILN_285 GBV_ILN_293 GBV_ILN_370 GBV_ILN_602 GBV_ILN_636 GBV_ILN_702 GBV_ILN_711 GBV_ILN_2001 GBV_ILN_2003 GBV_ILN_2004 GBV_ILN_2005 GBV_ILN_2006 GBV_ILN_2007 GBV_ILN_2009 GBV_ILN_2010 GBV_ILN_2011 GBV_ILN_2014 GBV_ILN_2015 GBV_ILN_2020 GBV_ILN_2021 GBV_ILN_2025 GBV_ILN_2026 GBV_ILN_2027 GBV_ILN_2031 GBV_ILN_2034 GBV_ILN_2037 GBV_ILN_2038 GBV_ILN_2039 GBV_ILN_2044 GBV_ILN_2048 GBV_ILN_2049 GBV_ILN_2050 GBV_ILN_2055 GBV_ILN_2056 GBV_ILN_2057 GBV_ILN_2059 GBV_ILN_2061 GBV_ILN_2064 GBV_ILN_2065 GBV_ILN_2068 GBV_ILN_2070 GBV_ILN_2086 GBV_ILN_2088 GBV_ILN_2093 GBV_ILN_2106 GBV_ILN_2107 GBV_ILN_2108 GBV_ILN_2110 GBV_ILN_2111 GBV_ILN_2112 GBV_ILN_2113 GBV_ILN_2116 GBV_ILN_2118 GBV_ILN_2119 GBV_ILN_2122 GBV_ILN_2129 GBV_ILN_2143 GBV_ILN_2144 GBV_ILN_2147 GBV_ILN_2148 GBV_ILN_2152 GBV_ILN_2153 GBV_ILN_2188 GBV_ILN_2190 GBV_ILN_2232 GBV_ILN_2336 GBV_ILN_2446 GBV_ILN_2470 GBV_ILN_2472 GBV_ILN_2507 GBV_ILN_2522 GBV_ILN_2548 GBV_ILN_4012 GBV_ILN_4035 GBV_ILN_4037 GBV_ILN_4046 GBV_ILN_4112 GBV_ILN_4125 GBV_ILN_4126 GBV_ILN_4242 GBV_ILN_4246 GBV_ILN_4249 GBV_ILN_4251 GBV_ILN_4305 GBV_ILN_4306 GBV_ILN_4307 GBV_ILN_4313 GBV_ILN_4322 GBV_ILN_4323 GBV_ILN_4324 GBV_ILN_4325 GBV_ILN_4326 GBV_ILN_4328 GBV_ILN_4333 GBV_ILN_4334 GBV_ILN_4335 GBV_ILN_4336 GBV_ILN_4338 GBV_ILN_4393 GBV_ILN_4700 AR 20 2011 7 06 07 1307-1322 |
allfieldsGer |
10.1007/s00167-011-1588-8 doi (DE-627)SPR001383965 (SPR)s00167-011-1588-8-e DE-627 ger DE-627 rakwb eng Cheng, Tao verfasserin aut Does computer-assisted surgery improve postoperative leg alignment and implant positioning following total knee arthroplasty? A meta-analysis of randomized controlled trials? 2011 Text txt rdacontent Computermedien c rdamedia Online-Ressource cr rdacarrier © Springer-Verlag 2011 Purpose Computer-assisted surgery has been proposed as a technique to improve implant alignment during total knee arthroplasty (TKA). However, there is still a debate over the accuracy of placing the femoral and tibial components using computer-assisted systems in TKA. The aim of this study is to establish whether computer-assisted surgery leads to superior mechanical leg axis and implant positioning than conventional technique in patients with primary TKA. Methods Major electronic databases were systematically searched to identify relevant studies without language restriction. A meta-analysis of 41 randomized controlled trials (RCTs) or quasi-RCTs was performed in a random effects model. A subgroup analysis was conducted by type of navigation system to explore the clinical heterogeneity between these trials. The following radiographic parameters were used to compare computer-assisted surgery with conventional technique: (1) mechanical leg axis, (2) femoral component coronal alignment, (3) tibial component coronal alignment, (4) femoral component sagittal alignment, and (5) tibial component sagittal alignment. Results For the mechanical leg axis and coronal positioning of femoral and tibial components, there are statistically significant reductions in the number of patients with malalignment in the CAS group if the outlier cutoff value is ±3 or 2° in the coronal and sagittal planes, respectively. Subgroup analysis demonstrates that CT-free navigation systems provide better alignment than conventional techniques in the coronal and sagittal alignment of femoral components within ±3 and 2°. If the outlier cutoff value for the tibial sagittal alignment is ±2°, the outlier percentages are higher in the CT-free navigation group than in the conventional group. However, there was no significant difference in the tibial sagittal alignment at ±3°. Conclusion Computer-assisted surgery does improve mechanical leg axis and component orientation in TKAs. However, high-quality RCTs are necessary to determine whether surgeons could use computer-assisted techniques to achieve a targeted tibial slope in TKA. Level of evidence Therapeutic study (Systematic review of Level I/II studies), Level II. Computer-assisted surgery (dpeaa)DE-He213 Navigation (dpeaa)DE-He213 Total knee replacement (dpeaa)DE-He213 TKR (dpeaa)DE-He213 Meta-analysis (dpeaa)DE-He213 Randomized controlled trial (dpeaa)DE-He213 Zhao, Song aut Peng, Xiaochun aut Zhang, Xianlong aut Enthalten in Knee surgery, sports traumatology, arthroscopy Berlin : Springer, 1993 20(2011), 7 vom: 06. Juli, Seite 1307-1322 (DE-627)268761787 (DE-600)1473170-8 1433-7347 nnns volume:20 year:2011 number:7 day:06 month:07 pages:1307-1322 https://dx.doi.org/10.1007/s00167-011-1588-8 lizenzpflichtig Volltext GBV_USEFLAG_A SYSFLAG_A GBV_SPRINGER SSG-OLC-PHA GBV_ILN_11 GBV_ILN_20 GBV_ILN_22 GBV_ILN_23 GBV_ILN_24 GBV_ILN_31 GBV_ILN_32 GBV_ILN_39 GBV_ILN_40 GBV_ILN_60 GBV_ILN_62 GBV_ILN_63 GBV_ILN_69 GBV_ILN_70 GBV_ILN_73 GBV_ILN_74 GBV_ILN_90 GBV_ILN_95 GBV_ILN_100 GBV_ILN_101 GBV_ILN_105 GBV_ILN_110 GBV_ILN_120 GBV_ILN_138 GBV_ILN_150 GBV_ILN_151 GBV_ILN_152 GBV_ILN_161 GBV_ILN_165 GBV_ILN_170 GBV_ILN_171 GBV_ILN_187 GBV_ILN_213 GBV_ILN_224 GBV_ILN_230 GBV_ILN_250 GBV_ILN_267 GBV_ILN_281 GBV_ILN_285 GBV_ILN_293 GBV_ILN_370 GBV_ILN_602 GBV_ILN_636 GBV_ILN_702 GBV_ILN_711 GBV_ILN_2001 GBV_ILN_2003 GBV_ILN_2004 GBV_ILN_2005 GBV_ILN_2006 GBV_ILN_2007 GBV_ILN_2009 GBV_ILN_2010 GBV_ILN_2011 GBV_ILN_2014 GBV_ILN_2015 GBV_ILN_2020 GBV_ILN_2021 GBV_ILN_2025 GBV_ILN_2026 GBV_ILN_2027 GBV_ILN_2031 GBV_ILN_2034 GBV_ILN_2037 GBV_ILN_2038 GBV_ILN_2039 GBV_ILN_2044 GBV_ILN_2048 GBV_ILN_2049 GBV_ILN_2050 GBV_ILN_2055 GBV_ILN_2056 GBV_ILN_2057 GBV_ILN_2059 GBV_ILN_2061 GBV_ILN_2064 GBV_ILN_2065 GBV_ILN_2068 GBV_ILN_2070 GBV_ILN_2086 GBV_ILN_2088 GBV_ILN_2093 GBV_ILN_2106 GBV_ILN_2107 GBV_ILN_2108 GBV_ILN_2110 GBV_ILN_2111 GBV_ILN_2112 GBV_ILN_2113 GBV_ILN_2116 GBV_ILN_2118 GBV_ILN_2119 GBV_ILN_2122 GBV_ILN_2129 GBV_ILN_2143 GBV_ILN_2144 GBV_ILN_2147 GBV_ILN_2148 GBV_ILN_2152 GBV_ILN_2153 GBV_ILN_2188 GBV_ILN_2190 GBV_ILN_2232 GBV_ILN_2336 GBV_ILN_2446 GBV_ILN_2470 GBV_ILN_2472 GBV_ILN_2507 GBV_ILN_2522 GBV_ILN_2548 GBV_ILN_4012 GBV_ILN_4035 GBV_ILN_4037 GBV_ILN_4046 GBV_ILN_4112 GBV_ILN_4125 GBV_ILN_4126 GBV_ILN_4242 GBV_ILN_4246 GBV_ILN_4249 GBV_ILN_4251 GBV_ILN_4305 GBV_ILN_4306 GBV_ILN_4307 GBV_ILN_4313 GBV_ILN_4322 GBV_ILN_4323 GBV_ILN_4324 GBV_ILN_4325 GBV_ILN_4326 GBV_ILN_4328 GBV_ILN_4333 GBV_ILN_4334 GBV_ILN_4335 GBV_ILN_4336 GBV_ILN_4338 GBV_ILN_4393 GBV_ILN_4700 AR 20 2011 7 06 07 1307-1322 |
allfieldsSound |
10.1007/s00167-011-1588-8 doi (DE-627)SPR001383965 (SPR)s00167-011-1588-8-e DE-627 ger DE-627 rakwb eng Cheng, Tao verfasserin aut Does computer-assisted surgery improve postoperative leg alignment and implant positioning following total knee arthroplasty? A meta-analysis of randomized controlled trials? 2011 Text txt rdacontent Computermedien c rdamedia Online-Ressource cr rdacarrier © Springer-Verlag 2011 Purpose Computer-assisted surgery has been proposed as a technique to improve implant alignment during total knee arthroplasty (TKA). However, there is still a debate over the accuracy of placing the femoral and tibial components using computer-assisted systems in TKA. The aim of this study is to establish whether computer-assisted surgery leads to superior mechanical leg axis and implant positioning than conventional technique in patients with primary TKA. Methods Major electronic databases were systematically searched to identify relevant studies without language restriction. A meta-analysis of 41 randomized controlled trials (RCTs) or quasi-RCTs was performed in a random effects model. A subgroup analysis was conducted by type of navigation system to explore the clinical heterogeneity between these trials. The following radiographic parameters were used to compare computer-assisted surgery with conventional technique: (1) mechanical leg axis, (2) femoral component coronal alignment, (3) tibial component coronal alignment, (4) femoral component sagittal alignment, and (5) tibial component sagittal alignment. Results For the mechanical leg axis and coronal positioning of femoral and tibial components, there are statistically significant reductions in the number of patients with malalignment in the CAS group if the outlier cutoff value is ±3 or 2° in the coronal and sagittal planes, respectively. Subgroup analysis demonstrates that CT-free navigation systems provide better alignment than conventional techniques in the coronal and sagittal alignment of femoral components within ±3 and 2°. If the outlier cutoff value for the tibial sagittal alignment is ±2°, the outlier percentages are higher in the CT-free navigation group than in the conventional group. However, there was no significant difference in the tibial sagittal alignment at ±3°. Conclusion Computer-assisted surgery does improve mechanical leg axis and component orientation in TKAs. However, high-quality RCTs are necessary to determine whether surgeons could use computer-assisted techniques to achieve a targeted tibial slope in TKA. Level of evidence Therapeutic study (Systematic review of Level I/II studies), Level II. Computer-assisted surgery (dpeaa)DE-He213 Navigation (dpeaa)DE-He213 Total knee replacement (dpeaa)DE-He213 TKR (dpeaa)DE-He213 Meta-analysis (dpeaa)DE-He213 Randomized controlled trial (dpeaa)DE-He213 Zhao, Song aut Peng, Xiaochun aut Zhang, Xianlong aut Enthalten in Knee surgery, sports traumatology, arthroscopy Berlin : Springer, 1993 20(2011), 7 vom: 06. Juli, Seite 1307-1322 (DE-627)268761787 (DE-600)1473170-8 1433-7347 nnns volume:20 year:2011 number:7 day:06 month:07 pages:1307-1322 https://dx.doi.org/10.1007/s00167-011-1588-8 lizenzpflichtig Volltext GBV_USEFLAG_A SYSFLAG_A GBV_SPRINGER SSG-OLC-PHA GBV_ILN_11 GBV_ILN_20 GBV_ILN_22 GBV_ILN_23 GBV_ILN_24 GBV_ILN_31 GBV_ILN_32 GBV_ILN_39 GBV_ILN_40 GBV_ILN_60 GBV_ILN_62 GBV_ILN_63 GBV_ILN_69 GBV_ILN_70 GBV_ILN_73 GBV_ILN_74 GBV_ILN_90 GBV_ILN_95 GBV_ILN_100 GBV_ILN_101 GBV_ILN_105 GBV_ILN_110 GBV_ILN_120 GBV_ILN_138 GBV_ILN_150 GBV_ILN_151 GBV_ILN_152 GBV_ILN_161 GBV_ILN_165 GBV_ILN_170 GBV_ILN_171 GBV_ILN_187 GBV_ILN_213 GBV_ILN_224 GBV_ILN_230 GBV_ILN_250 GBV_ILN_267 GBV_ILN_281 GBV_ILN_285 GBV_ILN_293 GBV_ILN_370 GBV_ILN_602 GBV_ILN_636 GBV_ILN_702 GBV_ILN_711 GBV_ILN_2001 GBV_ILN_2003 GBV_ILN_2004 GBV_ILN_2005 GBV_ILN_2006 GBV_ILN_2007 GBV_ILN_2009 GBV_ILN_2010 GBV_ILN_2011 GBV_ILN_2014 GBV_ILN_2015 GBV_ILN_2020 GBV_ILN_2021 GBV_ILN_2025 GBV_ILN_2026 GBV_ILN_2027 GBV_ILN_2031 GBV_ILN_2034 GBV_ILN_2037 GBV_ILN_2038 GBV_ILN_2039 GBV_ILN_2044 GBV_ILN_2048 GBV_ILN_2049 GBV_ILN_2050 GBV_ILN_2055 GBV_ILN_2056 GBV_ILN_2057 GBV_ILN_2059 GBV_ILN_2061 GBV_ILN_2064 GBV_ILN_2065 GBV_ILN_2068 GBV_ILN_2070 GBV_ILN_2086 GBV_ILN_2088 GBV_ILN_2093 GBV_ILN_2106 GBV_ILN_2107 GBV_ILN_2108 GBV_ILN_2110 GBV_ILN_2111 GBV_ILN_2112 GBV_ILN_2113 GBV_ILN_2116 GBV_ILN_2118 GBV_ILN_2119 GBV_ILN_2122 GBV_ILN_2129 GBV_ILN_2143 GBV_ILN_2144 GBV_ILN_2147 GBV_ILN_2148 GBV_ILN_2152 GBV_ILN_2153 GBV_ILN_2188 GBV_ILN_2190 GBV_ILN_2232 GBV_ILN_2336 GBV_ILN_2446 GBV_ILN_2470 GBV_ILN_2472 GBV_ILN_2507 GBV_ILN_2522 GBV_ILN_2548 GBV_ILN_4012 GBV_ILN_4035 GBV_ILN_4037 GBV_ILN_4046 GBV_ILN_4112 GBV_ILN_4125 GBV_ILN_4126 GBV_ILN_4242 GBV_ILN_4246 GBV_ILN_4249 GBV_ILN_4251 GBV_ILN_4305 GBV_ILN_4306 GBV_ILN_4307 GBV_ILN_4313 GBV_ILN_4322 GBV_ILN_4323 GBV_ILN_4324 GBV_ILN_4325 GBV_ILN_4326 GBV_ILN_4328 GBV_ILN_4333 GBV_ILN_4334 GBV_ILN_4335 GBV_ILN_4336 GBV_ILN_4338 GBV_ILN_4393 GBV_ILN_4700 AR 20 2011 7 06 07 1307-1322 |
language |
English |
source |
Enthalten in Knee surgery, sports traumatology, arthroscopy 20(2011), 7 vom: 06. Juli, Seite 1307-1322 volume:20 year:2011 number:7 day:06 month:07 pages:1307-1322 |
sourceStr |
Enthalten in Knee surgery, sports traumatology, arthroscopy 20(2011), 7 vom: 06. Juli, Seite 1307-1322 volume:20 year:2011 number:7 day:06 month:07 pages:1307-1322 |
format_phy_str_mv |
Article |
institution |
findex.gbv.de |
topic_facet |
Computer-assisted surgery Navigation Total knee replacement TKR Meta-analysis Randomized controlled trial |
isfreeaccess_bool |
false |
container_title |
Knee surgery, sports traumatology, arthroscopy |
authorswithroles_txt_mv |
Cheng, Tao @@aut@@ Zhao, Song @@aut@@ Peng, Xiaochun @@aut@@ Zhang, Xianlong @@aut@@ |
publishDateDaySort_date |
2011-07-06T00:00:00Z |
hierarchy_top_id |
268761787 |
id |
SPR001383965 |
language_de |
englisch |
fullrecord |
<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim"><record><leader>01000caa a22002652 4500</leader><controlfield tag="001">SPR001383965</controlfield><controlfield tag="003">DE-627</controlfield><controlfield tag="005">20230519085234.0</controlfield><controlfield tag="007">cr uuu---uuuuu</controlfield><controlfield tag="008">201001s2011 xx |||||o 00| ||eng c</controlfield><datafield tag="024" ind1="7" ind2=" "><subfield code="a">10.1007/s00167-011-1588-8</subfield><subfield code="2">doi</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-627)SPR001383965</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(SPR)s00167-011-1588-8-e</subfield></datafield><datafield tag="040" ind1=" " ind2=" "><subfield code="a">DE-627</subfield><subfield code="b">ger</subfield><subfield code="c">DE-627</subfield><subfield code="e">rakwb</subfield></datafield><datafield tag="041" ind1=" " ind2=" "><subfield code="a">eng</subfield></datafield><datafield tag="100" ind1="1" ind2=" "><subfield code="a">Cheng, Tao</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="245" ind1="1" ind2="0"><subfield code="a">Does computer-assisted surgery improve postoperative leg alignment and implant positioning following total knee arthroplasty? A meta-analysis of randomized controlled trials?</subfield></datafield><datafield tag="264" ind1=" " ind2="1"><subfield code="c">2011</subfield></datafield><datafield tag="336" ind1=" " ind2=" "><subfield code="a">Text</subfield><subfield code="b">txt</subfield><subfield code="2">rdacontent</subfield></datafield><datafield tag="337" ind1=" " ind2=" "><subfield code="a">Computermedien</subfield><subfield code="b">c</subfield><subfield code="2">rdamedia</subfield></datafield><datafield tag="338" ind1=" " ind2=" "><subfield code="a">Online-Ressource</subfield><subfield code="b">cr</subfield><subfield code="2">rdacarrier</subfield></datafield><datafield tag="500" ind1=" " ind2=" "><subfield code="a">© Springer-Verlag 2011</subfield></datafield><datafield tag="520" ind1=" " ind2=" "><subfield code="a">Purpose Computer-assisted surgery has been proposed as a technique to improve implant alignment during total knee arthroplasty (TKA). However, there is still a debate over the accuracy of placing the femoral and tibial components using computer-assisted systems in TKA. The aim of this study is to establish whether computer-assisted surgery leads to superior mechanical leg axis and implant positioning than conventional technique in patients with primary TKA. Methods Major electronic databases were systematically searched to identify relevant studies without language restriction. A meta-analysis of 41 randomized controlled trials (RCTs) or quasi-RCTs was performed in a random effects model. A subgroup analysis was conducted by type of navigation system to explore the clinical heterogeneity between these trials. The following radiographic parameters were used to compare computer-assisted surgery with conventional technique: (1) mechanical leg axis, (2) femoral component coronal alignment, (3) tibial component coronal alignment, (4) femoral component sagittal alignment, and (5) tibial component sagittal alignment. Results For the mechanical leg axis and coronal positioning of femoral and tibial components, there are statistically significant reductions in the number of patients with malalignment in the CAS group if the outlier cutoff value is ±3 or 2° in the coronal and sagittal planes, respectively. Subgroup analysis demonstrates that CT-free navigation systems provide better alignment than conventional techniques in the coronal and sagittal alignment of femoral components within ±3 and 2°. If the outlier cutoff value for the tibial sagittal alignment is ±2°, the outlier percentages are higher in the CT-free navigation group than in the conventional group. However, there was no significant difference in the tibial sagittal alignment at ±3°. Conclusion Computer-assisted surgery does improve mechanical leg axis and component orientation in TKAs. However, high-quality RCTs are necessary to determine whether surgeons could use computer-assisted techniques to achieve a targeted tibial slope in TKA. Level of evidence Therapeutic study (Systematic review of Level I/II studies), Level II.</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Computer-assisted surgery</subfield><subfield code="7">(dpeaa)DE-He213</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Navigation</subfield><subfield code="7">(dpeaa)DE-He213</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Total knee replacement</subfield><subfield code="7">(dpeaa)DE-He213</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">TKR</subfield><subfield code="7">(dpeaa)DE-He213</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Meta-analysis</subfield><subfield code="7">(dpeaa)DE-He213</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Randomized controlled trial</subfield><subfield code="7">(dpeaa)DE-He213</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Zhao, Song</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Peng, Xiaochun</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Zhang, Xianlong</subfield><subfield code="4">aut</subfield></datafield><datafield tag="773" ind1="0" ind2="8"><subfield code="i">Enthalten in</subfield><subfield code="t">Knee surgery, sports traumatology, arthroscopy</subfield><subfield code="d">Berlin : Springer, 1993</subfield><subfield code="g">20(2011), 7 vom: 06. Juli, Seite 1307-1322</subfield><subfield code="w">(DE-627)268761787</subfield><subfield code="w">(DE-600)1473170-8</subfield><subfield code="x">1433-7347</subfield><subfield code="7">nnns</subfield></datafield><datafield tag="773" ind1="1" ind2="8"><subfield code="g">volume:20</subfield><subfield code="g">year:2011</subfield><subfield code="g">number:7</subfield><subfield code="g">day:06</subfield><subfield code="g">month:07</subfield><subfield code="g">pages:1307-1322</subfield></datafield><datafield tag="856" ind1="4" ind2="0"><subfield code="u">https://dx.doi.org/10.1007/s00167-011-1588-8</subfield><subfield code="z">lizenzpflichtig</subfield><subfield code="3">Volltext</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_USEFLAG_A</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">SYSFLAG_A</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_SPRINGER</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">SSG-OLC-PHA</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_11</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_20</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_22</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_23</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_24</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_31</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_32</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_39</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_40</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_60</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_62</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_63</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_69</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_70</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_73</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_74</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_90</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_95</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_100</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_101</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_105</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_110</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_120</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_138</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_150</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_151</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_152</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_161</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_165</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_170</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_171</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_187</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_213</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_224</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_230</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_250</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_267</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_281</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_285</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_293</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_370</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_602</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_636</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_702</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_711</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2001</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2003</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2004</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2005</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2006</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2007</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2009</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2010</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2011</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2014</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2015</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2020</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2021</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2025</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2026</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2027</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2031</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2034</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2037</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2038</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2039</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2044</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2048</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2049</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2050</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2055</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2056</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2057</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2059</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2061</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2064</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2065</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2068</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2070</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2086</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2088</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2093</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2106</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2107</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2108</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2110</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2111</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2112</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2113</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2116</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2118</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2119</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2122</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2129</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2143</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2144</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2147</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2148</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2152</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2153</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2188</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2190</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2232</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2336</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2446</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2470</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2472</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2507</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2522</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2548</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4012</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4035</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4037</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4046</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4112</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4125</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4126</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4242</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4246</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4249</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4251</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4305</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4306</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4307</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4313</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4322</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4323</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4324</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4325</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4326</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4328</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4333</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4334</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4335</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4336</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4338</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4393</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4700</subfield></datafield><datafield tag="951" ind1=" " ind2=" "><subfield code="a">AR</subfield></datafield><datafield tag="952" ind1=" " ind2=" "><subfield code="d">20</subfield><subfield code="j">2011</subfield><subfield code="e">7</subfield><subfield code="b">06</subfield><subfield code="c">07</subfield><subfield code="h">1307-1322</subfield></datafield></record></collection>
|
author |
Cheng, Tao |
spellingShingle |
Cheng, Tao misc Computer-assisted surgery misc Navigation misc Total knee replacement misc TKR misc Meta-analysis misc Randomized controlled trial Does computer-assisted surgery improve postoperative leg alignment and implant positioning following total knee arthroplasty? A meta-analysis of randomized controlled trials? |
authorStr |
Cheng, Tao |
ppnlink_with_tag_str_mv |
@@773@@(DE-627)268761787 |
format |
electronic Article |
delete_txt_mv |
keep |
author_role |
aut aut aut aut |
collection |
springer |
remote_str |
true |
illustrated |
Not Illustrated |
issn |
1433-7347 |
topic_title |
Does computer-assisted surgery improve postoperative leg alignment and implant positioning following total knee arthroplasty? A meta-analysis of randomized controlled trials? Computer-assisted surgery (dpeaa)DE-He213 Navigation (dpeaa)DE-He213 Total knee replacement (dpeaa)DE-He213 TKR (dpeaa)DE-He213 Meta-analysis (dpeaa)DE-He213 Randomized controlled trial (dpeaa)DE-He213 |
topic |
misc Computer-assisted surgery misc Navigation misc Total knee replacement misc TKR misc Meta-analysis misc Randomized controlled trial |
topic_unstemmed |
misc Computer-assisted surgery misc Navigation misc Total knee replacement misc TKR misc Meta-analysis misc Randomized controlled trial |
topic_browse |
misc Computer-assisted surgery misc Navigation misc Total knee replacement misc TKR misc Meta-analysis misc Randomized controlled trial |
format_facet |
Elektronische Aufsätze Aufsätze Elektronische Ressource |
format_main_str_mv |
Text Zeitschrift/Artikel |
carriertype_str_mv |
cr |
hierarchy_parent_title |
Knee surgery, sports traumatology, arthroscopy |
hierarchy_parent_id |
268761787 |
hierarchy_top_title |
Knee surgery, sports traumatology, arthroscopy |
isfreeaccess_txt |
false |
familylinks_str_mv |
(DE-627)268761787 (DE-600)1473170-8 |
title |
Does computer-assisted surgery improve postoperative leg alignment and implant positioning following total knee arthroplasty? A meta-analysis of randomized controlled trials? |
ctrlnum |
(DE-627)SPR001383965 (SPR)s00167-011-1588-8-e |
title_full |
Does computer-assisted surgery improve postoperative leg alignment and implant positioning following total knee arthroplasty? A meta-analysis of randomized controlled trials? |
author_sort |
Cheng, Tao |
journal |
Knee surgery, sports traumatology, arthroscopy |
journalStr |
Knee surgery, sports traumatology, arthroscopy |
lang_code |
eng |
isOA_bool |
false |
recordtype |
marc |
publishDateSort |
2011 |
contenttype_str_mv |
txt |
container_start_page |
1307 |
author_browse |
Cheng, Tao Zhao, Song Peng, Xiaochun Zhang, Xianlong |
container_volume |
20 |
format_se |
Elektronische Aufsätze |
author-letter |
Cheng, Tao |
doi_str_mv |
10.1007/s00167-011-1588-8 |
title_sort |
does computer-assisted surgery improve postoperative leg alignment and implant positioning following total knee arthroplasty? a meta-analysis of randomized controlled trials? |
title_auth |
Does computer-assisted surgery improve postoperative leg alignment and implant positioning following total knee arthroplasty? A meta-analysis of randomized controlled trials? |
abstract |
Purpose Computer-assisted surgery has been proposed as a technique to improve implant alignment during total knee arthroplasty (TKA). However, there is still a debate over the accuracy of placing the femoral and tibial components using computer-assisted systems in TKA. The aim of this study is to establish whether computer-assisted surgery leads to superior mechanical leg axis and implant positioning than conventional technique in patients with primary TKA. Methods Major electronic databases were systematically searched to identify relevant studies without language restriction. A meta-analysis of 41 randomized controlled trials (RCTs) or quasi-RCTs was performed in a random effects model. A subgroup analysis was conducted by type of navigation system to explore the clinical heterogeneity between these trials. The following radiographic parameters were used to compare computer-assisted surgery with conventional technique: (1) mechanical leg axis, (2) femoral component coronal alignment, (3) tibial component coronal alignment, (4) femoral component sagittal alignment, and (5) tibial component sagittal alignment. Results For the mechanical leg axis and coronal positioning of femoral and tibial components, there are statistically significant reductions in the number of patients with malalignment in the CAS group if the outlier cutoff value is ±3 or 2° in the coronal and sagittal planes, respectively. Subgroup analysis demonstrates that CT-free navigation systems provide better alignment than conventional techniques in the coronal and sagittal alignment of femoral components within ±3 and 2°. If the outlier cutoff value for the tibial sagittal alignment is ±2°, the outlier percentages are higher in the CT-free navigation group than in the conventional group. However, there was no significant difference in the tibial sagittal alignment at ±3°. Conclusion Computer-assisted surgery does improve mechanical leg axis and component orientation in TKAs. However, high-quality RCTs are necessary to determine whether surgeons could use computer-assisted techniques to achieve a targeted tibial slope in TKA. Level of evidence Therapeutic study (Systematic review of Level I/II studies), Level II. © Springer-Verlag 2011 |
abstractGer |
Purpose Computer-assisted surgery has been proposed as a technique to improve implant alignment during total knee arthroplasty (TKA). However, there is still a debate over the accuracy of placing the femoral and tibial components using computer-assisted systems in TKA. The aim of this study is to establish whether computer-assisted surgery leads to superior mechanical leg axis and implant positioning than conventional technique in patients with primary TKA. Methods Major electronic databases were systematically searched to identify relevant studies without language restriction. A meta-analysis of 41 randomized controlled trials (RCTs) or quasi-RCTs was performed in a random effects model. A subgroup analysis was conducted by type of navigation system to explore the clinical heterogeneity between these trials. The following radiographic parameters were used to compare computer-assisted surgery with conventional technique: (1) mechanical leg axis, (2) femoral component coronal alignment, (3) tibial component coronal alignment, (4) femoral component sagittal alignment, and (5) tibial component sagittal alignment. Results For the mechanical leg axis and coronal positioning of femoral and tibial components, there are statistically significant reductions in the number of patients with malalignment in the CAS group if the outlier cutoff value is ±3 or 2° in the coronal and sagittal planes, respectively. Subgroup analysis demonstrates that CT-free navigation systems provide better alignment than conventional techniques in the coronal and sagittal alignment of femoral components within ±3 and 2°. If the outlier cutoff value for the tibial sagittal alignment is ±2°, the outlier percentages are higher in the CT-free navigation group than in the conventional group. However, there was no significant difference in the tibial sagittal alignment at ±3°. Conclusion Computer-assisted surgery does improve mechanical leg axis and component orientation in TKAs. However, high-quality RCTs are necessary to determine whether surgeons could use computer-assisted techniques to achieve a targeted tibial slope in TKA. Level of evidence Therapeutic study (Systematic review of Level I/II studies), Level II. © Springer-Verlag 2011 |
abstract_unstemmed |
Purpose Computer-assisted surgery has been proposed as a technique to improve implant alignment during total knee arthroplasty (TKA). However, there is still a debate over the accuracy of placing the femoral and tibial components using computer-assisted systems in TKA. The aim of this study is to establish whether computer-assisted surgery leads to superior mechanical leg axis and implant positioning than conventional technique in patients with primary TKA. Methods Major electronic databases were systematically searched to identify relevant studies without language restriction. A meta-analysis of 41 randomized controlled trials (RCTs) or quasi-RCTs was performed in a random effects model. A subgroup analysis was conducted by type of navigation system to explore the clinical heterogeneity between these trials. The following radiographic parameters were used to compare computer-assisted surgery with conventional technique: (1) mechanical leg axis, (2) femoral component coronal alignment, (3) tibial component coronal alignment, (4) femoral component sagittal alignment, and (5) tibial component sagittal alignment. Results For the mechanical leg axis and coronal positioning of femoral and tibial components, there are statistically significant reductions in the number of patients with malalignment in the CAS group if the outlier cutoff value is ±3 or 2° in the coronal and sagittal planes, respectively. Subgroup analysis demonstrates that CT-free navigation systems provide better alignment than conventional techniques in the coronal and sagittal alignment of femoral components within ±3 and 2°. If the outlier cutoff value for the tibial sagittal alignment is ±2°, the outlier percentages are higher in the CT-free navigation group than in the conventional group. However, there was no significant difference in the tibial sagittal alignment at ±3°. Conclusion Computer-assisted surgery does improve mechanical leg axis and component orientation in TKAs. However, high-quality RCTs are necessary to determine whether surgeons could use computer-assisted techniques to achieve a targeted tibial slope in TKA. Level of evidence Therapeutic study (Systematic review of Level I/II studies), Level II. © Springer-Verlag 2011 |
collection_details |
GBV_USEFLAG_A SYSFLAG_A GBV_SPRINGER SSG-OLC-PHA GBV_ILN_11 GBV_ILN_20 GBV_ILN_22 GBV_ILN_23 GBV_ILN_24 GBV_ILN_31 GBV_ILN_32 GBV_ILN_39 GBV_ILN_40 GBV_ILN_60 GBV_ILN_62 GBV_ILN_63 GBV_ILN_69 GBV_ILN_70 GBV_ILN_73 GBV_ILN_74 GBV_ILN_90 GBV_ILN_95 GBV_ILN_100 GBV_ILN_101 GBV_ILN_105 GBV_ILN_110 GBV_ILN_120 GBV_ILN_138 GBV_ILN_150 GBV_ILN_151 GBV_ILN_152 GBV_ILN_161 GBV_ILN_165 GBV_ILN_170 GBV_ILN_171 GBV_ILN_187 GBV_ILN_213 GBV_ILN_224 GBV_ILN_230 GBV_ILN_250 GBV_ILN_267 GBV_ILN_281 GBV_ILN_285 GBV_ILN_293 GBV_ILN_370 GBV_ILN_602 GBV_ILN_636 GBV_ILN_702 GBV_ILN_711 GBV_ILN_2001 GBV_ILN_2003 GBV_ILN_2004 GBV_ILN_2005 GBV_ILN_2006 GBV_ILN_2007 GBV_ILN_2009 GBV_ILN_2010 GBV_ILN_2011 GBV_ILN_2014 GBV_ILN_2015 GBV_ILN_2020 GBV_ILN_2021 GBV_ILN_2025 GBV_ILN_2026 GBV_ILN_2027 GBV_ILN_2031 GBV_ILN_2034 GBV_ILN_2037 GBV_ILN_2038 GBV_ILN_2039 GBV_ILN_2044 GBV_ILN_2048 GBV_ILN_2049 GBV_ILN_2050 GBV_ILN_2055 GBV_ILN_2056 GBV_ILN_2057 GBV_ILN_2059 GBV_ILN_2061 GBV_ILN_2064 GBV_ILN_2065 GBV_ILN_2068 GBV_ILN_2070 GBV_ILN_2086 GBV_ILN_2088 GBV_ILN_2093 GBV_ILN_2106 GBV_ILN_2107 GBV_ILN_2108 GBV_ILN_2110 GBV_ILN_2111 GBV_ILN_2112 GBV_ILN_2113 GBV_ILN_2116 GBV_ILN_2118 GBV_ILN_2119 GBV_ILN_2122 GBV_ILN_2129 GBV_ILN_2143 GBV_ILN_2144 GBV_ILN_2147 GBV_ILN_2148 GBV_ILN_2152 GBV_ILN_2153 GBV_ILN_2188 GBV_ILN_2190 GBV_ILN_2232 GBV_ILN_2336 GBV_ILN_2446 GBV_ILN_2470 GBV_ILN_2472 GBV_ILN_2507 GBV_ILN_2522 GBV_ILN_2548 GBV_ILN_4012 GBV_ILN_4035 GBV_ILN_4037 GBV_ILN_4046 GBV_ILN_4112 GBV_ILN_4125 GBV_ILN_4126 GBV_ILN_4242 GBV_ILN_4246 GBV_ILN_4249 GBV_ILN_4251 GBV_ILN_4305 GBV_ILN_4306 GBV_ILN_4307 GBV_ILN_4313 GBV_ILN_4322 GBV_ILN_4323 GBV_ILN_4324 GBV_ILN_4325 GBV_ILN_4326 GBV_ILN_4328 GBV_ILN_4333 GBV_ILN_4334 GBV_ILN_4335 GBV_ILN_4336 GBV_ILN_4338 GBV_ILN_4393 GBV_ILN_4700 |
container_issue |
7 |
title_short |
Does computer-assisted surgery improve postoperative leg alignment and implant positioning following total knee arthroplasty? A meta-analysis of randomized controlled trials? |
url |
https://dx.doi.org/10.1007/s00167-011-1588-8 |
remote_bool |
true |
author2 |
Zhao, Song Peng, Xiaochun Zhang, Xianlong |
author2Str |
Zhao, Song Peng, Xiaochun Zhang, Xianlong |
ppnlink |
268761787 |
mediatype_str_mv |
c |
isOA_txt |
false |
hochschulschrift_bool |
false |
doi_str |
10.1007/s00167-011-1588-8 |
up_date |
2024-07-03T22:12:08.798Z |
_version_ |
1803597621550383104 |
fullrecord_marcxml |
<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim"><record><leader>01000caa a22002652 4500</leader><controlfield tag="001">SPR001383965</controlfield><controlfield tag="003">DE-627</controlfield><controlfield tag="005">20230519085234.0</controlfield><controlfield tag="007">cr uuu---uuuuu</controlfield><controlfield tag="008">201001s2011 xx |||||o 00| ||eng c</controlfield><datafield tag="024" ind1="7" ind2=" "><subfield code="a">10.1007/s00167-011-1588-8</subfield><subfield code="2">doi</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-627)SPR001383965</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(SPR)s00167-011-1588-8-e</subfield></datafield><datafield tag="040" ind1=" " ind2=" "><subfield code="a">DE-627</subfield><subfield code="b">ger</subfield><subfield code="c">DE-627</subfield><subfield code="e">rakwb</subfield></datafield><datafield tag="041" ind1=" " ind2=" "><subfield code="a">eng</subfield></datafield><datafield tag="100" ind1="1" ind2=" "><subfield code="a">Cheng, Tao</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="245" ind1="1" ind2="0"><subfield code="a">Does computer-assisted surgery improve postoperative leg alignment and implant positioning following total knee arthroplasty? A meta-analysis of randomized controlled trials?</subfield></datafield><datafield tag="264" ind1=" " ind2="1"><subfield code="c">2011</subfield></datafield><datafield tag="336" ind1=" " ind2=" "><subfield code="a">Text</subfield><subfield code="b">txt</subfield><subfield code="2">rdacontent</subfield></datafield><datafield tag="337" ind1=" " ind2=" "><subfield code="a">Computermedien</subfield><subfield code="b">c</subfield><subfield code="2">rdamedia</subfield></datafield><datafield tag="338" ind1=" " ind2=" "><subfield code="a">Online-Ressource</subfield><subfield code="b">cr</subfield><subfield code="2">rdacarrier</subfield></datafield><datafield tag="500" ind1=" " ind2=" "><subfield code="a">© Springer-Verlag 2011</subfield></datafield><datafield tag="520" ind1=" " ind2=" "><subfield code="a">Purpose Computer-assisted surgery has been proposed as a technique to improve implant alignment during total knee arthroplasty (TKA). However, there is still a debate over the accuracy of placing the femoral and tibial components using computer-assisted systems in TKA. The aim of this study is to establish whether computer-assisted surgery leads to superior mechanical leg axis and implant positioning than conventional technique in patients with primary TKA. Methods Major electronic databases were systematically searched to identify relevant studies without language restriction. A meta-analysis of 41 randomized controlled trials (RCTs) or quasi-RCTs was performed in a random effects model. A subgroup analysis was conducted by type of navigation system to explore the clinical heterogeneity between these trials. The following radiographic parameters were used to compare computer-assisted surgery with conventional technique: (1) mechanical leg axis, (2) femoral component coronal alignment, (3) tibial component coronal alignment, (4) femoral component sagittal alignment, and (5) tibial component sagittal alignment. Results For the mechanical leg axis and coronal positioning of femoral and tibial components, there are statistically significant reductions in the number of patients with malalignment in the CAS group if the outlier cutoff value is ±3 or 2° in the coronal and sagittal planes, respectively. Subgroup analysis demonstrates that CT-free navigation systems provide better alignment than conventional techniques in the coronal and sagittal alignment of femoral components within ±3 and 2°. If the outlier cutoff value for the tibial sagittal alignment is ±2°, the outlier percentages are higher in the CT-free navigation group than in the conventional group. However, there was no significant difference in the tibial sagittal alignment at ±3°. Conclusion Computer-assisted surgery does improve mechanical leg axis and component orientation in TKAs. However, high-quality RCTs are necessary to determine whether surgeons could use computer-assisted techniques to achieve a targeted tibial slope in TKA. Level of evidence Therapeutic study (Systematic review of Level I/II studies), Level II.</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Computer-assisted surgery</subfield><subfield code="7">(dpeaa)DE-He213</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Navigation</subfield><subfield code="7">(dpeaa)DE-He213</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Total knee replacement</subfield><subfield code="7">(dpeaa)DE-He213</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">TKR</subfield><subfield code="7">(dpeaa)DE-He213</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Meta-analysis</subfield><subfield code="7">(dpeaa)DE-He213</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Randomized controlled trial</subfield><subfield code="7">(dpeaa)DE-He213</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Zhao, Song</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Peng, Xiaochun</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Zhang, Xianlong</subfield><subfield code="4">aut</subfield></datafield><datafield tag="773" ind1="0" ind2="8"><subfield code="i">Enthalten in</subfield><subfield code="t">Knee surgery, sports traumatology, arthroscopy</subfield><subfield code="d">Berlin : Springer, 1993</subfield><subfield code="g">20(2011), 7 vom: 06. Juli, Seite 1307-1322</subfield><subfield code="w">(DE-627)268761787</subfield><subfield code="w">(DE-600)1473170-8</subfield><subfield code="x">1433-7347</subfield><subfield code="7">nnns</subfield></datafield><datafield tag="773" ind1="1" ind2="8"><subfield code="g">volume:20</subfield><subfield code="g">year:2011</subfield><subfield code="g">number:7</subfield><subfield code="g">day:06</subfield><subfield code="g">month:07</subfield><subfield code="g">pages:1307-1322</subfield></datafield><datafield tag="856" ind1="4" ind2="0"><subfield code="u">https://dx.doi.org/10.1007/s00167-011-1588-8</subfield><subfield code="z">lizenzpflichtig</subfield><subfield code="3">Volltext</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_USEFLAG_A</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">SYSFLAG_A</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_SPRINGER</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">SSG-OLC-PHA</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_11</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_20</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_22</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_23</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_24</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_31</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_32</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_39</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_40</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_60</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_62</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_63</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_69</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_70</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_73</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_74</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_90</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_95</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_100</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_101</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_105</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_110</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_120</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_138</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_150</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_151</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_152</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_161</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_165</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_170</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_171</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_187</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_213</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_224</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_230</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_250</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_267</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_281</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_285</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_293</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_370</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_602</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_636</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_702</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_711</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2001</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2003</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2004</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2005</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2006</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2007</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2009</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2010</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2011</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2014</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2015</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2020</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2021</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2025</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2026</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2027</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2031</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2034</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2037</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2038</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2039</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2044</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2048</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2049</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2050</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2055</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2056</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2057</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2059</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2061</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2064</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2065</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2068</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2070</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2086</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2088</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2093</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2106</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2107</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2108</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2110</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2111</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2112</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2113</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2116</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2118</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2119</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2122</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2129</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2143</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2144</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2147</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2148</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2152</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2153</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2188</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2190</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2232</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2336</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2446</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2470</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2472</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2507</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2522</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2548</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4012</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4035</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4037</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4046</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4112</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4125</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4126</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4242</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4246</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4249</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4251</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4305</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4306</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4307</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4313</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4322</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4323</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4324</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4325</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4326</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4328</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4333</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4334</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4335</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4336</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4338</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4393</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4700</subfield></datafield><datafield tag="951" ind1=" " ind2=" "><subfield code="a">AR</subfield></datafield><datafield tag="952" ind1=" " ind2=" "><subfield code="d">20</subfield><subfield code="j">2011</subfield><subfield code="e">7</subfield><subfield code="b">06</subfield><subfield code="c">07</subfield><subfield code="h">1307-1322</subfield></datafield></record></collection>
|
score |
7.400573 |