Stability-Indicating Densitometric HPTLC Method for Qualitative and Quantitative Analysis of Arbutin in Commercial Whitening Creams
Summary High-performance thin-layer chromatographic (HPTLC) densitometric method for analysis of arbutin in commercial whitening creams was developed and validated. Aluminum-backed silica gel 60 $ F_{254} $ plates were used as stationary phase while methanol-chloroform-acetic acid 3.5:6:0.5 (%, v/v/...
Ausführliche Beschreibung
Autor*in: |
Alqasoumi, Saleh I. [verfasserIn] Alam, Prawez [verfasserIn] Abdel-Kader, Maged S. [verfasserIn] |
---|
Format: |
E-Artikel |
---|---|
Sprache: |
Englisch |
Erschienen: |
2012 |
---|
Übergeordnetes Werk: |
Enthalten in: Journal of planar chromatography, modern TLC - Budapest : Akadémiai Kiadó, 2001, 25(2012), 2 vom: 01. Apr., Seite 168-173 |
---|---|
Übergeordnetes Werk: |
volume:25 ; year:2012 ; number:2 ; day:01 ; month:04 ; pages:168-173 |
Links: |
---|
DOI / URN: |
10.1556/JPC.25.2012.2.14 |
---|
Katalog-ID: |
SPR039175022 |
---|
LEADER | 01000caa a22002652 4500 | ||
---|---|---|---|
001 | SPR039175022 | ||
003 | DE-627 | ||
005 | 20230519195121.0 | ||
007 | cr uuu---uuuuu | ||
008 | 201007s2012 xx |||||o 00| ||eng c | ||
024 | 7 | |a 10.1556/JPC.25.2012.2.14 |2 doi | |
035 | |a (DE-627)SPR039175022 | ||
035 | |a (SPR)JPC.25.2012.2.14-e | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
082 | 0 | 4 | |a 540 |a 530 |q ASE |
100 | 1 | |a Alqasoumi, Saleh I. |e verfasserin |4 aut | |
245 | 1 | 0 | |a Stability-Indicating Densitometric HPTLC Method for Qualitative and Quantitative Analysis of Arbutin in Commercial Whitening Creams |
264 | 1 | |c 2012 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a Computermedien |b c |2 rdamedia | ||
338 | |a Online-Ressource |b cr |2 rdacarrier | ||
520 | |a Summary High-performance thin-layer chromatographic (HPTLC) densitometric method for analysis of arbutin in commercial whitening creams was developed and validated. Aluminum-backed silica gel 60 $ F_{254} $ plates were used as stationary phase while methanol-chloroform-acetic acid 3.5:6:0.5 (%, v/v/v) mixture was used as mobile phase. Under these chromatographic conditions, arbutin was well separated from other ingredients. This system was found to give a well defined, sharp, and compact spot of arbutin at retention factor (RF) value of 0.40 ± 0.02. The limit of detection (LOD) and limit of quantification (LOQ) were found to be 42.25 and 112.45 ng per spot respectively. The proposed method with high degree of precision and accuracy was employed for the analysis of arbutin both qualitatively and quantitatively in commercial whitening creams. Due to the efficiency of the method in separating arbutin from other ingredients including its degradation products, it can be applied as a stability-indicating method. | ||
700 | 1 | |a Alam, Prawez |e verfasserin |4 aut | |
700 | 1 | |a Abdel-Kader, Maged S. |e verfasserin |4 aut | |
773 | 0 | 8 | |i Enthalten in |t Journal of planar chromatography, modern TLC |d Budapest : Akadémiai Kiadó, 2001 |g 25(2012), 2 vom: 01. Apr., Seite 168-173 |w (DE-627)529764563 |w (DE-600)2304198-5 |x 1789-0993 |7 nnns |
773 | 1 | 8 | |g volume:25 |g year:2012 |g number:2 |g day:01 |g month:04 |g pages:168-173 |
856 | 4 | 0 | |u https://dx.doi.org/10.1556/JPC.25.2012.2.14 |z lizenzpflichtig |3 Volltext |
912 | |a GBV_USEFLAG_A | ||
912 | |a SYSFLAG_A | ||
912 | |a GBV_SPRINGER | ||
912 | |a SSG-OLC-PHA | ||
912 | |a GBV_ILN_31 | ||
912 | |a GBV_ILN_702 | ||
912 | |a GBV_ILN_2129 | ||
912 | |a GBV_ILN_2190 | ||
912 | |a GBV_ILN_4012 | ||
951 | |a AR | ||
952 | |d 25 |j 2012 |e 2 |b 01 |c 04 |h 168-173 |
author_variant |
s i a si sia p a pa m s a k msa msak |
---|---|
matchkey_str |
article:17890993:2012----::tbltidctndnioercplmtofrulttvaduniaienlssfru |
hierarchy_sort_str |
2012 |
publishDate |
2012 |
allfields |
10.1556/JPC.25.2012.2.14 doi (DE-627)SPR039175022 (SPR)JPC.25.2012.2.14-e DE-627 ger DE-627 rakwb eng 540 530 ASE Alqasoumi, Saleh I. verfasserin aut Stability-Indicating Densitometric HPTLC Method for Qualitative and Quantitative Analysis of Arbutin in Commercial Whitening Creams 2012 Text txt rdacontent Computermedien c rdamedia Online-Ressource cr rdacarrier Summary High-performance thin-layer chromatographic (HPTLC) densitometric method for analysis of arbutin in commercial whitening creams was developed and validated. Aluminum-backed silica gel 60 $ F_{254} $ plates were used as stationary phase while methanol-chloroform-acetic acid 3.5:6:0.5 (%, v/v/v) mixture was used as mobile phase. Under these chromatographic conditions, arbutin was well separated from other ingredients. This system was found to give a well defined, sharp, and compact spot of arbutin at retention factor (RF) value of 0.40 ± 0.02. The limit of detection (LOD) and limit of quantification (LOQ) were found to be 42.25 and 112.45 ng per spot respectively. The proposed method with high degree of precision and accuracy was employed for the analysis of arbutin both qualitatively and quantitatively in commercial whitening creams. Due to the efficiency of the method in separating arbutin from other ingredients including its degradation products, it can be applied as a stability-indicating method. Alam, Prawez verfasserin aut Abdel-Kader, Maged S. verfasserin aut Enthalten in Journal of planar chromatography, modern TLC Budapest : Akadémiai Kiadó, 2001 25(2012), 2 vom: 01. Apr., Seite 168-173 (DE-627)529764563 (DE-600)2304198-5 1789-0993 nnns volume:25 year:2012 number:2 day:01 month:04 pages:168-173 https://dx.doi.org/10.1556/JPC.25.2012.2.14 lizenzpflichtig Volltext GBV_USEFLAG_A SYSFLAG_A GBV_SPRINGER SSG-OLC-PHA GBV_ILN_31 GBV_ILN_702 GBV_ILN_2129 GBV_ILN_2190 GBV_ILN_4012 AR 25 2012 2 01 04 168-173 |
spelling |
10.1556/JPC.25.2012.2.14 doi (DE-627)SPR039175022 (SPR)JPC.25.2012.2.14-e DE-627 ger DE-627 rakwb eng 540 530 ASE Alqasoumi, Saleh I. verfasserin aut Stability-Indicating Densitometric HPTLC Method for Qualitative and Quantitative Analysis of Arbutin in Commercial Whitening Creams 2012 Text txt rdacontent Computermedien c rdamedia Online-Ressource cr rdacarrier Summary High-performance thin-layer chromatographic (HPTLC) densitometric method for analysis of arbutin in commercial whitening creams was developed and validated. Aluminum-backed silica gel 60 $ F_{254} $ plates were used as stationary phase while methanol-chloroform-acetic acid 3.5:6:0.5 (%, v/v/v) mixture was used as mobile phase. Under these chromatographic conditions, arbutin was well separated from other ingredients. This system was found to give a well defined, sharp, and compact spot of arbutin at retention factor (RF) value of 0.40 ± 0.02. The limit of detection (LOD) and limit of quantification (LOQ) were found to be 42.25 and 112.45 ng per spot respectively. The proposed method with high degree of precision and accuracy was employed for the analysis of arbutin both qualitatively and quantitatively in commercial whitening creams. Due to the efficiency of the method in separating arbutin from other ingredients including its degradation products, it can be applied as a stability-indicating method. Alam, Prawez verfasserin aut Abdel-Kader, Maged S. verfasserin aut Enthalten in Journal of planar chromatography, modern TLC Budapest : Akadémiai Kiadó, 2001 25(2012), 2 vom: 01. Apr., Seite 168-173 (DE-627)529764563 (DE-600)2304198-5 1789-0993 nnns volume:25 year:2012 number:2 day:01 month:04 pages:168-173 https://dx.doi.org/10.1556/JPC.25.2012.2.14 lizenzpflichtig Volltext GBV_USEFLAG_A SYSFLAG_A GBV_SPRINGER SSG-OLC-PHA GBV_ILN_31 GBV_ILN_702 GBV_ILN_2129 GBV_ILN_2190 GBV_ILN_4012 AR 25 2012 2 01 04 168-173 |
allfields_unstemmed |
10.1556/JPC.25.2012.2.14 doi (DE-627)SPR039175022 (SPR)JPC.25.2012.2.14-e DE-627 ger DE-627 rakwb eng 540 530 ASE Alqasoumi, Saleh I. verfasserin aut Stability-Indicating Densitometric HPTLC Method for Qualitative and Quantitative Analysis of Arbutin in Commercial Whitening Creams 2012 Text txt rdacontent Computermedien c rdamedia Online-Ressource cr rdacarrier Summary High-performance thin-layer chromatographic (HPTLC) densitometric method for analysis of arbutin in commercial whitening creams was developed and validated. Aluminum-backed silica gel 60 $ F_{254} $ plates were used as stationary phase while methanol-chloroform-acetic acid 3.5:6:0.5 (%, v/v/v) mixture was used as mobile phase. Under these chromatographic conditions, arbutin was well separated from other ingredients. This system was found to give a well defined, sharp, and compact spot of arbutin at retention factor (RF) value of 0.40 ± 0.02. The limit of detection (LOD) and limit of quantification (LOQ) were found to be 42.25 and 112.45 ng per spot respectively. The proposed method with high degree of precision and accuracy was employed for the analysis of arbutin both qualitatively and quantitatively in commercial whitening creams. Due to the efficiency of the method in separating arbutin from other ingredients including its degradation products, it can be applied as a stability-indicating method. Alam, Prawez verfasserin aut Abdel-Kader, Maged S. verfasserin aut Enthalten in Journal of planar chromatography, modern TLC Budapest : Akadémiai Kiadó, 2001 25(2012), 2 vom: 01. Apr., Seite 168-173 (DE-627)529764563 (DE-600)2304198-5 1789-0993 nnns volume:25 year:2012 number:2 day:01 month:04 pages:168-173 https://dx.doi.org/10.1556/JPC.25.2012.2.14 lizenzpflichtig Volltext GBV_USEFLAG_A SYSFLAG_A GBV_SPRINGER SSG-OLC-PHA GBV_ILN_31 GBV_ILN_702 GBV_ILN_2129 GBV_ILN_2190 GBV_ILN_4012 AR 25 2012 2 01 04 168-173 |
allfieldsGer |
10.1556/JPC.25.2012.2.14 doi (DE-627)SPR039175022 (SPR)JPC.25.2012.2.14-e DE-627 ger DE-627 rakwb eng 540 530 ASE Alqasoumi, Saleh I. verfasserin aut Stability-Indicating Densitometric HPTLC Method for Qualitative and Quantitative Analysis of Arbutin in Commercial Whitening Creams 2012 Text txt rdacontent Computermedien c rdamedia Online-Ressource cr rdacarrier Summary High-performance thin-layer chromatographic (HPTLC) densitometric method for analysis of arbutin in commercial whitening creams was developed and validated. Aluminum-backed silica gel 60 $ F_{254} $ plates were used as stationary phase while methanol-chloroform-acetic acid 3.5:6:0.5 (%, v/v/v) mixture was used as mobile phase. Under these chromatographic conditions, arbutin was well separated from other ingredients. This system was found to give a well defined, sharp, and compact spot of arbutin at retention factor (RF) value of 0.40 ± 0.02. The limit of detection (LOD) and limit of quantification (LOQ) were found to be 42.25 and 112.45 ng per spot respectively. The proposed method with high degree of precision and accuracy was employed for the analysis of arbutin both qualitatively and quantitatively in commercial whitening creams. Due to the efficiency of the method in separating arbutin from other ingredients including its degradation products, it can be applied as a stability-indicating method. Alam, Prawez verfasserin aut Abdel-Kader, Maged S. verfasserin aut Enthalten in Journal of planar chromatography, modern TLC Budapest : Akadémiai Kiadó, 2001 25(2012), 2 vom: 01. Apr., Seite 168-173 (DE-627)529764563 (DE-600)2304198-5 1789-0993 nnns volume:25 year:2012 number:2 day:01 month:04 pages:168-173 https://dx.doi.org/10.1556/JPC.25.2012.2.14 lizenzpflichtig Volltext GBV_USEFLAG_A SYSFLAG_A GBV_SPRINGER SSG-OLC-PHA GBV_ILN_31 GBV_ILN_702 GBV_ILN_2129 GBV_ILN_2190 GBV_ILN_4012 AR 25 2012 2 01 04 168-173 |
allfieldsSound |
10.1556/JPC.25.2012.2.14 doi (DE-627)SPR039175022 (SPR)JPC.25.2012.2.14-e DE-627 ger DE-627 rakwb eng 540 530 ASE Alqasoumi, Saleh I. verfasserin aut Stability-Indicating Densitometric HPTLC Method for Qualitative and Quantitative Analysis of Arbutin in Commercial Whitening Creams 2012 Text txt rdacontent Computermedien c rdamedia Online-Ressource cr rdacarrier Summary High-performance thin-layer chromatographic (HPTLC) densitometric method for analysis of arbutin in commercial whitening creams was developed and validated. Aluminum-backed silica gel 60 $ F_{254} $ plates were used as stationary phase while methanol-chloroform-acetic acid 3.5:6:0.5 (%, v/v/v) mixture was used as mobile phase. Under these chromatographic conditions, arbutin was well separated from other ingredients. This system was found to give a well defined, sharp, and compact spot of arbutin at retention factor (RF) value of 0.40 ± 0.02. The limit of detection (LOD) and limit of quantification (LOQ) were found to be 42.25 and 112.45 ng per spot respectively. The proposed method with high degree of precision and accuracy was employed for the analysis of arbutin both qualitatively and quantitatively in commercial whitening creams. Due to the efficiency of the method in separating arbutin from other ingredients including its degradation products, it can be applied as a stability-indicating method. Alam, Prawez verfasserin aut Abdel-Kader, Maged S. verfasserin aut Enthalten in Journal of planar chromatography, modern TLC Budapest : Akadémiai Kiadó, 2001 25(2012), 2 vom: 01. Apr., Seite 168-173 (DE-627)529764563 (DE-600)2304198-5 1789-0993 nnns volume:25 year:2012 number:2 day:01 month:04 pages:168-173 https://dx.doi.org/10.1556/JPC.25.2012.2.14 lizenzpflichtig Volltext GBV_USEFLAG_A SYSFLAG_A GBV_SPRINGER SSG-OLC-PHA GBV_ILN_31 GBV_ILN_702 GBV_ILN_2129 GBV_ILN_2190 GBV_ILN_4012 AR 25 2012 2 01 04 168-173 |
language |
English |
source |
Enthalten in Journal of planar chromatography, modern TLC 25(2012), 2 vom: 01. Apr., Seite 168-173 volume:25 year:2012 number:2 day:01 month:04 pages:168-173 |
sourceStr |
Enthalten in Journal of planar chromatography, modern TLC 25(2012), 2 vom: 01. Apr., Seite 168-173 volume:25 year:2012 number:2 day:01 month:04 pages:168-173 |
format_phy_str_mv |
Article |
institution |
findex.gbv.de |
dewey-raw |
540 |
isfreeaccess_bool |
false |
container_title |
Journal of planar chromatography, modern TLC |
authorswithroles_txt_mv |
Alqasoumi, Saleh I. @@aut@@ Alam, Prawez @@aut@@ Abdel-Kader, Maged S. @@aut@@ |
publishDateDaySort_date |
2012-04-01T00:00:00Z |
hierarchy_top_id |
529764563 |
dewey-sort |
3540 |
id |
SPR039175022 |
language_de |
englisch |
fullrecord |
<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim"><record><leader>01000caa a22002652 4500</leader><controlfield tag="001">SPR039175022</controlfield><controlfield tag="003">DE-627</controlfield><controlfield tag="005">20230519195121.0</controlfield><controlfield tag="007">cr uuu---uuuuu</controlfield><controlfield tag="008">201007s2012 xx |||||o 00| ||eng c</controlfield><datafield tag="024" ind1="7" ind2=" "><subfield code="a">10.1556/JPC.25.2012.2.14</subfield><subfield code="2">doi</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-627)SPR039175022</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(SPR)JPC.25.2012.2.14-e</subfield></datafield><datafield tag="040" ind1=" " ind2=" "><subfield code="a">DE-627</subfield><subfield code="b">ger</subfield><subfield code="c">DE-627</subfield><subfield code="e">rakwb</subfield></datafield><datafield tag="041" ind1=" " ind2=" "><subfield code="a">eng</subfield></datafield><datafield tag="082" ind1="0" ind2="4"><subfield code="a">540</subfield><subfield code="a">530</subfield><subfield code="q">ASE</subfield></datafield><datafield tag="100" ind1="1" ind2=" "><subfield code="a">Alqasoumi, Saleh I.</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="245" ind1="1" ind2="0"><subfield code="a">Stability-Indicating Densitometric HPTLC Method for Qualitative and Quantitative Analysis of Arbutin in Commercial Whitening Creams</subfield></datafield><datafield tag="264" ind1=" " ind2="1"><subfield code="c">2012</subfield></datafield><datafield tag="336" ind1=" " ind2=" "><subfield code="a">Text</subfield><subfield code="b">txt</subfield><subfield code="2">rdacontent</subfield></datafield><datafield tag="337" ind1=" " ind2=" "><subfield code="a">Computermedien</subfield><subfield code="b">c</subfield><subfield code="2">rdamedia</subfield></datafield><datafield tag="338" ind1=" " ind2=" "><subfield code="a">Online-Ressource</subfield><subfield code="b">cr</subfield><subfield code="2">rdacarrier</subfield></datafield><datafield tag="520" ind1=" " ind2=" "><subfield code="a">Summary High-performance thin-layer chromatographic (HPTLC) densitometric method for analysis of arbutin in commercial whitening creams was developed and validated. Aluminum-backed silica gel 60 $ F_{254} $ plates were used as stationary phase while methanol-chloroform-acetic acid 3.5:6:0.5 (%, v/v/v) mixture was used as mobile phase. Under these chromatographic conditions, arbutin was well separated from other ingredients. This system was found to give a well defined, sharp, and compact spot of arbutin at retention factor (RF) value of 0.40 ± 0.02. The limit of detection (LOD) and limit of quantification (LOQ) were found to be 42.25 and 112.45 ng per spot respectively. The proposed method with high degree of precision and accuracy was employed for the analysis of arbutin both qualitatively and quantitatively in commercial whitening creams. Due to the efficiency of the method in separating arbutin from other ingredients including its degradation products, it can be applied as a stability-indicating method.</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Alam, Prawez</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Abdel-Kader, Maged S.</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="773" ind1="0" ind2="8"><subfield code="i">Enthalten in</subfield><subfield code="t">Journal of planar chromatography, modern TLC</subfield><subfield code="d">Budapest : Akadémiai Kiadó, 2001</subfield><subfield code="g">25(2012), 2 vom: 01. Apr., Seite 168-173</subfield><subfield code="w">(DE-627)529764563</subfield><subfield code="w">(DE-600)2304198-5</subfield><subfield code="x">1789-0993</subfield><subfield code="7">nnns</subfield></datafield><datafield tag="773" ind1="1" ind2="8"><subfield code="g">volume:25</subfield><subfield code="g">year:2012</subfield><subfield code="g">number:2</subfield><subfield code="g">day:01</subfield><subfield code="g">month:04</subfield><subfield code="g">pages:168-173</subfield></datafield><datafield tag="856" ind1="4" ind2="0"><subfield code="u">https://dx.doi.org/10.1556/JPC.25.2012.2.14</subfield><subfield code="z">lizenzpflichtig</subfield><subfield code="3">Volltext</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_USEFLAG_A</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">SYSFLAG_A</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_SPRINGER</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">SSG-OLC-PHA</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_31</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_702</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2129</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2190</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4012</subfield></datafield><datafield tag="951" ind1=" " ind2=" "><subfield code="a">AR</subfield></datafield><datafield tag="952" ind1=" " ind2=" "><subfield code="d">25</subfield><subfield code="j">2012</subfield><subfield code="e">2</subfield><subfield code="b">01</subfield><subfield code="c">04</subfield><subfield code="h">168-173</subfield></datafield></record></collection>
|
author |
Alqasoumi, Saleh I. |
spellingShingle |
Alqasoumi, Saleh I. ddc 540 Stability-Indicating Densitometric HPTLC Method for Qualitative and Quantitative Analysis of Arbutin in Commercial Whitening Creams |
authorStr |
Alqasoumi, Saleh I. |
ppnlink_with_tag_str_mv |
@@773@@(DE-627)529764563 |
format |
electronic Article |
dewey-ones |
540 - Chemistry & allied sciences 530 - Physics |
delete_txt_mv |
keep |
author_role |
aut aut aut |
collection |
springer |
remote_str |
true |
illustrated |
Not Illustrated |
issn |
1789-0993 |
topic_title |
540 530 ASE Stability-Indicating Densitometric HPTLC Method for Qualitative and Quantitative Analysis of Arbutin in Commercial Whitening Creams |
topic |
ddc 540 |
topic_unstemmed |
ddc 540 |
topic_browse |
ddc 540 |
format_facet |
Elektronische Aufsätze Aufsätze Elektronische Ressource |
format_main_str_mv |
Text Zeitschrift/Artikel |
carriertype_str_mv |
cr |
hierarchy_parent_title |
Journal of planar chromatography, modern TLC |
hierarchy_parent_id |
529764563 |
dewey-tens |
540 - Chemistry 530 - Physics |
hierarchy_top_title |
Journal of planar chromatography, modern TLC |
isfreeaccess_txt |
false |
familylinks_str_mv |
(DE-627)529764563 (DE-600)2304198-5 |
title |
Stability-Indicating Densitometric HPTLC Method for Qualitative and Quantitative Analysis of Arbutin in Commercial Whitening Creams |
ctrlnum |
(DE-627)SPR039175022 (SPR)JPC.25.2012.2.14-e |
title_full |
Stability-Indicating Densitometric HPTLC Method for Qualitative and Quantitative Analysis of Arbutin in Commercial Whitening Creams |
author_sort |
Alqasoumi, Saleh I. |
journal |
Journal of planar chromatography, modern TLC |
journalStr |
Journal of planar chromatography, modern TLC |
lang_code |
eng |
isOA_bool |
false |
dewey-hundreds |
500 - Science |
recordtype |
marc |
publishDateSort |
2012 |
contenttype_str_mv |
txt |
container_start_page |
168 |
author_browse |
Alqasoumi, Saleh I. Alam, Prawez Abdel-Kader, Maged S. |
container_volume |
25 |
class |
540 530 ASE |
format_se |
Elektronische Aufsätze |
author-letter |
Alqasoumi, Saleh I. |
doi_str_mv |
10.1556/JPC.25.2012.2.14 |
dewey-full |
540 530 |
author2-role |
verfasserin |
title_sort |
stability-indicating densitometric hptlc method for qualitative and quantitative analysis of arbutin in commercial whitening creams |
title_auth |
Stability-Indicating Densitometric HPTLC Method for Qualitative and Quantitative Analysis of Arbutin in Commercial Whitening Creams |
abstract |
Summary High-performance thin-layer chromatographic (HPTLC) densitometric method for analysis of arbutin in commercial whitening creams was developed and validated. Aluminum-backed silica gel 60 $ F_{254} $ plates were used as stationary phase while methanol-chloroform-acetic acid 3.5:6:0.5 (%, v/v/v) mixture was used as mobile phase. Under these chromatographic conditions, arbutin was well separated from other ingredients. This system was found to give a well defined, sharp, and compact spot of arbutin at retention factor (RF) value of 0.40 ± 0.02. The limit of detection (LOD) and limit of quantification (LOQ) were found to be 42.25 and 112.45 ng per spot respectively. The proposed method with high degree of precision and accuracy was employed for the analysis of arbutin both qualitatively and quantitatively in commercial whitening creams. Due to the efficiency of the method in separating arbutin from other ingredients including its degradation products, it can be applied as a stability-indicating method. |
abstractGer |
Summary High-performance thin-layer chromatographic (HPTLC) densitometric method for analysis of arbutin in commercial whitening creams was developed and validated. Aluminum-backed silica gel 60 $ F_{254} $ plates were used as stationary phase while methanol-chloroform-acetic acid 3.5:6:0.5 (%, v/v/v) mixture was used as mobile phase. Under these chromatographic conditions, arbutin was well separated from other ingredients. This system was found to give a well defined, sharp, and compact spot of arbutin at retention factor (RF) value of 0.40 ± 0.02. The limit of detection (LOD) and limit of quantification (LOQ) were found to be 42.25 and 112.45 ng per spot respectively. The proposed method with high degree of precision and accuracy was employed for the analysis of arbutin both qualitatively and quantitatively in commercial whitening creams. Due to the efficiency of the method in separating arbutin from other ingredients including its degradation products, it can be applied as a stability-indicating method. |
abstract_unstemmed |
Summary High-performance thin-layer chromatographic (HPTLC) densitometric method for analysis of arbutin in commercial whitening creams was developed and validated. Aluminum-backed silica gel 60 $ F_{254} $ plates were used as stationary phase while methanol-chloroform-acetic acid 3.5:6:0.5 (%, v/v/v) mixture was used as mobile phase. Under these chromatographic conditions, arbutin was well separated from other ingredients. This system was found to give a well defined, sharp, and compact spot of arbutin at retention factor (RF) value of 0.40 ± 0.02. The limit of detection (LOD) and limit of quantification (LOQ) were found to be 42.25 and 112.45 ng per spot respectively. The proposed method with high degree of precision and accuracy was employed for the analysis of arbutin both qualitatively and quantitatively in commercial whitening creams. Due to the efficiency of the method in separating arbutin from other ingredients including its degradation products, it can be applied as a stability-indicating method. |
collection_details |
GBV_USEFLAG_A SYSFLAG_A GBV_SPRINGER SSG-OLC-PHA GBV_ILN_31 GBV_ILN_702 GBV_ILN_2129 GBV_ILN_2190 GBV_ILN_4012 |
container_issue |
2 |
title_short |
Stability-Indicating Densitometric HPTLC Method for Qualitative and Quantitative Analysis of Arbutin in Commercial Whitening Creams |
url |
https://dx.doi.org/10.1556/JPC.25.2012.2.14 |
remote_bool |
true |
author2 |
Alam, Prawez Abdel-Kader, Maged S. |
author2Str |
Alam, Prawez Abdel-Kader, Maged S. |
ppnlink |
529764563 |
mediatype_str_mv |
c |
isOA_txt |
false |
hochschulschrift_bool |
false |
doi_str |
10.1556/JPC.25.2012.2.14 |
up_date |
2024-07-03T22:28:55.573Z |
_version_ |
1803598677226291200 |
fullrecord_marcxml |
<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim"><record><leader>01000caa a22002652 4500</leader><controlfield tag="001">SPR039175022</controlfield><controlfield tag="003">DE-627</controlfield><controlfield tag="005">20230519195121.0</controlfield><controlfield tag="007">cr uuu---uuuuu</controlfield><controlfield tag="008">201007s2012 xx |||||o 00| ||eng c</controlfield><datafield tag="024" ind1="7" ind2=" "><subfield code="a">10.1556/JPC.25.2012.2.14</subfield><subfield code="2">doi</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-627)SPR039175022</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(SPR)JPC.25.2012.2.14-e</subfield></datafield><datafield tag="040" ind1=" " ind2=" "><subfield code="a">DE-627</subfield><subfield code="b">ger</subfield><subfield code="c">DE-627</subfield><subfield code="e">rakwb</subfield></datafield><datafield tag="041" ind1=" " ind2=" "><subfield code="a">eng</subfield></datafield><datafield tag="082" ind1="0" ind2="4"><subfield code="a">540</subfield><subfield code="a">530</subfield><subfield code="q">ASE</subfield></datafield><datafield tag="100" ind1="1" ind2=" "><subfield code="a">Alqasoumi, Saleh I.</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="245" ind1="1" ind2="0"><subfield code="a">Stability-Indicating Densitometric HPTLC Method for Qualitative and Quantitative Analysis of Arbutin in Commercial Whitening Creams</subfield></datafield><datafield tag="264" ind1=" " ind2="1"><subfield code="c">2012</subfield></datafield><datafield tag="336" ind1=" " ind2=" "><subfield code="a">Text</subfield><subfield code="b">txt</subfield><subfield code="2">rdacontent</subfield></datafield><datafield tag="337" ind1=" " ind2=" "><subfield code="a">Computermedien</subfield><subfield code="b">c</subfield><subfield code="2">rdamedia</subfield></datafield><datafield tag="338" ind1=" " ind2=" "><subfield code="a">Online-Ressource</subfield><subfield code="b">cr</subfield><subfield code="2">rdacarrier</subfield></datafield><datafield tag="520" ind1=" " ind2=" "><subfield code="a">Summary High-performance thin-layer chromatographic (HPTLC) densitometric method for analysis of arbutin in commercial whitening creams was developed and validated. Aluminum-backed silica gel 60 $ F_{254} $ plates were used as stationary phase while methanol-chloroform-acetic acid 3.5:6:0.5 (%, v/v/v) mixture was used as mobile phase. Under these chromatographic conditions, arbutin was well separated from other ingredients. This system was found to give a well defined, sharp, and compact spot of arbutin at retention factor (RF) value of 0.40 ± 0.02. The limit of detection (LOD) and limit of quantification (LOQ) were found to be 42.25 and 112.45 ng per spot respectively. The proposed method with high degree of precision and accuracy was employed for the analysis of arbutin both qualitatively and quantitatively in commercial whitening creams. Due to the efficiency of the method in separating arbutin from other ingredients including its degradation products, it can be applied as a stability-indicating method.</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Alam, Prawez</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Abdel-Kader, Maged S.</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="773" ind1="0" ind2="8"><subfield code="i">Enthalten in</subfield><subfield code="t">Journal of planar chromatography, modern TLC</subfield><subfield code="d">Budapest : Akadémiai Kiadó, 2001</subfield><subfield code="g">25(2012), 2 vom: 01. Apr., Seite 168-173</subfield><subfield code="w">(DE-627)529764563</subfield><subfield code="w">(DE-600)2304198-5</subfield><subfield code="x">1789-0993</subfield><subfield code="7">nnns</subfield></datafield><datafield tag="773" ind1="1" ind2="8"><subfield code="g">volume:25</subfield><subfield code="g">year:2012</subfield><subfield code="g">number:2</subfield><subfield code="g">day:01</subfield><subfield code="g">month:04</subfield><subfield code="g">pages:168-173</subfield></datafield><datafield tag="856" ind1="4" ind2="0"><subfield code="u">https://dx.doi.org/10.1556/JPC.25.2012.2.14</subfield><subfield code="z">lizenzpflichtig</subfield><subfield code="3">Volltext</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_USEFLAG_A</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">SYSFLAG_A</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_SPRINGER</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">SSG-OLC-PHA</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_31</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_702</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2129</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2190</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4012</subfield></datafield><datafield tag="951" ind1=" " ind2=" "><subfield code="a">AR</subfield></datafield><datafield tag="952" ind1=" " ind2=" "><subfield code="d">25</subfield><subfield code="j">2012</subfield><subfield code="e">2</subfield><subfield code="b">01</subfield><subfield code="c">04</subfield><subfield code="h">168-173</subfield></datafield></record></collection>
|
score |
7.401518 |