A prospective, randomized clinical comparison between UltraCision and the novel sealing and cutting device BiCision in patients with laparoscopic supracervical hysterectomy
Background Various surgical procedures for hysterectomy exist; with laparoscopic supracervical hysterectomy (LASH) becoming an established option in recent years. Therefore, energy-based technologies for rapid tissue sealing and cutting are in the focus of surgeons. The aim of this trial was to prov...
Ausführliche Beschreibung
Autor*in: |
Rothmund, Ralf [verfasserIn] Szyrach, Mara [verfasserIn] Reda, Ali [verfasserIn] Enderle, Markus D. [verfasserIn] Neugebauer, Alexander [verfasserIn] Taran, Florin-Andrei [verfasserIn] Brucker, Sara [verfasserIn] Hausch, Andrea [verfasserIn] Wallwiener, Christian [verfasserIn] Kraemer, Bernhard [verfasserIn] |
---|
Format: |
E-Artikel |
---|---|
Sprache: |
Englisch |
Erschienen: |
2013 |
---|
Schlagwörter: |
---|
Übergeordnetes Werk: |
Enthalten in: Surgical endoscopy and other interventional techniques - New York, NY : Springer, 1987, 27(2013), 10 vom: 14. Mai, Seite 3852-3859 |
---|---|
Übergeordnetes Werk: |
volume:27 ; year:2013 ; number:10 ; day:14 ; month:05 ; pages:3852-3859 |
Links: |
---|
DOI / URN: |
10.1007/s00464-013-2994-4 |
---|
Katalog-ID: |
SPR006300804 |
---|
LEADER | 01000caa a22002652 4500 | ||
---|---|---|---|
001 | SPR006300804 | ||
003 | DE-627 | ||
005 | 20230520001314.0 | ||
007 | cr uuu---uuuuu | ||
008 | 201002s2013 xx |||||o 00| ||eng c | ||
024 | 7 | |a 10.1007/s00464-013-2994-4 |2 doi | |
035 | |a (DE-627)SPR006300804 | ||
035 | |a (SPR)s00464-013-2994-4-e | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
082 | 0 | 4 | |a 610 |q ASE |
082 | 0 | 4 | |a 610 |q ASE |
084 | |a 44.87 |2 bkl | ||
100 | 1 | |a Rothmund, Ralf |e verfasserin |4 aut | |
245 | 1 | 2 | |a A prospective, randomized clinical comparison between UltraCision and the novel sealing and cutting device BiCision in patients with laparoscopic supracervical hysterectomy |
264 | 1 | |c 2013 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a Computermedien |b c |2 rdamedia | ||
338 | |a Online-Ressource |b cr |2 rdacarrier | ||
520 | |a Background Various surgical procedures for hysterectomy exist; with laparoscopic supracervical hysterectomy (LASH) becoming an established option in recent years. Therefore, energy-based technologies for rapid tissue sealing and cutting are in the focus of surgeons. The aim of this trial was to prove or disprove investigated noninferiority of the novel device BiCision in comparison to the widely used UltraCision in a routine procedure (www.clinicaltrials.gov; study identifier NCT01806012). Methods Thirty LASH procedures were performed with UltraCision and BiCision after randomization of the preparation sides. The primary end point was the resection time per side and instrument. The instruments were also compared concerning blood loss and coagulation and cutting qualities as well as postoperative complications. The patients were followed for 3 months. Results Mean preparation time per side was 8.8 ± 1.8 min for BiCision and 8.3 ± 1.9 min for UltraCision (p = 0.31), which was not significantly different. Both instruments achieved complete transection without the need of additional cutting attempts. BiCision was significantly superior regarding the number of coagulations for complete hemostasis before and after the removal of the uterine corpus (before: 6.9 ± 4.8 for BiCision and 8.6 ± 4.1 for UltraCision, p = 0.047; after: 5.4 ± 1.2 for BiCision and 8.6 ± 3.2 for UltraCision, p < 0.0001) and intraoperative blood loss (score 1.07 ± 0.25 for BiCision vs. 1.63 ± 0.49 for UltraCision, p < 0.0001). Tissue sticking to the instrument occurred less often on the BiCision side (score 0.14 ± 0.35 for BiCision vs. 0.60 ± 0.81 for UltraCision, p = 0.015). BiCision showed a significantly better fixation of the tissue (grip score 0.23 ± 0.43 for BiCision vs. 1.00 ± 0.74 for UltraCision, p < 0.0001). No intraoperative or postoperative complications were seen for both instruments. Conclusions The efficacy and quality of vessel sealing and cutting with BiCision is not inferior to the UltraCision device. Resection time was comparable, and complete hemostasis could be achieved faster in a clinical setting. Therefore, BiCision is at least as reliable as UltraCision for laparoscopic indications. | ||
650 | 4 | |a Bipolar electrocoagulation |7 (dpeaa)DE-He213 | |
650 | 4 | |a Supracervical hysterectomy |7 (dpeaa)DE-He213 | |
650 | 4 | |a Vessel sealing |7 (dpeaa)DE-He213 | |
700 | 1 | |a Szyrach, Mara |e verfasserin |4 aut | |
700 | 1 | |a Reda, Ali |e verfasserin |4 aut | |
700 | 1 | |a Enderle, Markus D. |e verfasserin |4 aut | |
700 | 1 | |a Neugebauer, Alexander |e verfasserin |4 aut | |
700 | 1 | |a Taran, Florin-Andrei |e verfasserin |4 aut | |
700 | 1 | |a Brucker, Sara |e verfasserin |4 aut | |
700 | 1 | |a Hausch, Andrea |e verfasserin |4 aut | |
700 | 1 | |a Wallwiener, Christian |e verfasserin |4 aut | |
700 | 1 | |a Kraemer, Bernhard |e verfasserin |4 aut | |
773 | 0 | 8 | |i Enthalten in |t Surgical endoscopy and other interventional techniques |d New York, NY : Springer, 1987 |g 27(2013), 10 vom: 14. Mai, Seite 3852-3859 |w (DE-627)254909620 |w (DE-600)1463171-4 |x 1432-2218 |7 nnns |
773 | 1 | 8 | |g volume:27 |g year:2013 |g number:10 |g day:14 |g month:05 |g pages:3852-3859 |
856 | 4 | 0 | |u https://dx.doi.org/10.1007/s00464-013-2994-4 |z lizenzpflichtig |3 Volltext |
912 | |a GBV_USEFLAG_A | ||
912 | |a SYSFLAG_A | ||
912 | |a GBV_SPRINGER | ||
912 | |a SSG-OLC-PHA | ||
912 | |a GBV_ILN_11 | ||
912 | |a GBV_ILN_20 | ||
912 | |a GBV_ILN_22 | ||
912 | |a GBV_ILN_23 | ||
912 | |a GBV_ILN_24 | ||
912 | |a GBV_ILN_31 | ||
912 | |a GBV_ILN_32 | ||
912 | |a GBV_ILN_39 | ||
912 | |a GBV_ILN_40 | ||
912 | |a GBV_ILN_60 | ||
912 | |a GBV_ILN_62 | ||
912 | |a GBV_ILN_63 | ||
912 | |a GBV_ILN_69 | ||
912 | |a GBV_ILN_70 | ||
912 | |a GBV_ILN_73 | ||
912 | |a GBV_ILN_74 | ||
912 | |a GBV_ILN_90 | ||
912 | |a GBV_ILN_95 | ||
912 | |a GBV_ILN_100 | ||
912 | |a GBV_ILN_101 | ||
912 | |a GBV_ILN_105 | ||
912 | |a GBV_ILN_110 | ||
912 | |a GBV_ILN_120 | ||
912 | |a GBV_ILN_138 | ||
912 | |a GBV_ILN_150 | ||
912 | |a GBV_ILN_151 | ||
912 | |a GBV_ILN_152 | ||
912 | |a GBV_ILN_161 | ||
912 | |a GBV_ILN_170 | ||
912 | |a GBV_ILN_171 | ||
912 | |a GBV_ILN_187 | ||
912 | |a GBV_ILN_213 | ||
912 | |a GBV_ILN_224 | ||
912 | |a GBV_ILN_230 | ||
912 | |a GBV_ILN_250 | ||
912 | |a GBV_ILN_267 | ||
912 | |a GBV_ILN_281 | ||
912 | |a GBV_ILN_285 | ||
912 | |a GBV_ILN_293 | ||
912 | |a GBV_ILN_370 | ||
912 | |a GBV_ILN_602 | ||
912 | |a GBV_ILN_636 | ||
912 | |a GBV_ILN_702 | ||
912 | |a GBV_ILN_711 | ||
912 | |a GBV_ILN_2001 | ||
912 | |a GBV_ILN_2003 | ||
912 | |a GBV_ILN_2004 | ||
912 | |a GBV_ILN_2005 | ||
912 | |a GBV_ILN_2006 | ||
912 | |a GBV_ILN_2007 | ||
912 | |a GBV_ILN_2008 | ||
912 | |a GBV_ILN_2009 | ||
912 | |a GBV_ILN_2010 | ||
912 | |a GBV_ILN_2011 | ||
912 | |a GBV_ILN_2014 | ||
912 | |a GBV_ILN_2015 | ||
912 | |a GBV_ILN_2020 | ||
912 | |a GBV_ILN_2021 | ||
912 | |a GBV_ILN_2025 | ||
912 | |a GBV_ILN_2026 | ||
912 | |a GBV_ILN_2027 | ||
912 | |a GBV_ILN_2031 | ||
912 | |a GBV_ILN_2034 | ||
912 | |a GBV_ILN_2037 | ||
912 | |a GBV_ILN_2038 | ||
912 | |a GBV_ILN_2044 | ||
912 | |a GBV_ILN_2048 | ||
912 | |a GBV_ILN_2049 | ||
912 | |a GBV_ILN_2050 | ||
912 | |a GBV_ILN_2055 | ||
912 | |a GBV_ILN_2057 | ||
912 | |a GBV_ILN_2059 | ||
912 | |a GBV_ILN_2061 | ||
912 | |a GBV_ILN_2064 | ||
912 | |a GBV_ILN_2065 | ||
912 | |a GBV_ILN_2068 | ||
912 | |a GBV_ILN_2070 | ||
912 | |a GBV_ILN_2086 | ||
912 | |a GBV_ILN_2093 | ||
912 | |a GBV_ILN_2106 | ||
912 | |a GBV_ILN_2107 | ||
912 | |a GBV_ILN_2108 | ||
912 | |a GBV_ILN_2110 | ||
912 | |a GBV_ILN_2111 | ||
912 | |a GBV_ILN_2113 | ||
912 | |a GBV_ILN_2116 | ||
912 | |a GBV_ILN_2118 | ||
912 | |a GBV_ILN_2119 | ||
912 | |a GBV_ILN_2129 | ||
912 | |a GBV_ILN_2143 | ||
912 | |a GBV_ILN_2144 | ||
912 | |a GBV_ILN_2147 | ||
912 | |a GBV_ILN_2153 | ||
912 | |a GBV_ILN_2188 | ||
912 | |a GBV_ILN_2190 | ||
912 | |a GBV_ILN_2232 | ||
912 | |a GBV_ILN_2336 | ||
912 | |a GBV_ILN_2446 | ||
912 | |a GBV_ILN_2470 | ||
912 | |a GBV_ILN_2472 | ||
912 | |a GBV_ILN_2507 | ||
912 | |a GBV_ILN_2522 | ||
912 | |a GBV_ILN_2548 | ||
912 | |a GBV_ILN_4012 | ||
912 | |a GBV_ILN_4035 | ||
912 | |a GBV_ILN_4037 | ||
912 | |a GBV_ILN_4046 | ||
912 | |a GBV_ILN_4112 | ||
912 | |a GBV_ILN_4125 | ||
912 | |a GBV_ILN_4126 | ||
912 | |a GBV_ILN_4242 | ||
912 | |a GBV_ILN_4246 | ||
912 | |a GBV_ILN_4249 | ||
912 | |a GBV_ILN_4251 | ||
912 | |a GBV_ILN_4305 | ||
912 | |a GBV_ILN_4306 | ||
912 | |a GBV_ILN_4307 | ||
912 | |a GBV_ILN_4313 | ||
912 | |a GBV_ILN_4322 | ||
912 | |a GBV_ILN_4323 | ||
912 | |a GBV_ILN_4324 | ||
912 | |a GBV_ILN_4326 | ||
912 | |a GBV_ILN_4328 | ||
912 | |a GBV_ILN_4333 | ||
912 | |a GBV_ILN_4334 | ||
912 | |a GBV_ILN_4335 | ||
912 | |a GBV_ILN_4336 | ||
912 | |a GBV_ILN_4338 | ||
912 | |a GBV_ILN_4393 | ||
912 | |a GBV_ILN_4700 | ||
936 | b | k | |a 44.87 |q ASE |
951 | |a AR | ||
952 | |d 27 |j 2013 |e 10 |b 14 |c 05 |h 3852-3859 |
author_variant |
r r rr m s ms a r ar m d e md mde a n an f a t fat s b sb a h ah c w cw b k bk |
---|---|
matchkey_str |
article:14322218:2013----::popcieadmzdlncloprsneweutaiinnteoesaignctigeieiiinnains |
hierarchy_sort_str |
2013 |
bklnumber |
44.87 |
publishDate |
2013 |
allfields |
10.1007/s00464-013-2994-4 doi (DE-627)SPR006300804 (SPR)s00464-013-2994-4-e DE-627 ger DE-627 rakwb eng 610 ASE 610 ASE 44.87 bkl Rothmund, Ralf verfasserin aut A prospective, randomized clinical comparison between UltraCision and the novel sealing and cutting device BiCision in patients with laparoscopic supracervical hysterectomy 2013 Text txt rdacontent Computermedien c rdamedia Online-Ressource cr rdacarrier Background Various surgical procedures for hysterectomy exist; with laparoscopic supracervical hysterectomy (LASH) becoming an established option in recent years. Therefore, energy-based technologies for rapid tissue sealing and cutting are in the focus of surgeons. The aim of this trial was to prove or disprove investigated noninferiority of the novel device BiCision in comparison to the widely used UltraCision in a routine procedure (www.clinicaltrials.gov; study identifier NCT01806012). Methods Thirty LASH procedures were performed with UltraCision and BiCision after randomization of the preparation sides. The primary end point was the resection time per side and instrument. The instruments were also compared concerning blood loss and coagulation and cutting qualities as well as postoperative complications. The patients were followed for 3 months. Results Mean preparation time per side was 8.8 ± 1.8 min for BiCision and 8.3 ± 1.9 min for UltraCision (p = 0.31), which was not significantly different. Both instruments achieved complete transection without the need of additional cutting attempts. BiCision was significantly superior regarding the number of coagulations for complete hemostasis before and after the removal of the uterine corpus (before: 6.9 ± 4.8 for BiCision and 8.6 ± 4.1 for UltraCision, p = 0.047; after: 5.4 ± 1.2 for BiCision and 8.6 ± 3.2 for UltraCision, p < 0.0001) and intraoperative blood loss (score 1.07 ± 0.25 for BiCision vs. 1.63 ± 0.49 for UltraCision, p < 0.0001). Tissue sticking to the instrument occurred less often on the BiCision side (score 0.14 ± 0.35 for BiCision vs. 0.60 ± 0.81 for UltraCision, p = 0.015). BiCision showed a significantly better fixation of the tissue (grip score 0.23 ± 0.43 for BiCision vs. 1.00 ± 0.74 for UltraCision, p < 0.0001). No intraoperative or postoperative complications were seen for both instruments. Conclusions The efficacy and quality of vessel sealing and cutting with BiCision is not inferior to the UltraCision device. Resection time was comparable, and complete hemostasis could be achieved faster in a clinical setting. Therefore, BiCision is at least as reliable as UltraCision for laparoscopic indications. Bipolar electrocoagulation (dpeaa)DE-He213 Supracervical hysterectomy (dpeaa)DE-He213 Vessel sealing (dpeaa)DE-He213 Szyrach, Mara verfasserin aut Reda, Ali verfasserin aut Enderle, Markus D. verfasserin aut Neugebauer, Alexander verfasserin aut Taran, Florin-Andrei verfasserin aut Brucker, Sara verfasserin aut Hausch, Andrea verfasserin aut Wallwiener, Christian verfasserin aut Kraemer, Bernhard verfasserin aut Enthalten in Surgical endoscopy and other interventional techniques New York, NY : Springer, 1987 27(2013), 10 vom: 14. Mai, Seite 3852-3859 (DE-627)254909620 (DE-600)1463171-4 1432-2218 nnns volume:27 year:2013 number:10 day:14 month:05 pages:3852-3859 https://dx.doi.org/10.1007/s00464-013-2994-4 lizenzpflichtig Volltext GBV_USEFLAG_A SYSFLAG_A GBV_SPRINGER SSG-OLC-PHA GBV_ILN_11 GBV_ILN_20 GBV_ILN_22 GBV_ILN_23 GBV_ILN_24 GBV_ILN_31 GBV_ILN_32 GBV_ILN_39 GBV_ILN_40 GBV_ILN_60 GBV_ILN_62 GBV_ILN_63 GBV_ILN_69 GBV_ILN_70 GBV_ILN_73 GBV_ILN_74 GBV_ILN_90 GBV_ILN_95 GBV_ILN_100 GBV_ILN_101 GBV_ILN_105 GBV_ILN_110 GBV_ILN_120 GBV_ILN_138 GBV_ILN_150 GBV_ILN_151 GBV_ILN_152 GBV_ILN_161 GBV_ILN_170 GBV_ILN_171 GBV_ILN_187 GBV_ILN_213 GBV_ILN_224 GBV_ILN_230 GBV_ILN_250 GBV_ILN_267 GBV_ILN_281 GBV_ILN_285 GBV_ILN_293 GBV_ILN_370 GBV_ILN_602 GBV_ILN_636 GBV_ILN_702 GBV_ILN_711 GBV_ILN_2001 GBV_ILN_2003 GBV_ILN_2004 GBV_ILN_2005 GBV_ILN_2006 GBV_ILN_2007 GBV_ILN_2008 GBV_ILN_2009 GBV_ILN_2010 GBV_ILN_2011 GBV_ILN_2014 GBV_ILN_2015 GBV_ILN_2020 GBV_ILN_2021 GBV_ILN_2025 GBV_ILN_2026 GBV_ILN_2027 GBV_ILN_2031 GBV_ILN_2034 GBV_ILN_2037 GBV_ILN_2038 GBV_ILN_2044 GBV_ILN_2048 GBV_ILN_2049 GBV_ILN_2050 GBV_ILN_2055 GBV_ILN_2057 GBV_ILN_2059 GBV_ILN_2061 GBV_ILN_2064 GBV_ILN_2065 GBV_ILN_2068 GBV_ILN_2070 GBV_ILN_2086 GBV_ILN_2093 GBV_ILN_2106 GBV_ILN_2107 GBV_ILN_2108 GBV_ILN_2110 GBV_ILN_2111 GBV_ILN_2113 GBV_ILN_2116 GBV_ILN_2118 GBV_ILN_2119 GBV_ILN_2129 GBV_ILN_2143 GBV_ILN_2144 GBV_ILN_2147 GBV_ILN_2153 GBV_ILN_2188 GBV_ILN_2190 GBV_ILN_2232 GBV_ILN_2336 GBV_ILN_2446 GBV_ILN_2470 GBV_ILN_2472 GBV_ILN_2507 GBV_ILN_2522 GBV_ILN_2548 GBV_ILN_4012 GBV_ILN_4035 GBV_ILN_4037 GBV_ILN_4046 GBV_ILN_4112 GBV_ILN_4125 GBV_ILN_4126 GBV_ILN_4242 GBV_ILN_4246 GBV_ILN_4249 GBV_ILN_4251 GBV_ILN_4305 GBV_ILN_4306 GBV_ILN_4307 GBV_ILN_4313 GBV_ILN_4322 GBV_ILN_4323 GBV_ILN_4324 GBV_ILN_4326 GBV_ILN_4328 GBV_ILN_4333 GBV_ILN_4334 GBV_ILN_4335 GBV_ILN_4336 GBV_ILN_4338 GBV_ILN_4393 GBV_ILN_4700 44.87 ASE AR 27 2013 10 14 05 3852-3859 |
spelling |
10.1007/s00464-013-2994-4 doi (DE-627)SPR006300804 (SPR)s00464-013-2994-4-e DE-627 ger DE-627 rakwb eng 610 ASE 610 ASE 44.87 bkl Rothmund, Ralf verfasserin aut A prospective, randomized clinical comparison between UltraCision and the novel sealing and cutting device BiCision in patients with laparoscopic supracervical hysterectomy 2013 Text txt rdacontent Computermedien c rdamedia Online-Ressource cr rdacarrier Background Various surgical procedures for hysterectomy exist; with laparoscopic supracervical hysterectomy (LASH) becoming an established option in recent years. Therefore, energy-based technologies for rapid tissue sealing and cutting are in the focus of surgeons. The aim of this trial was to prove or disprove investigated noninferiority of the novel device BiCision in comparison to the widely used UltraCision in a routine procedure (www.clinicaltrials.gov; study identifier NCT01806012). Methods Thirty LASH procedures were performed with UltraCision and BiCision after randomization of the preparation sides. The primary end point was the resection time per side and instrument. The instruments were also compared concerning blood loss and coagulation and cutting qualities as well as postoperative complications. The patients were followed for 3 months. Results Mean preparation time per side was 8.8 ± 1.8 min for BiCision and 8.3 ± 1.9 min for UltraCision (p = 0.31), which was not significantly different. Both instruments achieved complete transection without the need of additional cutting attempts. BiCision was significantly superior regarding the number of coagulations for complete hemostasis before and after the removal of the uterine corpus (before: 6.9 ± 4.8 for BiCision and 8.6 ± 4.1 for UltraCision, p = 0.047; after: 5.4 ± 1.2 for BiCision and 8.6 ± 3.2 for UltraCision, p < 0.0001) and intraoperative blood loss (score 1.07 ± 0.25 for BiCision vs. 1.63 ± 0.49 for UltraCision, p < 0.0001). Tissue sticking to the instrument occurred less often on the BiCision side (score 0.14 ± 0.35 for BiCision vs. 0.60 ± 0.81 for UltraCision, p = 0.015). BiCision showed a significantly better fixation of the tissue (grip score 0.23 ± 0.43 for BiCision vs. 1.00 ± 0.74 for UltraCision, p < 0.0001). No intraoperative or postoperative complications were seen for both instruments. Conclusions The efficacy and quality of vessel sealing and cutting with BiCision is not inferior to the UltraCision device. Resection time was comparable, and complete hemostasis could be achieved faster in a clinical setting. Therefore, BiCision is at least as reliable as UltraCision for laparoscopic indications. Bipolar electrocoagulation (dpeaa)DE-He213 Supracervical hysterectomy (dpeaa)DE-He213 Vessel sealing (dpeaa)DE-He213 Szyrach, Mara verfasserin aut Reda, Ali verfasserin aut Enderle, Markus D. verfasserin aut Neugebauer, Alexander verfasserin aut Taran, Florin-Andrei verfasserin aut Brucker, Sara verfasserin aut Hausch, Andrea verfasserin aut Wallwiener, Christian verfasserin aut Kraemer, Bernhard verfasserin aut Enthalten in Surgical endoscopy and other interventional techniques New York, NY : Springer, 1987 27(2013), 10 vom: 14. Mai, Seite 3852-3859 (DE-627)254909620 (DE-600)1463171-4 1432-2218 nnns volume:27 year:2013 number:10 day:14 month:05 pages:3852-3859 https://dx.doi.org/10.1007/s00464-013-2994-4 lizenzpflichtig Volltext GBV_USEFLAG_A SYSFLAG_A GBV_SPRINGER SSG-OLC-PHA GBV_ILN_11 GBV_ILN_20 GBV_ILN_22 GBV_ILN_23 GBV_ILN_24 GBV_ILN_31 GBV_ILN_32 GBV_ILN_39 GBV_ILN_40 GBV_ILN_60 GBV_ILN_62 GBV_ILN_63 GBV_ILN_69 GBV_ILN_70 GBV_ILN_73 GBV_ILN_74 GBV_ILN_90 GBV_ILN_95 GBV_ILN_100 GBV_ILN_101 GBV_ILN_105 GBV_ILN_110 GBV_ILN_120 GBV_ILN_138 GBV_ILN_150 GBV_ILN_151 GBV_ILN_152 GBV_ILN_161 GBV_ILN_170 GBV_ILN_171 GBV_ILN_187 GBV_ILN_213 GBV_ILN_224 GBV_ILN_230 GBV_ILN_250 GBV_ILN_267 GBV_ILN_281 GBV_ILN_285 GBV_ILN_293 GBV_ILN_370 GBV_ILN_602 GBV_ILN_636 GBV_ILN_702 GBV_ILN_711 GBV_ILN_2001 GBV_ILN_2003 GBV_ILN_2004 GBV_ILN_2005 GBV_ILN_2006 GBV_ILN_2007 GBV_ILN_2008 GBV_ILN_2009 GBV_ILN_2010 GBV_ILN_2011 GBV_ILN_2014 GBV_ILN_2015 GBV_ILN_2020 GBV_ILN_2021 GBV_ILN_2025 GBV_ILN_2026 GBV_ILN_2027 GBV_ILN_2031 GBV_ILN_2034 GBV_ILN_2037 GBV_ILN_2038 GBV_ILN_2044 GBV_ILN_2048 GBV_ILN_2049 GBV_ILN_2050 GBV_ILN_2055 GBV_ILN_2057 GBV_ILN_2059 GBV_ILN_2061 GBV_ILN_2064 GBV_ILN_2065 GBV_ILN_2068 GBV_ILN_2070 GBV_ILN_2086 GBV_ILN_2093 GBV_ILN_2106 GBV_ILN_2107 GBV_ILN_2108 GBV_ILN_2110 GBV_ILN_2111 GBV_ILN_2113 GBV_ILN_2116 GBV_ILN_2118 GBV_ILN_2119 GBV_ILN_2129 GBV_ILN_2143 GBV_ILN_2144 GBV_ILN_2147 GBV_ILN_2153 GBV_ILN_2188 GBV_ILN_2190 GBV_ILN_2232 GBV_ILN_2336 GBV_ILN_2446 GBV_ILN_2470 GBV_ILN_2472 GBV_ILN_2507 GBV_ILN_2522 GBV_ILN_2548 GBV_ILN_4012 GBV_ILN_4035 GBV_ILN_4037 GBV_ILN_4046 GBV_ILN_4112 GBV_ILN_4125 GBV_ILN_4126 GBV_ILN_4242 GBV_ILN_4246 GBV_ILN_4249 GBV_ILN_4251 GBV_ILN_4305 GBV_ILN_4306 GBV_ILN_4307 GBV_ILN_4313 GBV_ILN_4322 GBV_ILN_4323 GBV_ILN_4324 GBV_ILN_4326 GBV_ILN_4328 GBV_ILN_4333 GBV_ILN_4334 GBV_ILN_4335 GBV_ILN_4336 GBV_ILN_4338 GBV_ILN_4393 GBV_ILN_4700 44.87 ASE AR 27 2013 10 14 05 3852-3859 |
allfields_unstemmed |
10.1007/s00464-013-2994-4 doi (DE-627)SPR006300804 (SPR)s00464-013-2994-4-e DE-627 ger DE-627 rakwb eng 610 ASE 610 ASE 44.87 bkl Rothmund, Ralf verfasserin aut A prospective, randomized clinical comparison between UltraCision and the novel sealing and cutting device BiCision in patients with laparoscopic supracervical hysterectomy 2013 Text txt rdacontent Computermedien c rdamedia Online-Ressource cr rdacarrier Background Various surgical procedures for hysterectomy exist; with laparoscopic supracervical hysterectomy (LASH) becoming an established option in recent years. Therefore, energy-based technologies for rapid tissue sealing and cutting are in the focus of surgeons. The aim of this trial was to prove or disprove investigated noninferiority of the novel device BiCision in comparison to the widely used UltraCision in a routine procedure (www.clinicaltrials.gov; study identifier NCT01806012). Methods Thirty LASH procedures were performed with UltraCision and BiCision after randomization of the preparation sides. The primary end point was the resection time per side and instrument. The instruments were also compared concerning blood loss and coagulation and cutting qualities as well as postoperative complications. The patients were followed for 3 months. Results Mean preparation time per side was 8.8 ± 1.8 min for BiCision and 8.3 ± 1.9 min for UltraCision (p = 0.31), which was not significantly different. Both instruments achieved complete transection without the need of additional cutting attempts. BiCision was significantly superior regarding the number of coagulations for complete hemostasis before and after the removal of the uterine corpus (before: 6.9 ± 4.8 for BiCision and 8.6 ± 4.1 for UltraCision, p = 0.047; after: 5.4 ± 1.2 for BiCision and 8.6 ± 3.2 for UltraCision, p < 0.0001) and intraoperative blood loss (score 1.07 ± 0.25 for BiCision vs. 1.63 ± 0.49 for UltraCision, p < 0.0001). Tissue sticking to the instrument occurred less often on the BiCision side (score 0.14 ± 0.35 for BiCision vs. 0.60 ± 0.81 for UltraCision, p = 0.015). BiCision showed a significantly better fixation of the tissue (grip score 0.23 ± 0.43 for BiCision vs. 1.00 ± 0.74 for UltraCision, p < 0.0001). No intraoperative or postoperative complications were seen for both instruments. Conclusions The efficacy and quality of vessel sealing and cutting with BiCision is not inferior to the UltraCision device. Resection time was comparable, and complete hemostasis could be achieved faster in a clinical setting. Therefore, BiCision is at least as reliable as UltraCision for laparoscopic indications. Bipolar electrocoagulation (dpeaa)DE-He213 Supracervical hysterectomy (dpeaa)DE-He213 Vessel sealing (dpeaa)DE-He213 Szyrach, Mara verfasserin aut Reda, Ali verfasserin aut Enderle, Markus D. verfasserin aut Neugebauer, Alexander verfasserin aut Taran, Florin-Andrei verfasserin aut Brucker, Sara verfasserin aut Hausch, Andrea verfasserin aut Wallwiener, Christian verfasserin aut Kraemer, Bernhard verfasserin aut Enthalten in Surgical endoscopy and other interventional techniques New York, NY : Springer, 1987 27(2013), 10 vom: 14. Mai, Seite 3852-3859 (DE-627)254909620 (DE-600)1463171-4 1432-2218 nnns volume:27 year:2013 number:10 day:14 month:05 pages:3852-3859 https://dx.doi.org/10.1007/s00464-013-2994-4 lizenzpflichtig Volltext GBV_USEFLAG_A SYSFLAG_A GBV_SPRINGER SSG-OLC-PHA GBV_ILN_11 GBV_ILN_20 GBV_ILN_22 GBV_ILN_23 GBV_ILN_24 GBV_ILN_31 GBV_ILN_32 GBV_ILN_39 GBV_ILN_40 GBV_ILN_60 GBV_ILN_62 GBV_ILN_63 GBV_ILN_69 GBV_ILN_70 GBV_ILN_73 GBV_ILN_74 GBV_ILN_90 GBV_ILN_95 GBV_ILN_100 GBV_ILN_101 GBV_ILN_105 GBV_ILN_110 GBV_ILN_120 GBV_ILN_138 GBV_ILN_150 GBV_ILN_151 GBV_ILN_152 GBV_ILN_161 GBV_ILN_170 GBV_ILN_171 GBV_ILN_187 GBV_ILN_213 GBV_ILN_224 GBV_ILN_230 GBV_ILN_250 GBV_ILN_267 GBV_ILN_281 GBV_ILN_285 GBV_ILN_293 GBV_ILN_370 GBV_ILN_602 GBV_ILN_636 GBV_ILN_702 GBV_ILN_711 GBV_ILN_2001 GBV_ILN_2003 GBV_ILN_2004 GBV_ILN_2005 GBV_ILN_2006 GBV_ILN_2007 GBV_ILN_2008 GBV_ILN_2009 GBV_ILN_2010 GBV_ILN_2011 GBV_ILN_2014 GBV_ILN_2015 GBV_ILN_2020 GBV_ILN_2021 GBV_ILN_2025 GBV_ILN_2026 GBV_ILN_2027 GBV_ILN_2031 GBV_ILN_2034 GBV_ILN_2037 GBV_ILN_2038 GBV_ILN_2044 GBV_ILN_2048 GBV_ILN_2049 GBV_ILN_2050 GBV_ILN_2055 GBV_ILN_2057 GBV_ILN_2059 GBV_ILN_2061 GBV_ILN_2064 GBV_ILN_2065 GBV_ILN_2068 GBV_ILN_2070 GBV_ILN_2086 GBV_ILN_2093 GBV_ILN_2106 GBV_ILN_2107 GBV_ILN_2108 GBV_ILN_2110 GBV_ILN_2111 GBV_ILN_2113 GBV_ILN_2116 GBV_ILN_2118 GBV_ILN_2119 GBV_ILN_2129 GBV_ILN_2143 GBV_ILN_2144 GBV_ILN_2147 GBV_ILN_2153 GBV_ILN_2188 GBV_ILN_2190 GBV_ILN_2232 GBV_ILN_2336 GBV_ILN_2446 GBV_ILN_2470 GBV_ILN_2472 GBV_ILN_2507 GBV_ILN_2522 GBV_ILN_2548 GBV_ILN_4012 GBV_ILN_4035 GBV_ILN_4037 GBV_ILN_4046 GBV_ILN_4112 GBV_ILN_4125 GBV_ILN_4126 GBV_ILN_4242 GBV_ILN_4246 GBV_ILN_4249 GBV_ILN_4251 GBV_ILN_4305 GBV_ILN_4306 GBV_ILN_4307 GBV_ILN_4313 GBV_ILN_4322 GBV_ILN_4323 GBV_ILN_4324 GBV_ILN_4326 GBV_ILN_4328 GBV_ILN_4333 GBV_ILN_4334 GBV_ILN_4335 GBV_ILN_4336 GBV_ILN_4338 GBV_ILN_4393 GBV_ILN_4700 44.87 ASE AR 27 2013 10 14 05 3852-3859 |
allfieldsGer |
10.1007/s00464-013-2994-4 doi (DE-627)SPR006300804 (SPR)s00464-013-2994-4-e DE-627 ger DE-627 rakwb eng 610 ASE 610 ASE 44.87 bkl Rothmund, Ralf verfasserin aut A prospective, randomized clinical comparison between UltraCision and the novel sealing and cutting device BiCision in patients with laparoscopic supracervical hysterectomy 2013 Text txt rdacontent Computermedien c rdamedia Online-Ressource cr rdacarrier Background Various surgical procedures for hysterectomy exist; with laparoscopic supracervical hysterectomy (LASH) becoming an established option in recent years. Therefore, energy-based technologies for rapid tissue sealing and cutting are in the focus of surgeons. The aim of this trial was to prove or disprove investigated noninferiority of the novel device BiCision in comparison to the widely used UltraCision in a routine procedure (www.clinicaltrials.gov; study identifier NCT01806012). Methods Thirty LASH procedures were performed with UltraCision and BiCision after randomization of the preparation sides. The primary end point was the resection time per side and instrument. The instruments were also compared concerning blood loss and coagulation and cutting qualities as well as postoperative complications. The patients were followed for 3 months. Results Mean preparation time per side was 8.8 ± 1.8 min for BiCision and 8.3 ± 1.9 min for UltraCision (p = 0.31), which was not significantly different. Both instruments achieved complete transection without the need of additional cutting attempts. BiCision was significantly superior regarding the number of coagulations for complete hemostasis before and after the removal of the uterine corpus (before: 6.9 ± 4.8 for BiCision and 8.6 ± 4.1 for UltraCision, p = 0.047; after: 5.4 ± 1.2 for BiCision and 8.6 ± 3.2 for UltraCision, p < 0.0001) and intraoperative blood loss (score 1.07 ± 0.25 for BiCision vs. 1.63 ± 0.49 for UltraCision, p < 0.0001). Tissue sticking to the instrument occurred less often on the BiCision side (score 0.14 ± 0.35 for BiCision vs. 0.60 ± 0.81 for UltraCision, p = 0.015). BiCision showed a significantly better fixation of the tissue (grip score 0.23 ± 0.43 for BiCision vs. 1.00 ± 0.74 for UltraCision, p < 0.0001). No intraoperative or postoperative complications were seen for both instruments. Conclusions The efficacy and quality of vessel sealing and cutting with BiCision is not inferior to the UltraCision device. Resection time was comparable, and complete hemostasis could be achieved faster in a clinical setting. Therefore, BiCision is at least as reliable as UltraCision for laparoscopic indications. Bipolar electrocoagulation (dpeaa)DE-He213 Supracervical hysterectomy (dpeaa)DE-He213 Vessel sealing (dpeaa)DE-He213 Szyrach, Mara verfasserin aut Reda, Ali verfasserin aut Enderle, Markus D. verfasserin aut Neugebauer, Alexander verfasserin aut Taran, Florin-Andrei verfasserin aut Brucker, Sara verfasserin aut Hausch, Andrea verfasserin aut Wallwiener, Christian verfasserin aut Kraemer, Bernhard verfasserin aut Enthalten in Surgical endoscopy and other interventional techniques New York, NY : Springer, 1987 27(2013), 10 vom: 14. Mai, Seite 3852-3859 (DE-627)254909620 (DE-600)1463171-4 1432-2218 nnns volume:27 year:2013 number:10 day:14 month:05 pages:3852-3859 https://dx.doi.org/10.1007/s00464-013-2994-4 lizenzpflichtig Volltext GBV_USEFLAG_A SYSFLAG_A GBV_SPRINGER SSG-OLC-PHA GBV_ILN_11 GBV_ILN_20 GBV_ILN_22 GBV_ILN_23 GBV_ILN_24 GBV_ILN_31 GBV_ILN_32 GBV_ILN_39 GBV_ILN_40 GBV_ILN_60 GBV_ILN_62 GBV_ILN_63 GBV_ILN_69 GBV_ILN_70 GBV_ILN_73 GBV_ILN_74 GBV_ILN_90 GBV_ILN_95 GBV_ILN_100 GBV_ILN_101 GBV_ILN_105 GBV_ILN_110 GBV_ILN_120 GBV_ILN_138 GBV_ILN_150 GBV_ILN_151 GBV_ILN_152 GBV_ILN_161 GBV_ILN_170 GBV_ILN_171 GBV_ILN_187 GBV_ILN_213 GBV_ILN_224 GBV_ILN_230 GBV_ILN_250 GBV_ILN_267 GBV_ILN_281 GBV_ILN_285 GBV_ILN_293 GBV_ILN_370 GBV_ILN_602 GBV_ILN_636 GBV_ILN_702 GBV_ILN_711 GBV_ILN_2001 GBV_ILN_2003 GBV_ILN_2004 GBV_ILN_2005 GBV_ILN_2006 GBV_ILN_2007 GBV_ILN_2008 GBV_ILN_2009 GBV_ILN_2010 GBV_ILN_2011 GBV_ILN_2014 GBV_ILN_2015 GBV_ILN_2020 GBV_ILN_2021 GBV_ILN_2025 GBV_ILN_2026 GBV_ILN_2027 GBV_ILN_2031 GBV_ILN_2034 GBV_ILN_2037 GBV_ILN_2038 GBV_ILN_2044 GBV_ILN_2048 GBV_ILN_2049 GBV_ILN_2050 GBV_ILN_2055 GBV_ILN_2057 GBV_ILN_2059 GBV_ILN_2061 GBV_ILN_2064 GBV_ILN_2065 GBV_ILN_2068 GBV_ILN_2070 GBV_ILN_2086 GBV_ILN_2093 GBV_ILN_2106 GBV_ILN_2107 GBV_ILN_2108 GBV_ILN_2110 GBV_ILN_2111 GBV_ILN_2113 GBV_ILN_2116 GBV_ILN_2118 GBV_ILN_2119 GBV_ILN_2129 GBV_ILN_2143 GBV_ILN_2144 GBV_ILN_2147 GBV_ILN_2153 GBV_ILN_2188 GBV_ILN_2190 GBV_ILN_2232 GBV_ILN_2336 GBV_ILN_2446 GBV_ILN_2470 GBV_ILN_2472 GBV_ILN_2507 GBV_ILN_2522 GBV_ILN_2548 GBV_ILN_4012 GBV_ILN_4035 GBV_ILN_4037 GBV_ILN_4046 GBV_ILN_4112 GBV_ILN_4125 GBV_ILN_4126 GBV_ILN_4242 GBV_ILN_4246 GBV_ILN_4249 GBV_ILN_4251 GBV_ILN_4305 GBV_ILN_4306 GBV_ILN_4307 GBV_ILN_4313 GBV_ILN_4322 GBV_ILN_4323 GBV_ILN_4324 GBV_ILN_4326 GBV_ILN_4328 GBV_ILN_4333 GBV_ILN_4334 GBV_ILN_4335 GBV_ILN_4336 GBV_ILN_4338 GBV_ILN_4393 GBV_ILN_4700 44.87 ASE AR 27 2013 10 14 05 3852-3859 |
allfieldsSound |
10.1007/s00464-013-2994-4 doi (DE-627)SPR006300804 (SPR)s00464-013-2994-4-e DE-627 ger DE-627 rakwb eng 610 ASE 610 ASE 44.87 bkl Rothmund, Ralf verfasserin aut A prospective, randomized clinical comparison between UltraCision and the novel sealing and cutting device BiCision in patients with laparoscopic supracervical hysterectomy 2013 Text txt rdacontent Computermedien c rdamedia Online-Ressource cr rdacarrier Background Various surgical procedures for hysterectomy exist; with laparoscopic supracervical hysterectomy (LASH) becoming an established option in recent years. Therefore, energy-based technologies for rapid tissue sealing and cutting are in the focus of surgeons. The aim of this trial was to prove or disprove investigated noninferiority of the novel device BiCision in comparison to the widely used UltraCision in a routine procedure (www.clinicaltrials.gov; study identifier NCT01806012). Methods Thirty LASH procedures were performed with UltraCision and BiCision after randomization of the preparation sides. The primary end point was the resection time per side and instrument. The instruments were also compared concerning blood loss and coagulation and cutting qualities as well as postoperative complications. The patients were followed for 3 months. Results Mean preparation time per side was 8.8 ± 1.8 min for BiCision and 8.3 ± 1.9 min for UltraCision (p = 0.31), which was not significantly different. Both instruments achieved complete transection without the need of additional cutting attempts. BiCision was significantly superior regarding the number of coagulations for complete hemostasis before and after the removal of the uterine corpus (before: 6.9 ± 4.8 for BiCision and 8.6 ± 4.1 for UltraCision, p = 0.047; after: 5.4 ± 1.2 for BiCision and 8.6 ± 3.2 for UltraCision, p < 0.0001) and intraoperative blood loss (score 1.07 ± 0.25 for BiCision vs. 1.63 ± 0.49 for UltraCision, p < 0.0001). Tissue sticking to the instrument occurred less often on the BiCision side (score 0.14 ± 0.35 for BiCision vs. 0.60 ± 0.81 for UltraCision, p = 0.015). BiCision showed a significantly better fixation of the tissue (grip score 0.23 ± 0.43 for BiCision vs. 1.00 ± 0.74 for UltraCision, p < 0.0001). No intraoperative or postoperative complications were seen for both instruments. Conclusions The efficacy and quality of vessel sealing and cutting with BiCision is not inferior to the UltraCision device. Resection time was comparable, and complete hemostasis could be achieved faster in a clinical setting. Therefore, BiCision is at least as reliable as UltraCision for laparoscopic indications. Bipolar electrocoagulation (dpeaa)DE-He213 Supracervical hysterectomy (dpeaa)DE-He213 Vessel sealing (dpeaa)DE-He213 Szyrach, Mara verfasserin aut Reda, Ali verfasserin aut Enderle, Markus D. verfasserin aut Neugebauer, Alexander verfasserin aut Taran, Florin-Andrei verfasserin aut Brucker, Sara verfasserin aut Hausch, Andrea verfasserin aut Wallwiener, Christian verfasserin aut Kraemer, Bernhard verfasserin aut Enthalten in Surgical endoscopy and other interventional techniques New York, NY : Springer, 1987 27(2013), 10 vom: 14. Mai, Seite 3852-3859 (DE-627)254909620 (DE-600)1463171-4 1432-2218 nnns volume:27 year:2013 number:10 day:14 month:05 pages:3852-3859 https://dx.doi.org/10.1007/s00464-013-2994-4 lizenzpflichtig Volltext GBV_USEFLAG_A SYSFLAG_A GBV_SPRINGER SSG-OLC-PHA GBV_ILN_11 GBV_ILN_20 GBV_ILN_22 GBV_ILN_23 GBV_ILN_24 GBV_ILN_31 GBV_ILN_32 GBV_ILN_39 GBV_ILN_40 GBV_ILN_60 GBV_ILN_62 GBV_ILN_63 GBV_ILN_69 GBV_ILN_70 GBV_ILN_73 GBV_ILN_74 GBV_ILN_90 GBV_ILN_95 GBV_ILN_100 GBV_ILN_101 GBV_ILN_105 GBV_ILN_110 GBV_ILN_120 GBV_ILN_138 GBV_ILN_150 GBV_ILN_151 GBV_ILN_152 GBV_ILN_161 GBV_ILN_170 GBV_ILN_171 GBV_ILN_187 GBV_ILN_213 GBV_ILN_224 GBV_ILN_230 GBV_ILN_250 GBV_ILN_267 GBV_ILN_281 GBV_ILN_285 GBV_ILN_293 GBV_ILN_370 GBV_ILN_602 GBV_ILN_636 GBV_ILN_702 GBV_ILN_711 GBV_ILN_2001 GBV_ILN_2003 GBV_ILN_2004 GBV_ILN_2005 GBV_ILN_2006 GBV_ILN_2007 GBV_ILN_2008 GBV_ILN_2009 GBV_ILN_2010 GBV_ILN_2011 GBV_ILN_2014 GBV_ILN_2015 GBV_ILN_2020 GBV_ILN_2021 GBV_ILN_2025 GBV_ILN_2026 GBV_ILN_2027 GBV_ILN_2031 GBV_ILN_2034 GBV_ILN_2037 GBV_ILN_2038 GBV_ILN_2044 GBV_ILN_2048 GBV_ILN_2049 GBV_ILN_2050 GBV_ILN_2055 GBV_ILN_2057 GBV_ILN_2059 GBV_ILN_2061 GBV_ILN_2064 GBV_ILN_2065 GBV_ILN_2068 GBV_ILN_2070 GBV_ILN_2086 GBV_ILN_2093 GBV_ILN_2106 GBV_ILN_2107 GBV_ILN_2108 GBV_ILN_2110 GBV_ILN_2111 GBV_ILN_2113 GBV_ILN_2116 GBV_ILN_2118 GBV_ILN_2119 GBV_ILN_2129 GBV_ILN_2143 GBV_ILN_2144 GBV_ILN_2147 GBV_ILN_2153 GBV_ILN_2188 GBV_ILN_2190 GBV_ILN_2232 GBV_ILN_2336 GBV_ILN_2446 GBV_ILN_2470 GBV_ILN_2472 GBV_ILN_2507 GBV_ILN_2522 GBV_ILN_2548 GBV_ILN_4012 GBV_ILN_4035 GBV_ILN_4037 GBV_ILN_4046 GBV_ILN_4112 GBV_ILN_4125 GBV_ILN_4126 GBV_ILN_4242 GBV_ILN_4246 GBV_ILN_4249 GBV_ILN_4251 GBV_ILN_4305 GBV_ILN_4306 GBV_ILN_4307 GBV_ILN_4313 GBV_ILN_4322 GBV_ILN_4323 GBV_ILN_4324 GBV_ILN_4326 GBV_ILN_4328 GBV_ILN_4333 GBV_ILN_4334 GBV_ILN_4335 GBV_ILN_4336 GBV_ILN_4338 GBV_ILN_4393 GBV_ILN_4700 44.87 ASE AR 27 2013 10 14 05 3852-3859 |
language |
English |
source |
Enthalten in Surgical endoscopy and other interventional techniques 27(2013), 10 vom: 14. Mai, Seite 3852-3859 volume:27 year:2013 number:10 day:14 month:05 pages:3852-3859 |
sourceStr |
Enthalten in Surgical endoscopy and other interventional techniques 27(2013), 10 vom: 14. Mai, Seite 3852-3859 volume:27 year:2013 number:10 day:14 month:05 pages:3852-3859 |
format_phy_str_mv |
Article |
institution |
findex.gbv.de |
topic_facet |
Bipolar electrocoagulation Supracervical hysterectomy Vessel sealing |
dewey-raw |
610 |
isfreeaccess_bool |
false |
container_title |
Surgical endoscopy and other interventional techniques |
authorswithroles_txt_mv |
Rothmund, Ralf @@aut@@ Szyrach, Mara @@aut@@ Reda, Ali @@aut@@ Enderle, Markus D. @@aut@@ Neugebauer, Alexander @@aut@@ Taran, Florin-Andrei @@aut@@ Brucker, Sara @@aut@@ Hausch, Andrea @@aut@@ Wallwiener, Christian @@aut@@ Kraemer, Bernhard @@aut@@ |
publishDateDaySort_date |
2013-05-14T00:00:00Z |
hierarchy_top_id |
254909620 |
dewey-sort |
3610 |
id |
SPR006300804 |
language_de |
englisch |
fullrecord |
<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim"><record><leader>01000caa a22002652 4500</leader><controlfield tag="001">SPR006300804</controlfield><controlfield tag="003">DE-627</controlfield><controlfield tag="005">20230520001314.0</controlfield><controlfield tag="007">cr uuu---uuuuu</controlfield><controlfield tag="008">201002s2013 xx |||||o 00| ||eng c</controlfield><datafield tag="024" ind1="7" ind2=" "><subfield code="a">10.1007/s00464-013-2994-4</subfield><subfield code="2">doi</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-627)SPR006300804</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(SPR)s00464-013-2994-4-e</subfield></datafield><datafield tag="040" ind1=" " ind2=" "><subfield code="a">DE-627</subfield><subfield code="b">ger</subfield><subfield code="c">DE-627</subfield><subfield code="e">rakwb</subfield></datafield><datafield tag="041" ind1=" " ind2=" "><subfield code="a">eng</subfield></datafield><datafield tag="082" ind1="0" ind2="4"><subfield code="a">610</subfield><subfield code="q">ASE</subfield></datafield><datafield tag="082" ind1="0" ind2="4"><subfield code="a">610</subfield><subfield code="q">ASE</subfield></datafield><datafield tag="084" ind1=" " ind2=" "><subfield code="a">44.87</subfield><subfield code="2">bkl</subfield></datafield><datafield tag="100" ind1="1" ind2=" "><subfield code="a">Rothmund, Ralf</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="245" ind1="1" ind2="2"><subfield code="a">A prospective, randomized clinical comparison between UltraCision and the novel sealing and cutting device BiCision in patients with laparoscopic supracervical hysterectomy</subfield></datafield><datafield tag="264" ind1=" " ind2="1"><subfield code="c">2013</subfield></datafield><datafield tag="336" ind1=" " ind2=" "><subfield code="a">Text</subfield><subfield code="b">txt</subfield><subfield code="2">rdacontent</subfield></datafield><datafield tag="337" ind1=" " ind2=" "><subfield code="a">Computermedien</subfield><subfield code="b">c</subfield><subfield code="2">rdamedia</subfield></datafield><datafield tag="338" ind1=" " ind2=" "><subfield code="a">Online-Ressource</subfield><subfield code="b">cr</subfield><subfield code="2">rdacarrier</subfield></datafield><datafield tag="520" ind1=" " ind2=" "><subfield code="a">Background Various surgical procedures for hysterectomy exist; with laparoscopic supracervical hysterectomy (LASH) becoming an established option in recent years. Therefore, energy-based technologies for rapid tissue sealing and cutting are in the focus of surgeons. The aim of this trial was to prove or disprove investigated noninferiority of the novel device BiCision in comparison to the widely used UltraCision in a routine procedure (www.clinicaltrials.gov; study identifier NCT01806012). Methods Thirty LASH procedures were performed with UltraCision and BiCision after randomization of the preparation sides. The primary end point was the resection time per side and instrument. The instruments were also compared concerning blood loss and coagulation and cutting qualities as well as postoperative complications. The patients were followed for 3 months. Results Mean preparation time per side was 8.8 ± 1.8 min for BiCision and 8.3 ± 1.9 min for UltraCision (p = 0.31), which was not significantly different. Both instruments achieved complete transection without the need of additional cutting attempts. BiCision was significantly superior regarding the number of coagulations for complete hemostasis before and after the removal of the uterine corpus (before: 6.9 ± 4.8 for BiCision and 8.6 ± 4.1 for UltraCision, p = 0.047; after: 5.4 ± 1.2 for BiCision and 8.6 ± 3.2 for UltraCision, p < 0.0001) and intraoperative blood loss (score 1.07 ± 0.25 for BiCision vs. 1.63 ± 0.49 for UltraCision, p < 0.0001). Tissue sticking to the instrument occurred less often on the BiCision side (score 0.14 ± 0.35 for BiCision vs. 0.60 ± 0.81 for UltraCision, p = 0.015). BiCision showed a significantly better fixation of the tissue (grip score 0.23 ± 0.43 for BiCision vs. 1.00 ± 0.74 for UltraCision, p < 0.0001). No intraoperative or postoperative complications were seen for both instruments. Conclusions The efficacy and quality of vessel sealing and cutting with BiCision is not inferior to the UltraCision device. Resection time was comparable, and complete hemostasis could be achieved faster in a clinical setting. Therefore, BiCision is at least as reliable as UltraCision for laparoscopic indications.</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Bipolar electrocoagulation</subfield><subfield code="7">(dpeaa)DE-He213</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Supracervical hysterectomy</subfield><subfield code="7">(dpeaa)DE-He213</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Vessel sealing</subfield><subfield code="7">(dpeaa)DE-He213</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Szyrach, Mara</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Reda, Ali</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Enderle, Markus D.</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Neugebauer, Alexander</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Taran, Florin-Andrei</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Brucker, Sara</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Hausch, Andrea</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Wallwiener, Christian</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Kraemer, Bernhard</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="773" ind1="0" ind2="8"><subfield code="i">Enthalten in</subfield><subfield code="t">Surgical endoscopy and other interventional techniques</subfield><subfield code="d">New York, NY : Springer, 1987</subfield><subfield code="g">27(2013), 10 vom: 14. Mai, Seite 3852-3859</subfield><subfield code="w">(DE-627)254909620</subfield><subfield code="w">(DE-600)1463171-4</subfield><subfield code="x">1432-2218</subfield><subfield code="7">nnns</subfield></datafield><datafield tag="773" ind1="1" ind2="8"><subfield code="g">volume:27</subfield><subfield code="g">year:2013</subfield><subfield code="g">number:10</subfield><subfield code="g">day:14</subfield><subfield code="g">month:05</subfield><subfield code="g">pages:3852-3859</subfield></datafield><datafield tag="856" ind1="4" ind2="0"><subfield code="u">https://dx.doi.org/10.1007/s00464-013-2994-4</subfield><subfield code="z">lizenzpflichtig</subfield><subfield code="3">Volltext</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_USEFLAG_A</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">SYSFLAG_A</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_SPRINGER</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">SSG-OLC-PHA</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_11</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_20</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_22</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_23</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_24</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_31</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_32</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_39</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_40</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_60</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_62</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_63</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_69</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_70</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_73</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_74</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_90</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_95</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_100</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_101</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_105</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_110</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_120</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_138</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_150</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_151</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_152</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_161</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_170</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_171</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_187</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_213</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_224</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_230</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_250</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_267</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_281</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_285</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_293</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_370</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_602</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_636</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_702</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_711</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2001</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2003</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2004</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2005</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2006</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2007</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2008</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2009</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2010</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2011</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2014</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2015</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2020</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2021</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2025</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2026</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2027</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2031</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2034</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2037</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2038</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2044</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2048</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2049</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2050</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2055</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2057</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2059</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2061</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2064</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2065</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2068</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2070</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2086</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2093</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2106</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2107</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2108</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2110</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2111</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2113</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2116</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2118</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2119</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2129</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2143</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2144</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2147</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2153</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2188</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2190</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2232</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2336</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2446</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2470</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2472</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2507</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2522</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2548</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4012</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4035</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4037</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4046</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4112</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4125</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4126</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4242</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4246</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4249</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4251</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4305</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4306</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4307</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4313</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4322</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4323</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4324</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4326</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4328</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4333</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4334</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4335</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4336</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4338</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4393</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4700</subfield></datafield><datafield tag="936" ind1="b" ind2="k"><subfield code="a">44.87</subfield><subfield code="q">ASE</subfield></datafield><datafield tag="951" ind1=" " ind2=" "><subfield code="a">AR</subfield></datafield><datafield tag="952" ind1=" " ind2=" "><subfield code="d">27</subfield><subfield code="j">2013</subfield><subfield code="e">10</subfield><subfield code="b">14</subfield><subfield code="c">05</subfield><subfield code="h">3852-3859</subfield></datafield></record></collection>
|
author |
Rothmund, Ralf |
spellingShingle |
Rothmund, Ralf ddc 610 bkl 44.87 misc Bipolar electrocoagulation misc Supracervical hysterectomy misc Vessel sealing A prospective, randomized clinical comparison between UltraCision and the novel sealing and cutting device BiCision in patients with laparoscopic supracervical hysterectomy |
authorStr |
Rothmund, Ralf |
ppnlink_with_tag_str_mv |
@@773@@(DE-627)254909620 |
format |
electronic Article |
dewey-ones |
610 - Medicine & health |
delete_txt_mv |
keep |
author_role |
aut aut aut aut aut aut aut aut aut aut |
collection |
springer |
remote_str |
true |
illustrated |
Not Illustrated |
issn |
1432-2218 |
topic_title |
610 ASE 44.87 bkl A prospective, randomized clinical comparison between UltraCision and the novel sealing and cutting device BiCision in patients with laparoscopic supracervical hysterectomy Bipolar electrocoagulation (dpeaa)DE-He213 Supracervical hysterectomy (dpeaa)DE-He213 Vessel sealing (dpeaa)DE-He213 |
topic |
ddc 610 bkl 44.87 misc Bipolar electrocoagulation misc Supracervical hysterectomy misc Vessel sealing |
topic_unstemmed |
ddc 610 bkl 44.87 misc Bipolar electrocoagulation misc Supracervical hysterectomy misc Vessel sealing |
topic_browse |
ddc 610 bkl 44.87 misc Bipolar electrocoagulation misc Supracervical hysterectomy misc Vessel sealing |
format_facet |
Elektronische Aufsätze Aufsätze Elektronische Ressource |
format_main_str_mv |
Text Zeitschrift/Artikel |
carriertype_str_mv |
cr |
hierarchy_parent_title |
Surgical endoscopy and other interventional techniques |
hierarchy_parent_id |
254909620 |
dewey-tens |
610 - Medicine & health |
hierarchy_top_title |
Surgical endoscopy and other interventional techniques |
isfreeaccess_txt |
false |
familylinks_str_mv |
(DE-627)254909620 (DE-600)1463171-4 |
title |
A prospective, randomized clinical comparison between UltraCision and the novel sealing and cutting device BiCision in patients with laparoscopic supracervical hysterectomy |
ctrlnum |
(DE-627)SPR006300804 (SPR)s00464-013-2994-4-e |
title_full |
A prospective, randomized clinical comparison between UltraCision and the novel sealing and cutting device BiCision in patients with laparoscopic supracervical hysterectomy |
author_sort |
Rothmund, Ralf |
journal |
Surgical endoscopy and other interventional techniques |
journalStr |
Surgical endoscopy and other interventional techniques |
lang_code |
eng |
isOA_bool |
false |
dewey-hundreds |
600 - Technology |
recordtype |
marc |
publishDateSort |
2013 |
contenttype_str_mv |
txt |
container_start_page |
3852 |
author_browse |
Rothmund, Ralf Szyrach, Mara Reda, Ali Enderle, Markus D. Neugebauer, Alexander Taran, Florin-Andrei Brucker, Sara Hausch, Andrea Wallwiener, Christian Kraemer, Bernhard |
container_volume |
27 |
class |
610 ASE 44.87 bkl |
format_se |
Elektronische Aufsätze |
author-letter |
Rothmund, Ralf |
doi_str_mv |
10.1007/s00464-013-2994-4 |
dewey-full |
610 |
author2-role |
verfasserin |
title_sort |
prospective, randomized clinical comparison between ultracision and the novel sealing and cutting device bicision in patients with laparoscopic supracervical hysterectomy |
title_auth |
A prospective, randomized clinical comparison between UltraCision and the novel sealing and cutting device BiCision in patients with laparoscopic supracervical hysterectomy |
abstract |
Background Various surgical procedures for hysterectomy exist; with laparoscopic supracervical hysterectomy (LASH) becoming an established option in recent years. Therefore, energy-based technologies for rapid tissue sealing and cutting are in the focus of surgeons. The aim of this trial was to prove or disprove investigated noninferiority of the novel device BiCision in comparison to the widely used UltraCision in a routine procedure (www.clinicaltrials.gov; study identifier NCT01806012). Methods Thirty LASH procedures were performed with UltraCision and BiCision after randomization of the preparation sides. The primary end point was the resection time per side and instrument. The instruments were also compared concerning blood loss and coagulation and cutting qualities as well as postoperative complications. The patients were followed for 3 months. Results Mean preparation time per side was 8.8 ± 1.8 min for BiCision and 8.3 ± 1.9 min for UltraCision (p = 0.31), which was not significantly different. Both instruments achieved complete transection without the need of additional cutting attempts. BiCision was significantly superior regarding the number of coagulations for complete hemostasis before and after the removal of the uterine corpus (before: 6.9 ± 4.8 for BiCision and 8.6 ± 4.1 for UltraCision, p = 0.047; after: 5.4 ± 1.2 for BiCision and 8.6 ± 3.2 for UltraCision, p < 0.0001) and intraoperative blood loss (score 1.07 ± 0.25 for BiCision vs. 1.63 ± 0.49 for UltraCision, p < 0.0001). Tissue sticking to the instrument occurred less often on the BiCision side (score 0.14 ± 0.35 for BiCision vs. 0.60 ± 0.81 for UltraCision, p = 0.015). BiCision showed a significantly better fixation of the tissue (grip score 0.23 ± 0.43 for BiCision vs. 1.00 ± 0.74 for UltraCision, p < 0.0001). No intraoperative or postoperative complications were seen for both instruments. Conclusions The efficacy and quality of vessel sealing and cutting with BiCision is not inferior to the UltraCision device. Resection time was comparable, and complete hemostasis could be achieved faster in a clinical setting. Therefore, BiCision is at least as reliable as UltraCision for laparoscopic indications. |
abstractGer |
Background Various surgical procedures for hysterectomy exist; with laparoscopic supracervical hysterectomy (LASH) becoming an established option in recent years. Therefore, energy-based technologies for rapid tissue sealing and cutting are in the focus of surgeons. The aim of this trial was to prove or disprove investigated noninferiority of the novel device BiCision in comparison to the widely used UltraCision in a routine procedure (www.clinicaltrials.gov; study identifier NCT01806012). Methods Thirty LASH procedures were performed with UltraCision and BiCision after randomization of the preparation sides. The primary end point was the resection time per side and instrument. The instruments were also compared concerning blood loss and coagulation and cutting qualities as well as postoperative complications. The patients were followed for 3 months. Results Mean preparation time per side was 8.8 ± 1.8 min for BiCision and 8.3 ± 1.9 min for UltraCision (p = 0.31), which was not significantly different. Both instruments achieved complete transection without the need of additional cutting attempts. BiCision was significantly superior regarding the number of coagulations for complete hemostasis before and after the removal of the uterine corpus (before: 6.9 ± 4.8 for BiCision and 8.6 ± 4.1 for UltraCision, p = 0.047; after: 5.4 ± 1.2 for BiCision and 8.6 ± 3.2 for UltraCision, p < 0.0001) and intraoperative blood loss (score 1.07 ± 0.25 for BiCision vs. 1.63 ± 0.49 for UltraCision, p < 0.0001). Tissue sticking to the instrument occurred less often on the BiCision side (score 0.14 ± 0.35 for BiCision vs. 0.60 ± 0.81 for UltraCision, p = 0.015). BiCision showed a significantly better fixation of the tissue (grip score 0.23 ± 0.43 for BiCision vs. 1.00 ± 0.74 for UltraCision, p < 0.0001). No intraoperative or postoperative complications were seen for both instruments. Conclusions The efficacy and quality of vessel sealing and cutting with BiCision is not inferior to the UltraCision device. Resection time was comparable, and complete hemostasis could be achieved faster in a clinical setting. Therefore, BiCision is at least as reliable as UltraCision for laparoscopic indications. |
abstract_unstemmed |
Background Various surgical procedures for hysterectomy exist; with laparoscopic supracervical hysterectomy (LASH) becoming an established option in recent years. Therefore, energy-based technologies for rapid tissue sealing and cutting are in the focus of surgeons. The aim of this trial was to prove or disprove investigated noninferiority of the novel device BiCision in comparison to the widely used UltraCision in a routine procedure (www.clinicaltrials.gov; study identifier NCT01806012). Methods Thirty LASH procedures were performed with UltraCision and BiCision after randomization of the preparation sides. The primary end point was the resection time per side and instrument. The instruments were also compared concerning blood loss and coagulation and cutting qualities as well as postoperative complications. The patients were followed for 3 months. Results Mean preparation time per side was 8.8 ± 1.8 min for BiCision and 8.3 ± 1.9 min for UltraCision (p = 0.31), which was not significantly different. Both instruments achieved complete transection without the need of additional cutting attempts. BiCision was significantly superior regarding the number of coagulations for complete hemostasis before and after the removal of the uterine corpus (before: 6.9 ± 4.8 for BiCision and 8.6 ± 4.1 for UltraCision, p = 0.047; after: 5.4 ± 1.2 for BiCision and 8.6 ± 3.2 for UltraCision, p < 0.0001) and intraoperative blood loss (score 1.07 ± 0.25 for BiCision vs. 1.63 ± 0.49 for UltraCision, p < 0.0001). Tissue sticking to the instrument occurred less often on the BiCision side (score 0.14 ± 0.35 for BiCision vs. 0.60 ± 0.81 for UltraCision, p = 0.015). BiCision showed a significantly better fixation of the tissue (grip score 0.23 ± 0.43 for BiCision vs. 1.00 ± 0.74 for UltraCision, p < 0.0001). No intraoperative or postoperative complications were seen for both instruments. Conclusions The efficacy and quality of vessel sealing and cutting with BiCision is not inferior to the UltraCision device. Resection time was comparable, and complete hemostasis could be achieved faster in a clinical setting. Therefore, BiCision is at least as reliable as UltraCision for laparoscopic indications. |
collection_details |
GBV_USEFLAG_A SYSFLAG_A GBV_SPRINGER SSG-OLC-PHA GBV_ILN_11 GBV_ILN_20 GBV_ILN_22 GBV_ILN_23 GBV_ILN_24 GBV_ILN_31 GBV_ILN_32 GBV_ILN_39 GBV_ILN_40 GBV_ILN_60 GBV_ILN_62 GBV_ILN_63 GBV_ILN_69 GBV_ILN_70 GBV_ILN_73 GBV_ILN_74 GBV_ILN_90 GBV_ILN_95 GBV_ILN_100 GBV_ILN_101 GBV_ILN_105 GBV_ILN_110 GBV_ILN_120 GBV_ILN_138 GBV_ILN_150 GBV_ILN_151 GBV_ILN_152 GBV_ILN_161 GBV_ILN_170 GBV_ILN_171 GBV_ILN_187 GBV_ILN_213 GBV_ILN_224 GBV_ILN_230 GBV_ILN_250 GBV_ILN_267 GBV_ILN_281 GBV_ILN_285 GBV_ILN_293 GBV_ILN_370 GBV_ILN_602 GBV_ILN_636 GBV_ILN_702 GBV_ILN_711 GBV_ILN_2001 GBV_ILN_2003 GBV_ILN_2004 GBV_ILN_2005 GBV_ILN_2006 GBV_ILN_2007 GBV_ILN_2008 GBV_ILN_2009 GBV_ILN_2010 GBV_ILN_2011 GBV_ILN_2014 GBV_ILN_2015 GBV_ILN_2020 GBV_ILN_2021 GBV_ILN_2025 GBV_ILN_2026 GBV_ILN_2027 GBV_ILN_2031 GBV_ILN_2034 GBV_ILN_2037 GBV_ILN_2038 GBV_ILN_2044 GBV_ILN_2048 GBV_ILN_2049 GBV_ILN_2050 GBV_ILN_2055 GBV_ILN_2057 GBV_ILN_2059 GBV_ILN_2061 GBV_ILN_2064 GBV_ILN_2065 GBV_ILN_2068 GBV_ILN_2070 GBV_ILN_2086 GBV_ILN_2093 GBV_ILN_2106 GBV_ILN_2107 GBV_ILN_2108 GBV_ILN_2110 GBV_ILN_2111 GBV_ILN_2113 GBV_ILN_2116 GBV_ILN_2118 GBV_ILN_2119 GBV_ILN_2129 GBV_ILN_2143 GBV_ILN_2144 GBV_ILN_2147 GBV_ILN_2153 GBV_ILN_2188 GBV_ILN_2190 GBV_ILN_2232 GBV_ILN_2336 GBV_ILN_2446 GBV_ILN_2470 GBV_ILN_2472 GBV_ILN_2507 GBV_ILN_2522 GBV_ILN_2548 GBV_ILN_4012 GBV_ILN_4035 GBV_ILN_4037 GBV_ILN_4046 GBV_ILN_4112 GBV_ILN_4125 GBV_ILN_4126 GBV_ILN_4242 GBV_ILN_4246 GBV_ILN_4249 GBV_ILN_4251 GBV_ILN_4305 GBV_ILN_4306 GBV_ILN_4307 GBV_ILN_4313 GBV_ILN_4322 GBV_ILN_4323 GBV_ILN_4324 GBV_ILN_4326 GBV_ILN_4328 GBV_ILN_4333 GBV_ILN_4334 GBV_ILN_4335 GBV_ILN_4336 GBV_ILN_4338 GBV_ILN_4393 GBV_ILN_4700 |
container_issue |
10 |
title_short |
A prospective, randomized clinical comparison between UltraCision and the novel sealing and cutting device BiCision in patients with laparoscopic supracervical hysterectomy |
url |
https://dx.doi.org/10.1007/s00464-013-2994-4 |
remote_bool |
true |
author2 |
Szyrach, Mara Reda, Ali Enderle, Markus D. Neugebauer, Alexander Taran, Florin-Andrei Brucker, Sara Hausch, Andrea Wallwiener, Christian Kraemer, Bernhard |
author2Str |
Szyrach, Mara Reda, Ali Enderle, Markus D. Neugebauer, Alexander Taran, Florin-Andrei Brucker, Sara Hausch, Andrea Wallwiener, Christian Kraemer, Bernhard |
ppnlink |
254909620 |
mediatype_str_mv |
c |
isOA_txt |
false |
hochschulschrift_bool |
false |
doi_str |
10.1007/s00464-013-2994-4 |
up_date |
2024-07-03T22:08:35.779Z |
_version_ |
1803597398183772160 |
fullrecord_marcxml |
<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim"><record><leader>01000caa a22002652 4500</leader><controlfield tag="001">SPR006300804</controlfield><controlfield tag="003">DE-627</controlfield><controlfield tag="005">20230520001314.0</controlfield><controlfield tag="007">cr uuu---uuuuu</controlfield><controlfield tag="008">201002s2013 xx |||||o 00| ||eng c</controlfield><datafield tag="024" ind1="7" ind2=" "><subfield code="a">10.1007/s00464-013-2994-4</subfield><subfield code="2">doi</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-627)SPR006300804</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(SPR)s00464-013-2994-4-e</subfield></datafield><datafield tag="040" ind1=" " ind2=" "><subfield code="a">DE-627</subfield><subfield code="b">ger</subfield><subfield code="c">DE-627</subfield><subfield code="e">rakwb</subfield></datafield><datafield tag="041" ind1=" " ind2=" "><subfield code="a">eng</subfield></datafield><datafield tag="082" ind1="0" ind2="4"><subfield code="a">610</subfield><subfield code="q">ASE</subfield></datafield><datafield tag="082" ind1="0" ind2="4"><subfield code="a">610</subfield><subfield code="q">ASE</subfield></datafield><datafield tag="084" ind1=" " ind2=" "><subfield code="a">44.87</subfield><subfield code="2">bkl</subfield></datafield><datafield tag="100" ind1="1" ind2=" "><subfield code="a">Rothmund, Ralf</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="245" ind1="1" ind2="2"><subfield code="a">A prospective, randomized clinical comparison between UltraCision and the novel sealing and cutting device BiCision in patients with laparoscopic supracervical hysterectomy</subfield></datafield><datafield tag="264" ind1=" " ind2="1"><subfield code="c">2013</subfield></datafield><datafield tag="336" ind1=" " ind2=" "><subfield code="a">Text</subfield><subfield code="b">txt</subfield><subfield code="2">rdacontent</subfield></datafield><datafield tag="337" ind1=" " ind2=" "><subfield code="a">Computermedien</subfield><subfield code="b">c</subfield><subfield code="2">rdamedia</subfield></datafield><datafield tag="338" ind1=" " ind2=" "><subfield code="a">Online-Ressource</subfield><subfield code="b">cr</subfield><subfield code="2">rdacarrier</subfield></datafield><datafield tag="520" ind1=" " ind2=" "><subfield code="a">Background Various surgical procedures for hysterectomy exist; with laparoscopic supracervical hysterectomy (LASH) becoming an established option in recent years. Therefore, energy-based technologies for rapid tissue sealing and cutting are in the focus of surgeons. The aim of this trial was to prove or disprove investigated noninferiority of the novel device BiCision in comparison to the widely used UltraCision in a routine procedure (www.clinicaltrials.gov; study identifier NCT01806012). Methods Thirty LASH procedures were performed with UltraCision and BiCision after randomization of the preparation sides. The primary end point was the resection time per side and instrument. The instruments were also compared concerning blood loss and coagulation and cutting qualities as well as postoperative complications. The patients were followed for 3 months. Results Mean preparation time per side was 8.8 ± 1.8 min for BiCision and 8.3 ± 1.9 min for UltraCision (p = 0.31), which was not significantly different. Both instruments achieved complete transection without the need of additional cutting attempts. BiCision was significantly superior regarding the number of coagulations for complete hemostasis before and after the removal of the uterine corpus (before: 6.9 ± 4.8 for BiCision and 8.6 ± 4.1 for UltraCision, p = 0.047; after: 5.4 ± 1.2 for BiCision and 8.6 ± 3.2 for UltraCision, p < 0.0001) and intraoperative blood loss (score 1.07 ± 0.25 for BiCision vs. 1.63 ± 0.49 for UltraCision, p < 0.0001). Tissue sticking to the instrument occurred less often on the BiCision side (score 0.14 ± 0.35 for BiCision vs. 0.60 ± 0.81 for UltraCision, p = 0.015). BiCision showed a significantly better fixation of the tissue (grip score 0.23 ± 0.43 for BiCision vs. 1.00 ± 0.74 for UltraCision, p < 0.0001). No intraoperative or postoperative complications were seen for both instruments. Conclusions The efficacy and quality of vessel sealing and cutting with BiCision is not inferior to the UltraCision device. Resection time was comparable, and complete hemostasis could be achieved faster in a clinical setting. Therefore, BiCision is at least as reliable as UltraCision for laparoscopic indications.</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Bipolar electrocoagulation</subfield><subfield code="7">(dpeaa)DE-He213</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Supracervical hysterectomy</subfield><subfield code="7">(dpeaa)DE-He213</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Vessel sealing</subfield><subfield code="7">(dpeaa)DE-He213</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Szyrach, Mara</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Reda, Ali</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Enderle, Markus D.</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Neugebauer, Alexander</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Taran, Florin-Andrei</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Brucker, Sara</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Hausch, Andrea</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Wallwiener, Christian</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Kraemer, Bernhard</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="773" ind1="0" ind2="8"><subfield code="i">Enthalten in</subfield><subfield code="t">Surgical endoscopy and other interventional techniques</subfield><subfield code="d">New York, NY : Springer, 1987</subfield><subfield code="g">27(2013), 10 vom: 14. Mai, Seite 3852-3859</subfield><subfield code="w">(DE-627)254909620</subfield><subfield code="w">(DE-600)1463171-4</subfield><subfield code="x">1432-2218</subfield><subfield code="7">nnns</subfield></datafield><datafield tag="773" ind1="1" ind2="8"><subfield code="g">volume:27</subfield><subfield code="g">year:2013</subfield><subfield code="g">number:10</subfield><subfield code="g">day:14</subfield><subfield code="g">month:05</subfield><subfield code="g">pages:3852-3859</subfield></datafield><datafield tag="856" ind1="4" ind2="0"><subfield code="u">https://dx.doi.org/10.1007/s00464-013-2994-4</subfield><subfield code="z">lizenzpflichtig</subfield><subfield code="3">Volltext</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_USEFLAG_A</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">SYSFLAG_A</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_SPRINGER</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">SSG-OLC-PHA</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_11</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_20</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_22</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_23</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_24</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_31</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_32</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_39</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_40</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_60</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_62</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_63</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_69</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_70</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_73</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_74</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_90</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_95</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_100</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_101</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_105</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_110</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_120</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_138</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_150</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_151</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_152</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_161</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_170</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_171</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_187</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_213</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_224</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_230</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_250</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_267</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_281</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_285</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_293</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_370</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_602</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_636</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_702</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_711</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2001</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2003</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2004</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2005</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2006</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2007</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2008</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2009</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2010</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2011</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2014</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2015</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2020</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2021</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2025</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2026</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2027</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2031</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2034</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2037</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2038</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2044</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2048</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2049</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2050</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2055</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2057</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2059</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2061</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2064</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2065</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2068</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2070</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2086</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2093</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2106</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2107</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2108</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2110</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2111</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2113</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2116</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2118</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2119</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2129</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2143</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2144</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2147</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2153</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2188</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2190</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2232</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2336</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2446</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2470</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2472</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2507</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2522</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2548</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4012</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4035</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4037</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4046</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4112</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4125</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4126</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4242</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4246</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4249</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4251</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4305</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4306</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4307</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4313</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4322</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4323</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4324</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4326</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4328</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4333</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4334</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4335</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4336</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4338</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4393</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4700</subfield></datafield><datafield tag="936" ind1="b" ind2="k"><subfield code="a">44.87</subfield><subfield code="q">ASE</subfield></datafield><datafield tag="951" ind1=" " ind2=" "><subfield code="a">AR</subfield></datafield><datafield tag="952" ind1=" " ind2=" "><subfield code="d">27</subfield><subfield code="j">2013</subfield><subfield code="e">10</subfield><subfield code="b">14</subfield><subfield code="c">05</subfield><subfield code="h">3852-3859</subfield></datafield></record></collection>
|
score |
7.3993683 |