Fixed-Point Thermocouples in Power Plants: Long-Term Operational Experiences

Abstract For more than four years, commercially available fixed-point thermocouples have measured hot-steam temperatures in power plants. A periodic self-adjustment procedure should keep their total measuring uncertainty within 1 K. This paper gives a short introduction to the measuring system compo...
Ausführliche Beschreibung

Gespeichert in:
Autor*in:

Lehmann, H. [verfasserIn]

Format:

E-Artikel

Sprache:

Englisch

Erschienen:

2010

Schlagwörter:

Fixed-point thermocouples

Hot-steam temperature

calibration

Self-calibration

Self-adjustment

Übergeordnetes Werk:

Enthalten in: International journal of thermophysics - New York, NY : Springer Science + Business Media B.V., 1980, 31(2010), 8-9 vom: 10. Aug., Seite 1599-1607

Übergeordnetes Werk:

volume:31 ; year:2010 ; number:8-9 ; day:10 ; month:08 ; pages:1599-1607