The effect of initial teaching on evaluation of left ventricular volumes by cardiovascular magnetic resonance imaging: comparison between complete and intermediate beginners and experienced observers
Background High reproducibility and low intra- and interobserver variability are important strengths of cardiac magnetic resonance (CMR). In clinical practice a significant learning curve may however be observed. Basic CMR courses offer an average of 1.4 h dedicated to lecturing and demonstrating le...
Ausführliche Beschreibung
Autor*in: |
Hedström, Erik [verfasserIn] |
---|
Format: |
E-Artikel |
---|---|
Sprache: |
Englisch |
Erschienen: |
2017 |
---|
Schlagwörter: |
---|
Anmerkung: |
© The Author(s). 2017 |
---|
Übergeordnetes Werk: |
Enthalten in: BMC medical imaging - London : BioMed Central, 2001, 17(2017), 1 vom: 17. Mai |
---|---|
Übergeordnetes Werk: |
volume:17 ; year:2017 ; number:1 ; day:17 ; month:05 |
Links: |
---|
DOI / URN: |
10.1186/s12880-017-0197-5 |
---|
Katalog-ID: |
SPR027477096 |
---|
LEADER | 01000caa a22002652 4500 | ||
---|---|---|---|
001 | SPR027477096 | ||
003 | DE-627 | ||
005 | 20230520001109.0 | ||
007 | cr uuu---uuuuu | ||
008 | 201007s2017 xx |||||o 00| ||eng c | ||
024 | 7 | |a 10.1186/s12880-017-0197-5 |2 doi | |
035 | |a (DE-627)SPR027477096 | ||
035 | |a (SPR)s12880-017-0197-5-e | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
100 | 1 | |a Hedström, Erik |e verfasserin |0 (orcid)0000-0003-0041-9357 |4 aut | |
245 | 1 | 4 | |a The effect of initial teaching on evaluation of left ventricular volumes by cardiovascular magnetic resonance imaging: comparison between complete and intermediate beginners and experienced observers |
264 | 1 | |c 2017 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a Computermedien |b c |2 rdamedia | ||
338 | |a Online-Ressource |b cr |2 rdacarrier | ||
500 | |a © The Author(s). 2017 | ||
520 | |a Background High reproducibility and low intra- and interobserver variability are important strengths of cardiac magnetic resonance (CMR). In clinical practice a significant learning curve may however be observed. Basic CMR courses offer an average of 1.4 h dedicated to lecturing and demonstrating left ventricular (LV) function analysis. The purpose of this study was to evaluate the effect of initial teaching on complete and intermediate beginners’ quantitative measurements of LV volumes and function by CMR. Methods Standard clinical cine CMR sequences were acquired in 15 patients. Five observers (two complete beginners, one intermediate, two experienced) measured LV volumes. Before initial evaluation beginners read the SCMR guidelines on CMR analysis. After initial evaluation, beginners participated in a two-hour teaching session including cases and hands-on training, representative for most basic CMR courses, after which it is uncertain to what extent different centres provide continued teaching and feedback in-house. Dice Similarity Coefficient (DSC) assessed delineations. Agreement, accuracy, precision, repeatability and reliability were assessed by Bland-Altman, coefficient of variation, and intraclass correlation coefficient methods. Results Endocardial DSC improved after teaching (+0.14 ± 0.17;p < 0.001) for complete beginners. Low intraobserver variability was found before and after teaching, however with wide limits of agreement. Beginners underestimated volumes by up to 44 ml (EDV), 27 ml (ESV) and overestimated LVM by up to 53 g before teaching, improving to an underestimation of up to 9 ml (EDV), 7 ml (ESV) and an overestimation of up to 30 g (LVM) after teaching. For the intermediate beginner, however, accuracy was quite high already before teaching. Conclusions Initial teaching to complete beginners increases accuracy for assessment of LV volumes, however with high bias and low precision even after standardised teaching as offered in most basic CMR courses. Even though the intermediate beginner showed quite high accuracy already before teaching, precision did generally not improve after standardised teaching. To maintain CMR as a technique known for high accuracy and reproducibility and low intra- and inter-observer variability for quantitative measurements, internationally standardised training should be encouraged including high-quality feedback mechanisms. Objective measurements of training methods, training duration and, above all, quality of assessments are required. | ||
650 | 4 | |a CMR |7 (dpeaa)DE-He213 | |
650 | 4 | |a Teaching |7 (dpeaa)DE-He213 | |
650 | 4 | |a Cine |7 (dpeaa)DE-He213 | |
650 | 4 | |a Function |7 (dpeaa)DE-He213 | |
650 | 4 | |a Beginners |7 (dpeaa)DE-He213 | |
700 | 1 | |a Ishida, Masaki |4 aut | |
700 | 1 | |a Sepúlveda-Martínez, Alvaro |4 aut | |
700 | 1 | |a Ryd, Daniel |4 aut | |
700 | 1 | |a Sperling, Johannes |4 aut | |
700 | 1 | |a Engblom, Henrik |4 aut | |
700 | 1 | |a Nagel, Eike |4 aut | |
773 | 0 | 8 | |i Enthalten in |t BMC medical imaging |d London : BioMed Central, 2001 |g 17(2017), 1 vom: 17. Mai |w (DE-627)33679911X |w (DE-600)2061975-3 |x 1471-2342 |7 nnns |
773 | 1 | 8 | |g volume:17 |g year:2017 |g number:1 |g day:17 |g month:05 |
856 | 4 | 0 | |u https://dx.doi.org/10.1186/s12880-017-0197-5 |z kostenfrei |3 Volltext |
912 | |a GBV_USEFLAG_A | ||
912 | |a SYSFLAG_A | ||
912 | |a GBV_SPRINGER | ||
912 | |a SSG-OLC-PHA | ||
912 | |a GBV_ILN_11 | ||
912 | |a GBV_ILN_20 | ||
912 | |a GBV_ILN_22 | ||
912 | |a GBV_ILN_23 | ||
912 | |a GBV_ILN_24 | ||
912 | |a GBV_ILN_39 | ||
912 | |a GBV_ILN_40 | ||
912 | |a GBV_ILN_60 | ||
912 | |a GBV_ILN_62 | ||
912 | |a GBV_ILN_63 | ||
912 | |a GBV_ILN_65 | ||
912 | |a GBV_ILN_69 | ||
912 | |a GBV_ILN_73 | ||
912 | |a GBV_ILN_74 | ||
912 | |a GBV_ILN_95 | ||
912 | |a GBV_ILN_105 | ||
912 | |a GBV_ILN_110 | ||
912 | |a GBV_ILN_151 | ||
912 | |a GBV_ILN_161 | ||
912 | |a GBV_ILN_170 | ||
912 | |a GBV_ILN_206 | ||
912 | |a GBV_ILN_213 | ||
912 | |a GBV_ILN_230 | ||
912 | |a GBV_ILN_285 | ||
912 | |a GBV_ILN_293 | ||
912 | |a GBV_ILN_602 | ||
912 | |a GBV_ILN_2003 | ||
912 | |a GBV_ILN_2014 | ||
912 | |a GBV_ILN_4012 | ||
912 | |a GBV_ILN_4037 | ||
912 | |a GBV_ILN_4112 | ||
912 | |a GBV_ILN_4125 | ||
912 | |a GBV_ILN_4126 | ||
912 | |a GBV_ILN_4249 | ||
912 | |a GBV_ILN_4305 | ||
912 | |a GBV_ILN_4306 | ||
912 | |a GBV_ILN_4307 | ||
912 | |a GBV_ILN_4313 | ||
912 | |a GBV_ILN_4322 | ||
912 | |a GBV_ILN_4323 | ||
912 | |a GBV_ILN_4324 | ||
912 | |a GBV_ILN_4325 | ||
912 | |a GBV_ILN_4338 | ||
912 | |a GBV_ILN_4367 | ||
912 | |a GBV_ILN_4700 | ||
951 | |a AR | ||
952 | |d 17 |j 2017 |e 1 |b 17 |c 05 |
author_variant |
e h eh m i mi a s m asm d r dr j s js h e he e n en |
---|---|
matchkey_str |
article:14712342:2017----::hefcoiiilecignvlainfetetiuavlmsyadoaclrantceoaciaigoprsnewecmlta |
hierarchy_sort_str |
2017 |
publishDate |
2017 |
allfields |
10.1186/s12880-017-0197-5 doi (DE-627)SPR027477096 (SPR)s12880-017-0197-5-e DE-627 ger DE-627 rakwb eng Hedström, Erik verfasserin (orcid)0000-0003-0041-9357 aut The effect of initial teaching on evaluation of left ventricular volumes by cardiovascular magnetic resonance imaging: comparison between complete and intermediate beginners and experienced observers 2017 Text txt rdacontent Computermedien c rdamedia Online-Ressource cr rdacarrier © The Author(s). 2017 Background High reproducibility and low intra- and interobserver variability are important strengths of cardiac magnetic resonance (CMR). In clinical practice a significant learning curve may however be observed. Basic CMR courses offer an average of 1.4 h dedicated to lecturing and demonstrating left ventricular (LV) function analysis. The purpose of this study was to evaluate the effect of initial teaching on complete and intermediate beginners’ quantitative measurements of LV volumes and function by CMR. Methods Standard clinical cine CMR sequences were acquired in 15 patients. Five observers (two complete beginners, one intermediate, two experienced) measured LV volumes. Before initial evaluation beginners read the SCMR guidelines on CMR analysis. After initial evaluation, beginners participated in a two-hour teaching session including cases and hands-on training, representative for most basic CMR courses, after which it is uncertain to what extent different centres provide continued teaching and feedback in-house. Dice Similarity Coefficient (DSC) assessed delineations. Agreement, accuracy, precision, repeatability and reliability were assessed by Bland-Altman, coefficient of variation, and intraclass correlation coefficient methods. Results Endocardial DSC improved after teaching (+0.14 ± 0.17;p < 0.001) for complete beginners. Low intraobserver variability was found before and after teaching, however with wide limits of agreement. Beginners underestimated volumes by up to 44 ml (EDV), 27 ml (ESV) and overestimated LVM by up to 53 g before teaching, improving to an underestimation of up to 9 ml (EDV), 7 ml (ESV) and an overestimation of up to 30 g (LVM) after teaching. For the intermediate beginner, however, accuracy was quite high already before teaching. Conclusions Initial teaching to complete beginners increases accuracy for assessment of LV volumes, however with high bias and low precision even after standardised teaching as offered in most basic CMR courses. Even though the intermediate beginner showed quite high accuracy already before teaching, precision did generally not improve after standardised teaching. To maintain CMR as a technique known for high accuracy and reproducibility and low intra- and inter-observer variability for quantitative measurements, internationally standardised training should be encouraged including high-quality feedback mechanisms. Objective measurements of training methods, training duration and, above all, quality of assessments are required. CMR (dpeaa)DE-He213 Teaching (dpeaa)DE-He213 Cine (dpeaa)DE-He213 Function (dpeaa)DE-He213 Beginners (dpeaa)DE-He213 Ishida, Masaki aut Sepúlveda-Martínez, Alvaro aut Ryd, Daniel aut Sperling, Johannes aut Engblom, Henrik aut Nagel, Eike aut Enthalten in BMC medical imaging London : BioMed Central, 2001 17(2017), 1 vom: 17. Mai (DE-627)33679911X (DE-600)2061975-3 1471-2342 nnns volume:17 year:2017 number:1 day:17 month:05 https://dx.doi.org/10.1186/s12880-017-0197-5 kostenfrei Volltext GBV_USEFLAG_A SYSFLAG_A GBV_SPRINGER SSG-OLC-PHA GBV_ILN_11 GBV_ILN_20 GBV_ILN_22 GBV_ILN_23 GBV_ILN_24 GBV_ILN_39 GBV_ILN_40 GBV_ILN_60 GBV_ILN_62 GBV_ILN_63 GBV_ILN_65 GBV_ILN_69 GBV_ILN_73 GBV_ILN_74 GBV_ILN_95 GBV_ILN_105 GBV_ILN_110 GBV_ILN_151 GBV_ILN_161 GBV_ILN_170 GBV_ILN_206 GBV_ILN_213 GBV_ILN_230 GBV_ILN_285 GBV_ILN_293 GBV_ILN_602 GBV_ILN_2003 GBV_ILN_2014 GBV_ILN_4012 GBV_ILN_4037 GBV_ILN_4112 GBV_ILN_4125 GBV_ILN_4126 GBV_ILN_4249 GBV_ILN_4305 GBV_ILN_4306 GBV_ILN_4307 GBV_ILN_4313 GBV_ILN_4322 GBV_ILN_4323 GBV_ILN_4324 GBV_ILN_4325 GBV_ILN_4338 GBV_ILN_4367 GBV_ILN_4700 AR 17 2017 1 17 05 |
spelling |
10.1186/s12880-017-0197-5 doi (DE-627)SPR027477096 (SPR)s12880-017-0197-5-e DE-627 ger DE-627 rakwb eng Hedström, Erik verfasserin (orcid)0000-0003-0041-9357 aut The effect of initial teaching on evaluation of left ventricular volumes by cardiovascular magnetic resonance imaging: comparison between complete and intermediate beginners and experienced observers 2017 Text txt rdacontent Computermedien c rdamedia Online-Ressource cr rdacarrier © The Author(s). 2017 Background High reproducibility and low intra- and interobserver variability are important strengths of cardiac magnetic resonance (CMR). In clinical practice a significant learning curve may however be observed. Basic CMR courses offer an average of 1.4 h dedicated to lecturing and demonstrating left ventricular (LV) function analysis. The purpose of this study was to evaluate the effect of initial teaching on complete and intermediate beginners’ quantitative measurements of LV volumes and function by CMR. Methods Standard clinical cine CMR sequences were acquired in 15 patients. Five observers (two complete beginners, one intermediate, two experienced) measured LV volumes. Before initial evaluation beginners read the SCMR guidelines on CMR analysis. After initial evaluation, beginners participated in a two-hour teaching session including cases and hands-on training, representative for most basic CMR courses, after which it is uncertain to what extent different centres provide continued teaching and feedback in-house. Dice Similarity Coefficient (DSC) assessed delineations. Agreement, accuracy, precision, repeatability and reliability were assessed by Bland-Altman, coefficient of variation, and intraclass correlation coefficient methods. Results Endocardial DSC improved after teaching (+0.14 ± 0.17;p < 0.001) for complete beginners. Low intraobserver variability was found before and after teaching, however with wide limits of agreement. Beginners underestimated volumes by up to 44 ml (EDV), 27 ml (ESV) and overestimated LVM by up to 53 g before teaching, improving to an underestimation of up to 9 ml (EDV), 7 ml (ESV) and an overestimation of up to 30 g (LVM) after teaching. For the intermediate beginner, however, accuracy was quite high already before teaching. Conclusions Initial teaching to complete beginners increases accuracy for assessment of LV volumes, however with high bias and low precision even after standardised teaching as offered in most basic CMR courses. Even though the intermediate beginner showed quite high accuracy already before teaching, precision did generally not improve after standardised teaching. To maintain CMR as a technique known for high accuracy and reproducibility and low intra- and inter-observer variability for quantitative measurements, internationally standardised training should be encouraged including high-quality feedback mechanisms. Objective measurements of training methods, training duration and, above all, quality of assessments are required. CMR (dpeaa)DE-He213 Teaching (dpeaa)DE-He213 Cine (dpeaa)DE-He213 Function (dpeaa)DE-He213 Beginners (dpeaa)DE-He213 Ishida, Masaki aut Sepúlveda-Martínez, Alvaro aut Ryd, Daniel aut Sperling, Johannes aut Engblom, Henrik aut Nagel, Eike aut Enthalten in BMC medical imaging London : BioMed Central, 2001 17(2017), 1 vom: 17. Mai (DE-627)33679911X (DE-600)2061975-3 1471-2342 nnns volume:17 year:2017 number:1 day:17 month:05 https://dx.doi.org/10.1186/s12880-017-0197-5 kostenfrei Volltext GBV_USEFLAG_A SYSFLAG_A GBV_SPRINGER SSG-OLC-PHA GBV_ILN_11 GBV_ILN_20 GBV_ILN_22 GBV_ILN_23 GBV_ILN_24 GBV_ILN_39 GBV_ILN_40 GBV_ILN_60 GBV_ILN_62 GBV_ILN_63 GBV_ILN_65 GBV_ILN_69 GBV_ILN_73 GBV_ILN_74 GBV_ILN_95 GBV_ILN_105 GBV_ILN_110 GBV_ILN_151 GBV_ILN_161 GBV_ILN_170 GBV_ILN_206 GBV_ILN_213 GBV_ILN_230 GBV_ILN_285 GBV_ILN_293 GBV_ILN_602 GBV_ILN_2003 GBV_ILN_2014 GBV_ILN_4012 GBV_ILN_4037 GBV_ILN_4112 GBV_ILN_4125 GBV_ILN_4126 GBV_ILN_4249 GBV_ILN_4305 GBV_ILN_4306 GBV_ILN_4307 GBV_ILN_4313 GBV_ILN_4322 GBV_ILN_4323 GBV_ILN_4324 GBV_ILN_4325 GBV_ILN_4338 GBV_ILN_4367 GBV_ILN_4700 AR 17 2017 1 17 05 |
allfields_unstemmed |
10.1186/s12880-017-0197-5 doi (DE-627)SPR027477096 (SPR)s12880-017-0197-5-e DE-627 ger DE-627 rakwb eng Hedström, Erik verfasserin (orcid)0000-0003-0041-9357 aut The effect of initial teaching on evaluation of left ventricular volumes by cardiovascular magnetic resonance imaging: comparison between complete and intermediate beginners and experienced observers 2017 Text txt rdacontent Computermedien c rdamedia Online-Ressource cr rdacarrier © The Author(s). 2017 Background High reproducibility and low intra- and interobserver variability are important strengths of cardiac magnetic resonance (CMR). In clinical practice a significant learning curve may however be observed. Basic CMR courses offer an average of 1.4 h dedicated to lecturing and demonstrating left ventricular (LV) function analysis. The purpose of this study was to evaluate the effect of initial teaching on complete and intermediate beginners’ quantitative measurements of LV volumes and function by CMR. Methods Standard clinical cine CMR sequences were acquired in 15 patients. Five observers (two complete beginners, one intermediate, two experienced) measured LV volumes. Before initial evaluation beginners read the SCMR guidelines on CMR analysis. After initial evaluation, beginners participated in a two-hour teaching session including cases and hands-on training, representative for most basic CMR courses, after which it is uncertain to what extent different centres provide continued teaching and feedback in-house. Dice Similarity Coefficient (DSC) assessed delineations. Agreement, accuracy, precision, repeatability and reliability were assessed by Bland-Altman, coefficient of variation, and intraclass correlation coefficient methods. Results Endocardial DSC improved after teaching (+0.14 ± 0.17;p < 0.001) for complete beginners. Low intraobserver variability was found before and after teaching, however with wide limits of agreement. Beginners underestimated volumes by up to 44 ml (EDV), 27 ml (ESV) and overestimated LVM by up to 53 g before teaching, improving to an underestimation of up to 9 ml (EDV), 7 ml (ESV) and an overestimation of up to 30 g (LVM) after teaching. For the intermediate beginner, however, accuracy was quite high already before teaching. Conclusions Initial teaching to complete beginners increases accuracy for assessment of LV volumes, however with high bias and low precision even after standardised teaching as offered in most basic CMR courses. Even though the intermediate beginner showed quite high accuracy already before teaching, precision did generally not improve after standardised teaching. To maintain CMR as a technique known for high accuracy and reproducibility and low intra- and inter-observer variability for quantitative measurements, internationally standardised training should be encouraged including high-quality feedback mechanisms. Objective measurements of training methods, training duration and, above all, quality of assessments are required. CMR (dpeaa)DE-He213 Teaching (dpeaa)DE-He213 Cine (dpeaa)DE-He213 Function (dpeaa)DE-He213 Beginners (dpeaa)DE-He213 Ishida, Masaki aut Sepúlveda-Martínez, Alvaro aut Ryd, Daniel aut Sperling, Johannes aut Engblom, Henrik aut Nagel, Eike aut Enthalten in BMC medical imaging London : BioMed Central, 2001 17(2017), 1 vom: 17. Mai (DE-627)33679911X (DE-600)2061975-3 1471-2342 nnns volume:17 year:2017 number:1 day:17 month:05 https://dx.doi.org/10.1186/s12880-017-0197-5 kostenfrei Volltext GBV_USEFLAG_A SYSFLAG_A GBV_SPRINGER SSG-OLC-PHA GBV_ILN_11 GBV_ILN_20 GBV_ILN_22 GBV_ILN_23 GBV_ILN_24 GBV_ILN_39 GBV_ILN_40 GBV_ILN_60 GBV_ILN_62 GBV_ILN_63 GBV_ILN_65 GBV_ILN_69 GBV_ILN_73 GBV_ILN_74 GBV_ILN_95 GBV_ILN_105 GBV_ILN_110 GBV_ILN_151 GBV_ILN_161 GBV_ILN_170 GBV_ILN_206 GBV_ILN_213 GBV_ILN_230 GBV_ILN_285 GBV_ILN_293 GBV_ILN_602 GBV_ILN_2003 GBV_ILN_2014 GBV_ILN_4012 GBV_ILN_4037 GBV_ILN_4112 GBV_ILN_4125 GBV_ILN_4126 GBV_ILN_4249 GBV_ILN_4305 GBV_ILN_4306 GBV_ILN_4307 GBV_ILN_4313 GBV_ILN_4322 GBV_ILN_4323 GBV_ILN_4324 GBV_ILN_4325 GBV_ILN_4338 GBV_ILN_4367 GBV_ILN_4700 AR 17 2017 1 17 05 |
allfieldsGer |
10.1186/s12880-017-0197-5 doi (DE-627)SPR027477096 (SPR)s12880-017-0197-5-e DE-627 ger DE-627 rakwb eng Hedström, Erik verfasserin (orcid)0000-0003-0041-9357 aut The effect of initial teaching on evaluation of left ventricular volumes by cardiovascular magnetic resonance imaging: comparison between complete and intermediate beginners and experienced observers 2017 Text txt rdacontent Computermedien c rdamedia Online-Ressource cr rdacarrier © The Author(s). 2017 Background High reproducibility and low intra- and interobserver variability are important strengths of cardiac magnetic resonance (CMR). In clinical practice a significant learning curve may however be observed. Basic CMR courses offer an average of 1.4 h dedicated to lecturing and demonstrating left ventricular (LV) function analysis. The purpose of this study was to evaluate the effect of initial teaching on complete and intermediate beginners’ quantitative measurements of LV volumes and function by CMR. Methods Standard clinical cine CMR sequences were acquired in 15 patients. Five observers (two complete beginners, one intermediate, two experienced) measured LV volumes. Before initial evaluation beginners read the SCMR guidelines on CMR analysis. After initial evaluation, beginners participated in a two-hour teaching session including cases and hands-on training, representative for most basic CMR courses, after which it is uncertain to what extent different centres provide continued teaching and feedback in-house. Dice Similarity Coefficient (DSC) assessed delineations. Agreement, accuracy, precision, repeatability and reliability were assessed by Bland-Altman, coefficient of variation, and intraclass correlation coefficient methods. Results Endocardial DSC improved after teaching (+0.14 ± 0.17;p < 0.001) for complete beginners. Low intraobserver variability was found before and after teaching, however with wide limits of agreement. Beginners underestimated volumes by up to 44 ml (EDV), 27 ml (ESV) and overestimated LVM by up to 53 g before teaching, improving to an underestimation of up to 9 ml (EDV), 7 ml (ESV) and an overestimation of up to 30 g (LVM) after teaching. For the intermediate beginner, however, accuracy was quite high already before teaching. Conclusions Initial teaching to complete beginners increases accuracy for assessment of LV volumes, however with high bias and low precision even after standardised teaching as offered in most basic CMR courses. Even though the intermediate beginner showed quite high accuracy already before teaching, precision did generally not improve after standardised teaching. To maintain CMR as a technique known for high accuracy and reproducibility and low intra- and inter-observer variability for quantitative measurements, internationally standardised training should be encouraged including high-quality feedback mechanisms. Objective measurements of training methods, training duration and, above all, quality of assessments are required. CMR (dpeaa)DE-He213 Teaching (dpeaa)DE-He213 Cine (dpeaa)DE-He213 Function (dpeaa)DE-He213 Beginners (dpeaa)DE-He213 Ishida, Masaki aut Sepúlveda-Martínez, Alvaro aut Ryd, Daniel aut Sperling, Johannes aut Engblom, Henrik aut Nagel, Eike aut Enthalten in BMC medical imaging London : BioMed Central, 2001 17(2017), 1 vom: 17. Mai (DE-627)33679911X (DE-600)2061975-3 1471-2342 nnns volume:17 year:2017 number:1 day:17 month:05 https://dx.doi.org/10.1186/s12880-017-0197-5 kostenfrei Volltext GBV_USEFLAG_A SYSFLAG_A GBV_SPRINGER SSG-OLC-PHA GBV_ILN_11 GBV_ILN_20 GBV_ILN_22 GBV_ILN_23 GBV_ILN_24 GBV_ILN_39 GBV_ILN_40 GBV_ILN_60 GBV_ILN_62 GBV_ILN_63 GBV_ILN_65 GBV_ILN_69 GBV_ILN_73 GBV_ILN_74 GBV_ILN_95 GBV_ILN_105 GBV_ILN_110 GBV_ILN_151 GBV_ILN_161 GBV_ILN_170 GBV_ILN_206 GBV_ILN_213 GBV_ILN_230 GBV_ILN_285 GBV_ILN_293 GBV_ILN_602 GBV_ILN_2003 GBV_ILN_2014 GBV_ILN_4012 GBV_ILN_4037 GBV_ILN_4112 GBV_ILN_4125 GBV_ILN_4126 GBV_ILN_4249 GBV_ILN_4305 GBV_ILN_4306 GBV_ILN_4307 GBV_ILN_4313 GBV_ILN_4322 GBV_ILN_4323 GBV_ILN_4324 GBV_ILN_4325 GBV_ILN_4338 GBV_ILN_4367 GBV_ILN_4700 AR 17 2017 1 17 05 |
allfieldsSound |
10.1186/s12880-017-0197-5 doi (DE-627)SPR027477096 (SPR)s12880-017-0197-5-e DE-627 ger DE-627 rakwb eng Hedström, Erik verfasserin (orcid)0000-0003-0041-9357 aut The effect of initial teaching on evaluation of left ventricular volumes by cardiovascular magnetic resonance imaging: comparison between complete and intermediate beginners and experienced observers 2017 Text txt rdacontent Computermedien c rdamedia Online-Ressource cr rdacarrier © The Author(s). 2017 Background High reproducibility and low intra- and interobserver variability are important strengths of cardiac magnetic resonance (CMR). In clinical practice a significant learning curve may however be observed. Basic CMR courses offer an average of 1.4 h dedicated to lecturing and demonstrating left ventricular (LV) function analysis. The purpose of this study was to evaluate the effect of initial teaching on complete and intermediate beginners’ quantitative measurements of LV volumes and function by CMR. Methods Standard clinical cine CMR sequences were acquired in 15 patients. Five observers (two complete beginners, one intermediate, two experienced) measured LV volumes. Before initial evaluation beginners read the SCMR guidelines on CMR analysis. After initial evaluation, beginners participated in a two-hour teaching session including cases and hands-on training, representative for most basic CMR courses, after which it is uncertain to what extent different centres provide continued teaching and feedback in-house. Dice Similarity Coefficient (DSC) assessed delineations. Agreement, accuracy, precision, repeatability and reliability were assessed by Bland-Altman, coefficient of variation, and intraclass correlation coefficient methods. Results Endocardial DSC improved after teaching (+0.14 ± 0.17;p < 0.001) for complete beginners. Low intraobserver variability was found before and after teaching, however with wide limits of agreement. Beginners underestimated volumes by up to 44 ml (EDV), 27 ml (ESV) and overestimated LVM by up to 53 g before teaching, improving to an underestimation of up to 9 ml (EDV), 7 ml (ESV) and an overestimation of up to 30 g (LVM) after teaching. For the intermediate beginner, however, accuracy was quite high already before teaching. Conclusions Initial teaching to complete beginners increases accuracy for assessment of LV volumes, however with high bias and low precision even after standardised teaching as offered in most basic CMR courses. Even though the intermediate beginner showed quite high accuracy already before teaching, precision did generally not improve after standardised teaching. To maintain CMR as a technique known for high accuracy and reproducibility and low intra- and inter-observer variability for quantitative measurements, internationally standardised training should be encouraged including high-quality feedback mechanisms. Objective measurements of training methods, training duration and, above all, quality of assessments are required. CMR (dpeaa)DE-He213 Teaching (dpeaa)DE-He213 Cine (dpeaa)DE-He213 Function (dpeaa)DE-He213 Beginners (dpeaa)DE-He213 Ishida, Masaki aut Sepúlveda-Martínez, Alvaro aut Ryd, Daniel aut Sperling, Johannes aut Engblom, Henrik aut Nagel, Eike aut Enthalten in BMC medical imaging London : BioMed Central, 2001 17(2017), 1 vom: 17. Mai (DE-627)33679911X (DE-600)2061975-3 1471-2342 nnns volume:17 year:2017 number:1 day:17 month:05 https://dx.doi.org/10.1186/s12880-017-0197-5 kostenfrei Volltext GBV_USEFLAG_A SYSFLAG_A GBV_SPRINGER SSG-OLC-PHA GBV_ILN_11 GBV_ILN_20 GBV_ILN_22 GBV_ILN_23 GBV_ILN_24 GBV_ILN_39 GBV_ILN_40 GBV_ILN_60 GBV_ILN_62 GBV_ILN_63 GBV_ILN_65 GBV_ILN_69 GBV_ILN_73 GBV_ILN_74 GBV_ILN_95 GBV_ILN_105 GBV_ILN_110 GBV_ILN_151 GBV_ILN_161 GBV_ILN_170 GBV_ILN_206 GBV_ILN_213 GBV_ILN_230 GBV_ILN_285 GBV_ILN_293 GBV_ILN_602 GBV_ILN_2003 GBV_ILN_2014 GBV_ILN_4012 GBV_ILN_4037 GBV_ILN_4112 GBV_ILN_4125 GBV_ILN_4126 GBV_ILN_4249 GBV_ILN_4305 GBV_ILN_4306 GBV_ILN_4307 GBV_ILN_4313 GBV_ILN_4322 GBV_ILN_4323 GBV_ILN_4324 GBV_ILN_4325 GBV_ILN_4338 GBV_ILN_4367 GBV_ILN_4700 AR 17 2017 1 17 05 |
language |
English |
source |
Enthalten in BMC medical imaging 17(2017), 1 vom: 17. Mai volume:17 year:2017 number:1 day:17 month:05 |
sourceStr |
Enthalten in BMC medical imaging 17(2017), 1 vom: 17. Mai volume:17 year:2017 number:1 day:17 month:05 |
format_phy_str_mv |
Article |
institution |
findex.gbv.de |
topic_facet |
CMR Teaching Cine Function Beginners |
isfreeaccess_bool |
true |
container_title |
BMC medical imaging |
authorswithroles_txt_mv |
Hedström, Erik @@aut@@ Ishida, Masaki @@aut@@ Sepúlveda-Martínez, Alvaro @@aut@@ Ryd, Daniel @@aut@@ Sperling, Johannes @@aut@@ Engblom, Henrik @@aut@@ Nagel, Eike @@aut@@ |
publishDateDaySort_date |
2017-05-17T00:00:00Z |
hierarchy_top_id |
33679911X |
id |
SPR027477096 |
language_de |
englisch |
fullrecord |
<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim"><record><leader>01000caa a22002652 4500</leader><controlfield tag="001">SPR027477096</controlfield><controlfield tag="003">DE-627</controlfield><controlfield tag="005">20230520001109.0</controlfield><controlfield tag="007">cr uuu---uuuuu</controlfield><controlfield tag="008">201007s2017 xx |||||o 00| ||eng c</controlfield><datafield tag="024" ind1="7" ind2=" "><subfield code="a">10.1186/s12880-017-0197-5</subfield><subfield code="2">doi</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-627)SPR027477096</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(SPR)s12880-017-0197-5-e</subfield></datafield><datafield tag="040" ind1=" " ind2=" "><subfield code="a">DE-627</subfield><subfield code="b">ger</subfield><subfield code="c">DE-627</subfield><subfield code="e">rakwb</subfield></datafield><datafield tag="041" ind1=" " ind2=" "><subfield code="a">eng</subfield></datafield><datafield tag="100" ind1="1" ind2=" "><subfield code="a">Hedström, Erik</subfield><subfield code="e">verfasserin</subfield><subfield code="0">(orcid)0000-0003-0041-9357</subfield><subfield code="4">aut</subfield></datafield><datafield tag="245" ind1="1" ind2="4"><subfield code="a">The effect of initial teaching on evaluation of left ventricular volumes by cardiovascular magnetic resonance imaging: comparison between complete and intermediate beginners and experienced observers</subfield></datafield><datafield tag="264" ind1=" " ind2="1"><subfield code="c">2017</subfield></datafield><datafield tag="336" ind1=" " ind2=" "><subfield code="a">Text</subfield><subfield code="b">txt</subfield><subfield code="2">rdacontent</subfield></datafield><datafield tag="337" ind1=" " ind2=" "><subfield code="a">Computermedien</subfield><subfield code="b">c</subfield><subfield code="2">rdamedia</subfield></datafield><datafield tag="338" ind1=" " ind2=" "><subfield code="a">Online-Ressource</subfield><subfield code="b">cr</subfield><subfield code="2">rdacarrier</subfield></datafield><datafield tag="500" ind1=" " ind2=" "><subfield code="a">© The Author(s). 2017</subfield></datafield><datafield tag="520" ind1=" " ind2=" "><subfield code="a">Background High reproducibility and low intra- and interobserver variability are important strengths of cardiac magnetic resonance (CMR). In clinical practice a significant learning curve may however be observed. Basic CMR courses offer an average of 1.4 h dedicated to lecturing and demonstrating left ventricular (LV) function analysis. The purpose of this study was to evaluate the effect of initial teaching on complete and intermediate beginners’ quantitative measurements of LV volumes and function by CMR. Methods Standard clinical cine CMR sequences were acquired in 15 patients. Five observers (two complete beginners, one intermediate, two experienced) measured LV volumes. Before initial evaluation beginners read the SCMR guidelines on CMR analysis. After initial evaluation, beginners participated in a two-hour teaching session including cases and hands-on training, representative for most basic CMR courses, after which it is uncertain to what extent different centres provide continued teaching and feedback in-house. Dice Similarity Coefficient (DSC) assessed delineations. Agreement, accuracy, precision, repeatability and reliability were assessed by Bland-Altman, coefficient of variation, and intraclass correlation coefficient methods. Results Endocardial DSC improved after teaching (+0.14 ± 0.17;p < 0.001) for complete beginners. Low intraobserver variability was found before and after teaching, however with wide limits of agreement. Beginners underestimated volumes by up to 44 ml (EDV), 27 ml (ESV) and overestimated LVM by up to 53 g before teaching, improving to an underestimation of up to 9 ml (EDV), 7 ml (ESV) and an overestimation of up to 30 g (LVM) after teaching. For the intermediate beginner, however, accuracy was quite high already before teaching. Conclusions Initial teaching to complete beginners increases accuracy for assessment of LV volumes, however with high bias and low precision even after standardised teaching as offered in most basic CMR courses. Even though the intermediate beginner showed quite high accuracy already before teaching, precision did generally not improve after standardised teaching. To maintain CMR as a technique known for high accuracy and reproducibility and low intra- and inter-observer variability for quantitative measurements, internationally standardised training should be encouraged including high-quality feedback mechanisms. Objective measurements of training methods, training duration and, above all, quality of assessments are required.</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">CMR</subfield><subfield code="7">(dpeaa)DE-He213</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Teaching</subfield><subfield code="7">(dpeaa)DE-He213</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Cine</subfield><subfield code="7">(dpeaa)DE-He213</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Function</subfield><subfield code="7">(dpeaa)DE-He213</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Beginners</subfield><subfield code="7">(dpeaa)DE-He213</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Ishida, Masaki</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Sepúlveda-Martínez, Alvaro</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Ryd, Daniel</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Sperling, Johannes</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Engblom, Henrik</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Nagel, Eike</subfield><subfield code="4">aut</subfield></datafield><datafield tag="773" ind1="0" ind2="8"><subfield code="i">Enthalten in</subfield><subfield code="t">BMC medical imaging</subfield><subfield code="d">London : BioMed Central, 2001</subfield><subfield code="g">17(2017), 1 vom: 17. Mai</subfield><subfield code="w">(DE-627)33679911X</subfield><subfield code="w">(DE-600)2061975-3</subfield><subfield code="x">1471-2342</subfield><subfield code="7">nnns</subfield></datafield><datafield tag="773" ind1="1" ind2="8"><subfield code="g">volume:17</subfield><subfield code="g">year:2017</subfield><subfield code="g">number:1</subfield><subfield code="g">day:17</subfield><subfield code="g">month:05</subfield></datafield><datafield tag="856" ind1="4" ind2="0"><subfield code="u">https://dx.doi.org/10.1186/s12880-017-0197-5</subfield><subfield code="z">kostenfrei</subfield><subfield code="3">Volltext</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_USEFLAG_A</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">SYSFLAG_A</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_SPRINGER</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">SSG-OLC-PHA</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_11</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_20</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_22</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_23</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_24</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_39</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_40</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_60</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_62</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_63</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_65</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_69</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_73</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_74</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_95</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_105</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_110</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_151</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_161</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_170</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_206</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_213</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_230</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_285</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_293</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_602</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2003</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2014</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4012</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4037</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4112</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4125</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4126</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4249</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4305</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4306</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4307</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4313</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4322</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4323</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4324</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4325</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4338</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4367</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4700</subfield></datafield><datafield tag="951" ind1=" " ind2=" "><subfield code="a">AR</subfield></datafield><datafield tag="952" ind1=" " ind2=" "><subfield code="d">17</subfield><subfield code="j">2017</subfield><subfield code="e">1</subfield><subfield code="b">17</subfield><subfield code="c">05</subfield></datafield></record></collection>
|
author |
Hedström, Erik |
spellingShingle |
Hedström, Erik misc CMR misc Teaching misc Cine misc Function misc Beginners The effect of initial teaching on evaluation of left ventricular volumes by cardiovascular magnetic resonance imaging: comparison between complete and intermediate beginners and experienced observers |
authorStr |
Hedström, Erik |
ppnlink_with_tag_str_mv |
@@773@@(DE-627)33679911X |
format |
electronic Article |
delete_txt_mv |
keep |
author_role |
aut aut aut aut aut aut aut |
collection |
springer |
remote_str |
true |
illustrated |
Not Illustrated |
issn |
1471-2342 |
topic_title |
The effect of initial teaching on evaluation of left ventricular volumes by cardiovascular magnetic resonance imaging: comparison between complete and intermediate beginners and experienced observers CMR (dpeaa)DE-He213 Teaching (dpeaa)DE-He213 Cine (dpeaa)DE-He213 Function (dpeaa)DE-He213 Beginners (dpeaa)DE-He213 |
topic |
misc CMR misc Teaching misc Cine misc Function misc Beginners |
topic_unstemmed |
misc CMR misc Teaching misc Cine misc Function misc Beginners |
topic_browse |
misc CMR misc Teaching misc Cine misc Function misc Beginners |
format_facet |
Elektronische Aufsätze Aufsätze Elektronische Ressource |
format_main_str_mv |
Text Zeitschrift/Artikel |
carriertype_str_mv |
cr |
hierarchy_parent_title |
BMC medical imaging |
hierarchy_parent_id |
33679911X |
hierarchy_top_title |
BMC medical imaging |
isfreeaccess_txt |
true |
familylinks_str_mv |
(DE-627)33679911X (DE-600)2061975-3 |
title |
The effect of initial teaching on evaluation of left ventricular volumes by cardiovascular magnetic resonance imaging: comparison between complete and intermediate beginners and experienced observers |
ctrlnum |
(DE-627)SPR027477096 (SPR)s12880-017-0197-5-e |
title_full |
The effect of initial teaching on evaluation of left ventricular volumes by cardiovascular magnetic resonance imaging: comparison between complete and intermediate beginners and experienced observers |
author_sort |
Hedström, Erik |
journal |
BMC medical imaging |
journalStr |
BMC medical imaging |
lang_code |
eng |
isOA_bool |
true |
recordtype |
marc |
publishDateSort |
2017 |
contenttype_str_mv |
txt |
author_browse |
Hedström, Erik Ishida, Masaki Sepúlveda-Martínez, Alvaro Ryd, Daniel Sperling, Johannes Engblom, Henrik Nagel, Eike |
container_volume |
17 |
format_se |
Elektronische Aufsätze |
author-letter |
Hedström, Erik |
doi_str_mv |
10.1186/s12880-017-0197-5 |
normlink |
(ORCID)0000-0003-0041-9357 |
normlink_prefix_str_mv |
(orcid)0000-0003-0041-9357 |
title_sort |
effect of initial teaching on evaluation of left ventricular volumes by cardiovascular magnetic resonance imaging: comparison between complete and intermediate beginners and experienced observers |
title_auth |
The effect of initial teaching on evaluation of left ventricular volumes by cardiovascular magnetic resonance imaging: comparison between complete and intermediate beginners and experienced observers |
abstract |
Background High reproducibility and low intra- and interobserver variability are important strengths of cardiac magnetic resonance (CMR). In clinical practice a significant learning curve may however be observed. Basic CMR courses offer an average of 1.4 h dedicated to lecturing and demonstrating left ventricular (LV) function analysis. The purpose of this study was to evaluate the effect of initial teaching on complete and intermediate beginners’ quantitative measurements of LV volumes and function by CMR. Methods Standard clinical cine CMR sequences were acquired in 15 patients. Five observers (two complete beginners, one intermediate, two experienced) measured LV volumes. Before initial evaluation beginners read the SCMR guidelines on CMR analysis. After initial evaluation, beginners participated in a two-hour teaching session including cases and hands-on training, representative for most basic CMR courses, after which it is uncertain to what extent different centres provide continued teaching and feedback in-house. Dice Similarity Coefficient (DSC) assessed delineations. Agreement, accuracy, precision, repeatability and reliability were assessed by Bland-Altman, coefficient of variation, and intraclass correlation coefficient methods. Results Endocardial DSC improved after teaching (+0.14 ± 0.17;p < 0.001) for complete beginners. Low intraobserver variability was found before and after teaching, however with wide limits of agreement. Beginners underestimated volumes by up to 44 ml (EDV), 27 ml (ESV) and overestimated LVM by up to 53 g before teaching, improving to an underestimation of up to 9 ml (EDV), 7 ml (ESV) and an overestimation of up to 30 g (LVM) after teaching. For the intermediate beginner, however, accuracy was quite high already before teaching. Conclusions Initial teaching to complete beginners increases accuracy for assessment of LV volumes, however with high bias and low precision even after standardised teaching as offered in most basic CMR courses. Even though the intermediate beginner showed quite high accuracy already before teaching, precision did generally not improve after standardised teaching. To maintain CMR as a technique known for high accuracy and reproducibility and low intra- and inter-observer variability for quantitative measurements, internationally standardised training should be encouraged including high-quality feedback mechanisms. Objective measurements of training methods, training duration and, above all, quality of assessments are required. © The Author(s). 2017 |
abstractGer |
Background High reproducibility and low intra- and interobserver variability are important strengths of cardiac magnetic resonance (CMR). In clinical practice a significant learning curve may however be observed. Basic CMR courses offer an average of 1.4 h dedicated to lecturing and demonstrating left ventricular (LV) function analysis. The purpose of this study was to evaluate the effect of initial teaching on complete and intermediate beginners’ quantitative measurements of LV volumes and function by CMR. Methods Standard clinical cine CMR sequences were acquired in 15 patients. Five observers (two complete beginners, one intermediate, two experienced) measured LV volumes. Before initial evaluation beginners read the SCMR guidelines on CMR analysis. After initial evaluation, beginners participated in a two-hour teaching session including cases and hands-on training, representative for most basic CMR courses, after which it is uncertain to what extent different centres provide continued teaching and feedback in-house. Dice Similarity Coefficient (DSC) assessed delineations. Agreement, accuracy, precision, repeatability and reliability were assessed by Bland-Altman, coefficient of variation, and intraclass correlation coefficient methods. Results Endocardial DSC improved after teaching (+0.14 ± 0.17;p < 0.001) for complete beginners. Low intraobserver variability was found before and after teaching, however with wide limits of agreement. Beginners underestimated volumes by up to 44 ml (EDV), 27 ml (ESV) and overestimated LVM by up to 53 g before teaching, improving to an underestimation of up to 9 ml (EDV), 7 ml (ESV) and an overestimation of up to 30 g (LVM) after teaching. For the intermediate beginner, however, accuracy was quite high already before teaching. Conclusions Initial teaching to complete beginners increases accuracy for assessment of LV volumes, however with high bias and low precision even after standardised teaching as offered in most basic CMR courses. Even though the intermediate beginner showed quite high accuracy already before teaching, precision did generally not improve after standardised teaching. To maintain CMR as a technique known for high accuracy and reproducibility and low intra- and inter-observer variability for quantitative measurements, internationally standardised training should be encouraged including high-quality feedback mechanisms. Objective measurements of training methods, training duration and, above all, quality of assessments are required. © The Author(s). 2017 |
abstract_unstemmed |
Background High reproducibility and low intra- and interobserver variability are important strengths of cardiac magnetic resonance (CMR). In clinical practice a significant learning curve may however be observed. Basic CMR courses offer an average of 1.4 h dedicated to lecturing and demonstrating left ventricular (LV) function analysis. The purpose of this study was to evaluate the effect of initial teaching on complete and intermediate beginners’ quantitative measurements of LV volumes and function by CMR. Methods Standard clinical cine CMR sequences were acquired in 15 patients. Five observers (two complete beginners, one intermediate, two experienced) measured LV volumes. Before initial evaluation beginners read the SCMR guidelines on CMR analysis. After initial evaluation, beginners participated in a two-hour teaching session including cases and hands-on training, representative for most basic CMR courses, after which it is uncertain to what extent different centres provide continued teaching and feedback in-house. Dice Similarity Coefficient (DSC) assessed delineations. Agreement, accuracy, precision, repeatability and reliability were assessed by Bland-Altman, coefficient of variation, and intraclass correlation coefficient methods. Results Endocardial DSC improved after teaching (+0.14 ± 0.17;p < 0.001) for complete beginners. Low intraobserver variability was found before and after teaching, however with wide limits of agreement. Beginners underestimated volumes by up to 44 ml (EDV), 27 ml (ESV) and overestimated LVM by up to 53 g before teaching, improving to an underestimation of up to 9 ml (EDV), 7 ml (ESV) and an overestimation of up to 30 g (LVM) after teaching. For the intermediate beginner, however, accuracy was quite high already before teaching. Conclusions Initial teaching to complete beginners increases accuracy for assessment of LV volumes, however with high bias and low precision even after standardised teaching as offered in most basic CMR courses. Even though the intermediate beginner showed quite high accuracy already before teaching, precision did generally not improve after standardised teaching. To maintain CMR as a technique known for high accuracy and reproducibility and low intra- and inter-observer variability for quantitative measurements, internationally standardised training should be encouraged including high-quality feedback mechanisms. Objective measurements of training methods, training duration and, above all, quality of assessments are required. © The Author(s). 2017 |
collection_details |
GBV_USEFLAG_A SYSFLAG_A GBV_SPRINGER SSG-OLC-PHA GBV_ILN_11 GBV_ILN_20 GBV_ILN_22 GBV_ILN_23 GBV_ILN_24 GBV_ILN_39 GBV_ILN_40 GBV_ILN_60 GBV_ILN_62 GBV_ILN_63 GBV_ILN_65 GBV_ILN_69 GBV_ILN_73 GBV_ILN_74 GBV_ILN_95 GBV_ILN_105 GBV_ILN_110 GBV_ILN_151 GBV_ILN_161 GBV_ILN_170 GBV_ILN_206 GBV_ILN_213 GBV_ILN_230 GBV_ILN_285 GBV_ILN_293 GBV_ILN_602 GBV_ILN_2003 GBV_ILN_2014 GBV_ILN_4012 GBV_ILN_4037 GBV_ILN_4112 GBV_ILN_4125 GBV_ILN_4126 GBV_ILN_4249 GBV_ILN_4305 GBV_ILN_4306 GBV_ILN_4307 GBV_ILN_4313 GBV_ILN_4322 GBV_ILN_4323 GBV_ILN_4324 GBV_ILN_4325 GBV_ILN_4338 GBV_ILN_4367 GBV_ILN_4700 |
container_issue |
1 |
title_short |
The effect of initial teaching on evaluation of left ventricular volumes by cardiovascular magnetic resonance imaging: comparison between complete and intermediate beginners and experienced observers |
url |
https://dx.doi.org/10.1186/s12880-017-0197-5 |
remote_bool |
true |
author2 |
Ishida, Masaki Sepúlveda-Martínez, Alvaro Ryd, Daniel Sperling, Johannes Engblom, Henrik Nagel, Eike |
author2Str |
Ishida, Masaki Sepúlveda-Martínez, Alvaro Ryd, Daniel Sperling, Johannes Engblom, Henrik Nagel, Eike |
ppnlink |
33679911X |
mediatype_str_mv |
c |
isOA_txt |
true |
hochschulschrift_bool |
false |
doi_str |
10.1186/s12880-017-0197-5 |
up_date |
2024-07-04T02:02:16.130Z |
_version_ |
1803612099583148033 |
fullrecord_marcxml |
<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim"><record><leader>01000caa a22002652 4500</leader><controlfield tag="001">SPR027477096</controlfield><controlfield tag="003">DE-627</controlfield><controlfield tag="005">20230520001109.0</controlfield><controlfield tag="007">cr uuu---uuuuu</controlfield><controlfield tag="008">201007s2017 xx |||||o 00| ||eng c</controlfield><datafield tag="024" ind1="7" ind2=" "><subfield code="a">10.1186/s12880-017-0197-5</subfield><subfield code="2">doi</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-627)SPR027477096</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(SPR)s12880-017-0197-5-e</subfield></datafield><datafield tag="040" ind1=" " ind2=" "><subfield code="a">DE-627</subfield><subfield code="b">ger</subfield><subfield code="c">DE-627</subfield><subfield code="e">rakwb</subfield></datafield><datafield tag="041" ind1=" " ind2=" "><subfield code="a">eng</subfield></datafield><datafield tag="100" ind1="1" ind2=" "><subfield code="a">Hedström, Erik</subfield><subfield code="e">verfasserin</subfield><subfield code="0">(orcid)0000-0003-0041-9357</subfield><subfield code="4">aut</subfield></datafield><datafield tag="245" ind1="1" ind2="4"><subfield code="a">The effect of initial teaching on evaluation of left ventricular volumes by cardiovascular magnetic resonance imaging: comparison between complete and intermediate beginners and experienced observers</subfield></datafield><datafield tag="264" ind1=" " ind2="1"><subfield code="c">2017</subfield></datafield><datafield tag="336" ind1=" " ind2=" "><subfield code="a">Text</subfield><subfield code="b">txt</subfield><subfield code="2">rdacontent</subfield></datafield><datafield tag="337" ind1=" " ind2=" "><subfield code="a">Computermedien</subfield><subfield code="b">c</subfield><subfield code="2">rdamedia</subfield></datafield><datafield tag="338" ind1=" " ind2=" "><subfield code="a">Online-Ressource</subfield><subfield code="b">cr</subfield><subfield code="2">rdacarrier</subfield></datafield><datafield tag="500" ind1=" " ind2=" "><subfield code="a">© The Author(s). 2017</subfield></datafield><datafield tag="520" ind1=" " ind2=" "><subfield code="a">Background High reproducibility and low intra- and interobserver variability are important strengths of cardiac magnetic resonance (CMR). In clinical practice a significant learning curve may however be observed. Basic CMR courses offer an average of 1.4 h dedicated to lecturing and demonstrating left ventricular (LV) function analysis. The purpose of this study was to evaluate the effect of initial teaching on complete and intermediate beginners’ quantitative measurements of LV volumes and function by CMR. Methods Standard clinical cine CMR sequences were acquired in 15 patients. Five observers (two complete beginners, one intermediate, two experienced) measured LV volumes. Before initial evaluation beginners read the SCMR guidelines on CMR analysis. After initial evaluation, beginners participated in a two-hour teaching session including cases and hands-on training, representative for most basic CMR courses, after which it is uncertain to what extent different centres provide continued teaching and feedback in-house. Dice Similarity Coefficient (DSC) assessed delineations. Agreement, accuracy, precision, repeatability and reliability were assessed by Bland-Altman, coefficient of variation, and intraclass correlation coefficient methods. Results Endocardial DSC improved after teaching (+0.14 ± 0.17;p < 0.001) for complete beginners. Low intraobserver variability was found before and after teaching, however with wide limits of agreement. Beginners underestimated volumes by up to 44 ml (EDV), 27 ml (ESV) and overestimated LVM by up to 53 g before teaching, improving to an underestimation of up to 9 ml (EDV), 7 ml (ESV) and an overestimation of up to 30 g (LVM) after teaching. For the intermediate beginner, however, accuracy was quite high already before teaching. Conclusions Initial teaching to complete beginners increases accuracy for assessment of LV volumes, however with high bias and low precision even after standardised teaching as offered in most basic CMR courses. Even though the intermediate beginner showed quite high accuracy already before teaching, precision did generally not improve after standardised teaching. To maintain CMR as a technique known for high accuracy and reproducibility and low intra- and inter-observer variability for quantitative measurements, internationally standardised training should be encouraged including high-quality feedback mechanisms. Objective measurements of training methods, training duration and, above all, quality of assessments are required.</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">CMR</subfield><subfield code="7">(dpeaa)DE-He213</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Teaching</subfield><subfield code="7">(dpeaa)DE-He213</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Cine</subfield><subfield code="7">(dpeaa)DE-He213</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Function</subfield><subfield code="7">(dpeaa)DE-He213</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Beginners</subfield><subfield code="7">(dpeaa)DE-He213</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Ishida, Masaki</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Sepúlveda-Martínez, Alvaro</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Ryd, Daniel</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Sperling, Johannes</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Engblom, Henrik</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Nagel, Eike</subfield><subfield code="4">aut</subfield></datafield><datafield tag="773" ind1="0" ind2="8"><subfield code="i">Enthalten in</subfield><subfield code="t">BMC medical imaging</subfield><subfield code="d">London : BioMed Central, 2001</subfield><subfield code="g">17(2017), 1 vom: 17. Mai</subfield><subfield code="w">(DE-627)33679911X</subfield><subfield code="w">(DE-600)2061975-3</subfield><subfield code="x">1471-2342</subfield><subfield code="7">nnns</subfield></datafield><datafield tag="773" ind1="1" ind2="8"><subfield code="g">volume:17</subfield><subfield code="g">year:2017</subfield><subfield code="g">number:1</subfield><subfield code="g">day:17</subfield><subfield code="g">month:05</subfield></datafield><datafield tag="856" ind1="4" ind2="0"><subfield code="u">https://dx.doi.org/10.1186/s12880-017-0197-5</subfield><subfield code="z">kostenfrei</subfield><subfield code="3">Volltext</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_USEFLAG_A</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">SYSFLAG_A</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_SPRINGER</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">SSG-OLC-PHA</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_11</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_20</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_22</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_23</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_24</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_39</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_40</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_60</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_62</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_63</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_65</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_69</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_73</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_74</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_95</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_105</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_110</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_151</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_161</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_170</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_206</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_213</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_230</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_285</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_293</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_602</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2003</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2014</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4012</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4037</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4112</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4125</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4126</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4249</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4305</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4306</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4307</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4313</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4322</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4323</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4324</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4325</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4338</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4367</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4700</subfield></datafield><datafield tag="951" ind1=" " ind2=" "><subfield code="a">AR</subfield></datafield><datafield tag="952" ind1=" " ind2=" "><subfield code="d">17</subfield><subfield code="j">2017</subfield><subfield code="e">1</subfield><subfield code="b">17</subfield><subfield code="c">05</subfield></datafield></record></collection>
|
score |
7.4001474 |