A systematic review of current methodology of high resolution pharyngeal manometry with and without impedance
Purpose This systematic review appraises and summaries methodology documented in studies using high resolution pharyngeal manometry (HRM) with and without impedance technology (HRIM) in adult populations. Methods Four electronic databases CINAHL, EMBASE, MEDLINE, and Cochrane Library were searched u...
Ausführliche Beschreibung
Autor*in: |
Winiker, Katharina [verfasserIn] Gillman, Anna [verfasserIn] Guiu Hernandez, Esther [verfasserIn] Huckabee, Maggie-Lee [verfasserIn] Gozdzikowska, Kristin [verfasserIn] |
---|
Format: |
E-Artikel |
---|---|
Sprache: |
Englisch |
Erschienen: |
2018 |
---|
Schlagwörter: |
---|
Übergeordnetes Werk: |
Enthalten in: European archives of oto-rhino-laryngology and head & neck - Berlin : Springer, 1864, 276(2018), 3 vom: 13. Dez., Seite 631-645 |
---|---|
Übergeordnetes Werk: |
volume:276 ; year:2018 ; number:3 ; day:13 ; month:12 ; pages:631-645 |
Links: |
---|
DOI / URN: |
10.1007/s00405-018-5240-9 |
---|
Katalog-ID: |
SPR005217199 |
---|
LEADER | 01000caa a22002652 4500 | ||
---|---|---|---|
001 | SPR005217199 | ||
003 | DE-627 | ||
005 | 20230520000758.0 | ||
007 | cr uuu---uuuuu | ||
008 | 201001s2018 xx |||||o 00| ||eng c | ||
024 | 7 | |a 10.1007/s00405-018-5240-9 |2 doi | |
035 | |a (DE-627)SPR005217199 | ||
035 | |a (SPR)s00405-018-5240-9-e | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
082 | 0 | 4 | |a 610 |q ASE |
084 | |a 44.94 |2 bkl | ||
100 | 1 | |a Winiker, Katharina |e verfasserin |4 aut | |
245 | 1 | 2 | |a A systematic review of current methodology of high resolution pharyngeal manometry with and without impedance |
264 | 1 | |c 2018 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a Computermedien |b c |2 rdamedia | ||
338 | |a Online-Ressource |b cr |2 rdacarrier | ||
520 | |a Purpose This systematic review appraises and summaries methodology documented in studies using high resolution pharyngeal manometry (HRM) with and without impedance technology (HRIM) in adult populations. Methods Four electronic databases CINAHL, EMBASE, MEDLINE, and Cochrane Library were searched up to, and including March 2017. Studies reporting pharyngeal HRM/HRIM for swallowing and/or phonatory assessment, published in peer-reviewed journals in English, German, or Spanish were assessed for the inclusion criteria. Of the selected studies, methodological aspects of data acquisition and analysis were extracted. Publications were graded based on their level of evidence and quality of methodological aspects was assessed. Results Sixty-two articles were identified eligible, from which 50 studies reported the use of HRM and 12 studies used HRIM. Of all included manuscripts, the majority utilized the ManoScan™ system (64.5%), a catheter diameter of 4.2 mm was most prevalently documented (30.6%). Most publications reported the application of topical anesthesia (53.2%). For data analysis in studies using HRM, software intrinsic to the recording system was reported most frequently (56%). A minority of the studies using HRM provided data about measurement reliability (10%). This is higher for studies using HRIM (50%). Conclusions Considerable methodological variability exists regarding data acquisition and analysis in published studies using HRM/HRIM. Lacking reports of methodology make study replications difficult and reduce the comparability across studies. More data regarding the impact of individual methodological aspects on study outcomes are further required for the development of methodological recommendations. | ||
650 | 4 | |a Deglutition |7 (dpeaa)DE-He213 | |
650 | 4 | |a Manometry |7 (dpeaa)DE-He213 | |
650 | 4 | |a High resolution manometry |7 (dpeaa)DE-He213 | |
650 | 4 | |a Impedance |7 (dpeaa)DE-He213 | |
700 | 1 | |a Gillman, Anna |e verfasserin |4 aut | |
700 | 1 | |a Guiu Hernandez, Esther |e verfasserin |4 aut | |
700 | 1 | |a Huckabee, Maggie-Lee |e verfasserin |4 aut | |
700 | 1 | |a Gozdzikowska, Kristin |e verfasserin |4 aut | |
773 | 0 | 8 | |i Enthalten in |t European archives of oto-rhino-laryngology and head & neck |d Berlin : Springer, 1864 |g 276(2018), 3 vom: 13. Dez., Seite 631-645 |w (DE-627)253722667 |w (DE-600)1459042-6 |x 1434-4726 |7 nnns |
773 | 1 | 8 | |g volume:276 |g year:2018 |g number:3 |g day:13 |g month:12 |g pages:631-645 |
856 | 4 | 0 | |u https://dx.doi.org/10.1007/s00405-018-5240-9 |z lizenzpflichtig |3 Volltext |
912 | |a GBV_USEFLAG_A | ||
912 | |a SYSFLAG_A | ||
912 | |a GBV_SPRINGER | ||
912 | |a SSG-OLC-PHA | ||
912 | |a GBV_ILN_11 | ||
912 | |a GBV_ILN_20 | ||
912 | |a GBV_ILN_22 | ||
912 | |a GBV_ILN_23 | ||
912 | |a GBV_ILN_24 | ||
912 | |a GBV_ILN_31 | ||
912 | |a GBV_ILN_32 | ||
912 | |a GBV_ILN_39 | ||
912 | |a GBV_ILN_40 | ||
912 | |a GBV_ILN_60 | ||
912 | |a GBV_ILN_62 | ||
912 | |a GBV_ILN_63 | ||
912 | |a GBV_ILN_65 | ||
912 | |a GBV_ILN_69 | ||
912 | |a GBV_ILN_70 | ||
912 | |a GBV_ILN_73 | ||
912 | |a GBV_ILN_74 | ||
912 | |a GBV_ILN_90 | ||
912 | |a GBV_ILN_95 | ||
912 | |a GBV_ILN_100 | ||
912 | |a GBV_ILN_101 | ||
912 | |a GBV_ILN_105 | ||
912 | |a GBV_ILN_110 | ||
912 | |a GBV_ILN_120 | ||
912 | |a GBV_ILN_138 | ||
912 | |a GBV_ILN_150 | ||
912 | |a GBV_ILN_151 | ||
912 | |a GBV_ILN_152 | ||
912 | |a GBV_ILN_161 | ||
912 | |a GBV_ILN_170 | ||
912 | |a GBV_ILN_171 | ||
912 | |a GBV_ILN_187 | ||
912 | |a GBV_ILN_213 | ||
912 | |a GBV_ILN_224 | ||
912 | |a GBV_ILN_230 | ||
912 | |a GBV_ILN_250 | ||
912 | |a GBV_ILN_267 | ||
912 | |a GBV_ILN_281 | ||
912 | |a GBV_ILN_285 | ||
912 | |a GBV_ILN_293 | ||
912 | |a GBV_ILN_370 | ||
912 | |a GBV_ILN_602 | ||
912 | |a GBV_ILN_636 | ||
912 | |a GBV_ILN_702 | ||
912 | |a GBV_ILN_711 | ||
912 | |a GBV_ILN_2001 | ||
912 | |a GBV_ILN_2003 | ||
912 | |a GBV_ILN_2004 | ||
912 | |a GBV_ILN_2005 | ||
912 | |a GBV_ILN_2006 | ||
912 | |a GBV_ILN_2007 | ||
912 | |a GBV_ILN_2008 | ||
912 | |a GBV_ILN_2009 | ||
912 | |a GBV_ILN_2010 | ||
912 | |a GBV_ILN_2011 | ||
912 | |a GBV_ILN_2014 | ||
912 | |a GBV_ILN_2015 | ||
912 | |a GBV_ILN_2020 | ||
912 | |a GBV_ILN_2021 | ||
912 | |a GBV_ILN_2025 | ||
912 | |a GBV_ILN_2026 | ||
912 | |a GBV_ILN_2027 | ||
912 | |a GBV_ILN_2031 | ||
912 | |a GBV_ILN_2034 | ||
912 | |a GBV_ILN_2037 | ||
912 | |a GBV_ILN_2038 | ||
912 | |a GBV_ILN_2039 | ||
912 | |a GBV_ILN_2044 | ||
912 | |a GBV_ILN_2048 | ||
912 | |a GBV_ILN_2049 | ||
912 | |a GBV_ILN_2050 | ||
912 | |a GBV_ILN_2055 | ||
912 | |a GBV_ILN_2057 | ||
912 | |a GBV_ILN_2059 | ||
912 | |a GBV_ILN_2061 | ||
912 | |a GBV_ILN_2064 | ||
912 | |a GBV_ILN_2065 | ||
912 | |a GBV_ILN_2068 | ||
912 | |a GBV_ILN_2070 | ||
912 | |a GBV_ILN_2086 | ||
912 | |a GBV_ILN_2088 | ||
912 | |a GBV_ILN_2093 | ||
912 | |a GBV_ILN_2106 | ||
912 | |a GBV_ILN_2107 | ||
912 | |a GBV_ILN_2108 | ||
912 | |a GBV_ILN_2110 | ||
912 | |a GBV_ILN_2111 | ||
912 | |a GBV_ILN_2112 | ||
912 | |a GBV_ILN_2113 | ||
912 | |a GBV_ILN_2116 | ||
912 | |a GBV_ILN_2118 | ||
912 | |a GBV_ILN_2119 | ||
912 | |a GBV_ILN_2122 | ||
912 | |a GBV_ILN_2129 | ||
912 | |a GBV_ILN_2143 | ||
912 | |a GBV_ILN_2144 | ||
912 | |a GBV_ILN_2147 | ||
912 | |a GBV_ILN_2148 | ||
912 | |a GBV_ILN_2152 | ||
912 | |a GBV_ILN_2153 | ||
912 | |a GBV_ILN_2188 | ||
912 | |a GBV_ILN_2190 | ||
912 | |a GBV_ILN_2232 | ||
912 | |a GBV_ILN_2336 | ||
912 | |a GBV_ILN_2446 | ||
912 | |a GBV_ILN_2470 | ||
912 | |a GBV_ILN_2472 | ||
912 | |a GBV_ILN_2507 | ||
912 | |a GBV_ILN_2522 | ||
912 | |a GBV_ILN_2548 | ||
912 | |a GBV_ILN_4012 | ||
912 | |a GBV_ILN_4035 | ||
912 | |a GBV_ILN_4037 | ||
912 | |a GBV_ILN_4046 | ||
912 | |a GBV_ILN_4112 | ||
912 | |a GBV_ILN_4125 | ||
912 | |a GBV_ILN_4126 | ||
912 | |a GBV_ILN_4242 | ||
912 | |a GBV_ILN_4246 | ||
912 | |a GBV_ILN_4249 | ||
912 | |a GBV_ILN_4251 | ||
912 | |a GBV_ILN_4305 | ||
912 | |a GBV_ILN_4306 | ||
912 | |a GBV_ILN_4307 | ||
912 | |a GBV_ILN_4313 | ||
912 | |a GBV_ILN_4322 | ||
912 | |a GBV_ILN_4323 | ||
912 | |a GBV_ILN_4324 | ||
912 | |a GBV_ILN_4325 | ||
912 | |a GBV_ILN_4326 | ||
912 | |a GBV_ILN_4328 | ||
912 | |a GBV_ILN_4333 | ||
912 | |a GBV_ILN_4334 | ||
912 | |a GBV_ILN_4335 | ||
912 | |a GBV_ILN_4336 | ||
912 | |a GBV_ILN_4338 | ||
912 | |a GBV_ILN_4393 | ||
912 | |a GBV_ILN_4700 | ||
936 | b | k | |a 44.94 |q ASE |
951 | |a AR | ||
952 | |d 276 |j 2018 |e 3 |b 13 |c 12 |h 631-645 |
author_variant |
k w kw a g ag h e g he heg m l h mlh k g kg |
---|---|
matchkey_str |
article:14344726:2018----::sseairveocretehdlgohgrsltopaygamnm |
hierarchy_sort_str |
2018 |
bklnumber |
44.94 |
publishDate |
2018 |
allfields |
10.1007/s00405-018-5240-9 doi (DE-627)SPR005217199 (SPR)s00405-018-5240-9-e DE-627 ger DE-627 rakwb eng 610 ASE 44.94 bkl Winiker, Katharina verfasserin aut A systematic review of current methodology of high resolution pharyngeal manometry with and without impedance 2018 Text txt rdacontent Computermedien c rdamedia Online-Ressource cr rdacarrier Purpose This systematic review appraises and summaries methodology documented in studies using high resolution pharyngeal manometry (HRM) with and without impedance technology (HRIM) in adult populations. Methods Four electronic databases CINAHL, EMBASE, MEDLINE, and Cochrane Library were searched up to, and including March 2017. Studies reporting pharyngeal HRM/HRIM for swallowing and/or phonatory assessment, published in peer-reviewed journals in English, German, or Spanish were assessed for the inclusion criteria. Of the selected studies, methodological aspects of data acquisition and analysis were extracted. Publications were graded based on their level of evidence and quality of methodological aspects was assessed. Results Sixty-two articles were identified eligible, from which 50 studies reported the use of HRM and 12 studies used HRIM. Of all included manuscripts, the majority utilized the ManoScan™ system (64.5%), a catheter diameter of 4.2 mm was most prevalently documented (30.6%). Most publications reported the application of topical anesthesia (53.2%). For data analysis in studies using HRM, software intrinsic to the recording system was reported most frequently (56%). A minority of the studies using HRM provided data about measurement reliability (10%). This is higher for studies using HRIM (50%). Conclusions Considerable methodological variability exists regarding data acquisition and analysis in published studies using HRM/HRIM. Lacking reports of methodology make study replications difficult and reduce the comparability across studies. More data regarding the impact of individual methodological aspects on study outcomes are further required for the development of methodological recommendations. Deglutition (dpeaa)DE-He213 Manometry (dpeaa)DE-He213 High resolution manometry (dpeaa)DE-He213 Impedance (dpeaa)DE-He213 Gillman, Anna verfasserin aut Guiu Hernandez, Esther verfasserin aut Huckabee, Maggie-Lee verfasserin aut Gozdzikowska, Kristin verfasserin aut Enthalten in European archives of oto-rhino-laryngology and head & neck Berlin : Springer, 1864 276(2018), 3 vom: 13. Dez., Seite 631-645 (DE-627)253722667 (DE-600)1459042-6 1434-4726 nnns volume:276 year:2018 number:3 day:13 month:12 pages:631-645 https://dx.doi.org/10.1007/s00405-018-5240-9 lizenzpflichtig Volltext GBV_USEFLAG_A SYSFLAG_A GBV_SPRINGER SSG-OLC-PHA GBV_ILN_11 GBV_ILN_20 GBV_ILN_22 GBV_ILN_23 GBV_ILN_24 GBV_ILN_31 GBV_ILN_32 GBV_ILN_39 GBV_ILN_40 GBV_ILN_60 GBV_ILN_62 GBV_ILN_63 GBV_ILN_65 GBV_ILN_69 GBV_ILN_70 GBV_ILN_73 GBV_ILN_74 GBV_ILN_90 GBV_ILN_95 GBV_ILN_100 GBV_ILN_101 GBV_ILN_105 GBV_ILN_110 GBV_ILN_120 GBV_ILN_138 GBV_ILN_150 GBV_ILN_151 GBV_ILN_152 GBV_ILN_161 GBV_ILN_170 GBV_ILN_171 GBV_ILN_187 GBV_ILN_213 GBV_ILN_224 GBV_ILN_230 GBV_ILN_250 GBV_ILN_267 GBV_ILN_281 GBV_ILN_285 GBV_ILN_293 GBV_ILN_370 GBV_ILN_602 GBV_ILN_636 GBV_ILN_702 GBV_ILN_711 GBV_ILN_2001 GBV_ILN_2003 GBV_ILN_2004 GBV_ILN_2005 GBV_ILN_2006 GBV_ILN_2007 GBV_ILN_2008 GBV_ILN_2009 GBV_ILN_2010 GBV_ILN_2011 GBV_ILN_2014 GBV_ILN_2015 GBV_ILN_2020 GBV_ILN_2021 GBV_ILN_2025 GBV_ILN_2026 GBV_ILN_2027 GBV_ILN_2031 GBV_ILN_2034 GBV_ILN_2037 GBV_ILN_2038 GBV_ILN_2039 GBV_ILN_2044 GBV_ILN_2048 GBV_ILN_2049 GBV_ILN_2050 GBV_ILN_2055 GBV_ILN_2057 GBV_ILN_2059 GBV_ILN_2061 GBV_ILN_2064 GBV_ILN_2065 GBV_ILN_2068 GBV_ILN_2070 GBV_ILN_2086 GBV_ILN_2088 GBV_ILN_2093 GBV_ILN_2106 GBV_ILN_2107 GBV_ILN_2108 GBV_ILN_2110 GBV_ILN_2111 GBV_ILN_2112 GBV_ILN_2113 GBV_ILN_2116 GBV_ILN_2118 GBV_ILN_2119 GBV_ILN_2122 GBV_ILN_2129 GBV_ILN_2143 GBV_ILN_2144 GBV_ILN_2147 GBV_ILN_2148 GBV_ILN_2152 GBV_ILN_2153 GBV_ILN_2188 GBV_ILN_2190 GBV_ILN_2232 GBV_ILN_2336 GBV_ILN_2446 GBV_ILN_2470 GBV_ILN_2472 GBV_ILN_2507 GBV_ILN_2522 GBV_ILN_2548 GBV_ILN_4012 GBV_ILN_4035 GBV_ILN_4037 GBV_ILN_4046 GBV_ILN_4112 GBV_ILN_4125 GBV_ILN_4126 GBV_ILN_4242 GBV_ILN_4246 GBV_ILN_4249 GBV_ILN_4251 GBV_ILN_4305 GBV_ILN_4306 GBV_ILN_4307 GBV_ILN_4313 GBV_ILN_4322 GBV_ILN_4323 GBV_ILN_4324 GBV_ILN_4325 GBV_ILN_4326 GBV_ILN_4328 GBV_ILN_4333 GBV_ILN_4334 GBV_ILN_4335 GBV_ILN_4336 GBV_ILN_4338 GBV_ILN_4393 GBV_ILN_4700 44.94 ASE AR 276 2018 3 13 12 631-645 |
spelling |
10.1007/s00405-018-5240-9 doi (DE-627)SPR005217199 (SPR)s00405-018-5240-9-e DE-627 ger DE-627 rakwb eng 610 ASE 44.94 bkl Winiker, Katharina verfasserin aut A systematic review of current methodology of high resolution pharyngeal manometry with and without impedance 2018 Text txt rdacontent Computermedien c rdamedia Online-Ressource cr rdacarrier Purpose This systematic review appraises and summaries methodology documented in studies using high resolution pharyngeal manometry (HRM) with and without impedance technology (HRIM) in adult populations. Methods Four electronic databases CINAHL, EMBASE, MEDLINE, and Cochrane Library were searched up to, and including March 2017. Studies reporting pharyngeal HRM/HRIM for swallowing and/or phonatory assessment, published in peer-reviewed journals in English, German, or Spanish were assessed for the inclusion criteria. Of the selected studies, methodological aspects of data acquisition and analysis were extracted. Publications were graded based on their level of evidence and quality of methodological aspects was assessed. Results Sixty-two articles were identified eligible, from which 50 studies reported the use of HRM and 12 studies used HRIM. Of all included manuscripts, the majority utilized the ManoScan™ system (64.5%), a catheter diameter of 4.2 mm was most prevalently documented (30.6%). Most publications reported the application of topical anesthesia (53.2%). For data analysis in studies using HRM, software intrinsic to the recording system was reported most frequently (56%). A minority of the studies using HRM provided data about measurement reliability (10%). This is higher for studies using HRIM (50%). Conclusions Considerable methodological variability exists regarding data acquisition and analysis in published studies using HRM/HRIM. Lacking reports of methodology make study replications difficult and reduce the comparability across studies. More data regarding the impact of individual methodological aspects on study outcomes are further required for the development of methodological recommendations. Deglutition (dpeaa)DE-He213 Manometry (dpeaa)DE-He213 High resolution manometry (dpeaa)DE-He213 Impedance (dpeaa)DE-He213 Gillman, Anna verfasserin aut Guiu Hernandez, Esther verfasserin aut Huckabee, Maggie-Lee verfasserin aut Gozdzikowska, Kristin verfasserin aut Enthalten in European archives of oto-rhino-laryngology and head & neck Berlin : Springer, 1864 276(2018), 3 vom: 13. Dez., Seite 631-645 (DE-627)253722667 (DE-600)1459042-6 1434-4726 nnns volume:276 year:2018 number:3 day:13 month:12 pages:631-645 https://dx.doi.org/10.1007/s00405-018-5240-9 lizenzpflichtig Volltext GBV_USEFLAG_A SYSFLAG_A GBV_SPRINGER SSG-OLC-PHA GBV_ILN_11 GBV_ILN_20 GBV_ILN_22 GBV_ILN_23 GBV_ILN_24 GBV_ILN_31 GBV_ILN_32 GBV_ILN_39 GBV_ILN_40 GBV_ILN_60 GBV_ILN_62 GBV_ILN_63 GBV_ILN_65 GBV_ILN_69 GBV_ILN_70 GBV_ILN_73 GBV_ILN_74 GBV_ILN_90 GBV_ILN_95 GBV_ILN_100 GBV_ILN_101 GBV_ILN_105 GBV_ILN_110 GBV_ILN_120 GBV_ILN_138 GBV_ILN_150 GBV_ILN_151 GBV_ILN_152 GBV_ILN_161 GBV_ILN_170 GBV_ILN_171 GBV_ILN_187 GBV_ILN_213 GBV_ILN_224 GBV_ILN_230 GBV_ILN_250 GBV_ILN_267 GBV_ILN_281 GBV_ILN_285 GBV_ILN_293 GBV_ILN_370 GBV_ILN_602 GBV_ILN_636 GBV_ILN_702 GBV_ILN_711 GBV_ILN_2001 GBV_ILN_2003 GBV_ILN_2004 GBV_ILN_2005 GBV_ILN_2006 GBV_ILN_2007 GBV_ILN_2008 GBV_ILN_2009 GBV_ILN_2010 GBV_ILN_2011 GBV_ILN_2014 GBV_ILN_2015 GBV_ILN_2020 GBV_ILN_2021 GBV_ILN_2025 GBV_ILN_2026 GBV_ILN_2027 GBV_ILN_2031 GBV_ILN_2034 GBV_ILN_2037 GBV_ILN_2038 GBV_ILN_2039 GBV_ILN_2044 GBV_ILN_2048 GBV_ILN_2049 GBV_ILN_2050 GBV_ILN_2055 GBV_ILN_2057 GBV_ILN_2059 GBV_ILN_2061 GBV_ILN_2064 GBV_ILN_2065 GBV_ILN_2068 GBV_ILN_2070 GBV_ILN_2086 GBV_ILN_2088 GBV_ILN_2093 GBV_ILN_2106 GBV_ILN_2107 GBV_ILN_2108 GBV_ILN_2110 GBV_ILN_2111 GBV_ILN_2112 GBV_ILN_2113 GBV_ILN_2116 GBV_ILN_2118 GBV_ILN_2119 GBV_ILN_2122 GBV_ILN_2129 GBV_ILN_2143 GBV_ILN_2144 GBV_ILN_2147 GBV_ILN_2148 GBV_ILN_2152 GBV_ILN_2153 GBV_ILN_2188 GBV_ILN_2190 GBV_ILN_2232 GBV_ILN_2336 GBV_ILN_2446 GBV_ILN_2470 GBV_ILN_2472 GBV_ILN_2507 GBV_ILN_2522 GBV_ILN_2548 GBV_ILN_4012 GBV_ILN_4035 GBV_ILN_4037 GBV_ILN_4046 GBV_ILN_4112 GBV_ILN_4125 GBV_ILN_4126 GBV_ILN_4242 GBV_ILN_4246 GBV_ILN_4249 GBV_ILN_4251 GBV_ILN_4305 GBV_ILN_4306 GBV_ILN_4307 GBV_ILN_4313 GBV_ILN_4322 GBV_ILN_4323 GBV_ILN_4324 GBV_ILN_4325 GBV_ILN_4326 GBV_ILN_4328 GBV_ILN_4333 GBV_ILN_4334 GBV_ILN_4335 GBV_ILN_4336 GBV_ILN_4338 GBV_ILN_4393 GBV_ILN_4700 44.94 ASE AR 276 2018 3 13 12 631-645 |
allfields_unstemmed |
10.1007/s00405-018-5240-9 doi (DE-627)SPR005217199 (SPR)s00405-018-5240-9-e DE-627 ger DE-627 rakwb eng 610 ASE 44.94 bkl Winiker, Katharina verfasserin aut A systematic review of current methodology of high resolution pharyngeal manometry with and without impedance 2018 Text txt rdacontent Computermedien c rdamedia Online-Ressource cr rdacarrier Purpose This systematic review appraises and summaries methodology documented in studies using high resolution pharyngeal manometry (HRM) with and without impedance technology (HRIM) in adult populations. Methods Four electronic databases CINAHL, EMBASE, MEDLINE, and Cochrane Library were searched up to, and including March 2017. Studies reporting pharyngeal HRM/HRIM for swallowing and/or phonatory assessment, published in peer-reviewed journals in English, German, or Spanish were assessed for the inclusion criteria. Of the selected studies, methodological aspects of data acquisition and analysis were extracted. Publications were graded based on their level of evidence and quality of methodological aspects was assessed. Results Sixty-two articles were identified eligible, from which 50 studies reported the use of HRM and 12 studies used HRIM. Of all included manuscripts, the majority utilized the ManoScan™ system (64.5%), a catheter diameter of 4.2 mm was most prevalently documented (30.6%). Most publications reported the application of topical anesthesia (53.2%). For data analysis in studies using HRM, software intrinsic to the recording system was reported most frequently (56%). A minority of the studies using HRM provided data about measurement reliability (10%). This is higher for studies using HRIM (50%). Conclusions Considerable methodological variability exists regarding data acquisition and analysis in published studies using HRM/HRIM. Lacking reports of methodology make study replications difficult and reduce the comparability across studies. More data regarding the impact of individual methodological aspects on study outcomes are further required for the development of methodological recommendations. Deglutition (dpeaa)DE-He213 Manometry (dpeaa)DE-He213 High resolution manometry (dpeaa)DE-He213 Impedance (dpeaa)DE-He213 Gillman, Anna verfasserin aut Guiu Hernandez, Esther verfasserin aut Huckabee, Maggie-Lee verfasserin aut Gozdzikowska, Kristin verfasserin aut Enthalten in European archives of oto-rhino-laryngology and head & neck Berlin : Springer, 1864 276(2018), 3 vom: 13. Dez., Seite 631-645 (DE-627)253722667 (DE-600)1459042-6 1434-4726 nnns volume:276 year:2018 number:3 day:13 month:12 pages:631-645 https://dx.doi.org/10.1007/s00405-018-5240-9 lizenzpflichtig Volltext GBV_USEFLAG_A SYSFLAG_A GBV_SPRINGER SSG-OLC-PHA GBV_ILN_11 GBV_ILN_20 GBV_ILN_22 GBV_ILN_23 GBV_ILN_24 GBV_ILN_31 GBV_ILN_32 GBV_ILN_39 GBV_ILN_40 GBV_ILN_60 GBV_ILN_62 GBV_ILN_63 GBV_ILN_65 GBV_ILN_69 GBV_ILN_70 GBV_ILN_73 GBV_ILN_74 GBV_ILN_90 GBV_ILN_95 GBV_ILN_100 GBV_ILN_101 GBV_ILN_105 GBV_ILN_110 GBV_ILN_120 GBV_ILN_138 GBV_ILN_150 GBV_ILN_151 GBV_ILN_152 GBV_ILN_161 GBV_ILN_170 GBV_ILN_171 GBV_ILN_187 GBV_ILN_213 GBV_ILN_224 GBV_ILN_230 GBV_ILN_250 GBV_ILN_267 GBV_ILN_281 GBV_ILN_285 GBV_ILN_293 GBV_ILN_370 GBV_ILN_602 GBV_ILN_636 GBV_ILN_702 GBV_ILN_711 GBV_ILN_2001 GBV_ILN_2003 GBV_ILN_2004 GBV_ILN_2005 GBV_ILN_2006 GBV_ILN_2007 GBV_ILN_2008 GBV_ILN_2009 GBV_ILN_2010 GBV_ILN_2011 GBV_ILN_2014 GBV_ILN_2015 GBV_ILN_2020 GBV_ILN_2021 GBV_ILN_2025 GBV_ILN_2026 GBV_ILN_2027 GBV_ILN_2031 GBV_ILN_2034 GBV_ILN_2037 GBV_ILN_2038 GBV_ILN_2039 GBV_ILN_2044 GBV_ILN_2048 GBV_ILN_2049 GBV_ILN_2050 GBV_ILN_2055 GBV_ILN_2057 GBV_ILN_2059 GBV_ILN_2061 GBV_ILN_2064 GBV_ILN_2065 GBV_ILN_2068 GBV_ILN_2070 GBV_ILN_2086 GBV_ILN_2088 GBV_ILN_2093 GBV_ILN_2106 GBV_ILN_2107 GBV_ILN_2108 GBV_ILN_2110 GBV_ILN_2111 GBV_ILN_2112 GBV_ILN_2113 GBV_ILN_2116 GBV_ILN_2118 GBV_ILN_2119 GBV_ILN_2122 GBV_ILN_2129 GBV_ILN_2143 GBV_ILN_2144 GBV_ILN_2147 GBV_ILN_2148 GBV_ILN_2152 GBV_ILN_2153 GBV_ILN_2188 GBV_ILN_2190 GBV_ILN_2232 GBV_ILN_2336 GBV_ILN_2446 GBV_ILN_2470 GBV_ILN_2472 GBV_ILN_2507 GBV_ILN_2522 GBV_ILN_2548 GBV_ILN_4012 GBV_ILN_4035 GBV_ILN_4037 GBV_ILN_4046 GBV_ILN_4112 GBV_ILN_4125 GBV_ILN_4126 GBV_ILN_4242 GBV_ILN_4246 GBV_ILN_4249 GBV_ILN_4251 GBV_ILN_4305 GBV_ILN_4306 GBV_ILN_4307 GBV_ILN_4313 GBV_ILN_4322 GBV_ILN_4323 GBV_ILN_4324 GBV_ILN_4325 GBV_ILN_4326 GBV_ILN_4328 GBV_ILN_4333 GBV_ILN_4334 GBV_ILN_4335 GBV_ILN_4336 GBV_ILN_4338 GBV_ILN_4393 GBV_ILN_4700 44.94 ASE AR 276 2018 3 13 12 631-645 |
allfieldsGer |
10.1007/s00405-018-5240-9 doi (DE-627)SPR005217199 (SPR)s00405-018-5240-9-e DE-627 ger DE-627 rakwb eng 610 ASE 44.94 bkl Winiker, Katharina verfasserin aut A systematic review of current methodology of high resolution pharyngeal manometry with and without impedance 2018 Text txt rdacontent Computermedien c rdamedia Online-Ressource cr rdacarrier Purpose This systematic review appraises and summaries methodology documented in studies using high resolution pharyngeal manometry (HRM) with and without impedance technology (HRIM) in adult populations. Methods Four electronic databases CINAHL, EMBASE, MEDLINE, and Cochrane Library were searched up to, and including March 2017. Studies reporting pharyngeal HRM/HRIM for swallowing and/or phonatory assessment, published in peer-reviewed journals in English, German, or Spanish were assessed for the inclusion criteria. Of the selected studies, methodological aspects of data acquisition and analysis were extracted. Publications were graded based on their level of evidence and quality of methodological aspects was assessed. Results Sixty-two articles were identified eligible, from which 50 studies reported the use of HRM and 12 studies used HRIM. Of all included manuscripts, the majority utilized the ManoScan™ system (64.5%), a catheter diameter of 4.2 mm was most prevalently documented (30.6%). Most publications reported the application of topical anesthesia (53.2%). For data analysis in studies using HRM, software intrinsic to the recording system was reported most frequently (56%). A minority of the studies using HRM provided data about measurement reliability (10%). This is higher for studies using HRIM (50%). Conclusions Considerable methodological variability exists regarding data acquisition and analysis in published studies using HRM/HRIM. Lacking reports of methodology make study replications difficult and reduce the comparability across studies. More data regarding the impact of individual methodological aspects on study outcomes are further required for the development of methodological recommendations. Deglutition (dpeaa)DE-He213 Manometry (dpeaa)DE-He213 High resolution manometry (dpeaa)DE-He213 Impedance (dpeaa)DE-He213 Gillman, Anna verfasserin aut Guiu Hernandez, Esther verfasserin aut Huckabee, Maggie-Lee verfasserin aut Gozdzikowska, Kristin verfasserin aut Enthalten in European archives of oto-rhino-laryngology and head & neck Berlin : Springer, 1864 276(2018), 3 vom: 13. Dez., Seite 631-645 (DE-627)253722667 (DE-600)1459042-6 1434-4726 nnns volume:276 year:2018 number:3 day:13 month:12 pages:631-645 https://dx.doi.org/10.1007/s00405-018-5240-9 lizenzpflichtig Volltext GBV_USEFLAG_A SYSFLAG_A GBV_SPRINGER SSG-OLC-PHA GBV_ILN_11 GBV_ILN_20 GBV_ILN_22 GBV_ILN_23 GBV_ILN_24 GBV_ILN_31 GBV_ILN_32 GBV_ILN_39 GBV_ILN_40 GBV_ILN_60 GBV_ILN_62 GBV_ILN_63 GBV_ILN_65 GBV_ILN_69 GBV_ILN_70 GBV_ILN_73 GBV_ILN_74 GBV_ILN_90 GBV_ILN_95 GBV_ILN_100 GBV_ILN_101 GBV_ILN_105 GBV_ILN_110 GBV_ILN_120 GBV_ILN_138 GBV_ILN_150 GBV_ILN_151 GBV_ILN_152 GBV_ILN_161 GBV_ILN_170 GBV_ILN_171 GBV_ILN_187 GBV_ILN_213 GBV_ILN_224 GBV_ILN_230 GBV_ILN_250 GBV_ILN_267 GBV_ILN_281 GBV_ILN_285 GBV_ILN_293 GBV_ILN_370 GBV_ILN_602 GBV_ILN_636 GBV_ILN_702 GBV_ILN_711 GBV_ILN_2001 GBV_ILN_2003 GBV_ILN_2004 GBV_ILN_2005 GBV_ILN_2006 GBV_ILN_2007 GBV_ILN_2008 GBV_ILN_2009 GBV_ILN_2010 GBV_ILN_2011 GBV_ILN_2014 GBV_ILN_2015 GBV_ILN_2020 GBV_ILN_2021 GBV_ILN_2025 GBV_ILN_2026 GBV_ILN_2027 GBV_ILN_2031 GBV_ILN_2034 GBV_ILN_2037 GBV_ILN_2038 GBV_ILN_2039 GBV_ILN_2044 GBV_ILN_2048 GBV_ILN_2049 GBV_ILN_2050 GBV_ILN_2055 GBV_ILN_2057 GBV_ILN_2059 GBV_ILN_2061 GBV_ILN_2064 GBV_ILN_2065 GBV_ILN_2068 GBV_ILN_2070 GBV_ILN_2086 GBV_ILN_2088 GBV_ILN_2093 GBV_ILN_2106 GBV_ILN_2107 GBV_ILN_2108 GBV_ILN_2110 GBV_ILN_2111 GBV_ILN_2112 GBV_ILN_2113 GBV_ILN_2116 GBV_ILN_2118 GBV_ILN_2119 GBV_ILN_2122 GBV_ILN_2129 GBV_ILN_2143 GBV_ILN_2144 GBV_ILN_2147 GBV_ILN_2148 GBV_ILN_2152 GBV_ILN_2153 GBV_ILN_2188 GBV_ILN_2190 GBV_ILN_2232 GBV_ILN_2336 GBV_ILN_2446 GBV_ILN_2470 GBV_ILN_2472 GBV_ILN_2507 GBV_ILN_2522 GBV_ILN_2548 GBV_ILN_4012 GBV_ILN_4035 GBV_ILN_4037 GBV_ILN_4046 GBV_ILN_4112 GBV_ILN_4125 GBV_ILN_4126 GBV_ILN_4242 GBV_ILN_4246 GBV_ILN_4249 GBV_ILN_4251 GBV_ILN_4305 GBV_ILN_4306 GBV_ILN_4307 GBV_ILN_4313 GBV_ILN_4322 GBV_ILN_4323 GBV_ILN_4324 GBV_ILN_4325 GBV_ILN_4326 GBV_ILN_4328 GBV_ILN_4333 GBV_ILN_4334 GBV_ILN_4335 GBV_ILN_4336 GBV_ILN_4338 GBV_ILN_4393 GBV_ILN_4700 44.94 ASE AR 276 2018 3 13 12 631-645 |
allfieldsSound |
10.1007/s00405-018-5240-9 doi (DE-627)SPR005217199 (SPR)s00405-018-5240-9-e DE-627 ger DE-627 rakwb eng 610 ASE 44.94 bkl Winiker, Katharina verfasserin aut A systematic review of current methodology of high resolution pharyngeal manometry with and without impedance 2018 Text txt rdacontent Computermedien c rdamedia Online-Ressource cr rdacarrier Purpose This systematic review appraises and summaries methodology documented in studies using high resolution pharyngeal manometry (HRM) with and without impedance technology (HRIM) in adult populations. Methods Four electronic databases CINAHL, EMBASE, MEDLINE, and Cochrane Library were searched up to, and including March 2017. Studies reporting pharyngeal HRM/HRIM for swallowing and/or phonatory assessment, published in peer-reviewed journals in English, German, or Spanish were assessed for the inclusion criteria. Of the selected studies, methodological aspects of data acquisition and analysis were extracted. Publications were graded based on their level of evidence and quality of methodological aspects was assessed. Results Sixty-two articles were identified eligible, from which 50 studies reported the use of HRM and 12 studies used HRIM. Of all included manuscripts, the majority utilized the ManoScan™ system (64.5%), a catheter diameter of 4.2 mm was most prevalently documented (30.6%). Most publications reported the application of topical anesthesia (53.2%). For data analysis in studies using HRM, software intrinsic to the recording system was reported most frequently (56%). A minority of the studies using HRM provided data about measurement reliability (10%). This is higher for studies using HRIM (50%). Conclusions Considerable methodological variability exists regarding data acquisition and analysis in published studies using HRM/HRIM. Lacking reports of methodology make study replications difficult and reduce the comparability across studies. More data regarding the impact of individual methodological aspects on study outcomes are further required for the development of methodological recommendations. Deglutition (dpeaa)DE-He213 Manometry (dpeaa)DE-He213 High resolution manometry (dpeaa)DE-He213 Impedance (dpeaa)DE-He213 Gillman, Anna verfasserin aut Guiu Hernandez, Esther verfasserin aut Huckabee, Maggie-Lee verfasserin aut Gozdzikowska, Kristin verfasserin aut Enthalten in European archives of oto-rhino-laryngology and head & neck Berlin : Springer, 1864 276(2018), 3 vom: 13. Dez., Seite 631-645 (DE-627)253722667 (DE-600)1459042-6 1434-4726 nnns volume:276 year:2018 number:3 day:13 month:12 pages:631-645 https://dx.doi.org/10.1007/s00405-018-5240-9 lizenzpflichtig Volltext GBV_USEFLAG_A SYSFLAG_A GBV_SPRINGER SSG-OLC-PHA GBV_ILN_11 GBV_ILN_20 GBV_ILN_22 GBV_ILN_23 GBV_ILN_24 GBV_ILN_31 GBV_ILN_32 GBV_ILN_39 GBV_ILN_40 GBV_ILN_60 GBV_ILN_62 GBV_ILN_63 GBV_ILN_65 GBV_ILN_69 GBV_ILN_70 GBV_ILN_73 GBV_ILN_74 GBV_ILN_90 GBV_ILN_95 GBV_ILN_100 GBV_ILN_101 GBV_ILN_105 GBV_ILN_110 GBV_ILN_120 GBV_ILN_138 GBV_ILN_150 GBV_ILN_151 GBV_ILN_152 GBV_ILN_161 GBV_ILN_170 GBV_ILN_171 GBV_ILN_187 GBV_ILN_213 GBV_ILN_224 GBV_ILN_230 GBV_ILN_250 GBV_ILN_267 GBV_ILN_281 GBV_ILN_285 GBV_ILN_293 GBV_ILN_370 GBV_ILN_602 GBV_ILN_636 GBV_ILN_702 GBV_ILN_711 GBV_ILN_2001 GBV_ILN_2003 GBV_ILN_2004 GBV_ILN_2005 GBV_ILN_2006 GBV_ILN_2007 GBV_ILN_2008 GBV_ILN_2009 GBV_ILN_2010 GBV_ILN_2011 GBV_ILN_2014 GBV_ILN_2015 GBV_ILN_2020 GBV_ILN_2021 GBV_ILN_2025 GBV_ILN_2026 GBV_ILN_2027 GBV_ILN_2031 GBV_ILN_2034 GBV_ILN_2037 GBV_ILN_2038 GBV_ILN_2039 GBV_ILN_2044 GBV_ILN_2048 GBV_ILN_2049 GBV_ILN_2050 GBV_ILN_2055 GBV_ILN_2057 GBV_ILN_2059 GBV_ILN_2061 GBV_ILN_2064 GBV_ILN_2065 GBV_ILN_2068 GBV_ILN_2070 GBV_ILN_2086 GBV_ILN_2088 GBV_ILN_2093 GBV_ILN_2106 GBV_ILN_2107 GBV_ILN_2108 GBV_ILN_2110 GBV_ILN_2111 GBV_ILN_2112 GBV_ILN_2113 GBV_ILN_2116 GBV_ILN_2118 GBV_ILN_2119 GBV_ILN_2122 GBV_ILN_2129 GBV_ILN_2143 GBV_ILN_2144 GBV_ILN_2147 GBV_ILN_2148 GBV_ILN_2152 GBV_ILN_2153 GBV_ILN_2188 GBV_ILN_2190 GBV_ILN_2232 GBV_ILN_2336 GBV_ILN_2446 GBV_ILN_2470 GBV_ILN_2472 GBV_ILN_2507 GBV_ILN_2522 GBV_ILN_2548 GBV_ILN_4012 GBV_ILN_4035 GBV_ILN_4037 GBV_ILN_4046 GBV_ILN_4112 GBV_ILN_4125 GBV_ILN_4126 GBV_ILN_4242 GBV_ILN_4246 GBV_ILN_4249 GBV_ILN_4251 GBV_ILN_4305 GBV_ILN_4306 GBV_ILN_4307 GBV_ILN_4313 GBV_ILN_4322 GBV_ILN_4323 GBV_ILN_4324 GBV_ILN_4325 GBV_ILN_4326 GBV_ILN_4328 GBV_ILN_4333 GBV_ILN_4334 GBV_ILN_4335 GBV_ILN_4336 GBV_ILN_4338 GBV_ILN_4393 GBV_ILN_4700 44.94 ASE AR 276 2018 3 13 12 631-645 |
language |
English |
source |
Enthalten in European archives of oto-rhino-laryngology and head & neck 276(2018), 3 vom: 13. Dez., Seite 631-645 volume:276 year:2018 number:3 day:13 month:12 pages:631-645 |
sourceStr |
Enthalten in European archives of oto-rhino-laryngology and head & neck 276(2018), 3 vom: 13. Dez., Seite 631-645 volume:276 year:2018 number:3 day:13 month:12 pages:631-645 |
format_phy_str_mv |
Article |
institution |
findex.gbv.de |
topic_facet |
Deglutition Manometry High resolution manometry Impedance |
dewey-raw |
610 |
isfreeaccess_bool |
false |
container_title |
European archives of oto-rhino-laryngology and head & neck |
authorswithroles_txt_mv |
Winiker, Katharina @@aut@@ Gillman, Anna @@aut@@ Guiu Hernandez, Esther @@aut@@ Huckabee, Maggie-Lee @@aut@@ Gozdzikowska, Kristin @@aut@@ |
publishDateDaySort_date |
2018-12-13T00:00:00Z |
hierarchy_top_id |
253722667 |
dewey-sort |
3610 |
id |
SPR005217199 |
language_de |
englisch |
fullrecord |
<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim"><record><leader>01000caa a22002652 4500</leader><controlfield tag="001">SPR005217199</controlfield><controlfield tag="003">DE-627</controlfield><controlfield tag="005">20230520000758.0</controlfield><controlfield tag="007">cr uuu---uuuuu</controlfield><controlfield tag="008">201001s2018 xx |||||o 00| ||eng c</controlfield><datafield tag="024" ind1="7" ind2=" "><subfield code="a">10.1007/s00405-018-5240-9</subfield><subfield code="2">doi</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-627)SPR005217199</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(SPR)s00405-018-5240-9-e</subfield></datafield><datafield tag="040" ind1=" " ind2=" "><subfield code="a">DE-627</subfield><subfield code="b">ger</subfield><subfield code="c">DE-627</subfield><subfield code="e">rakwb</subfield></datafield><datafield tag="041" ind1=" " ind2=" "><subfield code="a">eng</subfield></datafield><datafield tag="082" ind1="0" ind2="4"><subfield code="a">610</subfield><subfield code="q">ASE</subfield></datafield><datafield tag="084" ind1=" " ind2=" "><subfield code="a">44.94</subfield><subfield code="2">bkl</subfield></datafield><datafield tag="100" ind1="1" ind2=" "><subfield code="a">Winiker, Katharina</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="245" ind1="1" ind2="2"><subfield code="a">A systematic review of current methodology of high resolution pharyngeal manometry with and without impedance</subfield></datafield><datafield tag="264" ind1=" " ind2="1"><subfield code="c">2018</subfield></datafield><datafield tag="336" ind1=" " ind2=" "><subfield code="a">Text</subfield><subfield code="b">txt</subfield><subfield code="2">rdacontent</subfield></datafield><datafield tag="337" ind1=" " ind2=" "><subfield code="a">Computermedien</subfield><subfield code="b">c</subfield><subfield code="2">rdamedia</subfield></datafield><datafield tag="338" ind1=" " ind2=" "><subfield code="a">Online-Ressource</subfield><subfield code="b">cr</subfield><subfield code="2">rdacarrier</subfield></datafield><datafield tag="520" ind1=" " ind2=" "><subfield code="a">Purpose This systematic review appraises and summaries methodology documented in studies using high resolution pharyngeal manometry (HRM) with and without impedance technology (HRIM) in adult populations. Methods Four electronic databases CINAHL, EMBASE, MEDLINE, and Cochrane Library were searched up to, and including March 2017. Studies reporting pharyngeal HRM/HRIM for swallowing and/or phonatory assessment, published in peer-reviewed journals in English, German, or Spanish were assessed for the inclusion criteria. Of the selected studies, methodological aspects of data acquisition and analysis were extracted. Publications were graded based on their level of evidence and quality of methodological aspects was assessed. Results Sixty-two articles were identified eligible, from which 50 studies reported the use of HRM and 12 studies used HRIM. Of all included manuscripts, the majority utilized the ManoScan™ system (64.5%), a catheter diameter of 4.2 mm was most prevalently documented (30.6%). Most publications reported the application of topical anesthesia (53.2%). For data analysis in studies using HRM, software intrinsic to the recording system was reported most frequently (56%). A minority of the studies using HRM provided data about measurement reliability (10%). This is higher for studies using HRIM (50%). Conclusions Considerable methodological variability exists regarding data acquisition and analysis in published studies using HRM/HRIM. Lacking reports of methodology make study replications difficult and reduce the comparability across studies. More data regarding the impact of individual methodological aspects on study outcomes are further required for the development of methodological recommendations.</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Deglutition</subfield><subfield code="7">(dpeaa)DE-He213</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Manometry</subfield><subfield code="7">(dpeaa)DE-He213</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">High resolution manometry</subfield><subfield code="7">(dpeaa)DE-He213</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Impedance</subfield><subfield code="7">(dpeaa)DE-He213</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Gillman, Anna</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Guiu Hernandez, Esther</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Huckabee, Maggie-Lee</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Gozdzikowska, Kristin</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="773" ind1="0" ind2="8"><subfield code="i">Enthalten in</subfield><subfield code="t">European archives of oto-rhino-laryngology and head & neck</subfield><subfield code="d">Berlin : Springer, 1864</subfield><subfield code="g">276(2018), 3 vom: 13. Dez., Seite 631-645</subfield><subfield code="w">(DE-627)253722667</subfield><subfield code="w">(DE-600)1459042-6</subfield><subfield code="x">1434-4726</subfield><subfield code="7">nnns</subfield></datafield><datafield tag="773" ind1="1" ind2="8"><subfield code="g">volume:276</subfield><subfield code="g">year:2018</subfield><subfield code="g">number:3</subfield><subfield code="g">day:13</subfield><subfield code="g">month:12</subfield><subfield code="g">pages:631-645</subfield></datafield><datafield tag="856" ind1="4" ind2="0"><subfield code="u">https://dx.doi.org/10.1007/s00405-018-5240-9</subfield><subfield code="z">lizenzpflichtig</subfield><subfield code="3">Volltext</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_USEFLAG_A</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">SYSFLAG_A</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_SPRINGER</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">SSG-OLC-PHA</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_11</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_20</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_22</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_23</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_24</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_31</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_32</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_39</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_40</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_60</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_62</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_63</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_65</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_69</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_70</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_73</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_74</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_90</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_95</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_100</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_101</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_105</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_110</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_120</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_138</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_150</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_151</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_152</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_161</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_170</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_171</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_187</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_213</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_224</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_230</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_250</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_267</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_281</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_285</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_293</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_370</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_602</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_636</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_702</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_711</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2001</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2003</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2004</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2005</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2006</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2007</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2008</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2009</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2010</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2011</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2014</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2015</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2020</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2021</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2025</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2026</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2027</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2031</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2034</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2037</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2038</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2039</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2044</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2048</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2049</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2050</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2055</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2057</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2059</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2061</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2064</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2065</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2068</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2070</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2086</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2088</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2093</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2106</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2107</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2108</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2110</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2111</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2112</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2113</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2116</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2118</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2119</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2122</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2129</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2143</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2144</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2147</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2148</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2152</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2153</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2188</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2190</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2232</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2336</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2446</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2470</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2472</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2507</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2522</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2548</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4012</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4035</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4037</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4046</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4112</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4125</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4126</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4242</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4246</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4249</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4251</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4305</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4306</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4307</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4313</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4322</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4323</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4324</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4325</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4326</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4328</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4333</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4334</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4335</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4336</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4338</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4393</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4700</subfield></datafield><datafield tag="936" ind1="b" ind2="k"><subfield code="a">44.94</subfield><subfield code="q">ASE</subfield></datafield><datafield tag="951" ind1=" " ind2=" "><subfield code="a">AR</subfield></datafield><datafield tag="952" ind1=" " ind2=" "><subfield code="d">276</subfield><subfield code="j">2018</subfield><subfield code="e">3</subfield><subfield code="b">13</subfield><subfield code="c">12</subfield><subfield code="h">631-645</subfield></datafield></record></collection>
|
author |
Winiker, Katharina |
spellingShingle |
Winiker, Katharina ddc 610 bkl 44.94 misc Deglutition misc Manometry misc High resolution manometry misc Impedance A systematic review of current methodology of high resolution pharyngeal manometry with and without impedance |
authorStr |
Winiker, Katharina |
ppnlink_with_tag_str_mv |
@@773@@(DE-627)253722667 |
format |
electronic Article |
dewey-ones |
610 - Medicine & health |
delete_txt_mv |
keep |
author_role |
aut aut aut aut aut |
collection |
springer |
remote_str |
true |
illustrated |
Not Illustrated |
issn |
1434-4726 |
topic_title |
610 ASE 44.94 bkl A systematic review of current methodology of high resolution pharyngeal manometry with and without impedance Deglutition (dpeaa)DE-He213 Manometry (dpeaa)DE-He213 High resolution manometry (dpeaa)DE-He213 Impedance (dpeaa)DE-He213 |
topic |
ddc 610 bkl 44.94 misc Deglutition misc Manometry misc High resolution manometry misc Impedance |
topic_unstemmed |
ddc 610 bkl 44.94 misc Deglutition misc Manometry misc High resolution manometry misc Impedance |
topic_browse |
ddc 610 bkl 44.94 misc Deglutition misc Manometry misc High resolution manometry misc Impedance |
format_facet |
Elektronische Aufsätze Aufsätze Elektronische Ressource |
format_main_str_mv |
Text Zeitschrift/Artikel |
carriertype_str_mv |
cr |
hierarchy_parent_title |
European archives of oto-rhino-laryngology and head & neck |
hierarchy_parent_id |
253722667 |
dewey-tens |
610 - Medicine & health |
hierarchy_top_title |
European archives of oto-rhino-laryngology and head & neck |
isfreeaccess_txt |
false |
familylinks_str_mv |
(DE-627)253722667 (DE-600)1459042-6 |
title |
A systematic review of current methodology of high resolution pharyngeal manometry with and without impedance |
ctrlnum |
(DE-627)SPR005217199 (SPR)s00405-018-5240-9-e |
title_full |
A systematic review of current methodology of high resolution pharyngeal manometry with and without impedance |
author_sort |
Winiker, Katharina |
journal |
European archives of oto-rhino-laryngology and head & neck |
journalStr |
European archives of oto-rhino-laryngology and head & neck |
lang_code |
eng |
isOA_bool |
false |
dewey-hundreds |
600 - Technology |
recordtype |
marc |
publishDateSort |
2018 |
contenttype_str_mv |
txt |
container_start_page |
631 |
author_browse |
Winiker, Katharina Gillman, Anna Guiu Hernandez, Esther Huckabee, Maggie-Lee Gozdzikowska, Kristin |
container_volume |
276 |
class |
610 ASE 44.94 bkl |
format_se |
Elektronische Aufsätze |
author-letter |
Winiker, Katharina |
doi_str_mv |
10.1007/s00405-018-5240-9 |
dewey-full |
610 |
author2-role |
verfasserin |
title_sort |
systematic review of current methodology of high resolution pharyngeal manometry with and without impedance |
title_auth |
A systematic review of current methodology of high resolution pharyngeal manometry with and without impedance |
abstract |
Purpose This systematic review appraises and summaries methodology documented in studies using high resolution pharyngeal manometry (HRM) with and without impedance technology (HRIM) in adult populations. Methods Four electronic databases CINAHL, EMBASE, MEDLINE, and Cochrane Library were searched up to, and including March 2017. Studies reporting pharyngeal HRM/HRIM for swallowing and/or phonatory assessment, published in peer-reviewed journals in English, German, or Spanish were assessed for the inclusion criteria. Of the selected studies, methodological aspects of data acquisition and analysis were extracted. Publications were graded based on their level of evidence and quality of methodological aspects was assessed. Results Sixty-two articles were identified eligible, from which 50 studies reported the use of HRM and 12 studies used HRIM. Of all included manuscripts, the majority utilized the ManoScan™ system (64.5%), a catheter diameter of 4.2 mm was most prevalently documented (30.6%). Most publications reported the application of topical anesthesia (53.2%). For data analysis in studies using HRM, software intrinsic to the recording system was reported most frequently (56%). A minority of the studies using HRM provided data about measurement reliability (10%). This is higher for studies using HRIM (50%). Conclusions Considerable methodological variability exists regarding data acquisition and analysis in published studies using HRM/HRIM. Lacking reports of methodology make study replications difficult and reduce the comparability across studies. More data regarding the impact of individual methodological aspects on study outcomes are further required for the development of methodological recommendations. |
abstractGer |
Purpose This systematic review appraises and summaries methodology documented in studies using high resolution pharyngeal manometry (HRM) with and without impedance technology (HRIM) in adult populations. Methods Four electronic databases CINAHL, EMBASE, MEDLINE, and Cochrane Library were searched up to, and including March 2017. Studies reporting pharyngeal HRM/HRIM for swallowing and/or phonatory assessment, published in peer-reviewed journals in English, German, or Spanish were assessed for the inclusion criteria. Of the selected studies, methodological aspects of data acquisition and analysis were extracted. Publications were graded based on their level of evidence and quality of methodological aspects was assessed. Results Sixty-two articles were identified eligible, from which 50 studies reported the use of HRM and 12 studies used HRIM. Of all included manuscripts, the majority utilized the ManoScan™ system (64.5%), a catheter diameter of 4.2 mm was most prevalently documented (30.6%). Most publications reported the application of topical anesthesia (53.2%). For data analysis in studies using HRM, software intrinsic to the recording system was reported most frequently (56%). A minority of the studies using HRM provided data about measurement reliability (10%). This is higher for studies using HRIM (50%). Conclusions Considerable methodological variability exists regarding data acquisition and analysis in published studies using HRM/HRIM. Lacking reports of methodology make study replications difficult and reduce the comparability across studies. More data regarding the impact of individual methodological aspects on study outcomes are further required for the development of methodological recommendations. |
abstract_unstemmed |
Purpose This systematic review appraises and summaries methodology documented in studies using high resolution pharyngeal manometry (HRM) with and without impedance technology (HRIM) in adult populations. Methods Four electronic databases CINAHL, EMBASE, MEDLINE, and Cochrane Library were searched up to, and including March 2017. Studies reporting pharyngeal HRM/HRIM for swallowing and/or phonatory assessment, published in peer-reviewed journals in English, German, or Spanish were assessed for the inclusion criteria. Of the selected studies, methodological aspects of data acquisition and analysis were extracted. Publications were graded based on their level of evidence and quality of methodological aspects was assessed. Results Sixty-two articles were identified eligible, from which 50 studies reported the use of HRM and 12 studies used HRIM. Of all included manuscripts, the majority utilized the ManoScan™ system (64.5%), a catheter diameter of 4.2 mm was most prevalently documented (30.6%). Most publications reported the application of topical anesthesia (53.2%). For data analysis in studies using HRM, software intrinsic to the recording system was reported most frequently (56%). A minority of the studies using HRM provided data about measurement reliability (10%). This is higher for studies using HRIM (50%). Conclusions Considerable methodological variability exists regarding data acquisition and analysis in published studies using HRM/HRIM. Lacking reports of methodology make study replications difficult and reduce the comparability across studies. More data regarding the impact of individual methodological aspects on study outcomes are further required for the development of methodological recommendations. |
collection_details |
GBV_USEFLAG_A SYSFLAG_A GBV_SPRINGER SSG-OLC-PHA GBV_ILN_11 GBV_ILN_20 GBV_ILN_22 GBV_ILN_23 GBV_ILN_24 GBV_ILN_31 GBV_ILN_32 GBV_ILN_39 GBV_ILN_40 GBV_ILN_60 GBV_ILN_62 GBV_ILN_63 GBV_ILN_65 GBV_ILN_69 GBV_ILN_70 GBV_ILN_73 GBV_ILN_74 GBV_ILN_90 GBV_ILN_95 GBV_ILN_100 GBV_ILN_101 GBV_ILN_105 GBV_ILN_110 GBV_ILN_120 GBV_ILN_138 GBV_ILN_150 GBV_ILN_151 GBV_ILN_152 GBV_ILN_161 GBV_ILN_170 GBV_ILN_171 GBV_ILN_187 GBV_ILN_213 GBV_ILN_224 GBV_ILN_230 GBV_ILN_250 GBV_ILN_267 GBV_ILN_281 GBV_ILN_285 GBV_ILN_293 GBV_ILN_370 GBV_ILN_602 GBV_ILN_636 GBV_ILN_702 GBV_ILN_711 GBV_ILN_2001 GBV_ILN_2003 GBV_ILN_2004 GBV_ILN_2005 GBV_ILN_2006 GBV_ILN_2007 GBV_ILN_2008 GBV_ILN_2009 GBV_ILN_2010 GBV_ILN_2011 GBV_ILN_2014 GBV_ILN_2015 GBV_ILN_2020 GBV_ILN_2021 GBV_ILN_2025 GBV_ILN_2026 GBV_ILN_2027 GBV_ILN_2031 GBV_ILN_2034 GBV_ILN_2037 GBV_ILN_2038 GBV_ILN_2039 GBV_ILN_2044 GBV_ILN_2048 GBV_ILN_2049 GBV_ILN_2050 GBV_ILN_2055 GBV_ILN_2057 GBV_ILN_2059 GBV_ILN_2061 GBV_ILN_2064 GBV_ILN_2065 GBV_ILN_2068 GBV_ILN_2070 GBV_ILN_2086 GBV_ILN_2088 GBV_ILN_2093 GBV_ILN_2106 GBV_ILN_2107 GBV_ILN_2108 GBV_ILN_2110 GBV_ILN_2111 GBV_ILN_2112 GBV_ILN_2113 GBV_ILN_2116 GBV_ILN_2118 GBV_ILN_2119 GBV_ILN_2122 GBV_ILN_2129 GBV_ILN_2143 GBV_ILN_2144 GBV_ILN_2147 GBV_ILN_2148 GBV_ILN_2152 GBV_ILN_2153 GBV_ILN_2188 GBV_ILN_2190 GBV_ILN_2232 GBV_ILN_2336 GBV_ILN_2446 GBV_ILN_2470 GBV_ILN_2472 GBV_ILN_2507 GBV_ILN_2522 GBV_ILN_2548 GBV_ILN_4012 GBV_ILN_4035 GBV_ILN_4037 GBV_ILN_4046 GBV_ILN_4112 GBV_ILN_4125 GBV_ILN_4126 GBV_ILN_4242 GBV_ILN_4246 GBV_ILN_4249 GBV_ILN_4251 GBV_ILN_4305 GBV_ILN_4306 GBV_ILN_4307 GBV_ILN_4313 GBV_ILN_4322 GBV_ILN_4323 GBV_ILN_4324 GBV_ILN_4325 GBV_ILN_4326 GBV_ILN_4328 GBV_ILN_4333 GBV_ILN_4334 GBV_ILN_4335 GBV_ILN_4336 GBV_ILN_4338 GBV_ILN_4393 GBV_ILN_4700 |
container_issue |
3 |
title_short |
A systematic review of current methodology of high resolution pharyngeal manometry with and without impedance |
url |
https://dx.doi.org/10.1007/s00405-018-5240-9 |
remote_bool |
true |
author2 |
Gillman, Anna Guiu Hernandez, Esther Huckabee, Maggie-Lee Gozdzikowska, Kristin |
author2Str |
Gillman, Anna Guiu Hernandez, Esther Huckabee, Maggie-Lee Gozdzikowska, Kristin |
ppnlink |
253722667 |
mediatype_str_mv |
c |
isOA_txt |
false |
hochschulschrift_bool |
false |
doi_str |
10.1007/s00405-018-5240-9 |
up_date |
2024-07-03T14:48:48.620Z |
_version_ |
1803569729236893696 |
fullrecord_marcxml |
<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim"><record><leader>01000caa a22002652 4500</leader><controlfield tag="001">SPR005217199</controlfield><controlfield tag="003">DE-627</controlfield><controlfield tag="005">20230520000758.0</controlfield><controlfield tag="007">cr uuu---uuuuu</controlfield><controlfield tag="008">201001s2018 xx |||||o 00| ||eng c</controlfield><datafield tag="024" ind1="7" ind2=" "><subfield code="a">10.1007/s00405-018-5240-9</subfield><subfield code="2">doi</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-627)SPR005217199</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(SPR)s00405-018-5240-9-e</subfield></datafield><datafield tag="040" ind1=" " ind2=" "><subfield code="a">DE-627</subfield><subfield code="b">ger</subfield><subfield code="c">DE-627</subfield><subfield code="e">rakwb</subfield></datafield><datafield tag="041" ind1=" " ind2=" "><subfield code="a">eng</subfield></datafield><datafield tag="082" ind1="0" ind2="4"><subfield code="a">610</subfield><subfield code="q">ASE</subfield></datafield><datafield tag="084" ind1=" " ind2=" "><subfield code="a">44.94</subfield><subfield code="2">bkl</subfield></datafield><datafield tag="100" ind1="1" ind2=" "><subfield code="a">Winiker, Katharina</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="245" ind1="1" ind2="2"><subfield code="a">A systematic review of current methodology of high resolution pharyngeal manometry with and without impedance</subfield></datafield><datafield tag="264" ind1=" " ind2="1"><subfield code="c">2018</subfield></datafield><datafield tag="336" ind1=" " ind2=" "><subfield code="a">Text</subfield><subfield code="b">txt</subfield><subfield code="2">rdacontent</subfield></datafield><datafield tag="337" ind1=" " ind2=" "><subfield code="a">Computermedien</subfield><subfield code="b">c</subfield><subfield code="2">rdamedia</subfield></datafield><datafield tag="338" ind1=" " ind2=" "><subfield code="a">Online-Ressource</subfield><subfield code="b">cr</subfield><subfield code="2">rdacarrier</subfield></datafield><datafield tag="520" ind1=" " ind2=" "><subfield code="a">Purpose This systematic review appraises and summaries methodology documented in studies using high resolution pharyngeal manometry (HRM) with and without impedance technology (HRIM) in adult populations. Methods Four electronic databases CINAHL, EMBASE, MEDLINE, and Cochrane Library were searched up to, and including March 2017. Studies reporting pharyngeal HRM/HRIM for swallowing and/or phonatory assessment, published in peer-reviewed journals in English, German, or Spanish were assessed for the inclusion criteria. Of the selected studies, methodological aspects of data acquisition and analysis were extracted. Publications were graded based on their level of evidence and quality of methodological aspects was assessed. Results Sixty-two articles were identified eligible, from which 50 studies reported the use of HRM and 12 studies used HRIM. Of all included manuscripts, the majority utilized the ManoScan™ system (64.5%), a catheter diameter of 4.2 mm was most prevalently documented (30.6%). Most publications reported the application of topical anesthesia (53.2%). For data analysis in studies using HRM, software intrinsic to the recording system was reported most frequently (56%). A minority of the studies using HRM provided data about measurement reliability (10%). This is higher for studies using HRIM (50%). Conclusions Considerable methodological variability exists regarding data acquisition and analysis in published studies using HRM/HRIM. Lacking reports of methodology make study replications difficult and reduce the comparability across studies. More data regarding the impact of individual methodological aspects on study outcomes are further required for the development of methodological recommendations.</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Deglutition</subfield><subfield code="7">(dpeaa)DE-He213</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Manometry</subfield><subfield code="7">(dpeaa)DE-He213</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">High resolution manometry</subfield><subfield code="7">(dpeaa)DE-He213</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Impedance</subfield><subfield code="7">(dpeaa)DE-He213</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Gillman, Anna</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Guiu Hernandez, Esther</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Huckabee, Maggie-Lee</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Gozdzikowska, Kristin</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="773" ind1="0" ind2="8"><subfield code="i">Enthalten in</subfield><subfield code="t">European archives of oto-rhino-laryngology and head & neck</subfield><subfield code="d">Berlin : Springer, 1864</subfield><subfield code="g">276(2018), 3 vom: 13. Dez., Seite 631-645</subfield><subfield code="w">(DE-627)253722667</subfield><subfield code="w">(DE-600)1459042-6</subfield><subfield code="x">1434-4726</subfield><subfield code="7">nnns</subfield></datafield><datafield tag="773" ind1="1" ind2="8"><subfield code="g">volume:276</subfield><subfield code="g">year:2018</subfield><subfield code="g">number:3</subfield><subfield code="g">day:13</subfield><subfield code="g">month:12</subfield><subfield code="g">pages:631-645</subfield></datafield><datafield tag="856" ind1="4" ind2="0"><subfield code="u">https://dx.doi.org/10.1007/s00405-018-5240-9</subfield><subfield code="z">lizenzpflichtig</subfield><subfield code="3">Volltext</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_USEFLAG_A</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">SYSFLAG_A</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_SPRINGER</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">SSG-OLC-PHA</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_11</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_20</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_22</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_23</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_24</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_31</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_32</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_39</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_40</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_60</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_62</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_63</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_65</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_69</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_70</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_73</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_74</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_90</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_95</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_100</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_101</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_105</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_110</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_120</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_138</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_150</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_151</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_152</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_161</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_170</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_171</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_187</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_213</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_224</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_230</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_250</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_267</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_281</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_285</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_293</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_370</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_602</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_636</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_702</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_711</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2001</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2003</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2004</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2005</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2006</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2007</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2008</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2009</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2010</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2011</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2014</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2015</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2020</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2021</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2025</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2026</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2027</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2031</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2034</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2037</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2038</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2039</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2044</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2048</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2049</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2050</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2055</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2057</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2059</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2061</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2064</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2065</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2068</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2070</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2086</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2088</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2093</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2106</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2107</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2108</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2110</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2111</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2112</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2113</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2116</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2118</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2119</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2122</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2129</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2143</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2144</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2147</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2148</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2152</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2153</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2188</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2190</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2232</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2336</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2446</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2470</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2472</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2507</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2522</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2548</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4012</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4035</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4037</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4046</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4112</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4125</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4126</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4242</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4246</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4249</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4251</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4305</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4306</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4307</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4313</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4322</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4323</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4324</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4325</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4326</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4328</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4333</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4334</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4335</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4336</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4338</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4393</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4700</subfield></datafield><datafield tag="936" ind1="b" ind2="k"><subfield code="a">44.94</subfield><subfield code="q">ASE</subfield></datafield><datafield tag="951" ind1=" " ind2=" "><subfield code="a">AR</subfield></datafield><datafield tag="952" ind1=" " ind2=" "><subfield code="d">276</subfield><subfield code="j">2018</subfield><subfield code="e">3</subfield><subfield code="b">13</subfield><subfield code="c">12</subfield><subfield code="h">631-645</subfield></datafield></record></collection>
|
score |
7.3999224 |