iPad-assisted percutaneous nephrolithotomy (PCNL): a matched pair analysis compared to standard PCNL
Purpose To compare iPad-assisted (Apple Inc., Cupertino, USA) percutaneous access to the kidney to the standard puncturing technique for percutaneous nephrolithotomy (PCNL). Methods For the iPad-assisted PCNL, a computed tomography is performed prior to surgery, using fiducial radiopaque markers. Th...
Ausführliche Beschreibung
Autor*in: |
Rassweiler-Seyfried, Marie-Claire [verfasserIn] |
---|
Format: |
E-Artikel |
---|---|
Sprache: |
Englisch |
Erschienen: |
2019 |
---|
Schlagwörter: |
---|
Anmerkung: |
© Springer-Verlag GmbH Germany, part of Springer Nature 2019 |
---|
Übergeordnetes Werk: |
Enthalten in: World journal of urology - Berlin : Springer, 1983, 38(2019), 2 vom: 09. Mai, Seite 447-453 |
---|---|
Übergeordnetes Werk: |
volume:38 ; year:2019 ; number:2 ; day:09 ; month:05 ; pages:447-453 |
Links: |
---|
DOI / URN: |
10.1007/s00345-019-02801-y |
---|
Katalog-ID: |
SPR004327063 |
---|
LEADER | 01000caa a22002652 4500 | ||
---|---|---|---|
001 | SPR004327063 | ||
003 | DE-627 | ||
005 | 20230519120707.0 | ||
007 | cr uuu---uuuuu | ||
008 | 201001s2019 xx |||||o 00| ||eng c | ||
024 | 7 | |a 10.1007/s00345-019-02801-y |2 doi | |
035 | |a (DE-627)SPR004327063 | ||
035 | |a (SPR)s00345-019-02801-y-e | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
100 | 1 | |a Rassweiler-Seyfried, Marie-Claire |e verfasserin |0 (orcid)0000-0003-1670-4072 |4 aut | |
245 | 1 | 0 | |a iPad-assisted percutaneous nephrolithotomy (PCNL): a matched pair analysis compared to standard PCNL |
264 | 1 | |c 2019 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a Computermedien |b c |2 rdamedia | ||
338 | |a Online-Ressource |b cr |2 rdacarrier | ||
500 | |a © Springer-Verlag GmbH Germany, part of Springer Nature 2019 | ||
520 | |a Purpose To compare iPad-assisted (Apple Inc., Cupertino, USA) percutaneous access to the kidney to the standard puncturing technique for percutaneous nephrolithotomy (PCNL). Methods For the iPad-assisted PCNL, a computed tomography is performed prior to surgery, using fiducial radiopaque markers. The important anatomical structures (i.e. kidney, stones) are segmented using specific software enabling the superimposition of images semi-transparently on the iPad by marker-based navigation. Twenty-two patients underwent an iPad-assisted percutaneous puncture of the kidney for PCNL. Twenty-two patients of the clinical database from the Urological Department SLK Hospital Heilbronn, who underwent the standard puncturing technique, were matched to these patients. Matching criteria were age, gender, stone volume, body mass index, stone site and the absence of anatomical variation. Puncture time, radiation exposure and number of attempts for a successful puncture were evaluated. All procedures were performed by two experienced urologists. The standard puncturing method consisted of a combination of ultrasound and fluoroscopy guidance. Chi-square and t test were used to ensure that there was no difference in the matching criteria between the groups. To compare the two methods, U test, Kruskal–Wallis and Chi-square test were used. Results Examination of radiation exposure showed a significant difference between the two groups in favour of the standard puncturing method (p < 0.01) and puncture time (p = 0.01). However, there was no significant difference in puncturing attempts (p = 0.45). Conclusion The iPad-assisted navigation, with the objective being to puncture the renal collecting system, represents a new technique (IDEAL criteria 2b), which proved to be applicable in clinical practice, but still has potential for technical improvement. | ||
650 | 4 | |a Navigation |7 (dpeaa)DE-He213 | |
650 | 4 | |a Percutaneous nephrolithotomy |7 (dpeaa)DE-He213 | |
650 | 4 | |a Urolithiasis |7 (dpeaa)DE-He213 | |
650 | 4 | |a Virtual reality |7 (dpeaa)DE-He213 | |
650 | 4 | |a Augmented reality |7 (dpeaa)DE-He213 | |
700 | 1 | |a Rassweiler, J. J. |4 aut | |
700 | 1 | |a Weiss, C. |4 aut | |
700 | 1 | |a Müller, M. |4 aut | |
700 | 1 | |a Meinzer, H. P. |4 aut | |
700 | 1 | |a Maier-Hein, L. |4 aut | |
700 | 1 | |a Klein, J. T. |4 aut | |
773 | 0 | 8 | |i Enthalten in |t World journal of urology |d Berlin : Springer, 1983 |g 38(2019), 2 vom: 09. Mai, Seite 447-453 |w (DE-627)254910874 |w (DE-600)1463303-6 |x 1433-8726 |7 nnns |
773 | 1 | 8 | |g volume:38 |g year:2019 |g number:2 |g day:09 |g month:05 |g pages:447-453 |
856 | 4 | 0 | |u https://dx.doi.org/10.1007/s00345-019-02801-y |z lizenzpflichtig |3 Volltext |
912 | |a GBV_USEFLAG_A | ||
912 | |a SYSFLAG_A | ||
912 | |a GBV_SPRINGER | ||
912 | |a SSG-OLC-PHA | ||
912 | |a GBV_ILN_11 | ||
912 | |a GBV_ILN_20 | ||
912 | |a GBV_ILN_22 | ||
912 | |a GBV_ILN_23 | ||
912 | |a GBV_ILN_24 | ||
912 | |a GBV_ILN_31 | ||
912 | |a GBV_ILN_32 | ||
912 | |a GBV_ILN_39 | ||
912 | |a GBV_ILN_40 | ||
912 | |a GBV_ILN_60 | ||
912 | |a GBV_ILN_62 | ||
912 | |a GBV_ILN_63 | ||
912 | |a GBV_ILN_69 | ||
912 | |a GBV_ILN_70 | ||
912 | |a GBV_ILN_73 | ||
912 | |a GBV_ILN_74 | ||
912 | |a GBV_ILN_90 | ||
912 | |a GBV_ILN_95 | ||
912 | |a GBV_ILN_100 | ||
912 | |a GBV_ILN_101 | ||
912 | |a GBV_ILN_105 | ||
912 | |a GBV_ILN_110 | ||
912 | |a GBV_ILN_120 | ||
912 | |a GBV_ILN_138 | ||
912 | |a GBV_ILN_150 | ||
912 | |a GBV_ILN_151 | ||
912 | |a GBV_ILN_152 | ||
912 | |a GBV_ILN_161 | ||
912 | |a GBV_ILN_170 | ||
912 | |a GBV_ILN_171 | ||
912 | |a GBV_ILN_187 | ||
912 | |a GBV_ILN_213 | ||
912 | |a GBV_ILN_224 | ||
912 | |a GBV_ILN_230 | ||
912 | |a GBV_ILN_250 | ||
912 | |a GBV_ILN_267 | ||
912 | |a GBV_ILN_281 | ||
912 | |a GBV_ILN_285 | ||
912 | |a GBV_ILN_293 | ||
912 | |a GBV_ILN_370 | ||
912 | |a GBV_ILN_602 | ||
912 | |a GBV_ILN_636 | ||
912 | |a GBV_ILN_702 | ||
912 | |a GBV_ILN_711 | ||
912 | |a GBV_ILN_2001 | ||
912 | |a GBV_ILN_2003 | ||
912 | |a GBV_ILN_2004 | ||
912 | |a GBV_ILN_2005 | ||
912 | |a GBV_ILN_2006 | ||
912 | |a GBV_ILN_2007 | ||
912 | |a GBV_ILN_2008 | ||
912 | |a GBV_ILN_2009 | ||
912 | |a GBV_ILN_2010 | ||
912 | |a GBV_ILN_2011 | ||
912 | |a GBV_ILN_2014 | ||
912 | |a GBV_ILN_2015 | ||
912 | |a GBV_ILN_2020 | ||
912 | |a GBV_ILN_2021 | ||
912 | |a GBV_ILN_2025 | ||
912 | |a GBV_ILN_2026 | ||
912 | |a GBV_ILN_2027 | ||
912 | |a GBV_ILN_2031 | ||
912 | |a GBV_ILN_2034 | ||
912 | |a GBV_ILN_2037 | ||
912 | |a GBV_ILN_2038 | ||
912 | |a GBV_ILN_2039 | ||
912 | |a GBV_ILN_2044 | ||
912 | |a GBV_ILN_2048 | ||
912 | |a GBV_ILN_2049 | ||
912 | |a GBV_ILN_2050 | ||
912 | |a GBV_ILN_2055 | ||
912 | |a GBV_ILN_2057 | ||
912 | |a GBV_ILN_2059 | ||
912 | |a GBV_ILN_2061 | ||
912 | |a GBV_ILN_2064 | ||
912 | |a GBV_ILN_2065 | ||
912 | |a GBV_ILN_2068 | ||
912 | |a GBV_ILN_2070 | ||
912 | |a GBV_ILN_2086 | ||
912 | |a GBV_ILN_2088 | ||
912 | |a GBV_ILN_2093 | ||
912 | |a GBV_ILN_2106 | ||
912 | |a GBV_ILN_2107 | ||
912 | |a GBV_ILN_2108 | ||
912 | |a GBV_ILN_2110 | ||
912 | |a GBV_ILN_2111 | ||
912 | |a GBV_ILN_2112 | ||
912 | |a GBV_ILN_2113 | ||
912 | |a GBV_ILN_2116 | ||
912 | |a GBV_ILN_2118 | ||
912 | |a GBV_ILN_2119 | ||
912 | |a GBV_ILN_2122 | ||
912 | |a GBV_ILN_2129 | ||
912 | |a GBV_ILN_2143 | ||
912 | |a GBV_ILN_2144 | ||
912 | |a GBV_ILN_2147 | ||
912 | |a GBV_ILN_2148 | ||
912 | |a GBV_ILN_2152 | ||
912 | |a GBV_ILN_2153 | ||
912 | |a GBV_ILN_2188 | ||
912 | |a GBV_ILN_2190 | ||
912 | |a GBV_ILN_2232 | ||
912 | |a GBV_ILN_2336 | ||
912 | |a GBV_ILN_2446 | ||
912 | |a GBV_ILN_2470 | ||
912 | |a GBV_ILN_2472 | ||
912 | |a GBV_ILN_2507 | ||
912 | |a GBV_ILN_2522 | ||
912 | |a GBV_ILN_2548 | ||
912 | |a GBV_ILN_4035 | ||
912 | |a GBV_ILN_4037 | ||
912 | |a GBV_ILN_4046 | ||
912 | |a GBV_ILN_4112 | ||
912 | |a GBV_ILN_4125 | ||
912 | |a GBV_ILN_4242 | ||
912 | |a GBV_ILN_4246 | ||
912 | |a GBV_ILN_4249 | ||
912 | |a GBV_ILN_4251 | ||
912 | |a GBV_ILN_4305 | ||
912 | |a GBV_ILN_4306 | ||
912 | |a GBV_ILN_4307 | ||
912 | |a GBV_ILN_4313 | ||
912 | |a GBV_ILN_4322 | ||
912 | |a GBV_ILN_4323 | ||
912 | |a GBV_ILN_4324 | ||
912 | |a GBV_ILN_4325 | ||
912 | |a GBV_ILN_4326 | ||
912 | |a GBV_ILN_4328 | ||
912 | |a GBV_ILN_4333 | ||
912 | |a GBV_ILN_4334 | ||
912 | |a GBV_ILN_4335 | ||
912 | |a GBV_ILN_4336 | ||
912 | |a GBV_ILN_4338 | ||
912 | |a GBV_ILN_4393 | ||
912 | |a GBV_ILN_4700 | ||
951 | |a AR | ||
952 | |d 38 |j 2019 |e 2 |b 09 |c 05 |h 447-453 |
author_variant |
m c r s mcrs j j r jj jjr c w cw m m mm h p m hp hpm l m h lmh j t k jt jtk |
---|---|
matchkey_str |
article:14338726:2019----::pdsitdectnosehoihtmpnaacepiaayi |
hierarchy_sort_str |
2019 |
publishDate |
2019 |
allfields |
10.1007/s00345-019-02801-y doi (DE-627)SPR004327063 (SPR)s00345-019-02801-y-e DE-627 ger DE-627 rakwb eng Rassweiler-Seyfried, Marie-Claire verfasserin (orcid)0000-0003-1670-4072 aut iPad-assisted percutaneous nephrolithotomy (PCNL): a matched pair analysis compared to standard PCNL 2019 Text txt rdacontent Computermedien c rdamedia Online-Ressource cr rdacarrier © Springer-Verlag GmbH Germany, part of Springer Nature 2019 Purpose To compare iPad-assisted (Apple Inc., Cupertino, USA) percutaneous access to the kidney to the standard puncturing technique for percutaneous nephrolithotomy (PCNL). Methods For the iPad-assisted PCNL, a computed tomography is performed prior to surgery, using fiducial radiopaque markers. The important anatomical structures (i.e. kidney, stones) are segmented using specific software enabling the superimposition of images semi-transparently on the iPad by marker-based navigation. Twenty-two patients underwent an iPad-assisted percutaneous puncture of the kidney for PCNL. Twenty-two patients of the clinical database from the Urological Department SLK Hospital Heilbronn, who underwent the standard puncturing technique, were matched to these patients. Matching criteria were age, gender, stone volume, body mass index, stone site and the absence of anatomical variation. Puncture time, radiation exposure and number of attempts for a successful puncture were evaluated. All procedures were performed by two experienced urologists. The standard puncturing method consisted of a combination of ultrasound and fluoroscopy guidance. Chi-square and t test were used to ensure that there was no difference in the matching criteria between the groups. To compare the two methods, U test, Kruskal–Wallis and Chi-square test were used. Results Examination of radiation exposure showed a significant difference between the two groups in favour of the standard puncturing method (p < 0.01) and puncture time (p = 0.01). However, there was no significant difference in puncturing attempts (p = 0.45). Conclusion The iPad-assisted navigation, with the objective being to puncture the renal collecting system, represents a new technique (IDEAL criteria 2b), which proved to be applicable in clinical practice, but still has potential for technical improvement. Navigation (dpeaa)DE-He213 Percutaneous nephrolithotomy (dpeaa)DE-He213 Urolithiasis (dpeaa)DE-He213 Virtual reality (dpeaa)DE-He213 Augmented reality (dpeaa)DE-He213 Rassweiler, J. J. aut Weiss, C. aut Müller, M. aut Meinzer, H. P. aut Maier-Hein, L. aut Klein, J. T. aut Enthalten in World journal of urology Berlin : Springer, 1983 38(2019), 2 vom: 09. Mai, Seite 447-453 (DE-627)254910874 (DE-600)1463303-6 1433-8726 nnns volume:38 year:2019 number:2 day:09 month:05 pages:447-453 https://dx.doi.org/10.1007/s00345-019-02801-y lizenzpflichtig Volltext GBV_USEFLAG_A SYSFLAG_A GBV_SPRINGER SSG-OLC-PHA GBV_ILN_11 GBV_ILN_20 GBV_ILN_22 GBV_ILN_23 GBV_ILN_24 GBV_ILN_31 GBV_ILN_32 GBV_ILN_39 GBV_ILN_40 GBV_ILN_60 GBV_ILN_62 GBV_ILN_63 GBV_ILN_69 GBV_ILN_70 GBV_ILN_73 GBV_ILN_74 GBV_ILN_90 GBV_ILN_95 GBV_ILN_100 GBV_ILN_101 GBV_ILN_105 GBV_ILN_110 GBV_ILN_120 GBV_ILN_138 GBV_ILN_150 GBV_ILN_151 GBV_ILN_152 GBV_ILN_161 GBV_ILN_170 GBV_ILN_171 GBV_ILN_187 GBV_ILN_213 GBV_ILN_224 GBV_ILN_230 GBV_ILN_250 GBV_ILN_267 GBV_ILN_281 GBV_ILN_285 GBV_ILN_293 GBV_ILN_370 GBV_ILN_602 GBV_ILN_636 GBV_ILN_702 GBV_ILN_711 GBV_ILN_2001 GBV_ILN_2003 GBV_ILN_2004 GBV_ILN_2005 GBV_ILN_2006 GBV_ILN_2007 GBV_ILN_2008 GBV_ILN_2009 GBV_ILN_2010 GBV_ILN_2011 GBV_ILN_2014 GBV_ILN_2015 GBV_ILN_2020 GBV_ILN_2021 GBV_ILN_2025 GBV_ILN_2026 GBV_ILN_2027 GBV_ILN_2031 GBV_ILN_2034 GBV_ILN_2037 GBV_ILN_2038 GBV_ILN_2039 GBV_ILN_2044 GBV_ILN_2048 GBV_ILN_2049 GBV_ILN_2050 GBV_ILN_2055 GBV_ILN_2057 GBV_ILN_2059 GBV_ILN_2061 GBV_ILN_2064 GBV_ILN_2065 GBV_ILN_2068 GBV_ILN_2070 GBV_ILN_2086 GBV_ILN_2088 GBV_ILN_2093 GBV_ILN_2106 GBV_ILN_2107 GBV_ILN_2108 GBV_ILN_2110 GBV_ILN_2111 GBV_ILN_2112 GBV_ILN_2113 GBV_ILN_2116 GBV_ILN_2118 GBV_ILN_2119 GBV_ILN_2122 GBV_ILN_2129 GBV_ILN_2143 GBV_ILN_2144 GBV_ILN_2147 GBV_ILN_2148 GBV_ILN_2152 GBV_ILN_2153 GBV_ILN_2188 GBV_ILN_2190 GBV_ILN_2232 GBV_ILN_2336 GBV_ILN_2446 GBV_ILN_2470 GBV_ILN_2472 GBV_ILN_2507 GBV_ILN_2522 GBV_ILN_2548 GBV_ILN_4035 GBV_ILN_4037 GBV_ILN_4046 GBV_ILN_4112 GBV_ILN_4125 GBV_ILN_4242 GBV_ILN_4246 GBV_ILN_4249 GBV_ILN_4251 GBV_ILN_4305 GBV_ILN_4306 GBV_ILN_4307 GBV_ILN_4313 GBV_ILN_4322 GBV_ILN_4323 GBV_ILN_4324 GBV_ILN_4325 GBV_ILN_4326 GBV_ILN_4328 GBV_ILN_4333 GBV_ILN_4334 GBV_ILN_4335 GBV_ILN_4336 GBV_ILN_4338 GBV_ILN_4393 GBV_ILN_4700 AR 38 2019 2 09 05 447-453 |
spelling |
10.1007/s00345-019-02801-y doi (DE-627)SPR004327063 (SPR)s00345-019-02801-y-e DE-627 ger DE-627 rakwb eng Rassweiler-Seyfried, Marie-Claire verfasserin (orcid)0000-0003-1670-4072 aut iPad-assisted percutaneous nephrolithotomy (PCNL): a matched pair analysis compared to standard PCNL 2019 Text txt rdacontent Computermedien c rdamedia Online-Ressource cr rdacarrier © Springer-Verlag GmbH Germany, part of Springer Nature 2019 Purpose To compare iPad-assisted (Apple Inc., Cupertino, USA) percutaneous access to the kidney to the standard puncturing technique for percutaneous nephrolithotomy (PCNL). Methods For the iPad-assisted PCNL, a computed tomography is performed prior to surgery, using fiducial radiopaque markers. The important anatomical structures (i.e. kidney, stones) are segmented using specific software enabling the superimposition of images semi-transparently on the iPad by marker-based navigation. Twenty-two patients underwent an iPad-assisted percutaneous puncture of the kidney for PCNL. Twenty-two patients of the clinical database from the Urological Department SLK Hospital Heilbronn, who underwent the standard puncturing technique, were matched to these patients. Matching criteria were age, gender, stone volume, body mass index, stone site and the absence of anatomical variation. Puncture time, radiation exposure and number of attempts for a successful puncture were evaluated. All procedures were performed by two experienced urologists. The standard puncturing method consisted of a combination of ultrasound and fluoroscopy guidance. Chi-square and t test were used to ensure that there was no difference in the matching criteria between the groups. To compare the two methods, U test, Kruskal–Wallis and Chi-square test were used. Results Examination of radiation exposure showed a significant difference between the two groups in favour of the standard puncturing method (p < 0.01) and puncture time (p = 0.01). However, there was no significant difference in puncturing attempts (p = 0.45). Conclusion The iPad-assisted navigation, with the objective being to puncture the renal collecting system, represents a new technique (IDEAL criteria 2b), which proved to be applicable in clinical practice, but still has potential for technical improvement. Navigation (dpeaa)DE-He213 Percutaneous nephrolithotomy (dpeaa)DE-He213 Urolithiasis (dpeaa)DE-He213 Virtual reality (dpeaa)DE-He213 Augmented reality (dpeaa)DE-He213 Rassweiler, J. J. aut Weiss, C. aut Müller, M. aut Meinzer, H. P. aut Maier-Hein, L. aut Klein, J. T. aut Enthalten in World journal of urology Berlin : Springer, 1983 38(2019), 2 vom: 09. Mai, Seite 447-453 (DE-627)254910874 (DE-600)1463303-6 1433-8726 nnns volume:38 year:2019 number:2 day:09 month:05 pages:447-453 https://dx.doi.org/10.1007/s00345-019-02801-y lizenzpflichtig Volltext GBV_USEFLAG_A SYSFLAG_A GBV_SPRINGER SSG-OLC-PHA GBV_ILN_11 GBV_ILN_20 GBV_ILN_22 GBV_ILN_23 GBV_ILN_24 GBV_ILN_31 GBV_ILN_32 GBV_ILN_39 GBV_ILN_40 GBV_ILN_60 GBV_ILN_62 GBV_ILN_63 GBV_ILN_69 GBV_ILN_70 GBV_ILN_73 GBV_ILN_74 GBV_ILN_90 GBV_ILN_95 GBV_ILN_100 GBV_ILN_101 GBV_ILN_105 GBV_ILN_110 GBV_ILN_120 GBV_ILN_138 GBV_ILN_150 GBV_ILN_151 GBV_ILN_152 GBV_ILN_161 GBV_ILN_170 GBV_ILN_171 GBV_ILN_187 GBV_ILN_213 GBV_ILN_224 GBV_ILN_230 GBV_ILN_250 GBV_ILN_267 GBV_ILN_281 GBV_ILN_285 GBV_ILN_293 GBV_ILN_370 GBV_ILN_602 GBV_ILN_636 GBV_ILN_702 GBV_ILN_711 GBV_ILN_2001 GBV_ILN_2003 GBV_ILN_2004 GBV_ILN_2005 GBV_ILN_2006 GBV_ILN_2007 GBV_ILN_2008 GBV_ILN_2009 GBV_ILN_2010 GBV_ILN_2011 GBV_ILN_2014 GBV_ILN_2015 GBV_ILN_2020 GBV_ILN_2021 GBV_ILN_2025 GBV_ILN_2026 GBV_ILN_2027 GBV_ILN_2031 GBV_ILN_2034 GBV_ILN_2037 GBV_ILN_2038 GBV_ILN_2039 GBV_ILN_2044 GBV_ILN_2048 GBV_ILN_2049 GBV_ILN_2050 GBV_ILN_2055 GBV_ILN_2057 GBV_ILN_2059 GBV_ILN_2061 GBV_ILN_2064 GBV_ILN_2065 GBV_ILN_2068 GBV_ILN_2070 GBV_ILN_2086 GBV_ILN_2088 GBV_ILN_2093 GBV_ILN_2106 GBV_ILN_2107 GBV_ILN_2108 GBV_ILN_2110 GBV_ILN_2111 GBV_ILN_2112 GBV_ILN_2113 GBV_ILN_2116 GBV_ILN_2118 GBV_ILN_2119 GBV_ILN_2122 GBV_ILN_2129 GBV_ILN_2143 GBV_ILN_2144 GBV_ILN_2147 GBV_ILN_2148 GBV_ILN_2152 GBV_ILN_2153 GBV_ILN_2188 GBV_ILN_2190 GBV_ILN_2232 GBV_ILN_2336 GBV_ILN_2446 GBV_ILN_2470 GBV_ILN_2472 GBV_ILN_2507 GBV_ILN_2522 GBV_ILN_2548 GBV_ILN_4035 GBV_ILN_4037 GBV_ILN_4046 GBV_ILN_4112 GBV_ILN_4125 GBV_ILN_4242 GBV_ILN_4246 GBV_ILN_4249 GBV_ILN_4251 GBV_ILN_4305 GBV_ILN_4306 GBV_ILN_4307 GBV_ILN_4313 GBV_ILN_4322 GBV_ILN_4323 GBV_ILN_4324 GBV_ILN_4325 GBV_ILN_4326 GBV_ILN_4328 GBV_ILN_4333 GBV_ILN_4334 GBV_ILN_4335 GBV_ILN_4336 GBV_ILN_4338 GBV_ILN_4393 GBV_ILN_4700 AR 38 2019 2 09 05 447-453 |
allfields_unstemmed |
10.1007/s00345-019-02801-y doi (DE-627)SPR004327063 (SPR)s00345-019-02801-y-e DE-627 ger DE-627 rakwb eng Rassweiler-Seyfried, Marie-Claire verfasserin (orcid)0000-0003-1670-4072 aut iPad-assisted percutaneous nephrolithotomy (PCNL): a matched pair analysis compared to standard PCNL 2019 Text txt rdacontent Computermedien c rdamedia Online-Ressource cr rdacarrier © Springer-Verlag GmbH Germany, part of Springer Nature 2019 Purpose To compare iPad-assisted (Apple Inc., Cupertino, USA) percutaneous access to the kidney to the standard puncturing technique for percutaneous nephrolithotomy (PCNL). Methods For the iPad-assisted PCNL, a computed tomography is performed prior to surgery, using fiducial radiopaque markers. The important anatomical structures (i.e. kidney, stones) are segmented using specific software enabling the superimposition of images semi-transparently on the iPad by marker-based navigation. Twenty-two patients underwent an iPad-assisted percutaneous puncture of the kidney for PCNL. Twenty-two patients of the clinical database from the Urological Department SLK Hospital Heilbronn, who underwent the standard puncturing technique, were matched to these patients. Matching criteria were age, gender, stone volume, body mass index, stone site and the absence of anatomical variation. Puncture time, radiation exposure and number of attempts for a successful puncture were evaluated. All procedures were performed by two experienced urologists. The standard puncturing method consisted of a combination of ultrasound and fluoroscopy guidance. Chi-square and t test were used to ensure that there was no difference in the matching criteria between the groups. To compare the two methods, U test, Kruskal–Wallis and Chi-square test were used. Results Examination of radiation exposure showed a significant difference between the two groups in favour of the standard puncturing method (p < 0.01) and puncture time (p = 0.01). However, there was no significant difference in puncturing attempts (p = 0.45). Conclusion The iPad-assisted navigation, with the objective being to puncture the renal collecting system, represents a new technique (IDEAL criteria 2b), which proved to be applicable in clinical practice, but still has potential for technical improvement. Navigation (dpeaa)DE-He213 Percutaneous nephrolithotomy (dpeaa)DE-He213 Urolithiasis (dpeaa)DE-He213 Virtual reality (dpeaa)DE-He213 Augmented reality (dpeaa)DE-He213 Rassweiler, J. J. aut Weiss, C. aut Müller, M. aut Meinzer, H. P. aut Maier-Hein, L. aut Klein, J. T. aut Enthalten in World journal of urology Berlin : Springer, 1983 38(2019), 2 vom: 09. Mai, Seite 447-453 (DE-627)254910874 (DE-600)1463303-6 1433-8726 nnns volume:38 year:2019 number:2 day:09 month:05 pages:447-453 https://dx.doi.org/10.1007/s00345-019-02801-y lizenzpflichtig Volltext GBV_USEFLAG_A SYSFLAG_A GBV_SPRINGER SSG-OLC-PHA GBV_ILN_11 GBV_ILN_20 GBV_ILN_22 GBV_ILN_23 GBV_ILN_24 GBV_ILN_31 GBV_ILN_32 GBV_ILN_39 GBV_ILN_40 GBV_ILN_60 GBV_ILN_62 GBV_ILN_63 GBV_ILN_69 GBV_ILN_70 GBV_ILN_73 GBV_ILN_74 GBV_ILN_90 GBV_ILN_95 GBV_ILN_100 GBV_ILN_101 GBV_ILN_105 GBV_ILN_110 GBV_ILN_120 GBV_ILN_138 GBV_ILN_150 GBV_ILN_151 GBV_ILN_152 GBV_ILN_161 GBV_ILN_170 GBV_ILN_171 GBV_ILN_187 GBV_ILN_213 GBV_ILN_224 GBV_ILN_230 GBV_ILN_250 GBV_ILN_267 GBV_ILN_281 GBV_ILN_285 GBV_ILN_293 GBV_ILN_370 GBV_ILN_602 GBV_ILN_636 GBV_ILN_702 GBV_ILN_711 GBV_ILN_2001 GBV_ILN_2003 GBV_ILN_2004 GBV_ILN_2005 GBV_ILN_2006 GBV_ILN_2007 GBV_ILN_2008 GBV_ILN_2009 GBV_ILN_2010 GBV_ILN_2011 GBV_ILN_2014 GBV_ILN_2015 GBV_ILN_2020 GBV_ILN_2021 GBV_ILN_2025 GBV_ILN_2026 GBV_ILN_2027 GBV_ILN_2031 GBV_ILN_2034 GBV_ILN_2037 GBV_ILN_2038 GBV_ILN_2039 GBV_ILN_2044 GBV_ILN_2048 GBV_ILN_2049 GBV_ILN_2050 GBV_ILN_2055 GBV_ILN_2057 GBV_ILN_2059 GBV_ILN_2061 GBV_ILN_2064 GBV_ILN_2065 GBV_ILN_2068 GBV_ILN_2070 GBV_ILN_2086 GBV_ILN_2088 GBV_ILN_2093 GBV_ILN_2106 GBV_ILN_2107 GBV_ILN_2108 GBV_ILN_2110 GBV_ILN_2111 GBV_ILN_2112 GBV_ILN_2113 GBV_ILN_2116 GBV_ILN_2118 GBV_ILN_2119 GBV_ILN_2122 GBV_ILN_2129 GBV_ILN_2143 GBV_ILN_2144 GBV_ILN_2147 GBV_ILN_2148 GBV_ILN_2152 GBV_ILN_2153 GBV_ILN_2188 GBV_ILN_2190 GBV_ILN_2232 GBV_ILN_2336 GBV_ILN_2446 GBV_ILN_2470 GBV_ILN_2472 GBV_ILN_2507 GBV_ILN_2522 GBV_ILN_2548 GBV_ILN_4035 GBV_ILN_4037 GBV_ILN_4046 GBV_ILN_4112 GBV_ILN_4125 GBV_ILN_4242 GBV_ILN_4246 GBV_ILN_4249 GBV_ILN_4251 GBV_ILN_4305 GBV_ILN_4306 GBV_ILN_4307 GBV_ILN_4313 GBV_ILN_4322 GBV_ILN_4323 GBV_ILN_4324 GBV_ILN_4325 GBV_ILN_4326 GBV_ILN_4328 GBV_ILN_4333 GBV_ILN_4334 GBV_ILN_4335 GBV_ILN_4336 GBV_ILN_4338 GBV_ILN_4393 GBV_ILN_4700 AR 38 2019 2 09 05 447-453 |
allfieldsGer |
10.1007/s00345-019-02801-y doi (DE-627)SPR004327063 (SPR)s00345-019-02801-y-e DE-627 ger DE-627 rakwb eng Rassweiler-Seyfried, Marie-Claire verfasserin (orcid)0000-0003-1670-4072 aut iPad-assisted percutaneous nephrolithotomy (PCNL): a matched pair analysis compared to standard PCNL 2019 Text txt rdacontent Computermedien c rdamedia Online-Ressource cr rdacarrier © Springer-Verlag GmbH Germany, part of Springer Nature 2019 Purpose To compare iPad-assisted (Apple Inc., Cupertino, USA) percutaneous access to the kidney to the standard puncturing technique for percutaneous nephrolithotomy (PCNL). Methods For the iPad-assisted PCNL, a computed tomography is performed prior to surgery, using fiducial radiopaque markers. The important anatomical structures (i.e. kidney, stones) are segmented using specific software enabling the superimposition of images semi-transparently on the iPad by marker-based navigation. Twenty-two patients underwent an iPad-assisted percutaneous puncture of the kidney for PCNL. Twenty-two patients of the clinical database from the Urological Department SLK Hospital Heilbronn, who underwent the standard puncturing technique, were matched to these patients. Matching criteria were age, gender, stone volume, body mass index, stone site and the absence of anatomical variation. Puncture time, radiation exposure and number of attempts for a successful puncture were evaluated. All procedures were performed by two experienced urologists. The standard puncturing method consisted of a combination of ultrasound and fluoroscopy guidance. Chi-square and t test were used to ensure that there was no difference in the matching criteria between the groups. To compare the two methods, U test, Kruskal–Wallis and Chi-square test were used. Results Examination of radiation exposure showed a significant difference between the two groups in favour of the standard puncturing method (p < 0.01) and puncture time (p = 0.01). However, there was no significant difference in puncturing attempts (p = 0.45). Conclusion The iPad-assisted navigation, with the objective being to puncture the renal collecting system, represents a new technique (IDEAL criteria 2b), which proved to be applicable in clinical practice, but still has potential for technical improvement. Navigation (dpeaa)DE-He213 Percutaneous nephrolithotomy (dpeaa)DE-He213 Urolithiasis (dpeaa)DE-He213 Virtual reality (dpeaa)DE-He213 Augmented reality (dpeaa)DE-He213 Rassweiler, J. J. aut Weiss, C. aut Müller, M. aut Meinzer, H. P. aut Maier-Hein, L. aut Klein, J. T. aut Enthalten in World journal of urology Berlin : Springer, 1983 38(2019), 2 vom: 09. Mai, Seite 447-453 (DE-627)254910874 (DE-600)1463303-6 1433-8726 nnns volume:38 year:2019 number:2 day:09 month:05 pages:447-453 https://dx.doi.org/10.1007/s00345-019-02801-y lizenzpflichtig Volltext GBV_USEFLAG_A SYSFLAG_A GBV_SPRINGER SSG-OLC-PHA GBV_ILN_11 GBV_ILN_20 GBV_ILN_22 GBV_ILN_23 GBV_ILN_24 GBV_ILN_31 GBV_ILN_32 GBV_ILN_39 GBV_ILN_40 GBV_ILN_60 GBV_ILN_62 GBV_ILN_63 GBV_ILN_69 GBV_ILN_70 GBV_ILN_73 GBV_ILN_74 GBV_ILN_90 GBV_ILN_95 GBV_ILN_100 GBV_ILN_101 GBV_ILN_105 GBV_ILN_110 GBV_ILN_120 GBV_ILN_138 GBV_ILN_150 GBV_ILN_151 GBV_ILN_152 GBV_ILN_161 GBV_ILN_170 GBV_ILN_171 GBV_ILN_187 GBV_ILN_213 GBV_ILN_224 GBV_ILN_230 GBV_ILN_250 GBV_ILN_267 GBV_ILN_281 GBV_ILN_285 GBV_ILN_293 GBV_ILN_370 GBV_ILN_602 GBV_ILN_636 GBV_ILN_702 GBV_ILN_711 GBV_ILN_2001 GBV_ILN_2003 GBV_ILN_2004 GBV_ILN_2005 GBV_ILN_2006 GBV_ILN_2007 GBV_ILN_2008 GBV_ILN_2009 GBV_ILN_2010 GBV_ILN_2011 GBV_ILN_2014 GBV_ILN_2015 GBV_ILN_2020 GBV_ILN_2021 GBV_ILN_2025 GBV_ILN_2026 GBV_ILN_2027 GBV_ILN_2031 GBV_ILN_2034 GBV_ILN_2037 GBV_ILN_2038 GBV_ILN_2039 GBV_ILN_2044 GBV_ILN_2048 GBV_ILN_2049 GBV_ILN_2050 GBV_ILN_2055 GBV_ILN_2057 GBV_ILN_2059 GBV_ILN_2061 GBV_ILN_2064 GBV_ILN_2065 GBV_ILN_2068 GBV_ILN_2070 GBV_ILN_2086 GBV_ILN_2088 GBV_ILN_2093 GBV_ILN_2106 GBV_ILN_2107 GBV_ILN_2108 GBV_ILN_2110 GBV_ILN_2111 GBV_ILN_2112 GBV_ILN_2113 GBV_ILN_2116 GBV_ILN_2118 GBV_ILN_2119 GBV_ILN_2122 GBV_ILN_2129 GBV_ILN_2143 GBV_ILN_2144 GBV_ILN_2147 GBV_ILN_2148 GBV_ILN_2152 GBV_ILN_2153 GBV_ILN_2188 GBV_ILN_2190 GBV_ILN_2232 GBV_ILN_2336 GBV_ILN_2446 GBV_ILN_2470 GBV_ILN_2472 GBV_ILN_2507 GBV_ILN_2522 GBV_ILN_2548 GBV_ILN_4035 GBV_ILN_4037 GBV_ILN_4046 GBV_ILN_4112 GBV_ILN_4125 GBV_ILN_4242 GBV_ILN_4246 GBV_ILN_4249 GBV_ILN_4251 GBV_ILN_4305 GBV_ILN_4306 GBV_ILN_4307 GBV_ILN_4313 GBV_ILN_4322 GBV_ILN_4323 GBV_ILN_4324 GBV_ILN_4325 GBV_ILN_4326 GBV_ILN_4328 GBV_ILN_4333 GBV_ILN_4334 GBV_ILN_4335 GBV_ILN_4336 GBV_ILN_4338 GBV_ILN_4393 GBV_ILN_4700 AR 38 2019 2 09 05 447-453 |
allfieldsSound |
10.1007/s00345-019-02801-y doi (DE-627)SPR004327063 (SPR)s00345-019-02801-y-e DE-627 ger DE-627 rakwb eng Rassweiler-Seyfried, Marie-Claire verfasserin (orcid)0000-0003-1670-4072 aut iPad-assisted percutaneous nephrolithotomy (PCNL): a matched pair analysis compared to standard PCNL 2019 Text txt rdacontent Computermedien c rdamedia Online-Ressource cr rdacarrier © Springer-Verlag GmbH Germany, part of Springer Nature 2019 Purpose To compare iPad-assisted (Apple Inc., Cupertino, USA) percutaneous access to the kidney to the standard puncturing technique for percutaneous nephrolithotomy (PCNL). Methods For the iPad-assisted PCNL, a computed tomography is performed prior to surgery, using fiducial radiopaque markers. The important anatomical structures (i.e. kidney, stones) are segmented using specific software enabling the superimposition of images semi-transparently on the iPad by marker-based navigation. Twenty-two patients underwent an iPad-assisted percutaneous puncture of the kidney for PCNL. Twenty-two patients of the clinical database from the Urological Department SLK Hospital Heilbronn, who underwent the standard puncturing technique, were matched to these patients. Matching criteria were age, gender, stone volume, body mass index, stone site and the absence of anatomical variation. Puncture time, radiation exposure and number of attempts for a successful puncture were evaluated. All procedures were performed by two experienced urologists. The standard puncturing method consisted of a combination of ultrasound and fluoroscopy guidance. Chi-square and t test were used to ensure that there was no difference in the matching criteria between the groups. To compare the two methods, U test, Kruskal–Wallis and Chi-square test were used. Results Examination of radiation exposure showed a significant difference between the two groups in favour of the standard puncturing method (p < 0.01) and puncture time (p = 0.01). However, there was no significant difference in puncturing attempts (p = 0.45). Conclusion The iPad-assisted navigation, with the objective being to puncture the renal collecting system, represents a new technique (IDEAL criteria 2b), which proved to be applicable in clinical practice, but still has potential for technical improvement. Navigation (dpeaa)DE-He213 Percutaneous nephrolithotomy (dpeaa)DE-He213 Urolithiasis (dpeaa)DE-He213 Virtual reality (dpeaa)DE-He213 Augmented reality (dpeaa)DE-He213 Rassweiler, J. J. aut Weiss, C. aut Müller, M. aut Meinzer, H. P. aut Maier-Hein, L. aut Klein, J. T. aut Enthalten in World journal of urology Berlin : Springer, 1983 38(2019), 2 vom: 09. Mai, Seite 447-453 (DE-627)254910874 (DE-600)1463303-6 1433-8726 nnns volume:38 year:2019 number:2 day:09 month:05 pages:447-453 https://dx.doi.org/10.1007/s00345-019-02801-y lizenzpflichtig Volltext GBV_USEFLAG_A SYSFLAG_A GBV_SPRINGER SSG-OLC-PHA GBV_ILN_11 GBV_ILN_20 GBV_ILN_22 GBV_ILN_23 GBV_ILN_24 GBV_ILN_31 GBV_ILN_32 GBV_ILN_39 GBV_ILN_40 GBV_ILN_60 GBV_ILN_62 GBV_ILN_63 GBV_ILN_69 GBV_ILN_70 GBV_ILN_73 GBV_ILN_74 GBV_ILN_90 GBV_ILN_95 GBV_ILN_100 GBV_ILN_101 GBV_ILN_105 GBV_ILN_110 GBV_ILN_120 GBV_ILN_138 GBV_ILN_150 GBV_ILN_151 GBV_ILN_152 GBV_ILN_161 GBV_ILN_170 GBV_ILN_171 GBV_ILN_187 GBV_ILN_213 GBV_ILN_224 GBV_ILN_230 GBV_ILN_250 GBV_ILN_267 GBV_ILN_281 GBV_ILN_285 GBV_ILN_293 GBV_ILN_370 GBV_ILN_602 GBV_ILN_636 GBV_ILN_702 GBV_ILN_711 GBV_ILN_2001 GBV_ILN_2003 GBV_ILN_2004 GBV_ILN_2005 GBV_ILN_2006 GBV_ILN_2007 GBV_ILN_2008 GBV_ILN_2009 GBV_ILN_2010 GBV_ILN_2011 GBV_ILN_2014 GBV_ILN_2015 GBV_ILN_2020 GBV_ILN_2021 GBV_ILN_2025 GBV_ILN_2026 GBV_ILN_2027 GBV_ILN_2031 GBV_ILN_2034 GBV_ILN_2037 GBV_ILN_2038 GBV_ILN_2039 GBV_ILN_2044 GBV_ILN_2048 GBV_ILN_2049 GBV_ILN_2050 GBV_ILN_2055 GBV_ILN_2057 GBV_ILN_2059 GBV_ILN_2061 GBV_ILN_2064 GBV_ILN_2065 GBV_ILN_2068 GBV_ILN_2070 GBV_ILN_2086 GBV_ILN_2088 GBV_ILN_2093 GBV_ILN_2106 GBV_ILN_2107 GBV_ILN_2108 GBV_ILN_2110 GBV_ILN_2111 GBV_ILN_2112 GBV_ILN_2113 GBV_ILN_2116 GBV_ILN_2118 GBV_ILN_2119 GBV_ILN_2122 GBV_ILN_2129 GBV_ILN_2143 GBV_ILN_2144 GBV_ILN_2147 GBV_ILN_2148 GBV_ILN_2152 GBV_ILN_2153 GBV_ILN_2188 GBV_ILN_2190 GBV_ILN_2232 GBV_ILN_2336 GBV_ILN_2446 GBV_ILN_2470 GBV_ILN_2472 GBV_ILN_2507 GBV_ILN_2522 GBV_ILN_2548 GBV_ILN_4035 GBV_ILN_4037 GBV_ILN_4046 GBV_ILN_4112 GBV_ILN_4125 GBV_ILN_4242 GBV_ILN_4246 GBV_ILN_4249 GBV_ILN_4251 GBV_ILN_4305 GBV_ILN_4306 GBV_ILN_4307 GBV_ILN_4313 GBV_ILN_4322 GBV_ILN_4323 GBV_ILN_4324 GBV_ILN_4325 GBV_ILN_4326 GBV_ILN_4328 GBV_ILN_4333 GBV_ILN_4334 GBV_ILN_4335 GBV_ILN_4336 GBV_ILN_4338 GBV_ILN_4393 GBV_ILN_4700 AR 38 2019 2 09 05 447-453 |
language |
English |
source |
Enthalten in World journal of urology 38(2019), 2 vom: 09. Mai, Seite 447-453 volume:38 year:2019 number:2 day:09 month:05 pages:447-453 |
sourceStr |
Enthalten in World journal of urology 38(2019), 2 vom: 09. Mai, Seite 447-453 volume:38 year:2019 number:2 day:09 month:05 pages:447-453 |
format_phy_str_mv |
Article |
institution |
findex.gbv.de |
topic_facet |
Navigation Percutaneous nephrolithotomy Urolithiasis Virtual reality Augmented reality |
isfreeaccess_bool |
false |
container_title |
World journal of urology |
authorswithroles_txt_mv |
Rassweiler-Seyfried, Marie-Claire @@aut@@ Rassweiler, J. J. @@aut@@ Weiss, C. @@aut@@ Müller, M. @@aut@@ Meinzer, H. P. @@aut@@ Maier-Hein, L. @@aut@@ Klein, J. T. @@aut@@ |
publishDateDaySort_date |
2019-05-09T00:00:00Z |
hierarchy_top_id |
254910874 |
id |
SPR004327063 |
language_de |
englisch |
fullrecord |
<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim"><record><leader>01000caa a22002652 4500</leader><controlfield tag="001">SPR004327063</controlfield><controlfield tag="003">DE-627</controlfield><controlfield tag="005">20230519120707.0</controlfield><controlfield tag="007">cr uuu---uuuuu</controlfield><controlfield tag="008">201001s2019 xx |||||o 00| ||eng c</controlfield><datafield tag="024" ind1="7" ind2=" "><subfield code="a">10.1007/s00345-019-02801-y</subfield><subfield code="2">doi</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-627)SPR004327063</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(SPR)s00345-019-02801-y-e</subfield></datafield><datafield tag="040" ind1=" " ind2=" "><subfield code="a">DE-627</subfield><subfield code="b">ger</subfield><subfield code="c">DE-627</subfield><subfield code="e">rakwb</subfield></datafield><datafield tag="041" ind1=" " ind2=" "><subfield code="a">eng</subfield></datafield><datafield tag="100" ind1="1" ind2=" "><subfield code="a">Rassweiler-Seyfried, Marie-Claire</subfield><subfield code="e">verfasserin</subfield><subfield code="0">(orcid)0000-0003-1670-4072</subfield><subfield code="4">aut</subfield></datafield><datafield tag="245" ind1="1" ind2="0"><subfield code="a">iPad-assisted percutaneous nephrolithotomy (PCNL): a matched pair analysis compared to standard PCNL</subfield></datafield><datafield tag="264" ind1=" " ind2="1"><subfield code="c">2019</subfield></datafield><datafield tag="336" ind1=" " ind2=" "><subfield code="a">Text</subfield><subfield code="b">txt</subfield><subfield code="2">rdacontent</subfield></datafield><datafield tag="337" ind1=" " ind2=" "><subfield code="a">Computermedien</subfield><subfield code="b">c</subfield><subfield code="2">rdamedia</subfield></datafield><datafield tag="338" ind1=" " ind2=" "><subfield code="a">Online-Ressource</subfield><subfield code="b">cr</subfield><subfield code="2">rdacarrier</subfield></datafield><datafield tag="500" ind1=" " ind2=" "><subfield code="a">© Springer-Verlag GmbH Germany, part of Springer Nature 2019</subfield></datafield><datafield tag="520" ind1=" " ind2=" "><subfield code="a">Purpose To compare iPad-assisted (Apple Inc., Cupertino, USA) percutaneous access to the kidney to the standard puncturing technique for percutaneous nephrolithotomy (PCNL). Methods For the iPad-assisted PCNL, a computed tomography is performed prior to surgery, using fiducial radiopaque markers. The important anatomical structures (i.e. kidney, stones) are segmented using specific software enabling the superimposition of images semi-transparently on the iPad by marker-based navigation. Twenty-two patients underwent an iPad-assisted percutaneous puncture of the kidney for PCNL. Twenty-two patients of the clinical database from the Urological Department SLK Hospital Heilbronn, who underwent the standard puncturing technique, were matched to these patients. Matching criteria were age, gender, stone volume, body mass index, stone site and the absence of anatomical variation. Puncture time, radiation exposure and number of attempts for a successful puncture were evaluated. All procedures were performed by two experienced urologists. The standard puncturing method consisted of a combination of ultrasound and fluoroscopy guidance. Chi-square and t test were used to ensure that there was no difference in the matching criteria between the groups. To compare the two methods, U test, Kruskal–Wallis and Chi-square test were used. Results Examination of radiation exposure showed a significant difference between the two groups in favour of the standard puncturing method (p < 0.01) and puncture time (p = 0.01). However, there was no significant difference in puncturing attempts (p = 0.45). Conclusion The iPad-assisted navigation, with the objective being to puncture the renal collecting system, represents a new technique (IDEAL criteria 2b), which proved to be applicable in clinical practice, but still has potential for technical improvement.</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Navigation</subfield><subfield code="7">(dpeaa)DE-He213</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Percutaneous nephrolithotomy</subfield><subfield code="7">(dpeaa)DE-He213</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Urolithiasis</subfield><subfield code="7">(dpeaa)DE-He213</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Virtual reality</subfield><subfield code="7">(dpeaa)DE-He213</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Augmented reality</subfield><subfield code="7">(dpeaa)DE-He213</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Rassweiler, J. J.</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Weiss, C.</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Müller, M.</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Meinzer, H. P.</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Maier-Hein, L.</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Klein, J. T.</subfield><subfield code="4">aut</subfield></datafield><datafield tag="773" ind1="0" ind2="8"><subfield code="i">Enthalten in</subfield><subfield code="t">World journal of urology</subfield><subfield code="d">Berlin : Springer, 1983</subfield><subfield code="g">38(2019), 2 vom: 09. Mai, Seite 447-453</subfield><subfield code="w">(DE-627)254910874</subfield><subfield code="w">(DE-600)1463303-6</subfield><subfield code="x">1433-8726</subfield><subfield code="7">nnns</subfield></datafield><datafield tag="773" ind1="1" ind2="8"><subfield code="g">volume:38</subfield><subfield code="g">year:2019</subfield><subfield code="g">number:2</subfield><subfield code="g">day:09</subfield><subfield code="g">month:05</subfield><subfield code="g">pages:447-453</subfield></datafield><datafield tag="856" ind1="4" ind2="0"><subfield code="u">https://dx.doi.org/10.1007/s00345-019-02801-y</subfield><subfield code="z">lizenzpflichtig</subfield><subfield code="3">Volltext</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_USEFLAG_A</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">SYSFLAG_A</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_SPRINGER</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">SSG-OLC-PHA</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_11</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_20</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_22</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_23</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_24</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_31</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_32</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_39</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_40</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_60</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_62</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_63</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_69</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_70</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_73</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_74</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_90</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_95</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_100</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_101</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_105</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_110</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_120</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_138</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_150</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_151</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_152</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_161</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_170</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_171</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_187</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_213</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_224</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_230</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_250</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_267</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_281</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_285</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_293</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_370</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_602</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_636</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_702</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_711</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2001</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2003</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2004</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2005</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2006</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2007</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2008</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2009</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2010</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2011</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2014</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2015</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2020</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2021</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2025</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2026</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2027</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2031</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2034</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2037</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2038</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2039</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2044</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2048</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2049</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2050</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2055</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2057</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2059</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2061</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2064</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2065</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2068</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2070</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2086</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2088</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2093</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2106</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2107</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2108</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2110</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2111</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2112</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2113</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2116</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2118</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2119</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2122</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2129</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2143</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2144</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2147</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2148</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2152</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2153</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2188</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2190</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2232</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2336</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2446</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2470</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2472</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2507</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2522</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2548</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4035</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4037</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4046</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4112</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4125</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4242</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4246</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4249</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4251</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4305</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4306</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4307</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4313</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4322</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4323</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4324</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4325</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4326</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4328</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4333</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4334</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4335</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4336</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4338</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4393</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4700</subfield></datafield><datafield tag="951" ind1=" " ind2=" "><subfield code="a">AR</subfield></datafield><datafield tag="952" ind1=" " ind2=" "><subfield code="d">38</subfield><subfield code="j">2019</subfield><subfield code="e">2</subfield><subfield code="b">09</subfield><subfield code="c">05</subfield><subfield code="h">447-453</subfield></datafield></record></collection>
|
author |
Rassweiler-Seyfried, Marie-Claire |
spellingShingle |
Rassweiler-Seyfried, Marie-Claire misc Navigation misc Percutaneous nephrolithotomy misc Urolithiasis misc Virtual reality misc Augmented reality iPad-assisted percutaneous nephrolithotomy (PCNL): a matched pair analysis compared to standard PCNL |
authorStr |
Rassweiler-Seyfried, Marie-Claire |
ppnlink_with_tag_str_mv |
@@773@@(DE-627)254910874 |
format |
electronic Article |
delete_txt_mv |
keep |
author_role |
aut aut aut aut aut aut aut |
collection |
springer |
remote_str |
true |
illustrated |
Not Illustrated |
issn |
1433-8726 |
topic_title |
iPad-assisted percutaneous nephrolithotomy (PCNL): a matched pair analysis compared to standard PCNL Navigation (dpeaa)DE-He213 Percutaneous nephrolithotomy (dpeaa)DE-He213 Urolithiasis (dpeaa)DE-He213 Virtual reality (dpeaa)DE-He213 Augmented reality (dpeaa)DE-He213 |
topic |
misc Navigation misc Percutaneous nephrolithotomy misc Urolithiasis misc Virtual reality misc Augmented reality |
topic_unstemmed |
misc Navigation misc Percutaneous nephrolithotomy misc Urolithiasis misc Virtual reality misc Augmented reality |
topic_browse |
misc Navigation misc Percutaneous nephrolithotomy misc Urolithiasis misc Virtual reality misc Augmented reality |
format_facet |
Elektronische Aufsätze Aufsätze Elektronische Ressource |
format_main_str_mv |
Text Zeitschrift/Artikel |
carriertype_str_mv |
cr |
hierarchy_parent_title |
World journal of urology |
hierarchy_parent_id |
254910874 |
hierarchy_top_title |
World journal of urology |
isfreeaccess_txt |
false |
familylinks_str_mv |
(DE-627)254910874 (DE-600)1463303-6 |
title |
iPad-assisted percutaneous nephrolithotomy (PCNL): a matched pair analysis compared to standard PCNL |
ctrlnum |
(DE-627)SPR004327063 (SPR)s00345-019-02801-y-e |
title_full |
iPad-assisted percutaneous nephrolithotomy (PCNL): a matched pair analysis compared to standard PCNL |
author_sort |
Rassweiler-Seyfried, Marie-Claire |
journal |
World journal of urology |
journalStr |
World journal of urology |
lang_code |
eng |
isOA_bool |
false |
recordtype |
marc |
publishDateSort |
2019 |
contenttype_str_mv |
txt |
container_start_page |
447 |
author_browse |
Rassweiler-Seyfried, Marie-Claire Rassweiler, J. J. Weiss, C. Müller, M. Meinzer, H. P. Maier-Hein, L. Klein, J. T. |
container_volume |
38 |
format_se |
Elektronische Aufsätze |
author-letter |
Rassweiler-Seyfried, Marie-Claire |
doi_str_mv |
10.1007/s00345-019-02801-y |
normlink |
(ORCID)0000-0003-1670-4072 |
normlink_prefix_str_mv |
(orcid)0000-0003-1670-4072 |
title_sort |
ipad-assisted percutaneous nephrolithotomy (pcnl): a matched pair analysis compared to standard pcnl |
title_auth |
iPad-assisted percutaneous nephrolithotomy (PCNL): a matched pair analysis compared to standard PCNL |
abstract |
Purpose To compare iPad-assisted (Apple Inc., Cupertino, USA) percutaneous access to the kidney to the standard puncturing technique for percutaneous nephrolithotomy (PCNL). Methods For the iPad-assisted PCNL, a computed tomography is performed prior to surgery, using fiducial radiopaque markers. The important anatomical structures (i.e. kidney, stones) are segmented using specific software enabling the superimposition of images semi-transparently on the iPad by marker-based navigation. Twenty-two patients underwent an iPad-assisted percutaneous puncture of the kidney for PCNL. Twenty-two patients of the clinical database from the Urological Department SLK Hospital Heilbronn, who underwent the standard puncturing technique, were matched to these patients. Matching criteria were age, gender, stone volume, body mass index, stone site and the absence of anatomical variation. Puncture time, radiation exposure and number of attempts for a successful puncture were evaluated. All procedures were performed by two experienced urologists. The standard puncturing method consisted of a combination of ultrasound and fluoroscopy guidance. Chi-square and t test were used to ensure that there was no difference in the matching criteria between the groups. To compare the two methods, U test, Kruskal–Wallis and Chi-square test were used. Results Examination of radiation exposure showed a significant difference between the two groups in favour of the standard puncturing method (p < 0.01) and puncture time (p = 0.01). However, there was no significant difference in puncturing attempts (p = 0.45). Conclusion The iPad-assisted navigation, with the objective being to puncture the renal collecting system, represents a new technique (IDEAL criteria 2b), which proved to be applicable in clinical practice, but still has potential for technical improvement. © Springer-Verlag GmbH Germany, part of Springer Nature 2019 |
abstractGer |
Purpose To compare iPad-assisted (Apple Inc., Cupertino, USA) percutaneous access to the kidney to the standard puncturing technique for percutaneous nephrolithotomy (PCNL). Methods For the iPad-assisted PCNL, a computed tomography is performed prior to surgery, using fiducial radiopaque markers. The important anatomical structures (i.e. kidney, stones) are segmented using specific software enabling the superimposition of images semi-transparently on the iPad by marker-based navigation. Twenty-two patients underwent an iPad-assisted percutaneous puncture of the kidney for PCNL. Twenty-two patients of the clinical database from the Urological Department SLK Hospital Heilbronn, who underwent the standard puncturing technique, were matched to these patients. Matching criteria were age, gender, stone volume, body mass index, stone site and the absence of anatomical variation. Puncture time, radiation exposure and number of attempts for a successful puncture were evaluated. All procedures were performed by two experienced urologists. The standard puncturing method consisted of a combination of ultrasound and fluoroscopy guidance. Chi-square and t test were used to ensure that there was no difference in the matching criteria between the groups. To compare the two methods, U test, Kruskal–Wallis and Chi-square test were used. Results Examination of radiation exposure showed a significant difference between the two groups in favour of the standard puncturing method (p < 0.01) and puncture time (p = 0.01). However, there was no significant difference in puncturing attempts (p = 0.45). Conclusion The iPad-assisted navigation, with the objective being to puncture the renal collecting system, represents a new technique (IDEAL criteria 2b), which proved to be applicable in clinical practice, but still has potential for technical improvement. © Springer-Verlag GmbH Germany, part of Springer Nature 2019 |
abstract_unstemmed |
Purpose To compare iPad-assisted (Apple Inc., Cupertino, USA) percutaneous access to the kidney to the standard puncturing technique for percutaneous nephrolithotomy (PCNL). Methods For the iPad-assisted PCNL, a computed tomography is performed prior to surgery, using fiducial radiopaque markers. The important anatomical structures (i.e. kidney, stones) are segmented using specific software enabling the superimposition of images semi-transparently on the iPad by marker-based navigation. Twenty-two patients underwent an iPad-assisted percutaneous puncture of the kidney for PCNL. Twenty-two patients of the clinical database from the Urological Department SLK Hospital Heilbronn, who underwent the standard puncturing technique, were matched to these patients. Matching criteria were age, gender, stone volume, body mass index, stone site and the absence of anatomical variation. Puncture time, radiation exposure and number of attempts for a successful puncture were evaluated. All procedures were performed by two experienced urologists. The standard puncturing method consisted of a combination of ultrasound and fluoroscopy guidance. Chi-square and t test were used to ensure that there was no difference in the matching criteria between the groups. To compare the two methods, U test, Kruskal–Wallis and Chi-square test were used. Results Examination of radiation exposure showed a significant difference between the two groups in favour of the standard puncturing method (p < 0.01) and puncture time (p = 0.01). However, there was no significant difference in puncturing attempts (p = 0.45). Conclusion The iPad-assisted navigation, with the objective being to puncture the renal collecting system, represents a new technique (IDEAL criteria 2b), which proved to be applicable in clinical practice, but still has potential for technical improvement. © Springer-Verlag GmbH Germany, part of Springer Nature 2019 |
collection_details |
GBV_USEFLAG_A SYSFLAG_A GBV_SPRINGER SSG-OLC-PHA GBV_ILN_11 GBV_ILN_20 GBV_ILN_22 GBV_ILN_23 GBV_ILN_24 GBV_ILN_31 GBV_ILN_32 GBV_ILN_39 GBV_ILN_40 GBV_ILN_60 GBV_ILN_62 GBV_ILN_63 GBV_ILN_69 GBV_ILN_70 GBV_ILN_73 GBV_ILN_74 GBV_ILN_90 GBV_ILN_95 GBV_ILN_100 GBV_ILN_101 GBV_ILN_105 GBV_ILN_110 GBV_ILN_120 GBV_ILN_138 GBV_ILN_150 GBV_ILN_151 GBV_ILN_152 GBV_ILN_161 GBV_ILN_170 GBV_ILN_171 GBV_ILN_187 GBV_ILN_213 GBV_ILN_224 GBV_ILN_230 GBV_ILN_250 GBV_ILN_267 GBV_ILN_281 GBV_ILN_285 GBV_ILN_293 GBV_ILN_370 GBV_ILN_602 GBV_ILN_636 GBV_ILN_702 GBV_ILN_711 GBV_ILN_2001 GBV_ILN_2003 GBV_ILN_2004 GBV_ILN_2005 GBV_ILN_2006 GBV_ILN_2007 GBV_ILN_2008 GBV_ILN_2009 GBV_ILN_2010 GBV_ILN_2011 GBV_ILN_2014 GBV_ILN_2015 GBV_ILN_2020 GBV_ILN_2021 GBV_ILN_2025 GBV_ILN_2026 GBV_ILN_2027 GBV_ILN_2031 GBV_ILN_2034 GBV_ILN_2037 GBV_ILN_2038 GBV_ILN_2039 GBV_ILN_2044 GBV_ILN_2048 GBV_ILN_2049 GBV_ILN_2050 GBV_ILN_2055 GBV_ILN_2057 GBV_ILN_2059 GBV_ILN_2061 GBV_ILN_2064 GBV_ILN_2065 GBV_ILN_2068 GBV_ILN_2070 GBV_ILN_2086 GBV_ILN_2088 GBV_ILN_2093 GBV_ILN_2106 GBV_ILN_2107 GBV_ILN_2108 GBV_ILN_2110 GBV_ILN_2111 GBV_ILN_2112 GBV_ILN_2113 GBV_ILN_2116 GBV_ILN_2118 GBV_ILN_2119 GBV_ILN_2122 GBV_ILN_2129 GBV_ILN_2143 GBV_ILN_2144 GBV_ILN_2147 GBV_ILN_2148 GBV_ILN_2152 GBV_ILN_2153 GBV_ILN_2188 GBV_ILN_2190 GBV_ILN_2232 GBV_ILN_2336 GBV_ILN_2446 GBV_ILN_2470 GBV_ILN_2472 GBV_ILN_2507 GBV_ILN_2522 GBV_ILN_2548 GBV_ILN_4035 GBV_ILN_4037 GBV_ILN_4046 GBV_ILN_4112 GBV_ILN_4125 GBV_ILN_4242 GBV_ILN_4246 GBV_ILN_4249 GBV_ILN_4251 GBV_ILN_4305 GBV_ILN_4306 GBV_ILN_4307 GBV_ILN_4313 GBV_ILN_4322 GBV_ILN_4323 GBV_ILN_4324 GBV_ILN_4325 GBV_ILN_4326 GBV_ILN_4328 GBV_ILN_4333 GBV_ILN_4334 GBV_ILN_4335 GBV_ILN_4336 GBV_ILN_4338 GBV_ILN_4393 GBV_ILN_4700 |
container_issue |
2 |
title_short |
iPad-assisted percutaneous nephrolithotomy (PCNL): a matched pair analysis compared to standard PCNL |
url |
https://dx.doi.org/10.1007/s00345-019-02801-y |
remote_bool |
true |
author2 |
Rassweiler, J. J. Weiss, C. Müller, M. Meinzer, H. P. Maier-Hein, L. Klein, J. T. |
author2Str |
Rassweiler, J. J. Weiss, C. Müller, M. Meinzer, H. P. Maier-Hein, L. Klein, J. T. |
ppnlink |
254910874 |
mediatype_str_mv |
c |
isOA_txt |
false |
hochschulschrift_bool |
false |
doi_str |
10.1007/s00345-019-02801-y |
up_date |
2024-07-04T00:42:05.046Z |
_version_ |
1803607054794883072 |
fullrecord_marcxml |
<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim"><record><leader>01000caa a22002652 4500</leader><controlfield tag="001">SPR004327063</controlfield><controlfield tag="003">DE-627</controlfield><controlfield tag="005">20230519120707.0</controlfield><controlfield tag="007">cr uuu---uuuuu</controlfield><controlfield tag="008">201001s2019 xx |||||o 00| ||eng c</controlfield><datafield tag="024" ind1="7" ind2=" "><subfield code="a">10.1007/s00345-019-02801-y</subfield><subfield code="2">doi</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-627)SPR004327063</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(SPR)s00345-019-02801-y-e</subfield></datafield><datafield tag="040" ind1=" " ind2=" "><subfield code="a">DE-627</subfield><subfield code="b">ger</subfield><subfield code="c">DE-627</subfield><subfield code="e">rakwb</subfield></datafield><datafield tag="041" ind1=" " ind2=" "><subfield code="a">eng</subfield></datafield><datafield tag="100" ind1="1" ind2=" "><subfield code="a">Rassweiler-Seyfried, Marie-Claire</subfield><subfield code="e">verfasserin</subfield><subfield code="0">(orcid)0000-0003-1670-4072</subfield><subfield code="4">aut</subfield></datafield><datafield tag="245" ind1="1" ind2="0"><subfield code="a">iPad-assisted percutaneous nephrolithotomy (PCNL): a matched pair analysis compared to standard PCNL</subfield></datafield><datafield tag="264" ind1=" " ind2="1"><subfield code="c">2019</subfield></datafield><datafield tag="336" ind1=" " ind2=" "><subfield code="a">Text</subfield><subfield code="b">txt</subfield><subfield code="2">rdacontent</subfield></datafield><datafield tag="337" ind1=" " ind2=" "><subfield code="a">Computermedien</subfield><subfield code="b">c</subfield><subfield code="2">rdamedia</subfield></datafield><datafield tag="338" ind1=" " ind2=" "><subfield code="a">Online-Ressource</subfield><subfield code="b">cr</subfield><subfield code="2">rdacarrier</subfield></datafield><datafield tag="500" ind1=" " ind2=" "><subfield code="a">© Springer-Verlag GmbH Germany, part of Springer Nature 2019</subfield></datafield><datafield tag="520" ind1=" " ind2=" "><subfield code="a">Purpose To compare iPad-assisted (Apple Inc., Cupertino, USA) percutaneous access to the kidney to the standard puncturing technique for percutaneous nephrolithotomy (PCNL). Methods For the iPad-assisted PCNL, a computed tomography is performed prior to surgery, using fiducial radiopaque markers. The important anatomical structures (i.e. kidney, stones) are segmented using specific software enabling the superimposition of images semi-transparently on the iPad by marker-based navigation. Twenty-two patients underwent an iPad-assisted percutaneous puncture of the kidney for PCNL. Twenty-two patients of the clinical database from the Urological Department SLK Hospital Heilbronn, who underwent the standard puncturing technique, were matched to these patients. Matching criteria were age, gender, stone volume, body mass index, stone site and the absence of anatomical variation. Puncture time, radiation exposure and number of attempts for a successful puncture were evaluated. All procedures were performed by two experienced urologists. The standard puncturing method consisted of a combination of ultrasound and fluoroscopy guidance. Chi-square and t test were used to ensure that there was no difference in the matching criteria between the groups. To compare the two methods, U test, Kruskal–Wallis and Chi-square test were used. Results Examination of radiation exposure showed a significant difference between the two groups in favour of the standard puncturing method (p < 0.01) and puncture time (p = 0.01). However, there was no significant difference in puncturing attempts (p = 0.45). Conclusion The iPad-assisted navigation, with the objective being to puncture the renal collecting system, represents a new technique (IDEAL criteria 2b), which proved to be applicable in clinical practice, but still has potential for technical improvement.</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Navigation</subfield><subfield code="7">(dpeaa)DE-He213</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Percutaneous nephrolithotomy</subfield><subfield code="7">(dpeaa)DE-He213</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Urolithiasis</subfield><subfield code="7">(dpeaa)DE-He213</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Virtual reality</subfield><subfield code="7">(dpeaa)DE-He213</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Augmented reality</subfield><subfield code="7">(dpeaa)DE-He213</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Rassweiler, J. J.</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Weiss, C.</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Müller, M.</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Meinzer, H. P.</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Maier-Hein, L.</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Klein, J. T.</subfield><subfield code="4">aut</subfield></datafield><datafield tag="773" ind1="0" ind2="8"><subfield code="i">Enthalten in</subfield><subfield code="t">World journal of urology</subfield><subfield code="d">Berlin : Springer, 1983</subfield><subfield code="g">38(2019), 2 vom: 09. Mai, Seite 447-453</subfield><subfield code="w">(DE-627)254910874</subfield><subfield code="w">(DE-600)1463303-6</subfield><subfield code="x">1433-8726</subfield><subfield code="7">nnns</subfield></datafield><datafield tag="773" ind1="1" ind2="8"><subfield code="g">volume:38</subfield><subfield code="g">year:2019</subfield><subfield code="g">number:2</subfield><subfield code="g">day:09</subfield><subfield code="g">month:05</subfield><subfield code="g">pages:447-453</subfield></datafield><datafield tag="856" ind1="4" ind2="0"><subfield code="u">https://dx.doi.org/10.1007/s00345-019-02801-y</subfield><subfield code="z">lizenzpflichtig</subfield><subfield code="3">Volltext</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_USEFLAG_A</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">SYSFLAG_A</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_SPRINGER</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">SSG-OLC-PHA</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_11</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_20</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_22</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_23</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_24</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_31</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_32</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_39</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_40</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_60</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_62</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_63</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_69</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_70</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_73</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_74</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_90</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_95</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_100</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_101</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_105</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_110</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_120</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_138</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_150</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_151</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_152</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_161</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_170</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_171</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_187</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_213</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_224</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_230</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_250</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_267</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_281</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_285</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_293</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_370</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_602</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_636</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_702</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_711</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2001</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2003</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2004</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2005</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2006</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2007</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2008</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2009</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2010</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2011</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2014</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2015</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2020</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2021</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2025</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2026</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2027</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2031</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2034</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2037</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2038</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2039</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2044</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2048</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2049</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2050</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2055</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2057</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2059</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2061</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2064</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2065</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2068</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2070</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2086</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2088</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2093</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2106</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2107</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2108</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2110</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2111</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2112</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2113</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2116</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2118</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2119</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2122</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2129</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2143</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2144</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2147</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2148</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2152</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2153</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2188</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2190</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2232</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2336</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2446</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2470</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2472</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2507</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2522</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2548</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4035</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4037</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4046</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4112</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4125</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4242</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4246</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4249</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4251</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4305</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4306</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4307</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4313</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4322</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4323</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4324</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4325</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4326</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4328</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4333</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4334</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4335</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4336</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4338</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4393</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4700</subfield></datafield><datafield tag="951" ind1=" " ind2=" "><subfield code="a">AR</subfield></datafield><datafield tag="952" ind1=" " ind2=" "><subfield code="d">38</subfield><subfield code="j">2019</subfield><subfield code="e">2</subfield><subfield code="b">09</subfield><subfield code="c">05</subfield><subfield code="h">447-453</subfield></datafield></record></collection>
|
score |
7.4020357 |