Re-emphasizing the concept of adequacy of intraoperative assessment of the axillary sentinel lymph nodes for identifying nodal positivity during breast cancer surgery
Background Although sentinel lymph node (SLN) biopsy is a standard of care for the evaluation of the axillary lymph nodes during breast cancer surgery, a substantial degree of variation exists among individual surgeons as to what represents an adequate assessment. The aim of the current study was to...
Ausführliche Beschreibung
Autor*in: |
Povoski, Stephen P [verfasserIn] |
---|
Format: |
E-Artikel |
---|---|
Sprache: |
Englisch |
Erschienen: |
2007 |
---|
Schlagwörter: |
---|
Anmerkung: |
© Povoski et al; licensee BioMed Central Ltd. 2007 |
---|
Übergeordnetes Werk: |
Enthalten in: World journal of surgical oncology - London : Biomed Central, 2003, 5(2007), 1 vom: 09. Feb. |
---|---|
Übergeordnetes Werk: |
volume:5 ; year:2007 ; number:1 ; day:09 ; month:02 |
Links: |
---|
DOI / URN: |
10.1186/1477-7819-5-18 |
---|
Katalog-ID: |
SPR028811208 |
---|
LEADER | 01000caa a22002652 4500 | ||
---|---|---|---|
001 | SPR028811208 | ||
003 | DE-627 | ||
005 | 20230519150041.0 | ||
007 | cr uuu---uuuuu | ||
008 | 201007s2007 xx |||||o 00| ||eng c | ||
024 | 7 | |a 10.1186/1477-7819-5-18 |2 doi | |
035 | |a (DE-627)SPR028811208 | ||
035 | |a (SPR)1477-7819-5-18-e | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
100 | 1 | |a Povoski, Stephen P |e verfasserin |4 aut | |
245 | 1 | 0 | |a Re-emphasizing the concept of adequacy of intraoperative assessment of the axillary sentinel lymph nodes for identifying nodal positivity during breast cancer surgery |
264 | 1 | |c 2007 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a Computermedien |b c |2 rdamedia | ||
338 | |a Online-Ressource |b cr |2 rdacarrier | ||
500 | |a © Povoski et al; licensee BioMed Central Ltd. 2007 | ||
520 | |a Background Although sentinel lymph node (SLN) biopsy is a standard of care for the evaluation of the axillary lymph nodes during breast cancer surgery, a substantial degree of variation exists among individual surgeons as to what represents an adequate assessment. The aim of the current study was to assess when metastatic disease was first identified within consecutively harvested SLN candidates for invasive breast cancers demonstrating a positive SLN. Methods We retrospectively analyzed a series of 400 breast cancers from a recently published prospective randomized clinical trial. A combined radiocolloid and blue dye technique was used. All potential SLN candidates, containing counts of at least 10% of the hottest SLN and/or containing blue dye, were harvested and were consecutively numbered in the order of the decreasing level of counts (with the hottest SLN representing SLN #1). Results Among 371 invasive breast cancers, a SLN was identified within 353 cases (95%). Mean number of SLNs identified was 2.5 (range, 1 to 9), with a single SLN identified in 104 (29%) cases, two identified in 110 (31%), three identified in 73 (21%), four identified in 35 (10%), five identified in 16 (5%), and six or more identified in 15 (4%). A positive SLN was found in 104 (29%) cases. SLN #1 was the first positive SLN in 86 (83%). SLN #2 was the first positive SLN in 15 (14%). SLN #3, SLN #4, and SLN #5 were the first positive SLN in one case (1%) each. A positive SLN was found in 18% (19/104) of cases when a single SLN was identified, as compared to in 34% (85/249) when two or more SLNs were identified (P = 0.003). Conclusion The accurate and optimal assessment of the axilla during breast cancer surgery requires persistence and diligence for attempting to identify all potential SLN candidates in order to avoid failing to recognize a positive SLN. The scenario in which only a single negative SLN candidate is intraoperatively identified is one that should raise some concern to the operating surgeon. | ||
650 | 4 | |a Sentinel Lymph Node |7 (dpeaa)DE-He213 | |
650 | 4 | |a Sentinel Lymph Node Biopsy |7 (dpeaa)DE-He213 | |
650 | 4 | |a Invasive Breast Cancer |7 (dpeaa)DE-He213 | |
650 | 4 | |a Axillary Lymph Node Dissection |7 (dpeaa)DE-He213 | |
650 | 4 | |a Positive Sentinel Lymph Node |7 (dpeaa)DE-He213 | |
700 | 1 | |a Young, Donn C |4 aut | |
700 | 1 | |a Walker, Michael J |4 aut | |
700 | 1 | |a Carson, William E |4 aut | |
700 | 1 | |a Yee, Lisa D |4 aut | |
700 | 1 | |a Agnese, Doreen M |4 aut | |
700 | 1 | |a Farrar, William B |4 aut | |
773 | 0 | 8 | |i Enthalten in |t World journal of surgical oncology |d London : Biomed Central, 2003 |g 5(2007), 1 vom: 09. Feb. |w (DE-627)369082907 |w (DE-600)2118383-1 |x 1477-7819 |7 nnns |
773 | 1 | 8 | |g volume:5 |g year:2007 |g number:1 |g day:09 |g month:02 |
856 | 4 | 0 | |u https://dx.doi.org/10.1186/1477-7819-5-18 |z kostenfrei |3 Volltext |
912 | |a GBV_USEFLAG_A | ||
912 | |a SYSFLAG_A | ||
912 | |a GBV_SPRINGER | ||
912 | |a SSG-OLC-PHA | ||
912 | |a GBV_ILN_20 | ||
912 | |a GBV_ILN_22 | ||
912 | |a GBV_ILN_23 | ||
912 | |a GBV_ILN_24 | ||
912 | |a GBV_ILN_39 | ||
912 | |a GBV_ILN_40 | ||
912 | |a GBV_ILN_60 | ||
912 | |a GBV_ILN_62 | ||
912 | |a GBV_ILN_63 | ||
912 | |a GBV_ILN_65 | ||
912 | |a GBV_ILN_69 | ||
912 | |a GBV_ILN_73 | ||
912 | |a GBV_ILN_74 | ||
912 | |a GBV_ILN_95 | ||
912 | |a GBV_ILN_105 | ||
912 | |a GBV_ILN_110 | ||
912 | |a GBV_ILN_151 | ||
912 | |a GBV_ILN_161 | ||
912 | |a GBV_ILN_170 | ||
912 | |a GBV_ILN_206 | ||
912 | |a GBV_ILN_213 | ||
912 | |a GBV_ILN_230 | ||
912 | |a GBV_ILN_285 | ||
912 | |a GBV_ILN_293 | ||
912 | |a GBV_ILN_602 | ||
912 | |a GBV_ILN_2014 | ||
912 | |a GBV_ILN_4012 | ||
912 | |a GBV_ILN_4037 | ||
912 | |a GBV_ILN_4112 | ||
912 | |a GBV_ILN_4125 | ||
912 | |a GBV_ILN_4126 | ||
912 | |a GBV_ILN_4249 | ||
912 | |a GBV_ILN_4305 | ||
912 | |a GBV_ILN_4306 | ||
912 | |a GBV_ILN_4307 | ||
912 | |a GBV_ILN_4313 | ||
912 | |a GBV_ILN_4322 | ||
912 | |a GBV_ILN_4323 | ||
912 | |a GBV_ILN_4324 | ||
912 | |a GBV_ILN_4325 | ||
912 | |a GBV_ILN_4338 | ||
912 | |a GBV_ILN_4367 | ||
912 | |a GBV_ILN_4700 | ||
951 | |a AR | ||
952 | |d 5 |j 2007 |e 1 |b 09 |c 02 |
author_variant |
s p p sp spp d c y dc dcy m j w mj mjw w e c we wec l d y ld ldy d m a dm dma w b f wb wbf |
---|---|
matchkey_str |
article:14777819:2007----::emhsznteocpoaeucoitaprtvassmnotexlayetnlypndsoietfigoa |
hierarchy_sort_str |
2007 |
publishDate |
2007 |
allfields |
10.1186/1477-7819-5-18 doi (DE-627)SPR028811208 (SPR)1477-7819-5-18-e DE-627 ger DE-627 rakwb eng Povoski, Stephen P verfasserin aut Re-emphasizing the concept of adequacy of intraoperative assessment of the axillary sentinel lymph nodes for identifying nodal positivity during breast cancer surgery 2007 Text txt rdacontent Computermedien c rdamedia Online-Ressource cr rdacarrier © Povoski et al; licensee BioMed Central Ltd. 2007 Background Although sentinel lymph node (SLN) biopsy is a standard of care for the evaluation of the axillary lymph nodes during breast cancer surgery, a substantial degree of variation exists among individual surgeons as to what represents an adequate assessment. The aim of the current study was to assess when metastatic disease was first identified within consecutively harvested SLN candidates for invasive breast cancers demonstrating a positive SLN. Methods We retrospectively analyzed a series of 400 breast cancers from a recently published prospective randomized clinical trial. A combined radiocolloid and blue dye technique was used. All potential SLN candidates, containing counts of at least 10% of the hottest SLN and/or containing blue dye, were harvested and were consecutively numbered in the order of the decreasing level of counts (with the hottest SLN representing SLN #1). Results Among 371 invasive breast cancers, a SLN was identified within 353 cases (95%). Mean number of SLNs identified was 2.5 (range, 1 to 9), with a single SLN identified in 104 (29%) cases, two identified in 110 (31%), three identified in 73 (21%), four identified in 35 (10%), five identified in 16 (5%), and six or more identified in 15 (4%). A positive SLN was found in 104 (29%) cases. SLN #1 was the first positive SLN in 86 (83%). SLN #2 was the first positive SLN in 15 (14%). SLN #3, SLN #4, and SLN #5 were the first positive SLN in one case (1%) each. A positive SLN was found in 18% (19/104) of cases when a single SLN was identified, as compared to in 34% (85/249) when two or more SLNs were identified (P = 0.003). Conclusion The accurate and optimal assessment of the axilla during breast cancer surgery requires persistence and diligence for attempting to identify all potential SLN candidates in order to avoid failing to recognize a positive SLN. The scenario in which only a single negative SLN candidate is intraoperatively identified is one that should raise some concern to the operating surgeon. Sentinel Lymph Node (dpeaa)DE-He213 Sentinel Lymph Node Biopsy (dpeaa)DE-He213 Invasive Breast Cancer (dpeaa)DE-He213 Axillary Lymph Node Dissection (dpeaa)DE-He213 Positive Sentinel Lymph Node (dpeaa)DE-He213 Young, Donn C aut Walker, Michael J aut Carson, William E aut Yee, Lisa D aut Agnese, Doreen M aut Farrar, William B aut Enthalten in World journal of surgical oncology London : Biomed Central, 2003 5(2007), 1 vom: 09. Feb. (DE-627)369082907 (DE-600)2118383-1 1477-7819 nnns volume:5 year:2007 number:1 day:09 month:02 https://dx.doi.org/10.1186/1477-7819-5-18 kostenfrei Volltext GBV_USEFLAG_A SYSFLAG_A GBV_SPRINGER SSG-OLC-PHA GBV_ILN_20 GBV_ILN_22 GBV_ILN_23 GBV_ILN_24 GBV_ILN_39 GBV_ILN_40 GBV_ILN_60 GBV_ILN_62 GBV_ILN_63 GBV_ILN_65 GBV_ILN_69 GBV_ILN_73 GBV_ILN_74 GBV_ILN_95 GBV_ILN_105 GBV_ILN_110 GBV_ILN_151 GBV_ILN_161 GBV_ILN_170 GBV_ILN_206 GBV_ILN_213 GBV_ILN_230 GBV_ILN_285 GBV_ILN_293 GBV_ILN_602 GBV_ILN_2014 GBV_ILN_4012 GBV_ILN_4037 GBV_ILN_4112 GBV_ILN_4125 GBV_ILN_4126 GBV_ILN_4249 GBV_ILN_4305 GBV_ILN_4306 GBV_ILN_4307 GBV_ILN_4313 GBV_ILN_4322 GBV_ILN_4323 GBV_ILN_4324 GBV_ILN_4325 GBV_ILN_4338 GBV_ILN_4367 GBV_ILN_4700 AR 5 2007 1 09 02 |
spelling |
10.1186/1477-7819-5-18 doi (DE-627)SPR028811208 (SPR)1477-7819-5-18-e DE-627 ger DE-627 rakwb eng Povoski, Stephen P verfasserin aut Re-emphasizing the concept of adequacy of intraoperative assessment of the axillary sentinel lymph nodes for identifying nodal positivity during breast cancer surgery 2007 Text txt rdacontent Computermedien c rdamedia Online-Ressource cr rdacarrier © Povoski et al; licensee BioMed Central Ltd. 2007 Background Although sentinel lymph node (SLN) biopsy is a standard of care for the evaluation of the axillary lymph nodes during breast cancer surgery, a substantial degree of variation exists among individual surgeons as to what represents an adequate assessment. The aim of the current study was to assess when metastatic disease was first identified within consecutively harvested SLN candidates for invasive breast cancers demonstrating a positive SLN. Methods We retrospectively analyzed a series of 400 breast cancers from a recently published prospective randomized clinical trial. A combined radiocolloid and blue dye technique was used. All potential SLN candidates, containing counts of at least 10% of the hottest SLN and/or containing blue dye, were harvested and were consecutively numbered in the order of the decreasing level of counts (with the hottest SLN representing SLN #1). Results Among 371 invasive breast cancers, a SLN was identified within 353 cases (95%). Mean number of SLNs identified was 2.5 (range, 1 to 9), with a single SLN identified in 104 (29%) cases, two identified in 110 (31%), three identified in 73 (21%), four identified in 35 (10%), five identified in 16 (5%), and six or more identified in 15 (4%). A positive SLN was found in 104 (29%) cases. SLN #1 was the first positive SLN in 86 (83%). SLN #2 was the first positive SLN in 15 (14%). SLN #3, SLN #4, and SLN #5 were the first positive SLN in one case (1%) each. A positive SLN was found in 18% (19/104) of cases when a single SLN was identified, as compared to in 34% (85/249) when two or more SLNs were identified (P = 0.003). Conclusion The accurate and optimal assessment of the axilla during breast cancer surgery requires persistence and diligence for attempting to identify all potential SLN candidates in order to avoid failing to recognize a positive SLN. The scenario in which only a single negative SLN candidate is intraoperatively identified is one that should raise some concern to the operating surgeon. Sentinel Lymph Node (dpeaa)DE-He213 Sentinel Lymph Node Biopsy (dpeaa)DE-He213 Invasive Breast Cancer (dpeaa)DE-He213 Axillary Lymph Node Dissection (dpeaa)DE-He213 Positive Sentinel Lymph Node (dpeaa)DE-He213 Young, Donn C aut Walker, Michael J aut Carson, William E aut Yee, Lisa D aut Agnese, Doreen M aut Farrar, William B aut Enthalten in World journal of surgical oncology London : Biomed Central, 2003 5(2007), 1 vom: 09. Feb. (DE-627)369082907 (DE-600)2118383-1 1477-7819 nnns volume:5 year:2007 number:1 day:09 month:02 https://dx.doi.org/10.1186/1477-7819-5-18 kostenfrei Volltext GBV_USEFLAG_A SYSFLAG_A GBV_SPRINGER SSG-OLC-PHA GBV_ILN_20 GBV_ILN_22 GBV_ILN_23 GBV_ILN_24 GBV_ILN_39 GBV_ILN_40 GBV_ILN_60 GBV_ILN_62 GBV_ILN_63 GBV_ILN_65 GBV_ILN_69 GBV_ILN_73 GBV_ILN_74 GBV_ILN_95 GBV_ILN_105 GBV_ILN_110 GBV_ILN_151 GBV_ILN_161 GBV_ILN_170 GBV_ILN_206 GBV_ILN_213 GBV_ILN_230 GBV_ILN_285 GBV_ILN_293 GBV_ILN_602 GBV_ILN_2014 GBV_ILN_4012 GBV_ILN_4037 GBV_ILN_4112 GBV_ILN_4125 GBV_ILN_4126 GBV_ILN_4249 GBV_ILN_4305 GBV_ILN_4306 GBV_ILN_4307 GBV_ILN_4313 GBV_ILN_4322 GBV_ILN_4323 GBV_ILN_4324 GBV_ILN_4325 GBV_ILN_4338 GBV_ILN_4367 GBV_ILN_4700 AR 5 2007 1 09 02 |
allfields_unstemmed |
10.1186/1477-7819-5-18 doi (DE-627)SPR028811208 (SPR)1477-7819-5-18-e DE-627 ger DE-627 rakwb eng Povoski, Stephen P verfasserin aut Re-emphasizing the concept of adequacy of intraoperative assessment of the axillary sentinel lymph nodes for identifying nodal positivity during breast cancer surgery 2007 Text txt rdacontent Computermedien c rdamedia Online-Ressource cr rdacarrier © Povoski et al; licensee BioMed Central Ltd. 2007 Background Although sentinel lymph node (SLN) biopsy is a standard of care for the evaluation of the axillary lymph nodes during breast cancer surgery, a substantial degree of variation exists among individual surgeons as to what represents an adequate assessment. The aim of the current study was to assess when metastatic disease was first identified within consecutively harvested SLN candidates for invasive breast cancers demonstrating a positive SLN. Methods We retrospectively analyzed a series of 400 breast cancers from a recently published prospective randomized clinical trial. A combined radiocolloid and blue dye technique was used. All potential SLN candidates, containing counts of at least 10% of the hottest SLN and/or containing blue dye, were harvested and were consecutively numbered in the order of the decreasing level of counts (with the hottest SLN representing SLN #1). Results Among 371 invasive breast cancers, a SLN was identified within 353 cases (95%). Mean number of SLNs identified was 2.5 (range, 1 to 9), with a single SLN identified in 104 (29%) cases, two identified in 110 (31%), three identified in 73 (21%), four identified in 35 (10%), five identified in 16 (5%), and six or more identified in 15 (4%). A positive SLN was found in 104 (29%) cases. SLN #1 was the first positive SLN in 86 (83%). SLN #2 was the first positive SLN in 15 (14%). SLN #3, SLN #4, and SLN #5 were the first positive SLN in one case (1%) each. A positive SLN was found in 18% (19/104) of cases when a single SLN was identified, as compared to in 34% (85/249) when two or more SLNs were identified (P = 0.003). Conclusion The accurate and optimal assessment of the axilla during breast cancer surgery requires persistence and diligence for attempting to identify all potential SLN candidates in order to avoid failing to recognize a positive SLN. The scenario in which only a single negative SLN candidate is intraoperatively identified is one that should raise some concern to the operating surgeon. Sentinel Lymph Node (dpeaa)DE-He213 Sentinel Lymph Node Biopsy (dpeaa)DE-He213 Invasive Breast Cancer (dpeaa)DE-He213 Axillary Lymph Node Dissection (dpeaa)DE-He213 Positive Sentinel Lymph Node (dpeaa)DE-He213 Young, Donn C aut Walker, Michael J aut Carson, William E aut Yee, Lisa D aut Agnese, Doreen M aut Farrar, William B aut Enthalten in World journal of surgical oncology London : Biomed Central, 2003 5(2007), 1 vom: 09. Feb. (DE-627)369082907 (DE-600)2118383-1 1477-7819 nnns volume:5 year:2007 number:1 day:09 month:02 https://dx.doi.org/10.1186/1477-7819-5-18 kostenfrei Volltext GBV_USEFLAG_A SYSFLAG_A GBV_SPRINGER SSG-OLC-PHA GBV_ILN_20 GBV_ILN_22 GBV_ILN_23 GBV_ILN_24 GBV_ILN_39 GBV_ILN_40 GBV_ILN_60 GBV_ILN_62 GBV_ILN_63 GBV_ILN_65 GBV_ILN_69 GBV_ILN_73 GBV_ILN_74 GBV_ILN_95 GBV_ILN_105 GBV_ILN_110 GBV_ILN_151 GBV_ILN_161 GBV_ILN_170 GBV_ILN_206 GBV_ILN_213 GBV_ILN_230 GBV_ILN_285 GBV_ILN_293 GBV_ILN_602 GBV_ILN_2014 GBV_ILN_4012 GBV_ILN_4037 GBV_ILN_4112 GBV_ILN_4125 GBV_ILN_4126 GBV_ILN_4249 GBV_ILN_4305 GBV_ILN_4306 GBV_ILN_4307 GBV_ILN_4313 GBV_ILN_4322 GBV_ILN_4323 GBV_ILN_4324 GBV_ILN_4325 GBV_ILN_4338 GBV_ILN_4367 GBV_ILN_4700 AR 5 2007 1 09 02 |
allfieldsGer |
10.1186/1477-7819-5-18 doi (DE-627)SPR028811208 (SPR)1477-7819-5-18-e DE-627 ger DE-627 rakwb eng Povoski, Stephen P verfasserin aut Re-emphasizing the concept of adequacy of intraoperative assessment of the axillary sentinel lymph nodes for identifying nodal positivity during breast cancer surgery 2007 Text txt rdacontent Computermedien c rdamedia Online-Ressource cr rdacarrier © Povoski et al; licensee BioMed Central Ltd. 2007 Background Although sentinel lymph node (SLN) biopsy is a standard of care for the evaluation of the axillary lymph nodes during breast cancer surgery, a substantial degree of variation exists among individual surgeons as to what represents an adequate assessment. The aim of the current study was to assess when metastatic disease was first identified within consecutively harvested SLN candidates for invasive breast cancers demonstrating a positive SLN. Methods We retrospectively analyzed a series of 400 breast cancers from a recently published prospective randomized clinical trial. A combined radiocolloid and blue dye technique was used. All potential SLN candidates, containing counts of at least 10% of the hottest SLN and/or containing blue dye, were harvested and were consecutively numbered in the order of the decreasing level of counts (with the hottest SLN representing SLN #1). Results Among 371 invasive breast cancers, a SLN was identified within 353 cases (95%). Mean number of SLNs identified was 2.5 (range, 1 to 9), with a single SLN identified in 104 (29%) cases, two identified in 110 (31%), three identified in 73 (21%), four identified in 35 (10%), five identified in 16 (5%), and six or more identified in 15 (4%). A positive SLN was found in 104 (29%) cases. SLN #1 was the first positive SLN in 86 (83%). SLN #2 was the first positive SLN in 15 (14%). SLN #3, SLN #4, and SLN #5 were the first positive SLN in one case (1%) each. A positive SLN was found in 18% (19/104) of cases when a single SLN was identified, as compared to in 34% (85/249) when two or more SLNs were identified (P = 0.003). Conclusion The accurate and optimal assessment of the axilla during breast cancer surgery requires persistence and diligence for attempting to identify all potential SLN candidates in order to avoid failing to recognize a positive SLN. The scenario in which only a single negative SLN candidate is intraoperatively identified is one that should raise some concern to the operating surgeon. Sentinel Lymph Node (dpeaa)DE-He213 Sentinel Lymph Node Biopsy (dpeaa)DE-He213 Invasive Breast Cancer (dpeaa)DE-He213 Axillary Lymph Node Dissection (dpeaa)DE-He213 Positive Sentinel Lymph Node (dpeaa)DE-He213 Young, Donn C aut Walker, Michael J aut Carson, William E aut Yee, Lisa D aut Agnese, Doreen M aut Farrar, William B aut Enthalten in World journal of surgical oncology London : Biomed Central, 2003 5(2007), 1 vom: 09. Feb. (DE-627)369082907 (DE-600)2118383-1 1477-7819 nnns volume:5 year:2007 number:1 day:09 month:02 https://dx.doi.org/10.1186/1477-7819-5-18 kostenfrei Volltext GBV_USEFLAG_A SYSFLAG_A GBV_SPRINGER SSG-OLC-PHA GBV_ILN_20 GBV_ILN_22 GBV_ILN_23 GBV_ILN_24 GBV_ILN_39 GBV_ILN_40 GBV_ILN_60 GBV_ILN_62 GBV_ILN_63 GBV_ILN_65 GBV_ILN_69 GBV_ILN_73 GBV_ILN_74 GBV_ILN_95 GBV_ILN_105 GBV_ILN_110 GBV_ILN_151 GBV_ILN_161 GBV_ILN_170 GBV_ILN_206 GBV_ILN_213 GBV_ILN_230 GBV_ILN_285 GBV_ILN_293 GBV_ILN_602 GBV_ILN_2014 GBV_ILN_4012 GBV_ILN_4037 GBV_ILN_4112 GBV_ILN_4125 GBV_ILN_4126 GBV_ILN_4249 GBV_ILN_4305 GBV_ILN_4306 GBV_ILN_4307 GBV_ILN_4313 GBV_ILN_4322 GBV_ILN_4323 GBV_ILN_4324 GBV_ILN_4325 GBV_ILN_4338 GBV_ILN_4367 GBV_ILN_4700 AR 5 2007 1 09 02 |
allfieldsSound |
10.1186/1477-7819-5-18 doi (DE-627)SPR028811208 (SPR)1477-7819-5-18-e DE-627 ger DE-627 rakwb eng Povoski, Stephen P verfasserin aut Re-emphasizing the concept of adequacy of intraoperative assessment of the axillary sentinel lymph nodes for identifying nodal positivity during breast cancer surgery 2007 Text txt rdacontent Computermedien c rdamedia Online-Ressource cr rdacarrier © Povoski et al; licensee BioMed Central Ltd. 2007 Background Although sentinel lymph node (SLN) biopsy is a standard of care for the evaluation of the axillary lymph nodes during breast cancer surgery, a substantial degree of variation exists among individual surgeons as to what represents an adequate assessment. The aim of the current study was to assess when metastatic disease was first identified within consecutively harvested SLN candidates for invasive breast cancers demonstrating a positive SLN. Methods We retrospectively analyzed a series of 400 breast cancers from a recently published prospective randomized clinical trial. A combined radiocolloid and blue dye technique was used. All potential SLN candidates, containing counts of at least 10% of the hottest SLN and/or containing blue dye, were harvested and were consecutively numbered in the order of the decreasing level of counts (with the hottest SLN representing SLN #1). Results Among 371 invasive breast cancers, a SLN was identified within 353 cases (95%). Mean number of SLNs identified was 2.5 (range, 1 to 9), with a single SLN identified in 104 (29%) cases, two identified in 110 (31%), three identified in 73 (21%), four identified in 35 (10%), five identified in 16 (5%), and six or more identified in 15 (4%). A positive SLN was found in 104 (29%) cases. SLN #1 was the first positive SLN in 86 (83%). SLN #2 was the first positive SLN in 15 (14%). SLN #3, SLN #4, and SLN #5 were the first positive SLN in one case (1%) each. A positive SLN was found in 18% (19/104) of cases when a single SLN was identified, as compared to in 34% (85/249) when two or more SLNs were identified (P = 0.003). Conclusion The accurate and optimal assessment of the axilla during breast cancer surgery requires persistence and diligence for attempting to identify all potential SLN candidates in order to avoid failing to recognize a positive SLN. The scenario in which only a single negative SLN candidate is intraoperatively identified is one that should raise some concern to the operating surgeon. Sentinel Lymph Node (dpeaa)DE-He213 Sentinel Lymph Node Biopsy (dpeaa)DE-He213 Invasive Breast Cancer (dpeaa)DE-He213 Axillary Lymph Node Dissection (dpeaa)DE-He213 Positive Sentinel Lymph Node (dpeaa)DE-He213 Young, Donn C aut Walker, Michael J aut Carson, William E aut Yee, Lisa D aut Agnese, Doreen M aut Farrar, William B aut Enthalten in World journal of surgical oncology London : Biomed Central, 2003 5(2007), 1 vom: 09. Feb. (DE-627)369082907 (DE-600)2118383-1 1477-7819 nnns volume:5 year:2007 number:1 day:09 month:02 https://dx.doi.org/10.1186/1477-7819-5-18 kostenfrei Volltext GBV_USEFLAG_A SYSFLAG_A GBV_SPRINGER SSG-OLC-PHA GBV_ILN_20 GBV_ILN_22 GBV_ILN_23 GBV_ILN_24 GBV_ILN_39 GBV_ILN_40 GBV_ILN_60 GBV_ILN_62 GBV_ILN_63 GBV_ILN_65 GBV_ILN_69 GBV_ILN_73 GBV_ILN_74 GBV_ILN_95 GBV_ILN_105 GBV_ILN_110 GBV_ILN_151 GBV_ILN_161 GBV_ILN_170 GBV_ILN_206 GBV_ILN_213 GBV_ILN_230 GBV_ILN_285 GBV_ILN_293 GBV_ILN_602 GBV_ILN_2014 GBV_ILN_4012 GBV_ILN_4037 GBV_ILN_4112 GBV_ILN_4125 GBV_ILN_4126 GBV_ILN_4249 GBV_ILN_4305 GBV_ILN_4306 GBV_ILN_4307 GBV_ILN_4313 GBV_ILN_4322 GBV_ILN_4323 GBV_ILN_4324 GBV_ILN_4325 GBV_ILN_4338 GBV_ILN_4367 GBV_ILN_4700 AR 5 2007 1 09 02 |
language |
English |
source |
Enthalten in World journal of surgical oncology 5(2007), 1 vom: 09. Feb. volume:5 year:2007 number:1 day:09 month:02 |
sourceStr |
Enthalten in World journal of surgical oncology 5(2007), 1 vom: 09. Feb. volume:5 year:2007 number:1 day:09 month:02 |
format_phy_str_mv |
Article |
institution |
findex.gbv.de |
topic_facet |
Sentinel Lymph Node Sentinel Lymph Node Biopsy Invasive Breast Cancer Axillary Lymph Node Dissection Positive Sentinel Lymph Node |
isfreeaccess_bool |
true |
container_title |
World journal of surgical oncology |
authorswithroles_txt_mv |
Povoski, Stephen P @@aut@@ Young, Donn C @@aut@@ Walker, Michael J @@aut@@ Carson, William E @@aut@@ Yee, Lisa D @@aut@@ Agnese, Doreen M @@aut@@ Farrar, William B @@aut@@ |
publishDateDaySort_date |
2007-02-09T00:00:00Z |
hierarchy_top_id |
369082907 |
id |
SPR028811208 |
language_de |
englisch |
fullrecord |
<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim"><record><leader>01000caa a22002652 4500</leader><controlfield tag="001">SPR028811208</controlfield><controlfield tag="003">DE-627</controlfield><controlfield tag="005">20230519150041.0</controlfield><controlfield tag="007">cr uuu---uuuuu</controlfield><controlfield tag="008">201007s2007 xx |||||o 00| ||eng c</controlfield><datafield tag="024" ind1="7" ind2=" "><subfield code="a">10.1186/1477-7819-5-18</subfield><subfield code="2">doi</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-627)SPR028811208</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(SPR)1477-7819-5-18-e</subfield></datafield><datafield tag="040" ind1=" " ind2=" "><subfield code="a">DE-627</subfield><subfield code="b">ger</subfield><subfield code="c">DE-627</subfield><subfield code="e">rakwb</subfield></datafield><datafield tag="041" ind1=" " ind2=" "><subfield code="a">eng</subfield></datafield><datafield tag="100" ind1="1" ind2=" "><subfield code="a">Povoski, Stephen P</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="245" ind1="1" ind2="0"><subfield code="a">Re-emphasizing the concept of adequacy of intraoperative assessment of the axillary sentinel lymph nodes for identifying nodal positivity during breast cancer surgery</subfield></datafield><datafield tag="264" ind1=" " ind2="1"><subfield code="c">2007</subfield></datafield><datafield tag="336" ind1=" " ind2=" "><subfield code="a">Text</subfield><subfield code="b">txt</subfield><subfield code="2">rdacontent</subfield></datafield><datafield tag="337" ind1=" " ind2=" "><subfield code="a">Computermedien</subfield><subfield code="b">c</subfield><subfield code="2">rdamedia</subfield></datafield><datafield tag="338" ind1=" " ind2=" "><subfield code="a">Online-Ressource</subfield><subfield code="b">cr</subfield><subfield code="2">rdacarrier</subfield></datafield><datafield tag="500" ind1=" " ind2=" "><subfield code="a">© Povoski et al; licensee BioMed Central Ltd. 2007</subfield></datafield><datafield tag="520" ind1=" " ind2=" "><subfield code="a">Background Although sentinel lymph node (SLN) biopsy is a standard of care for the evaluation of the axillary lymph nodes during breast cancer surgery, a substantial degree of variation exists among individual surgeons as to what represents an adequate assessment. The aim of the current study was to assess when metastatic disease was first identified within consecutively harvested SLN candidates for invasive breast cancers demonstrating a positive SLN. Methods We retrospectively analyzed a series of 400 breast cancers from a recently published prospective randomized clinical trial. A combined radiocolloid and blue dye technique was used. All potential SLN candidates, containing counts of at least 10% of the hottest SLN and/or containing blue dye, were harvested and were consecutively numbered in the order of the decreasing level of counts (with the hottest SLN representing SLN #1). Results Among 371 invasive breast cancers, a SLN was identified within 353 cases (95%). Mean number of SLNs identified was 2.5 (range, 1 to 9), with a single SLN identified in 104 (29%) cases, two identified in 110 (31%), three identified in 73 (21%), four identified in 35 (10%), five identified in 16 (5%), and six or more identified in 15 (4%). A positive SLN was found in 104 (29%) cases. SLN #1 was the first positive SLN in 86 (83%). SLN #2 was the first positive SLN in 15 (14%). SLN #3, SLN #4, and SLN #5 were the first positive SLN in one case (1%) each. A positive SLN was found in 18% (19/104) of cases when a single SLN was identified, as compared to in 34% (85/249) when two or more SLNs were identified (P = 0.003). Conclusion The accurate and optimal assessment of the axilla during breast cancer surgery requires persistence and diligence for attempting to identify all potential SLN candidates in order to avoid failing to recognize a positive SLN. The scenario in which only a single negative SLN candidate is intraoperatively identified is one that should raise some concern to the operating surgeon.</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Sentinel Lymph Node</subfield><subfield code="7">(dpeaa)DE-He213</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Sentinel Lymph Node Biopsy</subfield><subfield code="7">(dpeaa)DE-He213</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Invasive Breast Cancer</subfield><subfield code="7">(dpeaa)DE-He213</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Axillary Lymph Node Dissection</subfield><subfield code="7">(dpeaa)DE-He213</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Positive Sentinel Lymph Node</subfield><subfield code="7">(dpeaa)DE-He213</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Young, Donn C</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Walker, Michael J</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Carson, William E</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Yee, Lisa D</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Agnese, Doreen M</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Farrar, William B</subfield><subfield code="4">aut</subfield></datafield><datafield tag="773" ind1="0" ind2="8"><subfield code="i">Enthalten in</subfield><subfield code="t">World journal of surgical oncology</subfield><subfield code="d">London : Biomed Central, 2003</subfield><subfield code="g">5(2007), 1 vom: 09. Feb.</subfield><subfield code="w">(DE-627)369082907</subfield><subfield code="w">(DE-600)2118383-1</subfield><subfield code="x">1477-7819</subfield><subfield code="7">nnns</subfield></datafield><datafield tag="773" ind1="1" ind2="8"><subfield code="g">volume:5</subfield><subfield code="g">year:2007</subfield><subfield code="g">number:1</subfield><subfield code="g">day:09</subfield><subfield code="g">month:02</subfield></datafield><datafield tag="856" ind1="4" ind2="0"><subfield code="u">https://dx.doi.org/10.1186/1477-7819-5-18</subfield><subfield code="z">kostenfrei</subfield><subfield code="3">Volltext</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_USEFLAG_A</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">SYSFLAG_A</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_SPRINGER</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">SSG-OLC-PHA</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_20</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_22</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_23</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_24</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_39</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_40</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_60</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_62</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_63</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_65</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_69</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_73</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_74</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_95</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_105</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_110</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_151</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_161</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_170</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_206</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_213</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_230</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_285</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_293</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_602</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2014</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4012</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4037</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4112</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4125</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4126</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4249</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4305</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4306</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4307</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4313</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4322</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4323</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4324</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4325</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4338</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4367</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4700</subfield></datafield><datafield tag="951" ind1=" " ind2=" "><subfield code="a">AR</subfield></datafield><datafield tag="952" ind1=" " ind2=" "><subfield code="d">5</subfield><subfield code="j">2007</subfield><subfield code="e">1</subfield><subfield code="b">09</subfield><subfield code="c">02</subfield></datafield></record></collection>
|
author |
Povoski, Stephen P |
spellingShingle |
Povoski, Stephen P misc Sentinel Lymph Node misc Sentinel Lymph Node Biopsy misc Invasive Breast Cancer misc Axillary Lymph Node Dissection misc Positive Sentinel Lymph Node Re-emphasizing the concept of adequacy of intraoperative assessment of the axillary sentinel lymph nodes for identifying nodal positivity during breast cancer surgery |
authorStr |
Povoski, Stephen P |
ppnlink_with_tag_str_mv |
@@773@@(DE-627)369082907 |
format |
electronic Article |
delete_txt_mv |
keep |
author_role |
aut aut aut aut aut aut aut |
collection |
springer |
remote_str |
true |
illustrated |
Not Illustrated |
issn |
1477-7819 |
topic_title |
Re-emphasizing the concept of adequacy of intraoperative assessment of the axillary sentinel lymph nodes for identifying nodal positivity during breast cancer surgery Sentinel Lymph Node (dpeaa)DE-He213 Sentinel Lymph Node Biopsy (dpeaa)DE-He213 Invasive Breast Cancer (dpeaa)DE-He213 Axillary Lymph Node Dissection (dpeaa)DE-He213 Positive Sentinel Lymph Node (dpeaa)DE-He213 |
topic |
misc Sentinel Lymph Node misc Sentinel Lymph Node Biopsy misc Invasive Breast Cancer misc Axillary Lymph Node Dissection misc Positive Sentinel Lymph Node |
topic_unstemmed |
misc Sentinel Lymph Node misc Sentinel Lymph Node Biopsy misc Invasive Breast Cancer misc Axillary Lymph Node Dissection misc Positive Sentinel Lymph Node |
topic_browse |
misc Sentinel Lymph Node misc Sentinel Lymph Node Biopsy misc Invasive Breast Cancer misc Axillary Lymph Node Dissection misc Positive Sentinel Lymph Node |
format_facet |
Elektronische Aufsätze Aufsätze Elektronische Ressource |
format_main_str_mv |
Text Zeitschrift/Artikel |
carriertype_str_mv |
cr |
hierarchy_parent_title |
World journal of surgical oncology |
hierarchy_parent_id |
369082907 |
hierarchy_top_title |
World journal of surgical oncology |
isfreeaccess_txt |
true |
familylinks_str_mv |
(DE-627)369082907 (DE-600)2118383-1 |
title |
Re-emphasizing the concept of adequacy of intraoperative assessment of the axillary sentinel lymph nodes for identifying nodal positivity during breast cancer surgery |
ctrlnum |
(DE-627)SPR028811208 (SPR)1477-7819-5-18-e |
title_full |
Re-emphasizing the concept of adequacy of intraoperative assessment of the axillary sentinel lymph nodes for identifying nodal positivity during breast cancer surgery |
author_sort |
Povoski, Stephen P |
journal |
World journal of surgical oncology |
journalStr |
World journal of surgical oncology |
lang_code |
eng |
isOA_bool |
true |
recordtype |
marc |
publishDateSort |
2007 |
contenttype_str_mv |
txt |
author_browse |
Povoski, Stephen P Young, Donn C Walker, Michael J Carson, William E Yee, Lisa D Agnese, Doreen M Farrar, William B |
container_volume |
5 |
format_se |
Elektronische Aufsätze |
author-letter |
Povoski, Stephen P |
doi_str_mv |
10.1186/1477-7819-5-18 |
title_sort |
re-emphasizing the concept of adequacy of intraoperative assessment of the axillary sentinel lymph nodes for identifying nodal positivity during breast cancer surgery |
title_auth |
Re-emphasizing the concept of adequacy of intraoperative assessment of the axillary sentinel lymph nodes for identifying nodal positivity during breast cancer surgery |
abstract |
Background Although sentinel lymph node (SLN) biopsy is a standard of care for the evaluation of the axillary lymph nodes during breast cancer surgery, a substantial degree of variation exists among individual surgeons as to what represents an adequate assessment. The aim of the current study was to assess when metastatic disease was first identified within consecutively harvested SLN candidates for invasive breast cancers demonstrating a positive SLN. Methods We retrospectively analyzed a series of 400 breast cancers from a recently published prospective randomized clinical trial. A combined radiocolloid and blue dye technique was used. All potential SLN candidates, containing counts of at least 10% of the hottest SLN and/or containing blue dye, were harvested and were consecutively numbered in the order of the decreasing level of counts (with the hottest SLN representing SLN #1). Results Among 371 invasive breast cancers, a SLN was identified within 353 cases (95%). Mean number of SLNs identified was 2.5 (range, 1 to 9), with a single SLN identified in 104 (29%) cases, two identified in 110 (31%), three identified in 73 (21%), four identified in 35 (10%), five identified in 16 (5%), and six or more identified in 15 (4%). A positive SLN was found in 104 (29%) cases. SLN #1 was the first positive SLN in 86 (83%). SLN #2 was the first positive SLN in 15 (14%). SLN #3, SLN #4, and SLN #5 were the first positive SLN in one case (1%) each. A positive SLN was found in 18% (19/104) of cases when a single SLN was identified, as compared to in 34% (85/249) when two or more SLNs were identified (P = 0.003). Conclusion The accurate and optimal assessment of the axilla during breast cancer surgery requires persistence and diligence for attempting to identify all potential SLN candidates in order to avoid failing to recognize a positive SLN. The scenario in which only a single negative SLN candidate is intraoperatively identified is one that should raise some concern to the operating surgeon. © Povoski et al; licensee BioMed Central Ltd. 2007 |
abstractGer |
Background Although sentinel lymph node (SLN) biopsy is a standard of care for the evaluation of the axillary lymph nodes during breast cancer surgery, a substantial degree of variation exists among individual surgeons as to what represents an adequate assessment. The aim of the current study was to assess when metastatic disease was first identified within consecutively harvested SLN candidates for invasive breast cancers demonstrating a positive SLN. Methods We retrospectively analyzed a series of 400 breast cancers from a recently published prospective randomized clinical trial. A combined radiocolloid and blue dye technique was used. All potential SLN candidates, containing counts of at least 10% of the hottest SLN and/or containing blue dye, were harvested and were consecutively numbered in the order of the decreasing level of counts (with the hottest SLN representing SLN #1). Results Among 371 invasive breast cancers, a SLN was identified within 353 cases (95%). Mean number of SLNs identified was 2.5 (range, 1 to 9), with a single SLN identified in 104 (29%) cases, two identified in 110 (31%), three identified in 73 (21%), four identified in 35 (10%), five identified in 16 (5%), and six or more identified in 15 (4%). A positive SLN was found in 104 (29%) cases. SLN #1 was the first positive SLN in 86 (83%). SLN #2 was the first positive SLN in 15 (14%). SLN #3, SLN #4, and SLN #5 were the first positive SLN in one case (1%) each. A positive SLN was found in 18% (19/104) of cases when a single SLN was identified, as compared to in 34% (85/249) when two or more SLNs were identified (P = 0.003). Conclusion The accurate and optimal assessment of the axilla during breast cancer surgery requires persistence and diligence for attempting to identify all potential SLN candidates in order to avoid failing to recognize a positive SLN. The scenario in which only a single negative SLN candidate is intraoperatively identified is one that should raise some concern to the operating surgeon. © Povoski et al; licensee BioMed Central Ltd. 2007 |
abstract_unstemmed |
Background Although sentinel lymph node (SLN) biopsy is a standard of care for the evaluation of the axillary lymph nodes during breast cancer surgery, a substantial degree of variation exists among individual surgeons as to what represents an adequate assessment. The aim of the current study was to assess when metastatic disease was first identified within consecutively harvested SLN candidates for invasive breast cancers demonstrating a positive SLN. Methods We retrospectively analyzed a series of 400 breast cancers from a recently published prospective randomized clinical trial. A combined radiocolloid and blue dye technique was used. All potential SLN candidates, containing counts of at least 10% of the hottest SLN and/or containing blue dye, were harvested and were consecutively numbered in the order of the decreasing level of counts (with the hottest SLN representing SLN #1). Results Among 371 invasive breast cancers, a SLN was identified within 353 cases (95%). Mean number of SLNs identified was 2.5 (range, 1 to 9), with a single SLN identified in 104 (29%) cases, two identified in 110 (31%), three identified in 73 (21%), four identified in 35 (10%), five identified in 16 (5%), and six or more identified in 15 (4%). A positive SLN was found in 104 (29%) cases. SLN #1 was the first positive SLN in 86 (83%). SLN #2 was the first positive SLN in 15 (14%). SLN #3, SLN #4, and SLN #5 were the first positive SLN in one case (1%) each. A positive SLN was found in 18% (19/104) of cases when a single SLN was identified, as compared to in 34% (85/249) when two or more SLNs were identified (P = 0.003). Conclusion The accurate and optimal assessment of the axilla during breast cancer surgery requires persistence and diligence for attempting to identify all potential SLN candidates in order to avoid failing to recognize a positive SLN. The scenario in which only a single negative SLN candidate is intraoperatively identified is one that should raise some concern to the operating surgeon. © Povoski et al; licensee BioMed Central Ltd. 2007 |
collection_details |
GBV_USEFLAG_A SYSFLAG_A GBV_SPRINGER SSG-OLC-PHA GBV_ILN_20 GBV_ILN_22 GBV_ILN_23 GBV_ILN_24 GBV_ILN_39 GBV_ILN_40 GBV_ILN_60 GBV_ILN_62 GBV_ILN_63 GBV_ILN_65 GBV_ILN_69 GBV_ILN_73 GBV_ILN_74 GBV_ILN_95 GBV_ILN_105 GBV_ILN_110 GBV_ILN_151 GBV_ILN_161 GBV_ILN_170 GBV_ILN_206 GBV_ILN_213 GBV_ILN_230 GBV_ILN_285 GBV_ILN_293 GBV_ILN_602 GBV_ILN_2014 GBV_ILN_4012 GBV_ILN_4037 GBV_ILN_4112 GBV_ILN_4125 GBV_ILN_4126 GBV_ILN_4249 GBV_ILN_4305 GBV_ILN_4306 GBV_ILN_4307 GBV_ILN_4313 GBV_ILN_4322 GBV_ILN_4323 GBV_ILN_4324 GBV_ILN_4325 GBV_ILN_4338 GBV_ILN_4367 GBV_ILN_4700 |
container_issue |
1 |
title_short |
Re-emphasizing the concept of adequacy of intraoperative assessment of the axillary sentinel lymph nodes for identifying nodal positivity during breast cancer surgery |
url |
https://dx.doi.org/10.1186/1477-7819-5-18 |
remote_bool |
true |
author2 |
Young, Donn C Walker, Michael J Carson, William E Yee, Lisa D Agnese, Doreen M Farrar, William B |
author2Str |
Young, Donn C Walker, Michael J Carson, William E Yee, Lisa D Agnese, Doreen M Farrar, William B |
ppnlink |
369082907 |
mediatype_str_mv |
c |
isOA_txt |
true |
hochschulschrift_bool |
false |
doi_str |
10.1186/1477-7819-5-18 |
up_date |
2024-07-03T21:52:09.243Z |
_version_ |
1803596363719507968 |
fullrecord_marcxml |
<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim"><record><leader>01000caa a22002652 4500</leader><controlfield tag="001">SPR028811208</controlfield><controlfield tag="003">DE-627</controlfield><controlfield tag="005">20230519150041.0</controlfield><controlfield tag="007">cr uuu---uuuuu</controlfield><controlfield tag="008">201007s2007 xx |||||o 00| ||eng c</controlfield><datafield tag="024" ind1="7" ind2=" "><subfield code="a">10.1186/1477-7819-5-18</subfield><subfield code="2">doi</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-627)SPR028811208</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(SPR)1477-7819-5-18-e</subfield></datafield><datafield tag="040" ind1=" " ind2=" "><subfield code="a">DE-627</subfield><subfield code="b">ger</subfield><subfield code="c">DE-627</subfield><subfield code="e">rakwb</subfield></datafield><datafield tag="041" ind1=" " ind2=" "><subfield code="a">eng</subfield></datafield><datafield tag="100" ind1="1" ind2=" "><subfield code="a">Povoski, Stephen P</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="245" ind1="1" ind2="0"><subfield code="a">Re-emphasizing the concept of adequacy of intraoperative assessment of the axillary sentinel lymph nodes for identifying nodal positivity during breast cancer surgery</subfield></datafield><datafield tag="264" ind1=" " ind2="1"><subfield code="c">2007</subfield></datafield><datafield tag="336" ind1=" " ind2=" "><subfield code="a">Text</subfield><subfield code="b">txt</subfield><subfield code="2">rdacontent</subfield></datafield><datafield tag="337" ind1=" " ind2=" "><subfield code="a">Computermedien</subfield><subfield code="b">c</subfield><subfield code="2">rdamedia</subfield></datafield><datafield tag="338" ind1=" " ind2=" "><subfield code="a">Online-Ressource</subfield><subfield code="b">cr</subfield><subfield code="2">rdacarrier</subfield></datafield><datafield tag="500" ind1=" " ind2=" "><subfield code="a">© Povoski et al; licensee BioMed Central Ltd. 2007</subfield></datafield><datafield tag="520" ind1=" " ind2=" "><subfield code="a">Background Although sentinel lymph node (SLN) biopsy is a standard of care for the evaluation of the axillary lymph nodes during breast cancer surgery, a substantial degree of variation exists among individual surgeons as to what represents an adequate assessment. The aim of the current study was to assess when metastatic disease was first identified within consecutively harvested SLN candidates for invasive breast cancers demonstrating a positive SLN. Methods We retrospectively analyzed a series of 400 breast cancers from a recently published prospective randomized clinical trial. A combined radiocolloid and blue dye technique was used. All potential SLN candidates, containing counts of at least 10% of the hottest SLN and/or containing blue dye, were harvested and were consecutively numbered in the order of the decreasing level of counts (with the hottest SLN representing SLN #1). Results Among 371 invasive breast cancers, a SLN was identified within 353 cases (95%). Mean number of SLNs identified was 2.5 (range, 1 to 9), with a single SLN identified in 104 (29%) cases, two identified in 110 (31%), three identified in 73 (21%), four identified in 35 (10%), five identified in 16 (5%), and six or more identified in 15 (4%). A positive SLN was found in 104 (29%) cases. SLN #1 was the first positive SLN in 86 (83%). SLN #2 was the first positive SLN in 15 (14%). SLN #3, SLN #4, and SLN #5 were the first positive SLN in one case (1%) each. A positive SLN was found in 18% (19/104) of cases when a single SLN was identified, as compared to in 34% (85/249) when two or more SLNs were identified (P = 0.003). Conclusion The accurate and optimal assessment of the axilla during breast cancer surgery requires persistence and diligence for attempting to identify all potential SLN candidates in order to avoid failing to recognize a positive SLN. The scenario in which only a single negative SLN candidate is intraoperatively identified is one that should raise some concern to the operating surgeon.</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Sentinel Lymph Node</subfield><subfield code="7">(dpeaa)DE-He213</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Sentinel Lymph Node Biopsy</subfield><subfield code="7">(dpeaa)DE-He213</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Invasive Breast Cancer</subfield><subfield code="7">(dpeaa)DE-He213</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Axillary Lymph Node Dissection</subfield><subfield code="7">(dpeaa)DE-He213</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Positive Sentinel Lymph Node</subfield><subfield code="7">(dpeaa)DE-He213</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Young, Donn C</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Walker, Michael J</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Carson, William E</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Yee, Lisa D</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Agnese, Doreen M</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Farrar, William B</subfield><subfield code="4">aut</subfield></datafield><datafield tag="773" ind1="0" ind2="8"><subfield code="i">Enthalten in</subfield><subfield code="t">World journal of surgical oncology</subfield><subfield code="d">London : Biomed Central, 2003</subfield><subfield code="g">5(2007), 1 vom: 09. Feb.</subfield><subfield code="w">(DE-627)369082907</subfield><subfield code="w">(DE-600)2118383-1</subfield><subfield code="x">1477-7819</subfield><subfield code="7">nnns</subfield></datafield><datafield tag="773" ind1="1" ind2="8"><subfield code="g">volume:5</subfield><subfield code="g">year:2007</subfield><subfield code="g">number:1</subfield><subfield code="g">day:09</subfield><subfield code="g">month:02</subfield></datafield><datafield tag="856" ind1="4" ind2="0"><subfield code="u">https://dx.doi.org/10.1186/1477-7819-5-18</subfield><subfield code="z">kostenfrei</subfield><subfield code="3">Volltext</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_USEFLAG_A</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">SYSFLAG_A</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_SPRINGER</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">SSG-OLC-PHA</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_20</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_22</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_23</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_24</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_39</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_40</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_60</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_62</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_63</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_65</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_69</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_73</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_74</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_95</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_105</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_110</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_151</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_161</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_170</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_206</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_213</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_230</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_285</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_293</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_602</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2014</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4012</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4037</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4112</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4125</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4126</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4249</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4305</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4306</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4307</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4313</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4322</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4323</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4324</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4325</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4338</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4367</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4700</subfield></datafield><datafield tag="951" ind1=" " ind2=" "><subfield code="a">AR</subfield></datafield><datafield tag="952" ind1=" " ind2=" "><subfield code="d">5</subfield><subfield code="j">2007</subfield><subfield code="e">1</subfield><subfield code="b">09</subfield><subfield code="c">02</subfield></datafield></record></collection>
|
score |
7.401991 |