Transcatheter Edwards Sapien XT valve in valve implantation in degenerated aortic bioprostheses via transfemoral access
Objectives Surgical treatment of degenerated aortic bioprostheses is associated with an increased risk of morbidity and mortality, especially in elderly patients with significant co-morbidities. Therefore, transcatheter aortic valve implantation (TAVI) performed as valve in valve technique appears a...
Ausführliche Beschreibung
Autor*in: |
Greif, Martin [verfasserIn] Lange, Philipp [verfasserIn] Mair, Helmut [verfasserIn] Becker, Christoph [verfasserIn] Schmitz, Christoph [verfasserIn] Steinbeck, Gerhard [verfasserIn] Kupatt, Christian [verfasserIn] |
---|
Format: |
E-Artikel |
---|---|
Sprache: |
Englisch |
Erschienen: |
2012 |
---|
Schlagwörter: |
---|
Übergeordnetes Werk: |
Enthalten in: Zeitschrift für Kardiologie - Darmstadt : Steinkopff, 1997, 101(2012), 12 vom: 23. Juni, Seite 993-1001 |
---|---|
Übergeordnetes Werk: |
volume:101 ; year:2012 ; number:12 ; day:23 ; month:06 ; pages:993-1001 |
Links: |
---|
DOI / URN: |
10.1007/s00392-012-0488-3 |
---|
Katalog-ID: |
SPR004805895 |
---|
LEADER | 01000caa a22002652 4500 | ||
---|---|---|---|
001 | SPR004805895 | ||
003 | DE-627 | ||
005 | 20230519112358.0 | ||
007 | cr uuu---uuuuu | ||
008 | 201001s2012 xx |||||o 00| ||eng c | ||
024 | 7 | |a 10.1007/s00392-012-0488-3 |2 doi | |
035 | |a (DE-627)SPR004805895 | ||
035 | |a (SPR)s00392-012-0488-3-e | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
082 | 0 | 4 | |a 610 |q ASE |
082 | 0 | 4 | |a 610 |q ASE |
084 | |a 44.67 |2 bkl | ||
084 | |a 44.85 |2 bkl | ||
100 | 1 | |a Greif, Martin |e verfasserin |4 aut | |
245 | 1 | 0 | |a Transcatheter Edwards Sapien XT valve in valve implantation in degenerated aortic bioprostheses via transfemoral access |
264 | 1 | |c 2012 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a Computermedien |b c |2 rdamedia | ||
338 | |a Online-Ressource |b cr |2 rdacarrier | ||
520 | |a Objectives Surgical treatment of degenerated aortic bioprostheses is associated with an increased risk of morbidity and mortality, especially in elderly patients with significant co-morbidities. Therefore, transcatheter aortic valve implantation (TAVI) performed as valve in valve technique appears as an attractive alternative treatment option. We report of a case series of seven patients with dysfunctional bioprosthetic aortic heart valves who have been treated with TAVI via transfemoral access. Methods and results Valve in valve implantation using the Edwards Sapien XT bioprostheses (Edwards Lifesciences LLC, Irvine, CA, USA) was performed in eight patients (3 men, 5 women, mean age 85.3 ± 6.1 years) with a high operative risk (logistic euroSCORE 27.2 ± 7.3). Six patients underwent TAVI because of high grade stenosis of the aortic bioprostheses, whereas two patients presented with high grade regurgitation. All patients suffered at least from NYHA class III dyspnea during admission. TAVI was successfully performed via transfemoral access under local anesthesia with mild analgesic medication in all cases. Mild aortic regurgitation occurred in three patients while no permanent pacemaker implantation was required. Major cardiac events or cerebrovascular events did not occur. One aneurysm spurium, with the need of one blood transfusion, occurred. All patients improved at least one NYHA class within 30 days. Conclusion TAVI for degenerated aortic bioprostheses, using the Edwards Sapien XT valve via transfemoral access is a feasible option for patients at high surgical risk. | ||
650 | 4 | |a TAVI |7 (dpeaa)DE-He213 | |
650 | 4 | |a Valve in valve |7 (dpeaa)DE-He213 | |
650 | 4 | |a Transfemoral access |7 (dpeaa)DE-He213 | |
650 | 4 | |a Degenerated bioprostheses |7 (dpeaa)DE-He213 | |
700 | 1 | |a Lange, Philipp |e verfasserin |4 aut | |
700 | 1 | |a Mair, Helmut |e verfasserin |4 aut | |
700 | 1 | |a Becker, Christoph |e verfasserin |4 aut | |
700 | 1 | |a Schmitz, Christoph |e verfasserin |4 aut | |
700 | 1 | |a Steinbeck, Gerhard |e verfasserin |4 aut | |
700 | 1 | |a Kupatt, Christian |e verfasserin |4 aut | |
773 | 0 | 8 | |i Enthalten in |t Zeitschrift für Kardiologie |d Darmstadt : Steinkopff, 1997 |g 101(2012), 12 vom: 23. Juni, Seite 993-1001 |w (DE-627)254911137 |w (DE-600)1463330-9 |x 1435-1285 |7 nnns |
773 | 1 | 8 | |g volume:101 |g year:2012 |g number:12 |g day:23 |g month:06 |g pages:993-1001 |
856 | 4 | 0 | |u https://dx.doi.org/10.1007/s00392-012-0488-3 |z lizenzpflichtig |3 Volltext |
912 | |a GBV_USEFLAG_A | ||
912 | |a SYSFLAG_A | ||
912 | |a GBV_SPRINGER | ||
912 | |a SSG-OLC-PHA | ||
912 | |a GBV_ILN_20 | ||
912 | |a GBV_ILN_22 | ||
912 | |a GBV_ILN_23 | ||
912 | |a GBV_ILN_24 | ||
912 | |a GBV_ILN_31 | ||
912 | |a GBV_ILN_32 | ||
912 | |a GBV_ILN_39 | ||
912 | |a GBV_ILN_40 | ||
912 | |a GBV_ILN_60 | ||
912 | |a GBV_ILN_62 | ||
912 | |a GBV_ILN_69 | ||
912 | |a GBV_ILN_70 | ||
912 | |a GBV_ILN_73 | ||
912 | |a GBV_ILN_74 | ||
912 | |a GBV_ILN_90 | ||
912 | |a GBV_ILN_95 | ||
912 | |a GBV_ILN_100 | ||
912 | |a GBV_ILN_105 | ||
912 | |a GBV_ILN_110 | ||
912 | |a GBV_ILN_120 | ||
912 | |a GBV_ILN_138 | ||
912 | |a GBV_ILN_152 | ||
912 | |a GBV_ILN_161 | ||
912 | |a GBV_ILN_171 | ||
912 | |a GBV_ILN_187 | ||
912 | |a GBV_ILN_224 | ||
912 | |a GBV_ILN_250 | ||
912 | |a GBV_ILN_281 | ||
912 | |a GBV_ILN_285 | ||
912 | |a GBV_ILN_293 | ||
912 | |a GBV_ILN_370 | ||
912 | |a GBV_ILN_602 | ||
912 | |a GBV_ILN_702 | ||
936 | b | k | |a 44.67 |q ASE |
936 | b | k | |a 44.85 |q ASE |
951 | |a AR | ||
952 | |d 101 |j 2012 |e 12 |b 23 |c 06 |h 993-1001 |
author_variant |
m g mg p l pl h m hm c b cb c s cs g s gs c k ck |
---|---|
matchkey_str |
article:14351285:2012----::rncteeewrsaintavivlemlnainneeeaearibors |
hierarchy_sort_str |
2012 |
bklnumber |
44.67 44.85 |
publishDate |
2012 |
allfields |
10.1007/s00392-012-0488-3 doi (DE-627)SPR004805895 (SPR)s00392-012-0488-3-e DE-627 ger DE-627 rakwb eng 610 ASE 610 ASE 44.67 bkl 44.85 bkl Greif, Martin verfasserin aut Transcatheter Edwards Sapien XT valve in valve implantation in degenerated aortic bioprostheses via transfemoral access 2012 Text txt rdacontent Computermedien c rdamedia Online-Ressource cr rdacarrier Objectives Surgical treatment of degenerated aortic bioprostheses is associated with an increased risk of morbidity and mortality, especially in elderly patients with significant co-morbidities. Therefore, transcatheter aortic valve implantation (TAVI) performed as valve in valve technique appears as an attractive alternative treatment option. We report of a case series of seven patients with dysfunctional bioprosthetic aortic heart valves who have been treated with TAVI via transfemoral access. Methods and results Valve in valve implantation using the Edwards Sapien XT bioprostheses (Edwards Lifesciences LLC, Irvine, CA, USA) was performed in eight patients (3 men, 5 women, mean age 85.3 ± 6.1 years) with a high operative risk (logistic euroSCORE 27.2 ± 7.3). Six patients underwent TAVI because of high grade stenosis of the aortic bioprostheses, whereas two patients presented with high grade regurgitation. All patients suffered at least from NYHA class III dyspnea during admission. TAVI was successfully performed via transfemoral access under local anesthesia with mild analgesic medication in all cases. Mild aortic regurgitation occurred in three patients while no permanent pacemaker implantation was required. Major cardiac events or cerebrovascular events did not occur. One aneurysm spurium, with the need of one blood transfusion, occurred. All patients improved at least one NYHA class within 30 days. Conclusion TAVI for degenerated aortic bioprostheses, using the Edwards Sapien XT valve via transfemoral access is a feasible option for patients at high surgical risk. TAVI (dpeaa)DE-He213 Valve in valve (dpeaa)DE-He213 Transfemoral access (dpeaa)DE-He213 Degenerated bioprostheses (dpeaa)DE-He213 Lange, Philipp verfasserin aut Mair, Helmut verfasserin aut Becker, Christoph verfasserin aut Schmitz, Christoph verfasserin aut Steinbeck, Gerhard verfasserin aut Kupatt, Christian verfasserin aut Enthalten in Zeitschrift für Kardiologie Darmstadt : Steinkopff, 1997 101(2012), 12 vom: 23. Juni, Seite 993-1001 (DE-627)254911137 (DE-600)1463330-9 1435-1285 nnns volume:101 year:2012 number:12 day:23 month:06 pages:993-1001 https://dx.doi.org/10.1007/s00392-012-0488-3 lizenzpflichtig Volltext GBV_USEFLAG_A SYSFLAG_A GBV_SPRINGER SSG-OLC-PHA GBV_ILN_20 GBV_ILN_22 GBV_ILN_23 GBV_ILN_24 GBV_ILN_31 GBV_ILN_32 GBV_ILN_39 GBV_ILN_40 GBV_ILN_60 GBV_ILN_62 GBV_ILN_69 GBV_ILN_70 GBV_ILN_73 GBV_ILN_74 GBV_ILN_90 GBV_ILN_95 GBV_ILN_100 GBV_ILN_105 GBV_ILN_110 GBV_ILN_120 GBV_ILN_138 GBV_ILN_152 GBV_ILN_161 GBV_ILN_171 GBV_ILN_187 GBV_ILN_224 GBV_ILN_250 GBV_ILN_281 GBV_ILN_285 GBV_ILN_293 GBV_ILN_370 GBV_ILN_602 GBV_ILN_702 44.67 ASE 44.85 ASE AR 101 2012 12 23 06 993-1001 |
spelling |
10.1007/s00392-012-0488-3 doi (DE-627)SPR004805895 (SPR)s00392-012-0488-3-e DE-627 ger DE-627 rakwb eng 610 ASE 610 ASE 44.67 bkl 44.85 bkl Greif, Martin verfasserin aut Transcatheter Edwards Sapien XT valve in valve implantation in degenerated aortic bioprostheses via transfemoral access 2012 Text txt rdacontent Computermedien c rdamedia Online-Ressource cr rdacarrier Objectives Surgical treatment of degenerated aortic bioprostheses is associated with an increased risk of morbidity and mortality, especially in elderly patients with significant co-morbidities. Therefore, transcatheter aortic valve implantation (TAVI) performed as valve in valve technique appears as an attractive alternative treatment option. We report of a case series of seven patients with dysfunctional bioprosthetic aortic heart valves who have been treated with TAVI via transfemoral access. Methods and results Valve in valve implantation using the Edwards Sapien XT bioprostheses (Edwards Lifesciences LLC, Irvine, CA, USA) was performed in eight patients (3 men, 5 women, mean age 85.3 ± 6.1 years) with a high operative risk (logistic euroSCORE 27.2 ± 7.3). Six patients underwent TAVI because of high grade stenosis of the aortic bioprostheses, whereas two patients presented with high grade regurgitation. All patients suffered at least from NYHA class III dyspnea during admission. TAVI was successfully performed via transfemoral access under local anesthesia with mild analgesic medication in all cases. Mild aortic regurgitation occurred in three patients while no permanent pacemaker implantation was required. Major cardiac events or cerebrovascular events did not occur. One aneurysm spurium, with the need of one blood transfusion, occurred. All patients improved at least one NYHA class within 30 days. Conclusion TAVI for degenerated aortic bioprostheses, using the Edwards Sapien XT valve via transfemoral access is a feasible option for patients at high surgical risk. TAVI (dpeaa)DE-He213 Valve in valve (dpeaa)DE-He213 Transfemoral access (dpeaa)DE-He213 Degenerated bioprostheses (dpeaa)DE-He213 Lange, Philipp verfasserin aut Mair, Helmut verfasserin aut Becker, Christoph verfasserin aut Schmitz, Christoph verfasserin aut Steinbeck, Gerhard verfasserin aut Kupatt, Christian verfasserin aut Enthalten in Zeitschrift für Kardiologie Darmstadt : Steinkopff, 1997 101(2012), 12 vom: 23. Juni, Seite 993-1001 (DE-627)254911137 (DE-600)1463330-9 1435-1285 nnns volume:101 year:2012 number:12 day:23 month:06 pages:993-1001 https://dx.doi.org/10.1007/s00392-012-0488-3 lizenzpflichtig Volltext GBV_USEFLAG_A SYSFLAG_A GBV_SPRINGER SSG-OLC-PHA GBV_ILN_20 GBV_ILN_22 GBV_ILN_23 GBV_ILN_24 GBV_ILN_31 GBV_ILN_32 GBV_ILN_39 GBV_ILN_40 GBV_ILN_60 GBV_ILN_62 GBV_ILN_69 GBV_ILN_70 GBV_ILN_73 GBV_ILN_74 GBV_ILN_90 GBV_ILN_95 GBV_ILN_100 GBV_ILN_105 GBV_ILN_110 GBV_ILN_120 GBV_ILN_138 GBV_ILN_152 GBV_ILN_161 GBV_ILN_171 GBV_ILN_187 GBV_ILN_224 GBV_ILN_250 GBV_ILN_281 GBV_ILN_285 GBV_ILN_293 GBV_ILN_370 GBV_ILN_602 GBV_ILN_702 44.67 ASE 44.85 ASE AR 101 2012 12 23 06 993-1001 |
allfields_unstemmed |
10.1007/s00392-012-0488-3 doi (DE-627)SPR004805895 (SPR)s00392-012-0488-3-e DE-627 ger DE-627 rakwb eng 610 ASE 610 ASE 44.67 bkl 44.85 bkl Greif, Martin verfasserin aut Transcatheter Edwards Sapien XT valve in valve implantation in degenerated aortic bioprostheses via transfemoral access 2012 Text txt rdacontent Computermedien c rdamedia Online-Ressource cr rdacarrier Objectives Surgical treatment of degenerated aortic bioprostheses is associated with an increased risk of morbidity and mortality, especially in elderly patients with significant co-morbidities. Therefore, transcatheter aortic valve implantation (TAVI) performed as valve in valve technique appears as an attractive alternative treatment option. We report of a case series of seven patients with dysfunctional bioprosthetic aortic heart valves who have been treated with TAVI via transfemoral access. Methods and results Valve in valve implantation using the Edwards Sapien XT bioprostheses (Edwards Lifesciences LLC, Irvine, CA, USA) was performed in eight patients (3 men, 5 women, mean age 85.3 ± 6.1 years) with a high operative risk (logistic euroSCORE 27.2 ± 7.3). Six patients underwent TAVI because of high grade stenosis of the aortic bioprostheses, whereas two patients presented with high grade regurgitation. All patients suffered at least from NYHA class III dyspnea during admission. TAVI was successfully performed via transfemoral access under local anesthesia with mild analgesic medication in all cases. Mild aortic regurgitation occurred in three patients while no permanent pacemaker implantation was required. Major cardiac events or cerebrovascular events did not occur. One aneurysm spurium, with the need of one blood transfusion, occurred. All patients improved at least one NYHA class within 30 days. Conclusion TAVI for degenerated aortic bioprostheses, using the Edwards Sapien XT valve via transfemoral access is a feasible option for patients at high surgical risk. TAVI (dpeaa)DE-He213 Valve in valve (dpeaa)DE-He213 Transfemoral access (dpeaa)DE-He213 Degenerated bioprostheses (dpeaa)DE-He213 Lange, Philipp verfasserin aut Mair, Helmut verfasserin aut Becker, Christoph verfasserin aut Schmitz, Christoph verfasserin aut Steinbeck, Gerhard verfasserin aut Kupatt, Christian verfasserin aut Enthalten in Zeitschrift für Kardiologie Darmstadt : Steinkopff, 1997 101(2012), 12 vom: 23. Juni, Seite 993-1001 (DE-627)254911137 (DE-600)1463330-9 1435-1285 nnns volume:101 year:2012 number:12 day:23 month:06 pages:993-1001 https://dx.doi.org/10.1007/s00392-012-0488-3 lizenzpflichtig Volltext GBV_USEFLAG_A SYSFLAG_A GBV_SPRINGER SSG-OLC-PHA GBV_ILN_20 GBV_ILN_22 GBV_ILN_23 GBV_ILN_24 GBV_ILN_31 GBV_ILN_32 GBV_ILN_39 GBV_ILN_40 GBV_ILN_60 GBV_ILN_62 GBV_ILN_69 GBV_ILN_70 GBV_ILN_73 GBV_ILN_74 GBV_ILN_90 GBV_ILN_95 GBV_ILN_100 GBV_ILN_105 GBV_ILN_110 GBV_ILN_120 GBV_ILN_138 GBV_ILN_152 GBV_ILN_161 GBV_ILN_171 GBV_ILN_187 GBV_ILN_224 GBV_ILN_250 GBV_ILN_281 GBV_ILN_285 GBV_ILN_293 GBV_ILN_370 GBV_ILN_602 GBV_ILN_702 44.67 ASE 44.85 ASE AR 101 2012 12 23 06 993-1001 |
allfieldsGer |
10.1007/s00392-012-0488-3 doi (DE-627)SPR004805895 (SPR)s00392-012-0488-3-e DE-627 ger DE-627 rakwb eng 610 ASE 610 ASE 44.67 bkl 44.85 bkl Greif, Martin verfasserin aut Transcatheter Edwards Sapien XT valve in valve implantation in degenerated aortic bioprostheses via transfemoral access 2012 Text txt rdacontent Computermedien c rdamedia Online-Ressource cr rdacarrier Objectives Surgical treatment of degenerated aortic bioprostheses is associated with an increased risk of morbidity and mortality, especially in elderly patients with significant co-morbidities. Therefore, transcatheter aortic valve implantation (TAVI) performed as valve in valve technique appears as an attractive alternative treatment option. We report of a case series of seven patients with dysfunctional bioprosthetic aortic heart valves who have been treated with TAVI via transfemoral access. Methods and results Valve in valve implantation using the Edwards Sapien XT bioprostheses (Edwards Lifesciences LLC, Irvine, CA, USA) was performed in eight patients (3 men, 5 women, mean age 85.3 ± 6.1 years) with a high operative risk (logistic euroSCORE 27.2 ± 7.3). Six patients underwent TAVI because of high grade stenosis of the aortic bioprostheses, whereas two patients presented with high grade regurgitation. All patients suffered at least from NYHA class III dyspnea during admission. TAVI was successfully performed via transfemoral access under local anesthesia with mild analgesic medication in all cases. Mild aortic regurgitation occurred in three patients while no permanent pacemaker implantation was required. Major cardiac events or cerebrovascular events did not occur. One aneurysm spurium, with the need of one blood transfusion, occurred. All patients improved at least one NYHA class within 30 days. Conclusion TAVI for degenerated aortic bioprostheses, using the Edwards Sapien XT valve via transfemoral access is a feasible option for patients at high surgical risk. TAVI (dpeaa)DE-He213 Valve in valve (dpeaa)DE-He213 Transfemoral access (dpeaa)DE-He213 Degenerated bioprostheses (dpeaa)DE-He213 Lange, Philipp verfasserin aut Mair, Helmut verfasserin aut Becker, Christoph verfasserin aut Schmitz, Christoph verfasserin aut Steinbeck, Gerhard verfasserin aut Kupatt, Christian verfasserin aut Enthalten in Zeitschrift für Kardiologie Darmstadt : Steinkopff, 1997 101(2012), 12 vom: 23. Juni, Seite 993-1001 (DE-627)254911137 (DE-600)1463330-9 1435-1285 nnns volume:101 year:2012 number:12 day:23 month:06 pages:993-1001 https://dx.doi.org/10.1007/s00392-012-0488-3 lizenzpflichtig Volltext GBV_USEFLAG_A SYSFLAG_A GBV_SPRINGER SSG-OLC-PHA GBV_ILN_20 GBV_ILN_22 GBV_ILN_23 GBV_ILN_24 GBV_ILN_31 GBV_ILN_32 GBV_ILN_39 GBV_ILN_40 GBV_ILN_60 GBV_ILN_62 GBV_ILN_69 GBV_ILN_70 GBV_ILN_73 GBV_ILN_74 GBV_ILN_90 GBV_ILN_95 GBV_ILN_100 GBV_ILN_105 GBV_ILN_110 GBV_ILN_120 GBV_ILN_138 GBV_ILN_152 GBV_ILN_161 GBV_ILN_171 GBV_ILN_187 GBV_ILN_224 GBV_ILN_250 GBV_ILN_281 GBV_ILN_285 GBV_ILN_293 GBV_ILN_370 GBV_ILN_602 GBV_ILN_702 44.67 ASE 44.85 ASE AR 101 2012 12 23 06 993-1001 |
allfieldsSound |
10.1007/s00392-012-0488-3 doi (DE-627)SPR004805895 (SPR)s00392-012-0488-3-e DE-627 ger DE-627 rakwb eng 610 ASE 610 ASE 44.67 bkl 44.85 bkl Greif, Martin verfasserin aut Transcatheter Edwards Sapien XT valve in valve implantation in degenerated aortic bioprostheses via transfemoral access 2012 Text txt rdacontent Computermedien c rdamedia Online-Ressource cr rdacarrier Objectives Surgical treatment of degenerated aortic bioprostheses is associated with an increased risk of morbidity and mortality, especially in elderly patients with significant co-morbidities. Therefore, transcatheter aortic valve implantation (TAVI) performed as valve in valve technique appears as an attractive alternative treatment option. We report of a case series of seven patients with dysfunctional bioprosthetic aortic heart valves who have been treated with TAVI via transfemoral access. Methods and results Valve in valve implantation using the Edwards Sapien XT bioprostheses (Edwards Lifesciences LLC, Irvine, CA, USA) was performed in eight patients (3 men, 5 women, mean age 85.3 ± 6.1 years) with a high operative risk (logistic euroSCORE 27.2 ± 7.3). Six patients underwent TAVI because of high grade stenosis of the aortic bioprostheses, whereas two patients presented with high grade regurgitation. All patients suffered at least from NYHA class III dyspnea during admission. TAVI was successfully performed via transfemoral access under local anesthesia with mild analgesic medication in all cases. Mild aortic regurgitation occurred in three patients while no permanent pacemaker implantation was required. Major cardiac events or cerebrovascular events did not occur. One aneurysm spurium, with the need of one blood transfusion, occurred. All patients improved at least one NYHA class within 30 days. Conclusion TAVI for degenerated aortic bioprostheses, using the Edwards Sapien XT valve via transfemoral access is a feasible option for patients at high surgical risk. TAVI (dpeaa)DE-He213 Valve in valve (dpeaa)DE-He213 Transfemoral access (dpeaa)DE-He213 Degenerated bioprostheses (dpeaa)DE-He213 Lange, Philipp verfasserin aut Mair, Helmut verfasserin aut Becker, Christoph verfasserin aut Schmitz, Christoph verfasserin aut Steinbeck, Gerhard verfasserin aut Kupatt, Christian verfasserin aut Enthalten in Zeitschrift für Kardiologie Darmstadt : Steinkopff, 1997 101(2012), 12 vom: 23. Juni, Seite 993-1001 (DE-627)254911137 (DE-600)1463330-9 1435-1285 nnns volume:101 year:2012 number:12 day:23 month:06 pages:993-1001 https://dx.doi.org/10.1007/s00392-012-0488-3 lizenzpflichtig Volltext GBV_USEFLAG_A SYSFLAG_A GBV_SPRINGER SSG-OLC-PHA GBV_ILN_20 GBV_ILN_22 GBV_ILN_23 GBV_ILN_24 GBV_ILN_31 GBV_ILN_32 GBV_ILN_39 GBV_ILN_40 GBV_ILN_60 GBV_ILN_62 GBV_ILN_69 GBV_ILN_70 GBV_ILN_73 GBV_ILN_74 GBV_ILN_90 GBV_ILN_95 GBV_ILN_100 GBV_ILN_105 GBV_ILN_110 GBV_ILN_120 GBV_ILN_138 GBV_ILN_152 GBV_ILN_161 GBV_ILN_171 GBV_ILN_187 GBV_ILN_224 GBV_ILN_250 GBV_ILN_281 GBV_ILN_285 GBV_ILN_293 GBV_ILN_370 GBV_ILN_602 GBV_ILN_702 44.67 ASE 44.85 ASE AR 101 2012 12 23 06 993-1001 |
language |
English |
source |
Enthalten in Zeitschrift für Kardiologie 101(2012), 12 vom: 23. Juni, Seite 993-1001 volume:101 year:2012 number:12 day:23 month:06 pages:993-1001 |
sourceStr |
Enthalten in Zeitschrift für Kardiologie 101(2012), 12 vom: 23. Juni, Seite 993-1001 volume:101 year:2012 number:12 day:23 month:06 pages:993-1001 |
format_phy_str_mv |
Article |
institution |
findex.gbv.de |
topic_facet |
TAVI Valve in valve Transfemoral access Degenerated bioprostheses |
dewey-raw |
610 |
isfreeaccess_bool |
false |
container_title |
Zeitschrift für Kardiologie |
authorswithroles_txt_mv |
Greif, Martin @@aut@@ Lange, Philipp @@aut@@ Mair, Helmut @@aut@@ Becker, Christoph @@aut@@ Schmitz, Christoph @@aut@@ Steinbeck, Gerhard @@aut@@ Kupatt, Christian @@aut@@ |
publishDateDaySort_date |
2012-06-23T00:00:00Z |
hierarchy_top_id |
254911137 |
dewey-sort |
3610 |
id |
SPR004805895 |
language_de |
englisch |
fullrecord |
<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim"><record><leader>01000caa a22002652 4500</leader><controlfield tag="001">SPR004805895</controlfield><controlfield tag="003">DE-627</controlfield><controlfield tag="005">20230519112358.0</controlfield><controlfield tag="007">cr uuu---uuuuu</controlfield><controlfield tag="008">201001s2012 xx |||||o 00| ||eng c</controlfield><datafield tag="024" ind1="7" ind2=" "><subfield code="a">10.1007/s00392-012-0488-3</subfield><subfield code="2">doi</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-627)SPR004805895</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(SPR)s00392-012-0488-3-e</subfield></datafield><datafield tag="040" ind1=" " ind2=" "><subfield code="a">DE-627</subfield><subfield code="b">ger</subfield><subfield code="c">DE-627</subfield><subfield code="e">rakwb</subfield></datafield><datafield tag="041" ind1=" " ind2=" "><subfield code="a">eng</subfield></datafield><datafield tag="082" ind1="0" ind2="4"><subfield code="a">610</subfield><subfield code="q">ASE</subfield></datafield><datafield tag="082" ind1="0" ind2="4"><subfield code="a">610</subfield><subfield code="q">ASE</subfield></datafield><datafield tag="084" ind1=" " ind2=" "><subfield code="a">44.67</subfield><subfield code="2">bkl</subfield></datafield><datafield tag="084" ind1=" " ind2=" "><subfield code="a">44.85</subfield><subfield code="2">bkl</subfield></datafield><datafield tag="100" ind1="1" ind2=" "><subfield code="a">Greif, Martin</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="245" ind1="1" ind2="0"><subfield code="a">Transcatheter Edwards Sapien XT valve in valve implantation in degenerated aortic bioprostheses via transfemoral access</subfield></datafield><datafield tag="264" ind1=" " ind2="1"><subfield code="c">2012</subfield></datafield><datafield tag="336" ind1=" " ind2=" "><subfield code="a">Text</subfield><subfield code="b">txt</subfield><subfield code="2">rdacontent</subfield></datafield><datafield tag="337" ind1=" " ind2=" "><subfield code="a">Computermedien</subfield><subfield code="b">c</subfield><subfield code="2">rdamedia</subfield></datafield><datafield tag="338" ind1=" " ind2=" "><subfield code="a">Online-Ressource</subfield><subfield code="b">cr</subfield><subfield code="2">rdacarrier</subfield></datafield><datafield tag="520" ind1=" " ind2=" "><subfield code="a">Objectives Surgical treatment of degenerated aortic bioprostheses is associated with an increased risk of morbidity and mortality, especially in elderly patients with significant co-morbidities. Therefore, transcatheter aortic valve implantation (TAVI) performed as valve in valve technique appears as an attractive alternative treatment option. We report of a case series of seven patients with dysfunctional bioprosthetic aortic heart valves who have been treated with TAVI via transfemoral access. Methods and results Valve in valve implantation using the Edwards Sapien XT bioprostheses (Edwards Lifesciences LLC, Irvine, CA, USA) was performed in eight patients (3 men, 5 women, mean age 85.3 ± 6.1 years) with a high operative risk (logistic euroSCORE 27.2 ± 7.3). Six patients underwent TAVI because of high grade stenosis of the aortic bioprostheses, whereas two patients presented with high grade regurgitation. All patients suffered at least from NYHA class III dyspnea during admission. TAVI was successfully performed via transfemoral access under local anesthesia with mild analgesic medication in all cases. Mild aortic regurgitation occurred in three patients while no permanent pacemaker implantation was required. Major cardiac events or cerebrovascular events did not occur. One aneurysm spurium, with the need of one blood transfusion, occurred. All patients improved at least one NYHA class within 30 days. Conclusion TAVI for degenerated aortic bioprostheses, using the Edwards Sapien XT valve via transfemoral access is a feasible option for patients at high surgical risk.</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">TAVI</subfield><subfield code="7">(dpeaa)DE-He213</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Valve in valve</subfield><subfield code="7">(dpeaa)DE-He213</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Transfemoral access</subfield><subfield code="7">(dpeaa)DE-He213</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Degenerated bioprostheses</subfield><subfield code="7">(dpeaa)DE-He213</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Lange, Philipp</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Mair, Helmut</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Becker, Christoph</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Schmitz, Christoph</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Steinbeck, Gerhard</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Kupatt, Christian</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="773" ind1="0" ind2="8"><subfield code="i">Enthalten in</subfield><subfield code="t">Zeitschrift für Kardiologie</subfield><subfield code="d">Darmstadt : Steinkopff, 1997</subfield><subfield code="g">101(2012), 12 vom: 23. Juni, Seite 993-1001</subfield><subfield code="w">(DE-627)254911137</subfield><subfield code="w">(DE-600)1463330-9</subfield><subfield code="x">1435-1285</subfield><subfield code="7">nnns</subfield></datafield><datafield tag="773" ind1="1" ind2="8"><subfield code="g">volume:101</subfield><subfield code="g">year:2012</subfield><subfield code="g">number:12</subfield><subfield code="g">day:23</subfield><subfield code="g">month:06</subfield><subfield code="g">pages:993-1001</subfield></datafield><datafield tag="856" ind1="4" ind2="0"><subfield code="u">https://dx.doi.org/10.1007/s00392-012-0488-3</subfield><subfield code="z">lizenzpflichtig</subfield><subfield code="3">Volltext</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_USEFLAG_A</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">SYSFLAG_A</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_SPRINGER</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">SSG-OLC-PHA</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_20</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_22</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_23</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_24</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_31</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_32</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_39</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_40</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_60</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_62</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_69</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_70</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_73</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_74</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_90</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_95</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_100</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_105</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_110</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_120</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_138</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_152</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_161</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_171</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_187</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_224</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_250</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_281</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_285</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_293</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_370</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_602</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_702</subfield></datafield><datafield tag="936" ind1="b" ind2="k"><subfield code="a">44.67</subfield><subfield code="q">ASE</subfield></datafield><datafield tag="936" ind1="b" ind2="k"><subfield code="a">44.85</subfield><subfield code="q">ASE</subfield></datafield><datafield tag="951" ind1=" " ind2=" "><subfield code="a">AR</subfield></datafield><datafield tag="952" ind1=" " ind2=" "><subfield code="d">101</subfield><subfield code="j">2012</subfield><subfield code="e">12</subfield><subfield code="b">23</subfield><subfield code="c">06</subfield><subfield code="h">993-1001</subfield></datafield></record></collection>
|
author |
Greif, Martin |
spellingShingle |
Greif, Martin ddc 610 bkl 44.67 bkl 44.85 misc TAVI misc Valve in valve misc Transfemoral access misc Degenerated bioprostheses Transcatheter Edwards Sapien XT valve in valve implantation in degenerated aortic bioprostheses via transfemoral access |
authorStr |
Greif, Martin |
ppnlink_with_tag_str_mv |
@@773@@(DE-627)254911137 |
format |
electronic Article |
dewey-ones |
610 - Medicine & health |
delete_txt_mv |
keep |
author_role |
aut aut aut aut aut aut aut |
collection |
springer |
remote_str |
true |
illustrated |
Not Illustrated |
issn |
1435-1285 |
topic_title |
610 ASE 44.67 bkl 44.85 bkl Transcatheter Edwards Sapien XT valve in valve implantation in degenerated aortic bioprostheses via transfemoral access TAVI (dpeaa)DE-He213 Valve in valve (dpeaa)DE-He213 Transfemoral access (dpeaa)DE-He213 Degenerated bioprostheses (dpeaa)DE-He213 |
topic |
ddc 610 bkl 44.67 bkl 44.85 misc TAVI misc Valve in valve misc Transfemoral access misc Degenerated bioprostheses |
topic_unstemmed |
ddc 610 bkl 44.67 bkl 44.85 misc TAVI misc Valve in valve misc Transfemoral access misc Degenerated bioprostheses |
topic_browse |
ddc 610 bkl 44.67 bkl 44.85 misc TAVI misc Valve in valve misc Transfemoral access misc Degenerated bioprostheses |
format_facet |
Elektronische Aufsätze Aufsätze Elektronische Ressource |
format_main_str_mv |
Text Zeitschrift/Artikel |
carriertype_str_mv |
cr |
hierarchy_parent_title |
Zeitschrift für Kardiologie |
hierarchy_parent_id |
254911137 |
dewey-tens |
610 - Medicine & health |
hierarchy_top_title |
Zeitschrift für Kardiologie |
isfreeaccess_txt |
false |
familylinks_str_mv |
(DE-627)254911137 (DE-600)1463330-9 |
title |
Transcatheter Edwards Sapien XT valve in valve implantation in degenerated aortic bioprostheses via transfemoral access |
ctrlnum |
(DE-627)SPR004805895 (SPR)s00392-012-0488-3-e |
title_full |
Transcatheter Edwards Sapien XT valve in valve implantation in degenerated aortic bioprostheses via transfemoral access |
author_sort |
Greif, Martin |
journal |
Zeitschrift für Kardiologie |
journalStr |
Zeitschrift für Kardiologie |
lang_code |
eng |
isOA_bool |
false |
dewey-hundreds |
600 - Technology |
recordtype |
marc |
publishDateSort |
2012 |
contenttype_str_mv |
txt |
container_start_page |
993 |
author_browse |
Greif, Martin Lange, Philipp Mair, Helmut Becker, Christoph Schmitz, Christoph Steinbeck, Gerhard Kupatt, Christian |
container_volume |
101 |
class |
610 ASE 44.67 bkl 44.85 bkl |
format_se |
Elektronische Aufsätze |
author-letter |
Greif, Martin |
doi_str_mv |
10.1007/s00392-012-0488-3 |
dewey-full |
610 |
author2-role |
verfasserin |
title_sort |
transcatheter edwards sapien xt valve in valve implantation in degenerated aortic bioprostheses via transfemoral access |
title_auth |
Transcatheter Edwards Sapien XT valve in valve implantation in degenerated aortic bioprostheses via transfemoral access |
abstract |
Objectives Surgical treatment of degenerated aortic bioprostheses is associated with an increased risk of morbidity and mortality, especially in elderly patients with significant co-morbidities. Therefore, transcatheter aortic valve implantation (TAVI) performed as valve in valve technique appears as an attractive alternative treatment option. We report of a case series of seven patients with dysfunctional bioprosthetic aortic heart valves who have been treated with TAVI via transfemoral access. Methods and results Valve in valve implantation using the Edwards Sapien XT bioprostheses (Edwards Lifesciences LLC, Irvine, CA, USA) was performed in eight patients (3 men, 5 women, mean age 85.3 ± 6.1 years) with a high operative risk (logistic euroSCORE 27.2 ± 7.3). Six patients underwent TAVI because of high grade stenosis of the aortic bioprostheses, whereas two patients presented with high grade regurgitation. All patients suffered at least from NYHA class III dyspnea during admission. TAVI was successfully performed via transfemoral access under local anesthesia with mild analgesic medication in all cases. Mild aortic regurgitation occurred in three patients while no permanent pacemaker implantation was required. Major cardiac events or cerebrovascular events did not occur. One aneurysm spurium, with the need of one blood transfusion, occurred. All patients improved at least one NYHA class within 30 days. Conclusion TAVI for degenerated aortic bioprostheses, using the Edwards Sapien XT valve via transfemoral access is a feasible option for patients at high surgical risk. |
abstractGer |
Objectives Surgical treatment of degenerated aortic bioprostheses is associated with an increased risk of morbidity and mortality, especially in elderly patients with significant co-morbidities. Therefore, transcatheter aortic valve implantation (TAVI) performed as valve in valve technique appears as an attractive alternative treatment option. We report of a case series of seven patients with dysfunctional bioprosthetic aortic heart valves who have been treated with TAVI via transfemoral access. Methods and results Valve in valve implantation using the Edwards Sapien XT bioprostheses (Edwards Lifesciences LLC, Irvine, CA, USA) was performed in eight patients (3 men, 5 women, mean age 85.3 ± 6.1 years) with a high operative risk (logistic euroSCORE 27.2 ± 7.3). Six patients underwent TAVI because of high grade stenosis of the aortic bioprostheses, whereas two patients presented with high grade regurgitation. All patients suffered at least from NYHA class III dyspnea during admission. TAVI was successfully performed via transfemoral access under local anesthesia with mild analgesic medication in all cases. Mild aortic regurgitation occurred in three patients while no permanent pacemaker implantation was required. Major cardiac events or cerebrovascular events did not occur. One aneurysm spurium, with the need of one blood transfusion, occurred. All patients improved at least one NYHA class within 30 days. Conclusion TAVI for degenerated aortic bioprostheses, using the Edwards Sapien XT valve via transfemoral access is a feasible option for patients at high surgical risk. |
abstract_unstemmed |
Objectives Surgical treatment of degenerated aortic bioprostheses is associated with an increased risk of morbidity and mortality, especially in elderly patients with significant co-morbidities. Therefore, transcatheter aortic valve implantation (TAVI) performed as valve in valve technique appears as an attractive alternative treatment option. We report of a case series of seven patients with dysfunctional bioprosthetic aortic heart valves who have been treated with TAVI via transfemoral access. Methods and results Valve in valve implantation using the Edwards Sapien XT bioprostheses (Edwards Lifesciences LLC, Irvine, CA, USA) was performed in eight patients (3 men, 5 women, mean age 85.3 ± 6.1 years) with a high operative risk (logistic euroSCORE 27.2 ± 7.3). Six patients underwent TAVI because of high grade stenosis of the aortic bioprostheses, whereas two patients presented with high grade regurgitation. All patients suffered at least from NYHA class III dyspnea during admission. TAVI was successfully performed via transfemoral access under local anesthesia with mild analgesic medication in all cases. Mild aortic regurgitation occurred in three patients while no permanent pacemaker implantation was required. Major cardiac events or cerebrovascular events did not occur. One aneurysm spurium, with the need of one blood transfusion, occurred. All patients improved at least one NYHA class within 30 days. Conclusion TAVI for degenerated aortic bioprostheses, using the Edwards Sapien XT valve via transfemoral access is a feasible option for patients at high surgical risk. |
collection_details |
GBV_USEFLAG_A SYSFLAG_A GBV_SPRINGER SSG-OLC-PHA GBV_ILN_20 GBV_ILN_22 GBV_ILN_23 GBV_ILN_24 GBV_ILN_31 GBV_ILN_32 GBV_ILN_39 GBV_ILN_40 GBV_ILN_60 GBV_ILN_62 GBV_ILN_69 GBV_ILN_70 GBV_ILN_73 GBV_ILN_74 GBV_ILN_90 GBV_ILN_95 GBV_ILN_100 GBV_ILN_105 GBV_ILN_110 GBV_ILN_120 GBV_ILN_138 GBV_ILN_152 GBV_ILN_161 GBV_ILN_171 GBV_ILN_187 GBV_ILN_224 GBV_ILN_250 GBV_ILN_281 GBV_ILN_285 GBV_ILN_293 GBV_ILN_370 GBV_ILN_602 GBV_ILN_702 |
container_issue |
12 |
title_short |
Transcatheter Edwards Sapien XT valve in valve implantation in degenerated aortic bioprostheses via transfemoral access |
url |
https://dx.doi.org/10.1007/s00392-012-0488-3 |
remote_bool |
true |
author2 |
Lange, Philipp Mair, Helmut Becker, Christoph Schmitz, Christoph Steinbeck, Gerhard Kupatt, Christian |
author2Str |
Lange, Philipp Mair, Helmut Becker, Christoph Schmitz, Christoph Steinbeck, Gerhard Kupatt, Christian |
ppnlink |
254911137 |
mediatype_str_mv |
c |
isOA_txt |
false |
hochschulschrift_bool |
false |
doi_str |
10.1007/s00392-012-0488-3 |
up_date |
2024-07-04T02:40:12.285Z |
_version_ |
1803614486304653312 |
fullrecord_marcxml |
<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim"><record><leader>01000caa a22002652 4500</leader><controlfield tag="001">SPR004805895</controlfield><controlfield tag="003">DE-627</controlfield><controlfield tag="005">20230519112358.0</controlfield><controlfield tag="007">cr uuu---uuuuu</controlfield><controlfield tag="008">201001s2012 xx |||||o 00| ||eng c</controlfield><datafield tag="024" ind1="7" ind2=" "><subfield code="a">10.1007/s00392-012-0488-3</subfield><subfield code="2">doi</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-627)SPR004805895</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(SPR)s00392-012-0488-3-e</subfield></datafield><datafield tag="040" ind1=" " ind2=" "><subfield code="a">DE-627</subfield><subfield code="b">ger</subfield><subfield code="c">DE-627</subfield><subfield code="e">rakwb</subfield></datafield><datafield tag="041" ind1=" " ind2=" "><subfield code="a">eng</subfield></datafield><datafield tag="082" ind1="0" ind2="4"><subfield code="a">610</subfield><subfield code="q">ASE</subfield></datafield><datafield tag="082" ind1="0" ind2="4"><subfield code="a">610</subfield><subfield code="q">ASE</subfield></datafield><datafield tag="084" ind1=" " ind2=" "><subfield code="a">44.67</subfield><subfield code="2">bkl</subfield></datafield><datafield tag="084" ind1=" " ind2=" "><subfield code="a">44.85</subfield><subfield code="2">bkl</subfield></datafield><datafield tag="100" ind1="1" ind2=" "><subfield code="a">Greif, Martin</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="245" ind1="1" ind2="0"><subfield code="a">Transcatheter Edwards Sapien XT valve in valve implantation in degenerated aortic bioprostheses via transfemoral access</subfield></datafield><datafield tag="264" ind1=" " ind2="1"><subfield code="c">2012</subfield></datafield><datafield tag="336" ind1=" " ind2=" "><subfield code="a">Text</subfield><subfield code="b">txt</subfield><subfield code="2">rdacontent</subfield></datafield><datafield tag="337" ind1=" " ind2=" "><subfield code="a">Computermedien</subfield><subfield code="b">c</subfield><subfield code="2">rdamedia</subfield></datafield><datafield tag="338" ind1=" " ind2=" "><subfield code="a">Online-Ressource</subfield><subfield code="b">cr</subfield><subfield code="2">rdacarrier</subfield></datafield><datafield tag="520" ind1=" " ind2=" "><subfield code="a">Objectives Surgical treatment of degenerated aortic bioprostheses is associated with an increased risk of morbidity and mortality, especially in elderly patients with significant co-morbidities. Therefore, transcatheter aortic valve implantation (TAVI) performed as valve in valve technique appears as an attractive alternative treatment option. We report of a case series of seven patients with dysfunctional bioprosthetic aortic heart valves who have been treated with TAVI via transfemoral access. Methods and results Valve in valve implantation using the Edwards Sapien XT bioprostheses (Edwards Lifesciences LLC, Irvine, CA, USA) was performed in eight patients (3 men, 5 women, mean age 85.3 ± 6.1 years) with a high operative risk (logistic euroSCORE 27.2 ± 7.3). Six patients underwent TAVI because of high grade stenosis of the aortic bioprostheses, whereas two patients presented with high grade regurgitation. All patients suffered at least from NYHA class III dyspnea during admission. TAVI was successfully performed via transfemoral access under local anesthesia with mild analgesic medication in all cases. Mild aortic regurgitation occurred in three patients while no permanent pacemaker implantation was required. Major cardiac events or cerebrovascular events did not occur. One aneurysm spurium, with the need of one blood transfusion, occurred. All patients improved at least one NYHA class within 30 days. Conclusion TAVI for degenerated aortic bioprostheses, using the Edwards Sapien XT valve via transfemoral access is a feasible option for patients at high surgical risk.</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">TAVI</subfield><subfield code="7">(dpeaa)DE-He213</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Valve in valve</subfield><subfield code="7">(dpeaa)DE-He213</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Transfemoral access</subfield><subfield code="7">(dpeaa)DE-He213</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Degenerated bioprostheses</subfield><subfield code="7">(dpeaa)DE-He213</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Lange, Philipp</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Mair, Helmut</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Becker, Christoph</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Schmitz, Christoph</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Steinbeck, Gerhard</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Kupatt, Christian</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="773" ind1="0" ind2="8"><subfield code="i">Enthalten in</subfield><subfield code="t">Zeitschrift für Kardiologie</subfield><subfield code="d">Darmstadt : Steinkopff, 1997</subfield><subfield code="g">101(2012), 12 vom: 23. Juni, Seite 993-1001</subfield><subfield code="w">(DE-627)254911137</subfield><subfield code="w">(DE-600)1463330-9</subfield><subfield code="x">1435-1285</subfield><subfield code="7">nnns</subfield></datafield><datafield tag="773" ind1="1" ind2="8"><subfield code="g">volume:101</subfield><subfield code="g">year:2012</subfield><subfield code="g">number:12</subfield><subfield code="g">day:23</subfield><subfield code="g">month:06</subfield><subfield code="g">pages:993-1001</subfield></datafield><datafield tag="856" ind1="4" ind2="0"><subfield code="u">https://dx.doi.org/10.1007/s00392-012-0488-3</subfield><subfield code="z">lizenzpflichtig</subfield><subfield code="3">Volltext</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_USEFLAG_A</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">SYSFLAG_A</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_SPRINGER</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">SSG-OLC-PHA</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_20</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_22</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_23</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_24</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_31</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_32</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_39</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_40</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_60</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_62</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_69</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_70</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_73</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_74</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_90</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_95</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_100</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_105</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_110</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_120</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_138</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_152</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_161</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_171</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_187</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_224</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_250</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_281</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_285</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_293</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_370</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_602</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_702</subfield></datafield><datafield tag="936" ind1="b" ind2="k"><subfield code="a">44.67</subfield><subfield code="q">ASE</subfield></datafield><datafield tag="936" ind1="b" ind2="k"><subfield code="a">44.85</subfield><subfield code="q">ASE</subfield></datafield><datafield tag="951" ind1=" " ind2=" "><subfield code="a">AR</subfield></datafield><datafield tag="952" ind1=" " ind2=" "><subfield code="d">101</subfield><subfield code="j">2012</subfield><subfield code="e">12</subfield><subfield code="b">23</subfield><subfield code="c">06</subfield><subfield code="h">993-1001</subfield></datafield></record></collection>
|
score |
7.401534 |