Braun anastomosis lowers the incidence of delayed gastric emptying following pancreaticoduodenectomy: a meta-analysis
Background Delayed gastric emptying (DGE) is one of the most frequent complications following pancreaticoduodenectomy. This meta-analysis aimed to evaluate the impact of Braun enteroenterostomy on DGE following pancreaticoduodenectomy. Methods A systematic review of the literature was performed to i...
Ausführliche Beschreibung
Autor*in: |
Zhou, Yanming [verfasserIn] |
---|
Format: |
E-Artikel |
---|---|
Sprache: |
Englisch |
Erschienen: |
2018 |
---|
Schlagwörter: |
---|
Anmerkung: |
© The Author(s). 2018 |
---|
Übergeordnetes Werk: |
Enthalten in: BMC gastroenterology - London : BioMed Central, 2001, 18(2018), 1 vom: 26. Nov. |
---|---|
Übergeordnetes Werk: |
volume:18 ; year:2018 ; number:1 ; day:26 ; month:11 |
Links: |
---|
DOI / URN: |
10.1186/s12876-018-0909-5 |
---|
Katalog-ID: |
SPR027423247 |
---|
LEADER | 01000caa a22002652 4500 | ||
---|---|---|---|
001 | SPR027423247 | ||
003 | DE-627 | ||
005 | 20230519101607.0 | ||
007 | cr uuu---uuuuu | ||
008 | 201007s2018 xx |||||o 00| ||eng c | ||
024 | 7 | |a 10.1186/s12876-018-0909-5 |2 doi | |
035 | |a (DE-627)SPR027423247 | ||
035 | |a (SPR)s12876-018-0909-5-e | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
100 | 1 | |a Zhou, Yanming |e verfasserin |4 aut | |
245 | 1 | 0 | |a Braun anastomosis lowers the incidence of delayed gastric emptying following pancreaticoduodenectomy: a meta-analysis |
264 | 1 | |c 2018 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a Computermedien |b c |2 rdamedia | ||
338 | |a Online-Ressource |b cr |2 rdacarrier | ||
500 | |a © The Author(s). 2018 | ||
520 | |a Background Delayed gastric emptying (DGE) is one of the most frequent complications following pancreaticoduodenectomy. This meta-analysis aimed to evaluate the impact of Braun enteroenterostomy on DGE following pancreaticoduodenectomy. Methods A systematic review of the literature was performed to identify relevant studies. Statistical analysis was carried out using Review Manager software 5.3. Results Eleven studies involving 1672 patients (1005 in Braun group and 667 in non-Braun group) were included in the meta-analysis. Braun enteroenterostomy was associated with a statistically significant reduction in overall DGE (odds ratios [OR] 0.32, 95% confidence intervals [CI] 0.24 to 0.43; P <0.001), clinically significant DGE (OR 0.27, 95% CI 0.15 to 0.51; P <0.001), bile leak (OR 0.50, 95% CI 0.29 to 0.86; P = 0.01), and length of hospital stay (weighted mean difference -1.66, 95% CI -2.95 to 00.37; P = 0.01). Conclusions Braun enteroenterostomy minimizes the rate and severity of DGE following pancreaticoduodenectomy. | ||
650 | 4 | |a Delayed gastric emptying |7 (dpeaa)DE-He213 | |
650 | 4 | |a Braun enteroenterostomy |7 (dpeaa)DE-He213 | |
650 | 4 | |a Pancreatoduodenectomy |7 (dpeaa)DE-He213 | |
650 | 4 | |a Meta-analysis |7 (dpeaa)DE-He213 | |
700 | 1 | |a Hu, Bin |4 aut | |
700 | 1 | |a Wei, Kongyuan |4 aut | |
700 | 1 | |a Si, Xiaoying |4 aut | |
773 | 0 | 8 | |i Enthalten in |t BMC gastroenterology |d London : BioMed Central, 2001 |g 18(2018), 1 vom: 26. Nov. |w (DE-627)326643702 |w (DE-600)2041351-8 |x 1471-230X |7 nnns |
773 | 1 | 8 | |g volume:18 |g year:2018 |g number:1 |g day:26 |g month:11 |
856 | 4 | 0 | |u https://dx.doi.org/10.1186/s12876-018-0909-5 |z kostenfrei |3 Volltext |
912 | |a GBV_USEFLAG_A | ||
912 | |a SYSFLAG_A | ||
912 | |a GBV_SPRINGER | ||
912 | |a SSG-OLC-PHA | ||
912 | |a GBV_ILN_20 | ||
912 | |a GBV_ILN_22 | ||
912 | |a GBV_ILN_23 | ||
912 | |a GBV_ILN_24 | ||
912 | |a GBV_ILN_39 | ||
912 | |a GBV_ILN_40 | ||
912 | |a GBV_ILN_60 | ||
912 | |a GBV_ILN_62 | ||
912 | |a GBV_ILN_63 | ||
912 | |a GBV_ILN_65 | ||
912 | |a GBV_ILN_69 | ||
912 | |a GBV_ILN_73 | ||
912 | |a GBV_ILN_74 | ||
912 | |a GBV_ILN_95 | ||
912 | |a GBV_ILN_105 | ||
912 | |a GBV_ILN_110 | ||
912 | |a GBV_ILN_151 | ||
912 | |a GBV_ILN_161 | ||
912 | |a GBV_ILN_170 | ||
912 | |a GBV_ILN_206 | ||
912 | |a GBV_ILN_213 | ||
912 | |a GBV_ILN_230 | ||
912 | |a GBV_ILN_285 | ||
912 | |a GBV_ILN_293 | ||
912 | |a GBV_ILN_602 | ||
912 | |a GBV_ILN_702 | ||
912 | |a GBV_ILN_2001 | ||
912 | |a GBV_ILN_2003 | ||
912 | |a GBV_ILN_2005 | ||
912 | |a GBV_ILN_2006 | ||
912 | |a GBV_ILN_2008 | ||
912 | |a GBV_ILN_2009 | ||
912 | |a GBV_ILN_2010 | ||
912 | |a GBV_ILN_2011 | ||
912 | |a GBV_ILN_2014 | ||
912 | |a GBV_ILN_2015 | ||
912 | |a GBV_ILN_2020 | ||
912 | |a GBV_ILN_2021 | ||
912 | |a GBV_ILN_2025 | ||
912 | |a GBV_ILN_2031 | ||
912 | |a GBV_ILN_2038 | ||
912 | |a GBV_ILN_2044 | ||
912 | |a GBV_ILN_2048 | ||
912 | |a GBV_ILN_2050 | ||
912 | |a GBV_ILN_2055 | ||
912 | |a GBV_ILN_2056 | ||
912 | |a GBV_ILN_2057 | ||
912 | |a GBV_ILN_2061 | ||
912 | |a GBV_ILN_2111 | ||
912 | |a GBV_ILN_2113 | ||
912 | |a GBV_ILN_2190 | ||
912 | |a GBV_ILN_4012 | ||
912 | |a GBV_ILN_4037 | ||
912 | |a GBV_ILN_4112 | ||
912 | |a GBV_ILN_4125 | ||
912 | |a GBV_ILN_4126 | ||
912 | |a GBV_ILN_4249 | ||
912 | |a GBV_ILN_4305 | ||
912 | |a GBV_ILN_4306 | ||
912 | |a GBV_ILN_4307 | ||
912 | |a GBV_ILN_4313 | ||
912 | |a GBV_ILN_4322 | ||
912 | |a GBV_ILN_4323 | ||
912 | |a GBV_ILN_4324 | ||
912 | |a GBV_ILN_4325 | ||
912 | |a GBV_ILN_4338 | ||
912 | |a GBV_ILN_4367 | ||
912 | |a GBV_ILN_4700 | ||
951 | |a AR | ||
952 | |d 18 |j 2018 |e 1 |b 26 |c 11 |
author_variant |
y z yz b h bh k w kw x s xs |
---|---|
matchkey_str |
article:1471230X:2018----::ruaatmssoeshicdnefeaegsrcmtigolwnpnra |
hierarchy_sort_str |
2018 |
publishDate |
2018 |
allfields |
10.1186/s12876-018-0909-5 doi (DE-627)SPR027423247 (SPR)s12876-018-0909-5-e DE-627 ger DE-627 rakwb eng Zhou, Yanming verfasserin aut Braun anastomosis lowers the incidence of delayed gastric emptying following pancreaticoduodenectomy: a meta-analysis 2018 Text txt rdacontent Computermedien c rdamedia Online-Ressource cr rdacarrier © The Author(s). 2018 Background Delayed gastric emptying (DGE) is one of the most frequent complications following pancreaticoduodenectomy. This meta-analysis aimed to evaluate the impact of Braun enteroenterostomy on DGE following pancreaticoduodenectomy. Methods A systematic review of the literature was performed to identify relevant studies. Statistical analysis was carried out using Review Manager software 5.3. Results Eleven studies involving 1672 patients (1005 in Braun group and 667 in non-Braun group) were included in the meta-analysis. Braun enteroenterostomy was associated with a statistically significant reduction in overall DGE (odds ratios [OR] 0.32, 95% confidence intervals [CI] 0.24 to 0.43; P <0.001), clinically significant DGE (OR 0.27, 95% CI 0.15 to 0.51; P <0.001), bile leak (OR 0.50, 95% CI 0.29 to 0.86; P = 0.01), and length of hospital stay (weighted mean difference -1.66, 95% CI -2.95 to 00.37; P = 0.01). Conclusions Braun enteroenterostomy minimizes the rate and severity of DGE following pancreaticoduodenectomy. Delayed gastric emptying (dpeaa)DE-He213 Braun enteroenterostomy (dpeaa)DE-He213 Pancreatoduodenectomy (dpeaa)DE-He213 Meta-analysis (dpeaa)DE-He213 Hu, Bin aut Wei, Kongyuan aut Si, Xiaoying aut Enthalten in BMC gastroenterology London : BioMed Central, 2001 18(2018), 1 vom: 26. Nov. (DE-627)326643702 (DE-600)2041351-8 1471-230X nnns volume:18 year:2018 number:1 day:26 month:11 https://dx.doi.org/10.1186/s12876-018-0909-5 kostenfrei Volltext GBV_USEFLAG_A SYSFLAG_A GBV_SPRINGER SSG-OLC-PHA GBV_ILN_20 GBV_ILN_22 GBV_ILN_23 GBV_ILN_24 GBV_ILN_39 GBV_ILN_40 GBV_ILN_60 GBV_ILN_62 GBV_ILN_63 GBV_ILN_65 GBV_ILN_69 GBV_ILN_73 GBV_ILN_74 GBV_ILN_95 GBV_ILN_105 GBV_ILN_110 GBV_ILN_151 GBV_ILN_161 GBV_ILN_170 GBV_ILN_206 GBV_ILN_213 GBV_ILN_230 GBV_ILN_285 GBV_ILN_293 GBV_ILN_602 GBV_ILN_702 GBV_ILN_2001 GBV_ILN_2003 GBV_ILN_2005 GBV_ILN_2006 GBV_ILN_2008 GBV_ILN_2009 GBV_ILN_2010 GBV_ILN_2011 GBV_ILN_2014 GBV_ILN_2015 GBV_ILN_2020 GBV_ILN_2021 GBV_ILN_2025 GBV_ILN_2031 GBV_ILN_2038 GBV_ILN_2044 GBV_ILN_2048 GBV_ILN_2050 GBV_ILN_2055 GBV_ILN_2056 GBV_ILN_2057 GBV_ILN_2061 GBV_ILN_2111 GBV_ILN_2113 GBV_ILN_2190 GBV_ILN_4012 GBV_ILN_4037 GBV_ILN_4112 GBV_ILN_4125 GBV_ILN_4126 GBV_ILN_4249 GBV_ILN_4305 GBV_ILN_4306 GBV_ILN_4307 GBV_ILN_4313 GBV_ILN_4322 GBV_ILN_4323 GBV_ILN_4324 GBV_ILN_4325 GBV_ILN_4338 GBV_ILN_4367 GBV_ILN_4700 AR 18 2018 1 26 11 |
spelling |
10.1186/s12876-018-0909-5 doi (DE-627)SPR027423247 (SPR)s12876-018-0909-5-e DE-627 ger DE-627 rakwb eng Zhou, Yanming verfasserin aut Braun anastomosis lowers the incidence of delayed gastric emptying following pancreaticoduodenectomy: a meta-analysis 2018 Text txt rdacontent Computermedien c rdamedia Online-Ressource cr rdacarrier © The Author(s). 2018 Background Delayed gastric emptying (DGE) is one of the most frequent complications following pancreaticoduodenectomy. This meta-analysis aimed to evaluate the impact of Braun enteroenterostomy on DGE following pancreaticoduodenectomy. Methods A systematic review of the literature was performed to identify relevant studies. Statistical analysis was carried out using Review Manager software 5.3. Results Eleven studies involving 1672 patients (1005 in Braun group and 667 in non-Braun group) were included in the meta-analysis. Braun enteroenterostomy was associated with a statistically significant reduction in overall DGE (odds ratios [OR] 0.32, 95% confidence intervals [CI] 0.24 to 0.43; P <0.001), clinically significant DGE (OR 0.27, 95% CI 0.15 to 0.51; P <0.001), bile leak (OR 0.50, 95% CI 0.29 to 0.86; P = 0.01), and length of hospital stay (weighted mean difference -1.66, 95% CI -2.95 to 00.37; P = 0.01). Conclusions Braun enteroenterostomy minimizes the rate and severity of DGE following pancreaticoduodenectomy. Delayed gastric emptying (dpeaa)DE-He213 Braun enteroenterostomy (dpeaa)DE-He213 Pancreatoduodenectomy (dpeaa)DE-He213 Meta-analysis (dpeaa)DE-He213 Hu, Bin aut Wei, Kongyuan aut Si, Xiaoying aut Enthalten in BMC gastroenterology London : BioMed Central, 2001 18(2018), 1 vom: 26. Nov. (DE-627)326643702 (DE-600)2041351-8 1471-230X nnns volume:18 year:2018 number:1 day:26 month:11 https://dx.doi.org/10.1186/s12876-018-0909-5 kostenfrei Volltext GBV_USEFLAG_A SYSFLAG_A GBV_SPRINGER SSG-OLC-PHA GBV_ILN_20 GBV_ILN_22 GBV_ILN_23 GBV_ILN_24 GBV_ILN_39 GBV_ILN_40 GBV_ILN_60 GBV_ILN_62 GBV_ILN_63 GBV_ILN_65 GBV_ILN_69 GBV_ILN_73 GBV_ILN_74 GBV_ILN_95 GBV_ILN_105 GBV_ILN_110 GBV_ILN_151 GBV_ILN_161 GBV_ILN_170 GBV_ILN_206 GBV_ILN_213 GBV_ILN_230 GBV_ILN_285 GBV_ILN_293 GBV_ILN_602 GBV_ILN_702 GBV_ILN_2001 GBV_ILN_2003 GBV_ILN_2005 GBV_ILN_2006 GBV_ILN_2008 GBV_ILN_2009 GBV_ILN_2010 GBV_ILN_2011 GBV_ILN_2014 GBV_ILN_2015 GBV_ILN_2020 GBV_ILN_2021 GBV_ILN_2025 GBV_ILN_2031 GBV_ILN_2038 GBV_ILN_2044 GBV_ILN_2048 GBV_ILN_2050 GBV_ILN_2055 GBV_ILN_2056 GBV_ILN_2057 GBV_ILN_2061 GBV_ILN_2111 GBV_ILN_2113 GBV_ILN_2190 GBV_ILN_4012 GBV_ILN_4037 GBV_ILN_4112 GBV_ILN_4125 GBV_ILN_4126 GBV_ILN_4249 GBV_ILN_4305 GBV_ILN_4306 GBV_ILN_4307 GBV_ILN_4313 GBV_ILN_4322 GBV_ILN_4323 GBV_ILN_4324 GBV_ILN_4325 GBV_ILN_4338 GBV_ILN_4367 GBV_ILN_4700 AR 18 2018 1 26 11 |
allfields_unstemmed |
10.1186/s12876-018-0909-5 doi (DE-627)SPR027423247 (SPR)s12876-018-0909-5-e DE-627 ger DE-627 rakwb eng Zhou, Yanming verfasserin aut Braun anastomosis lowers the incidence of delayed gastric emptying following pancreaticoduodenectomy: a meta-analysis 2018 Text txt rdacontent Computermedien c rdamedia Online-Ressource cr rdacarrier © The Author(s). 2018 Background Delayed gastric emptying (DGE) is one of the most frequent complications following pancreaticoduodenectomy. This meta-analysis aimed to evaluate the impact of Braun enteroenterostomy on DGE following pancreaticoduodenectomy. Methods A systematic review of the literature was performed to identify relevant studies. Statistical analysis was carried out using Review Manager software 5.3. Results Eleven studies involving 1672 patients (1005 in Braun group and 667 in non-Braun group) were included in the meta-analysis. Braun enteroenterostomy was associated with a statistically significant reduction in overall DGE (odds ratios [OR] 0.32, 95% confidence intervals [CI] 0.24 to 0.43; P <0.001), clinically significant DGE (OR 0.27, 95% CI 0.15 to 0.51; P <0.001), bile leak (OR 0.50, 95% CI 0.29 to 0.86; P = 0.01), and length of hospital stay (weighted mean difference -1.66, 95% CI -2.95 to 00.37; P = 0.01). Conclusions Braun enteroenterostomy minimizes the rate and severity of DGE following pancreaticoduodenectomy. Delayed gastric emptying (dpeaa)DE-He213 Braun enteroenterostomy (dpeaa)DE-He213 Pancreatoduodenectomy (dpeaa)DE-He213 Meta-analysis (dpeaa)DE-He213 Hu, Bin aut Wei, Kongyuan aut Si, Xiaoying aut Enthalten in BMC gastroenterology London : BioMed Central, 2001 18(2018), 1 vom: 26. Nov. (DE-627)326643702 (DE-600)2041351-8 1471-230X nnns volume:18 year:2018 number:1 day:26 month:11 https://dx.doi.org/10.1186/s12876-018-0909-5 kostenfrei Volltext GBV_USEFLAG_A SYSFLAG_A GBV_SPRINGER SSG-OLC-PHA GBV_ILN_20 GBV_ILN_22 GBV_ILN_23 GBV_ILN_24 GBV_ILN_39 GBV_ILN_40 GBV_ILN_60 GBV_ILN_62 GBV_ILN_63 GBV_ILN_65 GBV_ILN_69 GBV_ILN_73 GBV_ILN_74 GBV_ILN_95 GBV_ILN_105 GBV_ILN_110 GBV_ILN_151 GBV_ILN_161 GBV_ILN_170 GBV_ILN_206 GBV_ILN_213 GBV_ILN_230 GBV_ILN_285 GBV_ILN_293 GBV_ILN_602 GBV_ILN_702 GBV_ILN_2001 GBV_ILN_2003 GBV_ILN_2005 GBV_ILN_2006 GBV_ILN_2008 GBV_ILN_2009 GBV_ILN_2010 GBV_ILN_2011 GBV_ILN_2014 GBV_ILN_2015 GBV_ILN_2020 GBV_ILN_2021 GBV_ILN_2025 GBV_ILN_2031 GBV_ILN_2038 GBV_ILN_2044 GBV_ILN_2048 GBV_ILN_2050 GBV_ILN_2055 GBV_ILN_2056 GBV_ILN_2057 GBV_ILN_2061 GBV_ILN_2111 GBV_ILN_2113 GBV_ILN_2190 GBV_ILN_4012 GBV_ILN_4037 GBV_ILN_4112 GBV_ILN_4125 GBV_ILN_4126 GBV_ILN_4249 GBV_ILN_4305 GBV_ILN_4306 GBV_ILN_4307 GBV_ILN_4313 GBV_ILN_4322 GBV_ILN_4323 GBV_ILN_4324 GBV_ILN_4325 GBV_ILN_4338 GBV_ILN_4367 GBV_ILN_4700 AR 18 2018 1 26 11 |
allfieldsGer |
10.1186/s12876-018-0909-5 doi (DE-627)SPR027423247 (SPR)s12876-018-0909-5-e DE-627 ger DE-627 rakwb eng Zhou, Yanming verfasserin aut Braun anastomosis lowers the incidence of delayed gastric emptying following pancreaticoduodenectomy: a meta-analysis 2018 Text txt rdacontent Computermedien c rdamedia Online-Ressource cr rdacarrier © The Author(s). 2018 Background Delayed gastric emptying (DGE) is one of the most frequent complications following pancreaticoduodenectomy. This meta-analysis aimed to evaluate the impact of Braun enteroenterostomy on DGE following pancreaticoduodenectomy. Methods A systematic review of the literature was performed to identify relevant studies. Statistical analysis was carried out using Review Manager software 5.3. Results Eleven studies involving 1672 patients (1005 in Braun group and 667 in non-Braun group) were included in the meta-analysis. Braun enteroenterostomy was associated with a statistically significant reduction in overall DGE (odds ratios [OR] 0.32, 95% confidence intervals [CI] 0.24 to 0.43; P <0.001), clinically significant DGE (OR 0.27, 95% CI 0.15 to 0.51; P <0.001), bile leak (OR 0.50, 95% CI 0.29 to 0.86; P = 0.01), and length of hospital stay (weighted mean difference -1.66, 95% CI -2.95 to 00.37; P = 0.01). Conclusions Braun enteroenterostomy minimizes the rate and severity of DGE following pancreaticoduodenectomy. Delayed gastric emptying (dpeaa)DE-He213 Braun enteroenterostomy (dpeaa)DE-He213 Pancreatoduodenectomy (dpeaa)DE-He213 Meta-analysis (dpeaa)DE-He213 Hu, Bin aut Wei, Kongyuan aut Si, Xiaoying aut Enthalten in BMC gastroenterology London : BioMed Central, 2001 18(2018), 1 vom: 26. Nov. (DE-627)326643702 (DE-600)2041351-8 1471-230X nnns volume:18 year:2018 number:1 day:26 month:11 https://dx.doi.org/10.1186/s12876-018-0909-5 kostenfrei Volltext GBV_USEFLAG_A SYSFLAG_A GBV_SPRINGER SSG-OLC-PHA GBV_ILN_20 GBV_ILN_22 GBV_ILN_23 GBV_ILN_24 GBV_ILN_39 GBV_ILN_40 GBV_ILN_60 GBV_ILN_62 GBV_ILN_63 GBV_ILN_65 GBV_ILN_69 GBV_ILN_73 GBV_ILN_74 GBV_ILN_95 GBV_ILN_105 GBV_ILN_110 GBV_ILN_151 GBV_ILN_161 GBV_ILN_170 GBV_ILN_206 GBV_ILN_213 GBV_ILN_230 GBV_ILN_285 GBV_ILN_293 GBV_ILN_602 GBV_ILN_702 GBV_ILN_2001 GBV_ILN_2003 GBV_ILN_2005 GBV_ILN_2006 GBV_ILN_2008 GBV_ILN_2009 GBV_ILN_2010 GBV_ILN_2011 GBV_ILN_2014 GBV_ILN_2015 GBV_ILN_2020 GBV_ILN_2021 GBV_ILN_2025 GBV_ILN_2031 GBV_ILN_2038 GBV_ILN_2044 GBV_ILN_2048 GBV_ILN_2050 GBV_ILN_2055 GBV_ILN_2056 GBV_ILN_2057 GBV_ILN_2061 GBV_ILN_2111 GBV_ILN_2113 GBV_ILN_2190 GBV_ILN_4012 GBV_ILN_4037 GBV_ILN_4112 GBV_ILN_4125 GBV_ILN_4126 GBV_ILN_4249 GBV_ILN_4305 GBV_ILN_4306 GBV_ILN_4307 GBV_ILN_4313 GBV_ILN_4322 GBV_ILN_4323 GBV_ILN_4324 GBV_ILN_4325 GBV_ILN_4338 GBV_ILN_4367 GBV_ILN_4700 AR 18 2018 1 26 11 |
allfieldsSound |
10.1186/s12876-018-0909-5 doi (DE-627)SPR027423247 (SPR)s12876-018-0909-5-e DE-627 ger DE-627 rakwb eng Zhou, Yanming verfasserin aut Braun anastomosis lowers the incidence of delayed gastric emptying following pancreaticoduodenectomy: a meta-analysis 2018 Text txt rdacontent Computermedien c rdamedia Online-Ressource cr rdacarrier © The Author(s). 2018 Background Delayed gastric emptying (DGE) is one of the most frequent complications following pancreaticoduodenectomy. This meta-analysis aimed to evaluate the impact of Braun enteroenterostomy on DGE following pancreaticoduodenectomy. Methods A systematic review of the literature was performed to identify relevant studies. Statistical analysis was carried out using Review Manager software 5.3. Results Eleven studies involving 1672 patients (1005 in Braun group and 667 in non-Braun group) were included in the meta-analysis. Braun enteroenterostomy was associated with a statistically significant reduction in overall DGE (odds ratios [OR] 0.32, 95% confidence intervals [CI] 0.24 to 0.43; P <0.001), clinically significant DGE (OR 0.27, 95% CI 0.15 to 0.51; P <0.001), bile leak (OR 0.50, 95% CI 0.29 to 0.86; P = 0.01), and length of hospital stay (weighted mean difference -1.66, 95% CI -2.95 to 00.37; P = 0.01). Conclusions Braun enteroenterostomy minimizes the rate and severity of DGE following pancreaticoduodenectomy. Delayed gastric emptying (dpeaa)DE-He213 Braun enteroenterostomy (dpeaa)DE-He213 Pancreatoduodenectomy (dpeaa)DE-He213 Meta-analysis (dpeaa)DE-He213 Hu, Bin aut Wei, Kongyuan aut Si, Xiaoying aut Enthalten in BMC gastroenterology London : BioMed Central, 2001 18(2018), 1 vom: 26. Nov. (DE-627)326643702 (DE-600)2041351-8 1471-230X nnns volume:18 year:2018 number:1 day:26 month:11 https://dx.doi.org/10.1186/s12876-018-0909-5 kostenfrei Volltext GBV_USEFLAG_A SYSFLAG_A GBV_SPRINGER SSG-OLC-PHA GBV_ILN_20 GBV_ILN_22 GBV_ILN_23 GBV_ILN_24 GBV_ILN_39 GBV_ILN_40 GBV_ILN_60 GBV_ILN_62 GBV_ILN_63 GBV_ILN_65 GBV_ILN_69 GBV_ILN_73 GBV_ILN_74 GBV_ILN_95 GBV_ILN_105 GBV_ILN_110 GBV_ILN_151 GBV_ILN_161 GBV_ILN_170 GBV_ILN_206 GBV_ILN_213 GBV_ILN_230 GBV_ILN_285 GBV_ILN_293 GBV_ILN_602 GBV_ILN_702 GBV_ILN_2001 GBV_ILN_2003 GBV_ILN_2005 GBV_ILN_2006 GBV_ILN_2008 GBV_ILN_2009 GBV_ILN_2010 GBV_ILN_2011 GBV_ILN_2014 GBV_ILN_2015 GBV_ILN_2020 GBV_ILN_2021 GBV_ILN_2025 GBV_ILN_2031 GBV_ILN_2038 GBV_ILN_2044 GBV_ILN_2048 GBV_ILN_2050 GBV_ILN_2055 GBV_ILN_2056 GBV_ILN_2057 GBV_ILN_2061 GBV_ILN_2111 GBV_ILN_2113 GBV_ILN_2190 GBV_ILN_4012 GBV_ILN_4037 GBV_ILN_4112 GBV_ILN_4125 GBV_ILN_4126 GBV_ILN_4249 GBV_ILN_4305 GBV_ILN_4306 GBV_ILN_4307 GBV_ILN_4313 GBV_ILN_4322 GBV_ILN_4323 GBV_ILN_4324 GBV_ILN_4325 GBV_ILN_4338 GBV_ILN_4367 GBV_ILN_4700 AR 18 2018 1 26 11 |
language |
English |
source |
Enthalten in BMC gastroenterology 18(2018), 1 vom: 26. Nov. volume:18 year:2018 number:1 day:26 month:11 |
sourceStr |
Enthalten in BMC gastroenterology 18(2018), 1 vom: 26. Nov. volume:18 year:2018 number:1 day:26 month:11 |
format_phy_str_mv |
Article |
institution |
findex.gbv.de |
topic_facet |
Delayed gastric emptying Braun enteroenterostomy Pancreatoduodenectomy Meta-analysis |
isfreeaccess_bool |
true |
container_title |
BMC gastroenterology |
authorswithroles_txt_mv |
Zhou, Yanming @@aut@@ Hu, Bin @@aut@@ Wei, Kongyuan @@aut@@ Si, Xiaoying @@aut@@ |
publishDateDaySort_date |
2018-11-26T00:00:00Z |
hierarchy_top_id |
326643702 |
id |
SPR027423247 |
language_de |
englisch |
fullrecord |
<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim"><record><leader>01000caa a22002652 4500</leader><controlfield tag="001">SPR027423247</controlfield><controlfield tag="003">DE-627</controlfield><controlfield tag="005">20230519101607.0</controlfield><controlfield tag="007">cr uuu---uuuuu</controlfield><controlfield tag="008">201007s2018 xx |||||o 00| ||eng c</controlfield><datafield tag="024" ind1="7" ind2=" "><subfield code="a">10.1186/s12876-018-0909-5</subfield><subfield code="2">doi</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-627)SPR027423247</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(SPR)s12876-018-0909-5-e</subfield></datafield><datafield tag="040" ind1=" " ind2=" "><subfield code="a">DE-627</subfield><subfield code="b">ger</subfield><subfield code="c">DE-627</subfield><subfield code="e">rakwb</subfield></datafield><datafield tag="041" ind1=" " ind2=" "><subfield code="a">eng</subfield></datafield><datafield tag="100" ind1="1" ind2=" "><subfield code="a">Zhou, Yanming</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="245" ind1="1" ind2="0"><subfield code="a">Braun anastomosis lowers the incidence of delayed gastric emptying following pancreaticoduodenectomy: a meta-analysis</subfield></datafield><datafield tag="264" ind1=" " ind2="1"><subfield code="c">2018</subfield></datafield><datafield tag="336" ind1=" " ind2=" "><subfield code="a">Text</subfield><subfield code="b">txt</subfield><subfield code="2">rdacontent</subfield></datafield><datafield tag="337" ind1=" " ind2=" "><subfield code="a">Computermedien</subfield><subfield code="b">c</subfield><subfield code="2">rdamedia</subfield></datafield><datafield tag="338" ind1=" " ind2=" "><subfield code="a">Online-Ressource</subfield><subfield code="b">cr</subfield><subfield code="2">rdacarrier</subfield></datafield><datafield tag="500" ind1=" " ind2=" "><subfield code="a">© The Author(s). 2018</subfield></datafield><datafield tag="520" ind1=" " ind2=" "><subfield code="a">Background Delayed gastric emptying (DGE) is one of the most frequent complications following pancreaticoduodenectomy. This meta-analysis aimed to evaluate the impact of Braun enteroenterostomy on DGE following pancreaticoduodenectomy. Methods A systematic review of the literature was performed to identify relevant studies. Statistical analysis was carried out using Review Manager software 5.3. Results Eleven studies involving 1672 patients (1005 in Braun group and 667 in non-Braun group) were included in the meta-analysis. Braun enteroenterostomy was associated with a statistically significant reduction in overall DGE (odds ratios [OR] 0.32, 95% confidence intervals [CI] 0.24 to 0.43; P <0.001), clinically significant DGE (OR 0.27, 95% CI 0.15 to 0.51; P <0.001), bile leak (OR 0.50, 95% CI 0.29 to 0.86; P = 0.01), and length of hospital stay (weighted mean difference -1.66, 95% CI -2.95 to 00.37; P = 0.01). Conclusions Braun enteroenterostomy minimizes the rate and severity of DGE following pancreaticoduodenectomy.</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Delayed gastric emptying</subfield><subfield code="7">(dpeaa)DE-He213</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Braun enteroenterostomy</subfield><subfield code="7">(dpeaa)DE-He213</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Pancreatoduodenectomy</subfield><subfield code="7">(dpeaa)DE-He213</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Meta-analysis</subfield><subfield code="7">(dpeaa)DE-He213</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Hu, Bin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Wei, Kongyuan</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Si, Xiaoying</subfield><subfield code="4">aut</subfield></datafield><datafield tag="773" ind1="0" ind2="8"><subfield code="i">Enthalten in</subfield><subfield code="t">BMC gastroenterology</subfield><subfield code="d">London : BioMed Central, 2001</subfield><subfield code="g">18(2018), 1 vom: 26. Nov.</subfield><subfield code="w">(DE-627)326643702</subfield><subfield code="w">(DE-600)2041351-8</subfield><subfield code="x">1471-230X</subfield><subfield code="7">nnns</subfield></datafield><datafield tag="773" ind1="1" ind2="8"><subfield code="g">volume:18</subfield><subfield code="g">year:2018</subfield><subfield code="g">number:1</subfield><subfield code="g">day:26</subfield><subfield code="g">month:11</subfield></datafield><datafield tag="856" ind1="4" ind2="0"><subfield code="u">https://dx.doi.org/10.1186/s12876-018-0909-5</subfield><subfield code="z">kostenfrei</subfield><subfield code="3">Volltext</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_USEFLAG_A</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">SYSFLAG_A</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_SPRINGER</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">SSG-OLC-PHA</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_20</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_22</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_23</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_24</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_39</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_40</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_60</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_62</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_63</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_65</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_69</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_73</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_74</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_95</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_105</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_110</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_151</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_161</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_170</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_206</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_213</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_230</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_285</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_293</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_602</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_702</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2001</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2003</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2005</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2006</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2008</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2009</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2010</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2011</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2014</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2015</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2020</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2021</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2025</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2031</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2038</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2044</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2048</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2050</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2055</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2056</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2057</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2061</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2111</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2113</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2190</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4012</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4037</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4112</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4125</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4126</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4249</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4305</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4306</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4307</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4313</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4322</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4323</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4324</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4325</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4338</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4367</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4700</subfield></datafield><datafield tag="951" ind1=" " ind2=" "><subfield code="a">AR</subfield></datafield><datafield tag="952" ind1=" " ind2=" "><subfield code="d">18</subfield><subfield code="j">2018</subfield><subfield code="e">1</subfield><subfield code="b">26</subfield><subfield code="c">11</subfield></datafield></record></collection>
|
author |
Zhou, Yanming |
spellingShingle |
Zhou, Yanming misc Delayed gastric emptying misc Braun enteroenterostomy misc Pancreatoduodenectomy misc Meta-analysis Braun anastomosis lowers the incidence of delayed gastric emptying following pancreaticoduodenectomy: a meta-analysis |
authorStr |
Zhou, Yanming |
ppnlink_with_tag_str_mv |
@@773@@(DE-627)326643702 |
format |
electronic Article |
delete_txt_mv |
keep |
author_role |
aut aut aut aut |
collection |
springer |
remote_str |
true |
illustrated |
Not Illustrated |
issn |
1471-230X |
topic_title |
Braun anastomosis lowers the incidence of delayed gastric emptying following pancreaticoduodenectomy: a meta-analysis Delayed gastric emptying (dpeaa)DE-He213 Braun enteroenterostomy (dpeaa)DE-He213 Pancreatoduodenectomy (dpeaa)DE-He213 Meta-analysis (dpeaa)DE-He213 |
topic |
misc Delayed gastric emptying misc Braun enteroenterostomy misc Pancreatoduodenectomy misc Meta-analysis |
topic_unstemmed |
misc Delayed gastric emptying misc Braun enteroenterostomy misc Pancreatoduodenectomy misc Meta-analysis |
topic_browse |
misc Delayed gastric emptying misc Braun enteroenterostomy misc Pancreatoduodenectomy misc Meta-analysis |
format_facet |
Elektronische Aufsätze Aufsätze Elektronische Ressource |
format_main_str_mv |
Text Zeitschrift/Artikel |
carriertype_str_mv |
cr |
hierarchy_parent_title |
BMC gastroenterology |
hierarchy_parent_id |
326643702 |
hierarchy_top_title |
BMC gastroenterology |
isfreeaccess_txt |
true |
familylinks_str_mv |
(DE-627)326643702 (DE-600)2041351-8 |
title |
Braun anastomosis lowers the incidence of delayed gastric emptying following pancreaticoduodenectomy: a meta-analysis |
ctrlnum |
(DE-627)SPR027423247 (SPR)s12876-018-0909-5-e |
title_full |
Braun anastomosis lowers the incidence of delayed gastric emptying following pancreaticoduodenectomy: a meta-analysis |
author_sort |
Zhou, Yanming |
journal |
BMC gastroenterology |
journalStr |
BMC gastroenterology |
lang_code |
eng |
isOA_bool |
true |
recordtype |
marc |
publishDateSort |
2018 |
contenttype_str_mv |
txt |
author_browse |
Zhou, Yanming Hu, Bin Wei, Kongyuan Si, Xiaoying |
container_volume |
18 |
format_se |
Elektronische Aufsätze |
author-letter |
Zhou, Yanming |
doi_str_mv |
10.1186/s12876-018-0909-5 |
title_sort |
braun anastomosis lowers the incidence of delayed gastric emptying following pancreaticoduodenectomy: a meta-analysis |
title_auth |
Braun anastomosis lowers the incidence of delayed gastric emptying following pancreaticoduodenectomy: a meta-analysis |
abstract |
Background Delayed gastric emptying (DGE) is one of the most frequent complications following pancreaticoduodenectomy. This meta-analysis aimed to evaluate the impact of Braun enteroenterostomy on DGE following pancreaticoduodenectomy. Methods A systematic review of the literature was performed to identify relevant studies. Statistical analysis was carried out using Review Manager software 5.3. Results Eleven studies involving 1672 patients (1005 in Braun group and 667 in non-Braun group) were included in the meta-analysis. Braun enteroenterostomy was associated with a statistically significant reduction in overall DGE (odds ratios [OR] 0.32, 95% confidence intervals [CI] 0.24 to 0.43; P <0.001), clinically significant DGE (OR 0.27, 95% CI 0.15 to 0.51; P <0.001), bile leak (OR 0.50, 95% CI 0.29 to 0.86; P = 0.01), and length of hospital stay (weighted mean difference -1.66, 95% CI -2.95 to 00.37; P = 0.01). Conclusions Braun enteroenterostomy minimizes the rate and severity of DGE following pancreaticoduodenectomy. © The Author(s). 2018 |
abstractGer |
Background Delayed gastric emptying (DGE) is one of the most frequent complications following pancreaticoduodenectomy. This meta-analysis aimed to evaluate the impact of Braun enteroenterostomy on DGE following pancreaticoduodenectomy. Methods A systematic review of the literature was performed to identify relevant studies. Statistical analysis was carried out using Review Manager software 5.3. Results Eleven studies involving 1672 patients (1005 in Braun group and 667 in non-Braun group) were included in the meta-analysis. Braun enteroenterostomy was associated with a statistically significant reduction in overall DGE (odds ratios [OR] 0.32, 95% confidence intervals [CI] 0.24 to 0.43; P <0.001), clinically significant DGE (OR 0.27, 95% CI 0.15 to 0.51; P <0.001), bile leak (OR 0.50, 95% CI 0.29 to 0.86; P = 0.01), and length of hospital stay (weighted mean difference -1.66, 95% CI -2.95 to 00.37; P = 0.01). Conclusions Braun enteroenterostomy minimizes the rate and severity of DGE following pancreaticoduodenectomy. © The Author(s). 2018 |
abstract_unstemmed |
Background Delayed gastric emptying (DGE) is one of the most frequent complications following pancreaticoduodenectomy. This meta-analysis aimed to evaluate the impact of Braun enteroenterostomy on DGE following pancreaticoduodenectomy. Methods A systematic review of the literature was performed to identify relevant studies. Statistical analysis was carried out using Review Manager software 5.3. Results Eleven studies involving 1672 patients (1005 in Braun group and 667 in non-Braun group) were included in the meta-analysis. Braun enteroenterostomy was associated with a statistically significant reduction in overall DGE (odds ratios [OR] 0.32, 95% confidence intervals [CI] 0.24 to 0.43; P <0.001), clinically significant DGE (OR 0.27, 95% CI 0.15 to 0.51; P <0.001), bile leak (OR 0.50, 95% CI 0.29 to 0.86; P = 0.01), and length of hospital stay (weighted mean difference -1.66, 95% CI -2.95 to 00.37; P = 0.01). Conclusions Braun enteroenterostomy minimizes the rate and severity of DGE following pancreaticoduodenectomy. © The Author(s). 2018 |
collection_details |
GBV_USEFLAG_A SYSFLAG_A GBV_SPRINGER SSG-OLC-PHA GBV_ILN_20 GBV_ILN_22 GBV_ILN_23 GBV_ILN_24 GBV_ILN_39 GBV_ILN_40 GBV_ILN_60 GBV_ILN_62 GBV_ILN_63 GBV_ILN_65 GBV_ILN_69 GBV_ILN_73 GBV_ILN_74 GBV_ILN_95 GBV_ILN_105 GBV_ILN_110 GBV_ILN_151 GBV_ILN_161 GBV_ILN_170 GBV_ILN_206 GBV_ILN_213 GBV_ILN_230 GBV_ILN_285 GBV_ILN_293 GBV_ILN_602 GBV_ILN_702 GBV_ILN_2001 GBV_ILN_2003 GBV_ILN_2005 GBV_ILN_2006 GBV_ILN_2008 GBV_ILN_2009 GBV_ILN_2010 GBV_ILN_2011 GBV_ILN_2014 GBV_ILN_2015 GBV_ILN_2020 GBV_ILN_2021 GBV_ILN_2025 GBV_ILN_2031 GBV_ILN_2038 GBV_ILN_2044 GBV_ILN_2048 GBV_ILN_2050 GBV_ILN_2055 GBV_ILN_2056 GBV_ILN_2057 GBV_ILN_2061 GBV_ILN_2111 GBV_ILN_2113 GBV_ILN_2190 GBV_ILN_4012 GBV_ILN_4037 GBV_ILN_4112 GBV_ILN_4125 GBV_ILN_4126 GBV_ILN_4249 GBV_ILN_4305 GBV_ILN_4306 GBV_ILN_4307 GBV_ILN_4313 GBV_ILN_4322 GBV_ILN_4323 GBV_ILN_4324 GBV_ILN_4325 GBV_ILN_4338 GBV_ILN_4367 GBV_ILN_4700 |
container_issue |
1 |
title_short |
Braun anastomosis lowers the incidence of delayed gastric emptying following pancreaticoduodenectomy: a meta-analysis |
url |
https://dx.doi.org/10.1186/s12876-018-0909-5 |
remote_bool |
true |
author2 |
Hu, Bin Wei, Kongyuan Si, Xiaoying |
author2Str |
Hu, Bin Wei, Kongyuan Si, Xiaoying |
ppnlink |
326643702 |
mediatype_str_mv |
c |
isOA_txt |
true |
hochschulschrift_bool |
false |
doi_str |
10.1186/s12876-018-0909-5 |
up_date |
2024-07-04T01:48:33.114Z |
_version_ |
1803611236588322816 |
fullrecord_marcxml |
<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim"><record><leader>01000caa a22002652 4500</leader><controlfield tag="001">SPR027423247</controlfield><controlfield tag="003">DE-627</controlfield><controlfield tag="005">20230519101607.0</controlfield><controlfield tag="007">cr uuu---uuuuu</controlfield><controlfield tag="008">201007s2018 xx |||||o 00| ||eng c</controlfield><datafield tag="024" ind1="7" ind2=" "><subfield code="a">10.1186/s12876-018-0909-5</subfield><subfield code="2">doi</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-627)SPR027423247</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(SPR)s12876-018-0909-5-e</subfield></datafield><datafield tag="040" ind1=" " ind2=" "><subfield code="a">DE-627</subfield><subfield code="b">ger</subfield><subfield code="c">DE-627</subfield><subfield code="e">rakwb</subfield></datafield><datafield tag="041" ind1=" " ind2=" "><subfield code="a">eng</subfield></datafield><datafield tag="100" ind1="1" ind2=" "><subfield code="a">Zhou, Yanming</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="245" ind1="1" ind2="0"><subfield code="a">Braun anastomosis lowers the incidence of delayed gastric emptying following pancreaticoduodenectomy: a meta-analysis</subfield></datafield><datafield tag="264" ind1=" " ind2="1"><subfield code="c">2018</subfield></datafield><datafield tag="336" ind1=" " ind2=" "><subfield code="a">Text</subfield><subfield code="b">txt</subfield><subfield code="2">rdacontent</subfield></datafield><datafield tag="337" ind1=" " ind2=" "><subfield code="a">Computermedien</subfield><subfield code="b">c</subfield><subfield code="2">rdamedia</subfield></datafield><datafield tag="338" ind1=" " ind2=" "><subfield code="a">Online-Ressource</subfield><subfield code="b">cr</subfield><subfield code="2">rdacarrier</subfield></datafield><datafield tag="500" ind1=" " ind2=" "><subfield code="a">© The Author(s). 2018</subfield></datafield><datafield tag="520" ind1=" " ind2=" "><subfield code="a">Background Delayed gastric emptying (DGE) is one of the most frequent complications following pancreaticoduodenectomy. This meta-analysis aimed to evaluate the impact of Braun enteroenterostomy on DGE following pancreaticoduodenectomy. Methods A systematic review of the literature was performed to identify relevant studies. Statistical analysis was carried out using Review Manager software 5.3. Results Eleven studies involving 1672 patients (1005 in Braun group and 667 in non-Braun group) were included in the meta-analysis. Braun enteroenterostomy was associated with a statistically significant reduction in overall DGE (odds ratios [OR] 0.32, 95% confidence intervals [CI] 0.24 to 0.43; P <0.001), clinically significant DGE (OR 0.27, 95% CI 0.15 to 0.51; P <0.001), bile leak (OR 0.50, 95% CI 0.29 to 0.86; P = 0.01), and length of hospital stay (weighted mean difference -1.66, 95% CI -2.95 to 00.37; P = 0.01). Conclusions Braun enteroenterostomy minimizes the rate and severity of DGE following pancreaticoduodenectomy.</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Delayed gastric emptying</subfield><subfield code="7">(dpeaa)DE-He213</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Braun enteroenterostomy</subfield><subfield code="7">(dpeaa)DE-He213</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Pancreatoduodenectomy</subfield><subfield code="7">(dpeaa)DE-He213</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Meta-analysis</subfield><subfield code="7">(dpeaa)DE-He213</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Hu, Bin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Wei, Kongyuan</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Si, Xiaoying</subfield><subfield code="4">aut</subfield></datafield><datafield tag="773" ind1="0" ind2="8"><subfield code="i">Enthalten in</subfield><subfield code="t">BMC gastroenterology</subfield><subfield code="d">London : BioMed Central, 2001</subfield><subfield code="g">18(2018), 1 vom: 26. Nov.</subfield><subfield code="w">(DE-627)326643702</subfield><subfield code="w">(DE-600)2041351-8</subfield><subfield code="x">1471-230X</subfield><subfield code="7">nnns</subfield></datafield><datafield tag="773" ind1="1" ind2="8"><subfield code="g">volume:18</subfield><subfield code="g">year:2018</subfield><subfield code="g">number:1</subfield><subfield code="g">day:26</subfield><subfield code="g">month:11</subfield></datafield><datafield tag="856" ind1="4" ind2="0"><subfield code="u">https://dx.doi.org/10.1186/s12876-018-0909-5</subfield><subfield code="z">kostenfrei</subfield><subfield code="3">Volltext</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_USEFLAG_A</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">SYSFLAG_A</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_SPRINGER</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">SSG-OLC-PHA</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_20</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_22</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_23</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_24</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_39</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_40</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_60</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_62</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_63</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_65</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_69</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_73</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_74</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_95</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_105</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_110</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_151</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_161</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_170</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_206</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_213</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_230</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_285</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_293</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_602</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_702</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2001</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2003</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2005</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2006</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2008</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2009</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2010</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2011</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2014</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2015</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2020</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2021</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2025</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2031</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2038</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2044</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2048</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2050</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2055</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2056</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2057</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2061</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2111</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2113</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2190</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4012</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4037</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4112</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4125</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4126</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4249</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4305</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4306</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4307</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4313</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4322</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4323</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4324</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4325</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4338</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4367</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4700</subfield></datafield><datafield tag="951" ind1=" " ind2=" "><subfield code="a">AR</subfield></datafield><datafield tag="952" ind1=" " ind2=" "><subfield code="d">18</subfield><subfield code="j">2018</subfield><subfield code="e">1</subfield><subfield code="b">26</subfield><subfield code="c">11</subfield></datafield></record></collection>
|
score |
7.4001923 |