Digital Technology Combined with 3D Printing to Evaluate the Matching Performance of AO Clavicular Hook Plates
Background AO clavicular hook plates have been widely used for treating acromioclavicular (AC) joint dislocation and distal clavicle fractures. Many complications have been reported, and many patients have complained about the discomfort of the plate. However, no study on the impact of clavicular ho...
Ausführliche Beschreibung
Autor*in: |
Wu, Xuhua [verfasserIn] Wang, Gang [verfasserIn] Xia, Qingquan [verfasserIn] Rong, Ke [verfasserIn] Gan, Minfeng [verfasserIn] Wen, Gen [verfasserIn] Yin, Xiaofan [verfasserIn] Yang, Huilin [verfasserIn] |
---|
Format: |
E-Artikel |
---|---|
Sprache: |
Englisch |
Erschienen: |
2020 |
---|
Schlagwörter: |
---|
Übergeordnetes Werk: |
Enthalten in: Indian journal of orthopaedics - Varanasi : Assoc., 2004, 54(2020), 2 vom: 24. Jan., Seite 141-147 |
---|---|
Übergeordnetes Werk: |
volume:54 ; year:2020 ; number:2 ; day:24 ; month:01 ; pages:141-147 |
Links: |
---|
DOI / URN: |
10.1007/s43465-019-00034-0 |
---|
Katalog-ID: |
SPR03921379X |
---|
LEADER | 01000caa a22002652 4500 | ||
---|---|---|---|
001 | SPR03921379X | ||
003 | DE-627 | ||
005 | 20230519073242.0 | ||
007 | cr uuu---uuuuu | ||
008 | 201007s2020 xx |||||o 00| ||eng c | ||
024 | 7 | |a 10.1007/s43465-019-00034-0 |2 doi | |
035 | |a (DE-627)SPR03921379X | ||
035 | |a (SPR)s43465-019-00034-0-e | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
082 | 0 | 4 | |a 610 |q ASE |
100 | 1 | |a Wu, Xuhua |e verfasserin |4 aut | |
245 | 1 | 0 | |a Digital Technology Combined with 3D Printing to Evaluate the Matching Performance of AO Clavicular Hook Plates |
264 | 1 | |c 2020 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a Computermedien |b c |2 rdamedia | ||
338 | |a Online-Ressource |b cr |2 rdacarrier | ||
520 | |a Background AO clavicular hook plates have been widely used for treating acromioclavicular (AC) joint dislocation and distal clavicle fractures. Many complications have been reported, and many patients have complained about the discomfort of the plate. However, no study on the impact of clavicular hook plates in AC joint 3D printing models has been reported. Objective To evaluate the matching performance of hook plates with different hook depths when they were implanted in 3D printing models of normal Chinese AC joints and to propose a further design to achieve a better match. Methods AO clavicular hook plates with two different hook depths of 15 mm and 18 mm were implanted in 3D printing models of forty Chinese normal AC joints. The angle between the distal clavicle and plate (CPA) and the drop between acromion and distal clavicle (ACD) of normal AC joints with and without plates were measured. Results Mismatch was found when the hook plates were implanted, with an average CPA of 18.8 ± 5.1° with the 15-mm hook plate and 10.2 ± 4.9° with the 18-mm hook plate. To eliminate the CPA, the ACD decreased by 6.3 ± 1.1 mm with the 15-mm hook plate and 2.9 ± 0.9 mm with the 18-mm hook plate. Conclusions The results revealed that AO clavicular hook plates with different hook depths were very likely to result in over-reduction of the AC joint. It is necessary to bend the hook angle to fit the patient’s AC joint to achieve accurate reduction. | ||
650 | 4 | |a Acromioclavicular joint |7 (dpeaa)DE-He213 | |
650 | 4 | |a Hook plate |7 (dpeaa)DE-He213 | |
650 | 4 | |a 3D printing |7 (dpeaa)DE-He213 | |
650 | 4 | |a Matching performance |7 (dpeaa)DE-He213 | |
700 | 1 | |a Wang, Gang |e verfasserin |4 aut | |
700 | 1 | |a Xia, Qingquan |e verfasserin |4 aut | |
700 | 1 | |a Rong, Ke |e verfasserin |4 aut | |
700 | 1 | |a Gan, Minfeng |e verfasserin |4 aut | |
700 | 1 | |a Wen, Gen |e verfasserin |4 aut | |
700 | 1 | |a Yin, Xiaofan |e verfasserin |4 aut | |
700 | 1 | |a Yang, Huilin |e verfasserin |4 aut | |
773 | 0 | 8 | |i Enthalten in |t Indian journal of orthopaedics |d Varanasi : Assoc., 2004 |g 54(2020), 2 vom: 24. Jan., Seite 141-147 |w (DE-627)531202356 |w (DE-600)2323559-7 |x 1998-3727 |7 nnns |
773 | 1 | 8 | |g volume:54 |g year:2020 |g number:2 |g day:24 |g month:01 |g pages:141-147 |
856 | 4 | 0 | |u https://dx.doi.org/10.1007/s43465-019-00034-0 |z lizenzpflichtig |3 Volltext |
912 | |a GBV_USEFLAG_A | ||
912 | |a SYSFLAG_A | ||
912 | |a GBV_SPRINGER | ||
912 | |a SSG-OLC-PHA | ||
912 | |a GBV_ILN_11 | ||
912 | |a GBV_ILN_20 | ||
912 | |a GBV_ILN_22 | ||
912 | |a GBV_ILN_23 | ||
912 | |a GBV_ILN_24 | ||
912 | |a GBV_ILN_31 | ||
912 | |a GBV_ILN_32 | ||
912 | |a GBV_ILN_39 | ||
912 | |a GBV_ILN_40 | ||
912 | |a GBV_ILN_60 | ||
912 | |a GBV_ILN_62 | ||
912 | |a GBV_ILN_63 | ||
912 | |a GBV_ILN_65 | ||
912 | |a GBV_ILN_69 | ||
912 | |a GBV_ILN_70 | ||
912 | |a GBV_ILN_73 | ||
912 | |a GBV_ILN_74 | ||
912 | |a GBV_ILN_90 | ||
912 | |a GBV_ILN_95 | ||
912 | |a GBV_ILN_100 | ||
912 | |a GBV_ILN_101 | ||
912 | |a GBV_ILN_105 | ||
912 | |a GBV_ILN_110 | ||
912 | |a GBV_ILN_138 | ||
912 | |a GBV_ILN_150 | ||
912 | |a GBV_ILN_151 | ||
912 | |a GBV_ILN_152 | ||
912 | |a GBV_ILN_161 | ||
912 | |a GBV_ILN_170 | ||
912 | |a GBV_ILN_171 | ||
912 | |a GBV_ILN_187 | ||
912 | |a GBV_ILN_206 | ||
912 | |a GBV_ILN_213 | ||
912 | |a GBV_ILN_224 | ||
912 | |a GBV_ILN_230 | ||
912 | |a GBV_ILN_250 | ||
912 | |a GBV_ILN_281 | ||
912 | |a GBV_ILN_285 | ||
912 | |a GBV_ILN_293 | ||
912 | |a GBV_ILN_370 | ||
912 | |a GBV_ILN_602 | ||
912 | |a GBV_ILN_636 | ||
912 | |a GBV_ILN_702 | ||
912 | |a GBV_ILN_2001 | ||
912 | |a GBV_ILN_2003 | ||
912 | |a GBV_ILN_2004 | ||
912 | |a GBV_ILN_2005 | ||
912 | |a GBV_ILN_2006 | ||
912 | |a GBV_ILN_2007 | ||
912 | |a GBV_ILN_2008 | ||
912 | |a GBV_ILN_2009 | ||
912 | |a GBV_ILN_2010 | ||
912 | |a GBV_ILN_2011 | ||
912 | |a GBV_ILN_2014 | ||
912 | |a GBV_ILN_2015 | ||
912 | |a GBV_ILN_2020 | ||
912 | |a GBV_ILN_2021 | ||
912 | |a GBV_ILN_2025 | ||
912 | |a GBV_ILN_2026 | ||
912 | |a GBV_ILN_2027 | ||
912 | |a GBV_ILN_2031 | ||
912 | |a GBV_ILN_2034 | ||
912 | |a GBV_ILN_2037 | ||
912 | |a GBV_ILN_2038 | ||
912 | |a GBV_ILN_2039 | ||
912 | |a GBV_ILN_2044 | ||
912 | |a GBV_ILN_2048 | ||
912 | |a GBV_ILN_2049 | ||
912 | |a GBV_ILN_2050 | ||
912 | |a GBV_ILN_2055 | ||
912 | |a GBV_ILN_2056 | ||
912 | |a GBV_ILN_2057 | ||
912 | |a GBV_ILN_2059 | ||
912 | |a GBV_ILN_2061 | ||
912 | |a GBV_ILN_2064 | ||
912 | |a GBV_ILN_2065 | ||
912 | |a GBV_ILN_2068 | ||
912 | |a GBV_ILN_2088 | ||
912 | |a GBV_ILN_2093 | ||
912 | |a GBV_ILN_2106 | ||
912 | |a GBV_ILN_2107 | ||
912 | |a GBV_ILN_2108 | ||
912 | |a GBV_ILN_2110 | ||
912 | |a GBV_ILN_2111 | ||
912 | |a GBV_ILN_2112 | ||
912 | |a GBV_ILN_2113 | ||
912 | |a GBV_ILN_2118 | ||
912 | |a GBV_ILN_2122 | ||
912 | |a GBV_ILN_2129 | ||
912 | |a GBV_ILN_2143 | ||
912 | |a GBV_ILN_2144 | ||
912 | |a GBV_ILN_2147 | ||
912 | |a GBV_ILN_2148 | ||
912 | |a GBV_ILN_2152 | ||
912 | |a GBV_ILN_2153 | ||
912 | |a GBV_ILN_2190 | ||
912 | |a GBV_ILN_2232 | ||
912 | |a GBV_ILN_2336 | ||
912 | |a GBV_ILN_2446 | ||
912 | |a GBV_ILN_2470 | ||
912 | |a GBV_ILN_2472 | ||
912 | |a GBV_ILN_2507 | ||
912 | |a GBV_ILN_2522 | ||
912 | |a GBV_ILN_4012 | ||
912 | |a GBV_ILN_4035 | ||
912 | |a GBV_ILN_4037 | ||
912 | |a GBV_ILN_4046 | ||
912 | |a GBV_ILN_4112 | ||
912 | |a GBV_ILN_4125 | ||
912 | |a GBV_ILN_4126 | ||
912 | |a GBV_ILN_4242 | ||
912 | |a GBV_ILN_4246 | ||
912 | |a GBV_ILN_4249 | ||
912 | |a GBV_ILN_4251 | ||
912 | |a GBV_ILN_4305 | ||
912 | |a GBV_ILN_4306 | ||
912 | |a GBV_ILN_4307 | ||
912 | |a GBV_ILN_4313 | ||
912 | |a GBV_ILN_4322 | ||
912 | |a GBV_ILN_4323 | ||
912 | |a GBV_ILN_4324 | ||
912 | |a GBV_ILN_4325 | ||
912 | |a GBV_ILN_4326 | ||
912 | |a GBV_ILN_4328 | ||
912 | |a GBV_ILN_4333 | ||
912 | |a GBV_ILN_4334 | ||
912 | |a GBV_ILN_4335 | ||
912 | |a GBV_ILN_4336 | ||
912 | |a GBV_ILN_4338 | ||
912 | |a GBV_ILN_4367 | ||
912 | |a GBV_ILN_4393 | ||
912 | |a GBV_ILN_4700 | ||
951 | |a AR | ||
952 | |d 54 |j 2020 |e 2 |b 24 |c 01 |h 141-147 |
author_variant |
x w xw g w gw q x qx k r kr m g mg g w gw x y xy h y hy |
---|---|
matchkey_str |
article:19983727:2020----::iiatcnlgcmiewt3pitnteautteacigefra |
hierarchy_sort_str |
2020 |
publishDate |
2020 |
allfields |
10.1007/s43465-019-00034-0 doi (DE-627)SPR03921379X (SPR)s43465-019-00034-0-e DE-627 ger DE-627 rakwb eng 610 ASE Wu, Xuhua verfasserin aut Digital Technology Combined with 3D Printing to Evaluate the Matching Performance of AO Clavicular Hook Plates 2020 Text txt rdacontent Computermedien c rdamedia Online-Ressource cr rdacarrier Background AO clavicular hook plates have been widely used for treating acromioclavicular (AC) joint dislocation and distal clavicle fractures. Many complications have been reported, and many patients have complained about the discomfort of the plate. However, no study on the impact of clavicular hook plates in AC joint 3D printing models has been reported. Objective To evaluate the matching performance of hook plates with different hook depths when they were implanted in 3D printing models of normal Chinese AC joints and to propose a further design to achieve a better match. Methods AO clavicular hook plates with two different hook depths of 15 mm and 18 mm were implanted in 3D printing models of forty Chinese normal AC joints. The angle between the distal clavicle and plate (CPA) and the drop between acromion and distal clavicle (ACD) of normal AC joints with and without plates were measured. Results Mismatch was found when the hook plates were implanted, with an average CPA of 18.8 ± 5.1° with the 15-mm hook plate and 10.2 ± 4.9° with the 18-mm hook plate. To eliminate the CPA, the ACD decreased by 6.3 ± 1.1 mm with the 15-mm hook plate and 2.9 ± 0.9 mm with the 18-mm hook plate. Conclusions The results revealed that AO clavicular hook plates with different hook depths were very likely to result in over-reduction of the AC joint. It is necessary to bend the hook angle to fit the patient’s AC joint to achieve accurate reduction. Acromioclavicular joint (dpeaa)DE-He213 Hook plate (dpeaa)DE-He213 3D printing (dpeaa)DE-He213 Matching performance (dpeaa)DE-He213 Wang, Gang verfasserin aut Xia, Qingquan verfasserin aut Rong, Ke verfasserin aut Gan, Minfeng verfasserin aut Wen, Gen verfasserin aut Yin, Xiaofan verfasserin aut Yang, Huilin verfasserin aut Enthalten in Indian journal of orthopaedics Varanasi : Assoc., 2004 54(2020), 2 vom: 24. Jan., Seite 141-147 (DE-627)531202356 (DE-600)2323559-7 1998-3727 nnns volume:54 year:2020 number:2 day:24 month:01 pages:141-147 https://dx.doi.org/10.1007/s43465-019-00034-0 lizenzpflichtig Volltext GBV_USEFLAG_A SYSFLAG_A GBV_SPRINGER SSG-OLC-PHA GBV_ILN_11 GBV_ILN_20 GBV_ILN_22 GBV_ILN_23 GBV_ILN_24 GBV_ILN_31 GBV_ILN_32 GBV_ILN_39 GBV_ILN_40 GBV_ILN_60 GBV_ILN_62 GBV_ILN_63 GBV_ILN_65 GBV_ILN_69 GBV_ILN_70 GBV_ILN_73 GBV_ILN_74 GBV_ILN_90 GBV_ILN_95 GBV_ILN_100 GBV_ILN_101 GBV_ILN_105 GBV_ILN_110 GBV_ILN_138 GBV_ILN_150 GBV_ILN_151 GBV_ILN_152 GBV_ILN_161 GBV_ILN_170 GBV_ILN_171 GBV_ILN_187 GBV_ILN_206 GBV_ILN_213 GBV_ILN_224 GBV_ILN_230 GBV_ILN_250 GBV_ILN_281 GBV_ILN_285 GBV_ILN_293 GBV_ILN_370 GBV_ILN_602 GBV_ILN_636 GBV_ILN_702 GBV_ILN_2001 GBV_ILN_2003 GBV_ILN_2004 GBV_ILN_2005 GBV_ILN_2006 GBV_ILN_2007 GBV_ILN_2008 GBV_ILN_2009 GBV_ILN_2010 GBV_ILN_2011 GBV_ILN_2014 GBV_ILN_2015 GBV_ILN_2020 GBV_ILN_2021 GBV_ILN_2025 GBV_ILN_2026 GBV_ILN_2027 GBV_ILN_2031 GBV_ILN_2034 GBV_ILN_2037 GBV_ILN_2038 GBV_ILN_2039 GBV_ILN_2044 GBV_ILN_2048 GBV_ILN_2049 GBV_ILN_2050 GBV_ILN_2055 GBV_ILN_2056 GBV_ILN_2057 GBV_ILN_2059 GBV_ILN_2061 GBV_ILN_2064 GBV_ILN_2065 GBV_ILN_2068 GBV_ILN_2088 GBV_ILN_2093 GBV_ILN_2106 GBV_ILN_2107 GBV_ILN_2108 GBV_ILN_2110 GBV_ILN_2111 GBV_ILN_2112 GBV_ILN_2113 GBV_ILN_2118 GBV_ILN_2122 GBV_ILN_2129 GBV_ILN_2143 GBV_ILN_2144 GBV_ILN_2147 GBV_ILN_2148 GBV_ILN_2152 GBV_ILN_2153 GBV_ILN_2190 GBV_ILN_2232 GBV_ILN_2336 GBV_ILN_2446 GBV_ILN_2470 GBV_ILN_2472 GBV_ILN_2507 GBV_ILN_2522 GBV_ILN_4012 GBV_ILN_4035 GBV_ILN_4037 GBV_ILN_4046 GBV_ILN_4112 GBV_ILN_4125 GBV_ILN_4126 GBV_ILN_4242 GBV_ILN_4246 GBV_ILN_4249 GBV_ILN_4251 GBV_ILN_4305 GBV_ILN_4306 GBV_ILN_4307 GBV_ILN_4313 GBV_ILN_4322 GBV_ILN_4323 GBV_ILN_4324 GBV_ILN_4325 GBV_ILN_4326 GBV_ILN_4328 GBV_ILN_4333 GBV_ILN_4334 GBV_ILN_4335 GBV_ILN_4336 GBV_ILN_4338 GBV_ILN_4367 GBV_ILN_4393 GBV_ILN_4700 AR 54 2020 2 24 01 141-147 |
spelling |
10.1007/s43465-019-00034-0 doi (DE-627)SPR03921379X (SPR)s43465-019-00034-0-e DE-627 ger DE-627 rakwb eng 610 ASE Wu, Xuhua verfasserin aut Digital Technology Combined with 3D Printing to Evaluate the Matching Performance of AO Clavicular Hook Plates 2020 Text txt rdacontent Computermedien c rdamedia Online-Ressource cr rdacarrier Background AO clavicular hook plates have been widely used for treating acromioclavicular (AC) joint dislocation and distal clavicle fractures. Many complications have been reported, and many patients have complained about the discomfort of the plate. However, no study on the impact of clavicular hook plates in AC joint 3D printing models has been reported. Objective To evaluate the matching performance of hook plates with different hook depths when they were implanted in 3D printing models of normal Chinese AC joints and to propose a further design to achieve a better match. Methods AO clavicular hook plates with two different hook depths of 15 mm and 18 mm were implanted in 3D printing models of forty Chinese normal AC joints. The angle between the distal clavicle and plate (CPA) and the drop between acromion and distal clavicle (ACD) of normal AC joints with and without plates were measured. Results Mismatch was found when the hook plates were implanted, with an average CPA of 18.8 ± 5.1° with the 15-mm hook plate and 10.2 ± 4.9° with the 18-mm hook plate. To eliminate the CPA, the ACD decreased by 6.3 ± 1.1 mm with the 15-mm hook plate and 2.9 ± 0.9 mm with the 18-mm hook plate. Conclusions The results revealed that AO clavicular hook plates with different hook depths were very likely to result in over-reduction of the AC joint. It is necessary to bend the hook angle to fit the patient’s AC joint to achieve accurate reduction. Acromioclavicular joint (dpeaa)DE-He213 Hook plate (dpeaa)DE-He213 3D printing (dpeaa)DE-He213 Matching performance (dpeaa)DE-He213 Wang, Gang verfasserin aut Xia, Qingquan verfasserin aut Rong, Ke verfasserin aut Gan, Minfeng verfasserin aut Wen, Gen verfasserin aut Yin, Xiaofan verfasserin aut Yang, Huilin verfasserin aut Enthalten in Indian journal of orthopaedics Varanasi : Assoc., 2004 54(2020), 2 vom: 24. Jan., Seite 141-147 (DE-627)531202356 (DE-600)2323559-7 1998-3727 nnns volume:54 year:2020 number:2 day:24 month:01 pages:141-147 https://dx.doi.org/10.1007/s43465-019-00034-0 lizenzpflichtig Volltext GBV_USEFLAG_A SYSFLAG_A GBV_SPRINGER SSG-OLC-PHA GBV_ILN_11 GBV_ILN_20 GBV_ILN_22 GBV_ILN_23 GBV_ILN_24 GBV_ILN_31 GBV_ILN_32 GBV_ILN_39 GBV_ILN_40 GBV_ILN_60 GBV_ILN_62 GBV_ILN_63 GBV_ILN_65 GBV_ILN_69 GBV_ILN_70 GBV_ILN_73 GBV_ILN_74 GBV_ILN_90 GBV_ILN_95 GBV_ILN_100 GBV_ILN_101 GBV_ILN_105 GBV_ILN_110 GBV_ILN_138 GBV_ILN_150 GBV_ILN_151 GBV_ILN_152 GBV_ILN_161 GBV_ILN_170 GBV_ILN_171 GBV_ILN_187 GBV_ILN_206 GBV_ILN_213 GBV_ILN_224 GBV_ILN_230 GBV_ILN_250 GBV_ILN_281 GBV_ILN_285 GBV_ILN_293 GBV_ILN_370 GBV_ILN_602 GBV_ILN_636 GBV_ILN_702 GBV_ILN_2001 GBV_ILN_2003 GBV_ILN_2004 GBV_ILN_2005 GBV_ILN_2006 GBV_ILN_2007 GBV_ILN_2008 GBV_ILN_2009 GBV_ILN_2010 GBV_ILN_2011 GBV_ILN_2014 GBV_ILN_2015 GBV_ILN_2020 GBV_ILN_2021 GBV_ILN_2025 GBV_ILN_2026 GBV_ILN_2027 GBV_ILN_2031 GBV_ILN_2034 GBV_ILN_2037 GBV_ILN_2038 GBV_ILN_2039 GBV_ILN_2044 GBV_ILN_2048 GBV_ILN_2049 GBV_ILN_2050 GBV_ILN_2055 GBV_ILN_2056 GBV_ILN_2057 GBV_ILN_2059 GBV_ILN_2061 GBV_ILN_2064 GBV_ILN_2065 GBV_ILN_2068 GBV_ILN_2088 GBV_ILN_2093 GBV_ILN_2106 GBV_ILN_2107 GBV_ILN_2108 GBV_ILN_2110 GBV_ILN_2111 GBV_ILN_2112 GBV_ILN_2113 GBV_ILN_2118 GBV_ILN_2122 GBV_ILN_2129 GBV_ILN_2143 GBV_ILN_2144 GBV_ILN_2147 GBV_ILN_2148 GBV_ILN_2152 GBV_ILN_2153 GBV_ILN_2190 GBV_ILN_2232 GBV_ILN_2336 GBV_ILN_2446 GBV_ILN_2470 GBV_ILN_2472 GBV_ILN_2507 GBV_ILN_2522 GBV_ILN_4012 GBV_ILN_4035 GBV_ILN_4037 GBV_ILN_4046 GBV_ILN_4112 GBV_ILN_4125 GBV_ILN_4126 GBV_ILN_4242 GBV_ILN_4246 GBV_ILN_4249 GBV_ILN_4251 GBV_ILN_4305 GBV_ILN_4306 GBV_ILN_4307 GBV_ILN_4313 GBV_ILN_4322 GBV_ILN_4323 GBV_ILN_4324 GBV_ILN_4325 GBV_ILN_4326 GBV_ILN_4328 GBV_ILN_4333 GBV_ILN_4334 GBV_ILN_4335 GBV_ILN_4336 GBV_ILN_4338 GBV_ILN_4367 GBV_ILN_4393 GBV_ILN_4700 AR 54 2020 2 24 01 141-147 |
allfields_unstemmed |
10.1007/s43465-019-00034-0 doi (DE-627)SPR03921379X (SPR)s43465-019-00034-0-e DE-627 ger DE-627 rakwb eng 610 ASE Wu, Xuhua verfasserin aut Digital Technology Combined with 3D Printing to Evaluate the Matching Performance of AO Clavicular Hook Plates 2020 Text txt rdacontent Computermedien c rdamedia Online-Ressource cr rdacarrier Background AO clavicular hook plates have been widely used for treating acromioclavicular (AC) joint dislocation and distal clavicle fractures. Many complications have been reported, and many patients have complained about the discomfort of the plate. However, no study on the impact of clavicular hook plates in AC joint 3D printing models has been reported. Objective To evaluate the matching performance of hook plates with different hook depths when they were implanted in 3D printing models of normal Chinese AC joints and to propose a further design to achieve a better match. Methods AO clavicular hook plates with two different hook depths of 15 mm and 18 mm were implanted in 3D printing models of forty Chinese normal AC joints. The angle between the distal clavicle and plate (CPA) and the drop between acromion and distal clavicle (ACD) of normal AC joints with and without plates were measured. Results Mismatch was found when the hook plates were implanted, with an average CPA of 18.8 ± 5.1° with the 15-mm hook plate and 10.2 ± 4.9° with the 18-mm hook plate. To eliminate the CPA, the ACD decreased by 6.3 ± 1.1 mm with the 15-mm hook plate and 2.9 ± 0.9 mm with the 18-mm hook plate. Conclusions The results revealed that AO clavicular hook plates with different hook depths were very likely to result in over-reduction of the AC joint. It is necessary to bend the hook angle to fit the patient’s AC joint to achieve accurate reduction. Acromioclavicular joint (dpeaa)DE-He213 Hook plate (dpeaa)DE-He213 3D printing (dpeaa)DE-He213 Matching performance (dpeaa)DE-He213 Wang, Gang verfasserin aut Xia, Qingquan verfasserin aut Rong, Ke verfasserin aut Gan, Minfeng verfasserin aut Wen, Gen verfasserin aut Yin, Xiaofan verfasserin aut Yang, Huilin verfasserin aut Enthalten in Indian journal of orthopaedics Varanasi : Assoc., 2004 54(2020), 2 vom: 24. Jan., Seite 141-147 (DE-627)531202356 (DE-600)2323559-7 1998-3727 nnns volume:54 year:2020 number:2 day:24 month:01 pages:141-147 https://dx.doi.org/10.1007/s43465-019-00034-0 lizenzpflichtig Volltext GBV_USEFLAG_A SYSFLAG_A GBV_SPRINGER SSG-OLC-PHA GBV_ILN_11 GBV_ILN_20 GBV_ILN_22 GBV_ILN_23 GBV_ILN_24 GBV_ILN_31 GBV_ILN_32 GBV_ILN_39 GBV_ILN_40 GBV_ILN_60 GBV_ILN_62 GBV_ILN_63 GBV_ILN_65 GBV_ILN_69 GBV_ILN_70 GBV_ILN_73 GBV_ILN_74 GBV_ILN_90 GBV_ILN_95 GBV_ILN_100 GBV_ILN_101 GBV_ILN_105 GBV_ILN_110 GBV_ILN_138 GBV_ILN_150 GBV_ILN_151 GBV_ILN_152 GBV_ILN_161 GBV_ILN_170 GBV_ILN_171 GBV_ILN_187 GBV_ILN_206 GBV_ILN_213 GBV_ILN_224 GBV_ILN_230 GBV_ILN_250 GBV_ILN_281 GBV_ILN_285 GBV_ILN_293 GBV_ILN_370 GBV_ILN_602 GBV_ILN_636 GBV_ILN_702 GBV_ILN_2001 GBV_ILN_2003 GBV_ILN_2004 GBV_ILN_2005 GBV_ILN_2006 GBV_ILN_2007 GBV_ILN_2008 GBV_ILN_2009 GBV_ILN_2010 GBV_ILN_2011 GBV_ILN_2014 GBV_ILN_2015 GBV_ILN_2020 GBV_ILN_2021 GBV_ILN_2025 GBV_ILN_2026 GBV_ILN_2027 GBV_ILN_2031 GBV_ILN_2034 GBV_ILN_2037 GBV_ILN_2038 GBV_ILN_2039 GBV_ILN_2044 GBV_ILN_2048 GBV_ILN_2049 GBV_ILN_2050 GBV_ILN_2055 GBV_ILN_2056 GBV_ILN_2057 GBV_ILN_2059 GBV_ILN_2061 GBV_ILN_2064 GBV_ILN_2065 GBV_ILN_2068 GBV_ILN_2088 GBV_ILN_2093 GBV_ILN_2106 GBV_ILN_2107 GBV_ILN_2108 GBV_ILN_2110 GBV_ILN_2111 GBV_ILN_2112 GBV_ILN_2113 GBV_ILN_2118 GBV_ILN_2122 GBV_ILN_2129 GBV_ILN_2143 GBV_ILN_2144 GBV_ILN_2147 GBV_ILN_2148 GBV_ILN_2152 GBV_ILN_2153 GBV_ILN_2190 GBV_ILN_2232 GBV_ILN_2336 GBV_ILN_2446 GBV_ILN_2470 GBV_ILN_2472 GBV_ILN_2507 GBV_ILN_2522 GBV_ILN_4012 GBV_ILN_4035 GBV_ILN_4037 GBV_ILN_4046 GBV_ILN_4112 GBV_ILN_4125 GBV_ILN_4126 GBV_ILN_4242 GBV_ILN_4246 GBV_ILN_4249 GBV_ILN_4251 GBV_ILN_4305 GBV_ILN_4306 GBV_ILN_4307 GBV_ILN_4313 GBV_ILN_4322 GBV_ILN_4323 GBV_ILN_4324 GBV_ILN_4325 GBV_ILN_4326 GBV_ILN_4328 GBV_ILN_4333 GBV_ILN_4334 GBV_ILN_4335 GBV_ILN_4336 GBV_ILN_4338 GBV_ILN_4367 GBV_ILN_4393 GBV_ILN_4700 AR 54 2020 2 24 01 141-147 |
allfieldsGer |
10.1007/s43465-019-00034-0 doi (DE-627)SPR03921379X (SPR)s43465-019-00034-0-e DE-627 ger DE-627 rakwb eng 610 ASE Wu, Xuhua verfasserin aut Digital Technology Combined with 3D Printing to Evaluate the Matching Performance of AO Clavicular Hook Plates 2020 Text txt rdacontent Computermedien c rdamedia Online-Ressource cr rdacarrier Background AO clavicular hook plates have been widely used for treating acromioclavicular (AC) joint dislocation and distal clavicle fractures. Many complications have been reported, and many patients have complained about the discomfort of the plate. However, no study on the impact of clavicular hook plates in AC joint 3D printing models has been reported. Objective To evaluate the matching performance of hook plates with different hook depths when they were implanted in 3D printing models of normal Chinese AC joints and to propose a further design to achieve a better match. Methods AO clavicular hook plates with two different hook depths of 15 mm and 18 mm were implanted in 3D printing models of forty Chinese normal AC joints. The angle between the distal clavicle and plate (CPA) and the drop between acromion and distal clavicle (ACD) of normal AC joints with and without plates were measured. Results Mismatch was found when the hook plates were implanted, with an average CPA of 18.8 ± 5.1° with the 15-mm hook plate and 10.2 ± 4.9° with the 18-mm hook plate. To eliminate the CPA, the ACD decreased by 6.3 ± 1.1 mm with the 15-mm hook plate and 2.9 ± 0.9 mm with the 18-mm hook plate. Conclusions The results revealed that AO clavicular hook plates with different hook depths were very likely to result in over-reduction of the AC joint. It is necessary to bend the hook angle to fit the patient’s AC joint to achieve accurate reduction. Acromioclavicular joint (dpeaa)DE-He213 Hook plate (dpeaa)DE-He213 3D printing (dpeaa)DE-He213 Matching performance (dpeaa)DE-He213 Wang, Gang verfasserin aut Xia, Qingquan verfasserin aut Rong, Ke verfasserin aut Gan, Minfeng verfasserin aut Wen, Gen verfasserin aut Yin, Xiaofan verfasserin aut Yang, Huilin verfasserin aut Enthalten in Indian journal of orthopaedics Varanasi : Assoc., 2004 54(2020), 2 vom: 24. Jan., Seite 141-147 (DE-627)531202356 (DE-600)2323559-7 1998-3727 nnns volume:54 year:2020 number:2 day:24 month:01 pages:141-147 https://dx.doi.org/10.1007/s43465-019-00034-0 lizenzpflichtig Volltext GBV_USEFLAG_A SYSFLAG_A GBV_SPRINGER SSG-OLC-PHA GBV_ILN_11 GBV_ILN_20 GBV_ILN_22 GBV_ILN_23 GBV_ILN_24 GBV_ILN_31 GBV_ILN_32 GBV_ILN_39 GBV_ILN_40 GBV_ILN_60 GBV_ILN_62 GBV_ILN_63 GBV_ILN_65 GBV_ILN_69 GBV_ILN_70 GBV_ILN_73 GBV_ILN_74 GBV_ILN_90 GBV_ILN_95 GBV_ILN_100 GBV_ILN_101 GBV_ILN_105 GBV_ILN_110 GBV_ILN_138 GBV_ILN_150 GBV_ILN_151 GBV_ILN_152 GBV_ILN_161 GBV_ILN_170 GBV_ILN_171 GBV_ILN_187 GBV_ILN_206 GBV_ILN_213 GBV_ILN_224 GBV_ILN_230 GBV_ILN_250 GBV_ILN_281 GBV_ILN_285 GBV_ILN_293 GBV_ILN_370 GBV_ILN_602 GBV_ILN_636 GBV_ILN_702 GBV_ILN_2001 GBV_ILN_2003 GBV_ILN_2004 GBV_ILN_2005 GBV_ILN_2006 GBV_ILN_2007 GBV_ILN_2008 GBV_ILN_2009 GBV_ILN_2010 GBV_ILN_2011 GBV_ILN_2014 GBV_ILN_2015 GBV_ILN_2020 GBV_ILN_2021 GBV_ILN_2025 GBV_ILN_2026 GBV_ILN_2027 GBV_ILN_2031 GBV_ILN_2034 GBV_ILN_2037 GBV_ILN_2038 GBV_ILN_2039 GBV_ILN_2044 GBV_ILN_2048 GBV_ILN_2049 GBV_ILN_2050 GBV_ILN_2055 GBV_ILN_2056 GBV_ILN_2057 GBV_ILN_2059 GBV_ILN_2061 GBV_ILN_2064 GBV_ILN_2065 GBV_ILN_2068 GBV_ILN_2088 GBV_ILN_2093 GBV_ILN_2106 GBV_ILN_2107 GBV_ILN_2108 GBV_ILN_2110 GBV_ILN_2111 GBV_ILN_2112 GBV_ILN_2113 GBV_ILN_2118 GBV_ILN_2122 GBV_ILN_2129 GBV_ILN_2143 GBV_ILN_2144 GBV_ILN_2147 GBV_ILN_2148 GBV_ILN_2152 GBV_ILN_2153 GBV_ILN_2190 GBV_ILN_2232 GBV_ILN_2336 GBV_ILN_2446 GBV_ILN_2470 GBV_ILN_2472 GBV_ILN_2507 GBV_ILN_2522 GBV_ILN_4012 GBV_ILN_4035 GBV_ILN_4037 GBV_ILN_4046 GBV_ILN_4112 GBV_ILN_4125 GBV_ILN_4126 GBV_ILN_4242 GBV_ILN_4246 GBV_ILN_4249 GBV_ILN_4251 GBV_ILN_4305 GBV_ILN_4306 GBV_ILN_4307 GBV_ILN_4313 GBV_ILN_4322 GBV_ILN_4323 GBV_ILN_4324 GBV_ILN_4325 GBV_ILN_4326 GBV_ILN_4328 GBV_ILN_4333 GBV_ILN_4334 GBV_ILN_4335 GBV_ILN_4336 GBV_ILN_4338 GBV_ILN_4367 GBV_ILN_4393 GBV_ILN_4700 AR 54 2020 2 24 01 141-147 |
allfieldsSound |
10.1007/s43465-019-00034-0 doi (DE-627)SPR03921379X (SPR)s43465-019-00034-0-e DE-627 ger DE-627 rakwb eng 610 ASE Wu, Xuhua verfasserin aut Digital Technology Combined with 3D Printing to Evaluate the Matching Performance of AO Clavicular Hook Plates 2020 Text txt rdacontent Computermedien c rdamedia Online-Ressource cr rdacarrier Background AO clavicular hook plates have been widely used for treating acromioclavicular (AC) joint dislocation and distal clavicle fractures. Many complications have been reported, and many patients have complained about the discomfort of the plate. However, no study on the impact of clavicular hook plates in AC joint 3D printing models has been reported. Objective To evaluate the matching performance of hook plates with different hook depths when they were implanted in 3D printing models of normal Chinese AC joints and to propose a further design to achieve a better match. Methods AO clavicular hook plates with two different hook depths of 15 mm and 18 mm were implanted in 3D printing models of forty Chinese normal AC joints. The angle between the distal clavicle and plate (CPA) and the drop between acromion and distal clavicle (ACD) of normal AC joints with and without plates were measured. Results Mismatch was found when the hook plates were implanted, with an average CPA of 18.8 ± 5.1° with the 15-mm hook plate and 10.2 ± 4.9° with the 18-mm hook plate. To eliminate the CPA, the ACD decreased by 6.3 ± 1.1 mm with the 15-mm hook plate and 2.9 ± 0.9 mm with the 18-mm hook plate. Conclusions The results revealed that AO clavicular hook plates with different hook depths were very likely to result in over-reduction of the AC joint. It is necessary to bend the hook angle to fit the patient’s AC joint to achieve accurate reduction. Acromioclavicular joint (dpeaa)DE-He213 Hook plate (dpeaa)DE-He213 3D printing (dpeaa)DE-He213 Matching performance (dpeaa)DE-He213 Wang, Gang verfasserin aut Xia, Qingquan verfasserin aut Rong, Ke verfasserin aut Gan, Minfeng verfasserin aut Wen, Gen verfasserin aut Yin, Xiaofan verfasserin aut Yang, Huilin verfasserin aut Enthalten in Indian journal of orthopaedics Varanasi : Assoc., 2004 54(2020), 2 vom: 24. Jan., Seite 141-147 (DE-627)531202356 (DE-600)2323559-7 1998-3727 nnns volume:54 year:2020 number:2 day:24 month:01 pages:141-147 https://dx.doi.org/10.1007/s43465-019-00034-0 lizenzpflichtig Volltext GBV_USEFLAG_A SYSFLAG_A GBV_SPRINGER SSG-OLC-PHA GBV_ILN_11 GBV_ILN_20 GBV_ILN_22 GBV_ILN_23 GBV_ILN_24 GBV_ILN_31 GBV_ILN_32 GBV_ILN_39 GBV_ILN_40 GBV_ILN_60 GBV_ILN_62 GBV_ILN_63 GBV_ILN_65 GBV_ILN_69 GBV_ILN_70 GBV_ILN_73 GBV_ILN_74 GBV_ILN_90 GBV_ILN_95 GBV_ILN_100 GBV_ILN_101 GBV_ILN_105 GBV_ILN_110 GBV_ILN_138 GBV_ILN_150 GBV_ILN_151 GBV_ILN_152 GBV_ILN_161 GBV_ILN_170 GBV_ILN_171 GBV_ILN_187 GBV_ILN_206 GBV_ILN_213 GBV_ILN_224 GBV_ILN_230 GBV_ILN_250 GBV_ILN_281 GBV_ILN_285 GBV_ILN_293 GBV_ILN_370 GBV_ILN_602 GBV_ILN_636 GBV_ILN_702 GBV_ILN_2001 GBV_ILN_2003 GBV_ILN_2004 GBV_ILN_2005 GBV_ILN_2006 GBV_ILN_2007 GBV_ILN_2008 GBV_ILN_2009 GBV_ILN_2010 GBV_ILN_2011 GBV_ILN_2014 GBV_ILN_2015 GBV_ILN_2020 GBV_ILN_2021 GBV_ILN_2025 GBV_ILN_2026 GBV_ILN_2027 GBV_ILN_2031 GBV_ILN_2034 GBV_ILN_2037 GBV_ILN_2038 GBV_ILN_2039 GBV_ILN_2044 GBV_ILN_2048 GBV_ILN_2049 GBV_ILN_2050 GBV_ILN_2055 GBV_ILN_2056 GBV_ILN_2057 GBV_ILN_2059 GBV_ILN_2061 GBV_ILN_2064 GBV_ILN_2065 GBV_ILN_2068 GBV_ILN_2088 GBV_ILN_2093 GBV_ILN_2106 GBV_ILN_2107 GBV_ILN_2108 GBV_ILN_2110 GBV_ILN_2111 GBV_ILN_2112 GBV_ILN_2113 GBV_ILN_2118 GBV_ILN_2122 GBV_ILN_2129 GBV_ILN_2143 GBV_ILN_2144 GBV_ILN_2147 GBV_ILN_2148 GBV_ILN_2152 GBV_ILN_2153 GBV_ILN_2190 GBV_ILN_2232 GBV_ILN_2336 GBV_ILN_2446 GBV_ILN_2470 GBV_ILN_2472 GBV_ILN_2507 GBV_ILN_2522 GBV_ILN_4012 GBV_ILN_4035 GBV_ILN_4037 GBV_ILN_4046 GBV_ILN_4112 GBV_ILN_4125 GBV_ILN_4126 GBV_ILN_4242 GBV_ILN_4246 GBV_ILN_4249 GBV_ILN_4251 GBV_ILN_4305 GBV_ILN_4306 GBV_ILN_4307 GBV_ILN_4313 GBV_ILN_4322 GBV_ILN_4323 GBV_ILN_4324 GBV_ILN_4325 GBV_ILN_4326 GBV_ILN_4328 GBV_ILN_4333 GBV_ILN_4334 GBV_ILN_4335 GBV_ILN_4336 GBV_ILN_4338 GBV_ILN_4367 GBV_ILN_4393 GBV_ILN_4700 AR 54 2020 2 24 01 141-147 |
language |
English |
source |
Enthalten in Indian journal of orthopaedics 54(2020), 2 vom: 24. Jan., Seite 141-147 volume:54 year:2020 number:2 day:24 month:01 pages:141-147 |
sourceStr |
Enthalten in Indian journal of orthopaedics 54(2020), 2 vom: 24. Jan., Seite 141-147 volume:54 year:2020 number:2 day:24 month:01 pages:141-147 |
format_phy_str_mv |
Article |
institution |
findex.gbv.de |
topic_facet |
Acromioclavicular joint Hook plate 3D printing Matching performance |
dewey-raw |
610 |
isfreeaccess_bool |
false |
container_title |
Indian journal of orthopaedics |
authorswithroles_txt_mv |
Wu, Xuhua @@aut@@ Wang, Gang @@aut@@ Xia, Qingquan @@aut@@ Rong, Ke @@aut@@ Gan, Minfeng @@aut@@ Wen, Gen @@aut@@ Yin, Xiaofan @@aut@@ Yang, Huilin @@aut@@ |
publishDateDaySort_date |
2020-01-24T00:00:00Z |
hierarchy_top_id |
531202356 |
dewey-sort |
3610 |
id |
SPR03921379X |
language_de |
englisch |
fullrecord |
<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim"><record><leader>01000caa a22002652 4500</leader><controlfield tag="001">SPR03921379X</controlfield><controlfield tag="003">DE-627</controlfield><controlfield tag="005">20230519073242.0</controlfield><controlfield tag="007">cr uuu---uuuuu</controlfield><controlfield tag="008">201007s2020 xx |||||o 00| ||eng c</controlfield><datafield tag="024" ind1="7" ind2=" "><subfield code="a">10.1007/s43465-019-00034-0</subfield><subfield code="2">doi</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-627)SPR03921379X</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(SPR)s43465-019-00034-0-e</subfield></datafield><datafield tag="040" ind1=" " ind2=" "><subfield code="a">DE-627</subfield><subfield code="b">ger</subfield><subfield code="c">DE-627</subfield><subfield code="e">rakwb</subfield></datafield><datafield tag="041" ind1=" " ind2=" "><subfield code="a">eng</subfield></datafield><datafield tag="082" ind1="0" ind2="4"><subfield code="a">610</subfield><subfield code="q">ASE</subfield></datafield><datafield tag="100" ind1="1" ind2=" "><subfield code="a">Wu, Xuhua</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="245" ind1="1" ind2="0"><subfield code="a">Digital Technology Combined with 3D Printing to Evaluate the Matching Performance of AO Clavicular Hook Plates</subfield></datafield><datafield tag="264" ind1=" " ind2="1"><subfield code="c">2020</subfield></datafield><datafield tag="336" ind1=" " ind2=" "><subfield code="a">Text</subfield><subfield code="b">txt</subfield><subfield code="2">rdacontent</subfield></datafield><datafield tag="337" ind1=" " ind2=" "><subfield code="a">Computermedien</subfield><subfield code="b">c</subfield><subfield code="2">rdamedia</subfield></datafield><datafield tag="338" ind1=" " ind2=" "><subfield code="a">Online-Ressource</subfield><subfield code="b">cr</subfield><subfield code="2">rdacarrier</subfield></datafield><datafield tag="520" ind1=" " ind2=" "><subfield code="a">Background AO clavicular hook plates have been widely used for treating acromioclavicular (AC) joint dislocation and distal clavicle fractures. Many complications have been reported, and many patients have complained about the discomfort of the plate. However, no study on the impact of clavicular hook plates in AC joint 3D printing models has been reported. Objective To evaluate the matching performance of hook plates with different hook depths when they were implanted in 3D printing models of normal Chinese AC joints and to propose a further design to achieve a better match. Methods AO clavicular hook plates with two different hook depths of 15 mm and 18 mm were implanted in 3D printing models of forty Chinese normal AC joints. The angle between the distal clavicle and plate (CPA) and the drop between acromion and distal clavicle (ACD) of normal AC joints with and without plates were measured. Results Mismatch was found when the hook plates were implanted, with an average CPA of 18.8 ± 5.1° with the 15-mm hook plate and 10.2 ± 4.9° with the 18-mm hook plate. To eliminate the CPA, the ACD decreased by 6.3 ± 1.1 mm with the 15-mm hook plate and 2.9 ± 0.9 mm with the 18-mm hook plate. Conclusions The results revealed that AO clavicular hook plates with different hook depths were very likely to result in over-reduction of the AC joint. It is necessary to bend the hook angle to fit the patient’s AC joint to achieve accurate reduction.</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Acromioclavicular joint</subfield><subfield code="7">(dpeaa)DE-He213</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Hook plate</subfield><subfield code="7">(dpeaa)DE-He213</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">3D printing</subfield><subfield code="7">(dpeaa)DE-He213</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Matching performance</subfield><subfield code="7">(dpeaa)DE-He213</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Wang, Gang</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Xia, Qingquan</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Rong, Ke</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Gan, Minfeng</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Wen, Gen</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Yin, Xiaofan</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Yang, Huilin</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="773" ind1="0" ind2="8"><subfield code="i">Enthalten in</subfield><subfield code="t">Indian journal of orthopaedics</subfield><subfield code="d">Varanasi : Assoc., 2004</subfield><subfield code="g">54(2020), 2 vom: 24. Jan., Seite 141-147</subfield><subfield code="w">(DE-627)531202356</subfield><subfield code="w">(DE-600)2323559-7</subfield><subfield code="x">1998-3727</subfield><subfield code="7">nnns</subfield></datafield><datafield tag="773" ind1="1" ind2="8"><subfield code="g">volume:54</subfield><subfield code="g">year:2020</subfield><subfield code="g">number:2</subfield><subfield code="g">day:24</subfield><subfield code="g">month:01</subfield><subfield code="g">pages:141-147</subfield></datafield><datafield tag="856" ind1="4" ind2="0"><subfield code="u">https://dx.doi.org/10.1007/s43465-019-00034-0</subfield><subfield code="z">lizenzpflichtig</subfield><subfield code="3">Volltext</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_USEFLAG_A</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">SYSFLAG_A</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_SPRINGER</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">SSG-OLC-PHA</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_11</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_20</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_22</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_23</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_24</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_31</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_32</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_39</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_40</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_60</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_62</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_63</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_65</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_69</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_70</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_73</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_74</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_90</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_95</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_100</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_101</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_105</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_110</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_138</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_150</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_151</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_152</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_161</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_170</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_171</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_187</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_206</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_213</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_224</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_230</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_250</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_281</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_285</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_293</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_370</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_602</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_636</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_702</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2001</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2003</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2004</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2005</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2006</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2007</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2008</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2009</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2010</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2011</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2014</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2015</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2020</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2021</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2025</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2026</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2027</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2031</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2034</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2037</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2038</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2039</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2044</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2048</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2049</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2050</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2055</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2056</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2057</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2059</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2061</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2064</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2065</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2068</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2088</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2093</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2106</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2107</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2108</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2110</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2111</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2112</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2113</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2118</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2122</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2129</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2143</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2144</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2147</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2148</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2152</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2153</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2190</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2232</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2336</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2446</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2470</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2472</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2507</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2522</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4012</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4035</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4037</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4046</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4112</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4125</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4126</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4242</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4246</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4249</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4251</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4305</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4306</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4307</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4313</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4322</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4323</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4324</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4325</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4326</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4328</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4333</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4334</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4335</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4336</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4338</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4367</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4393</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4700</subfield></datafield><datafield tag="951" ind1=" " ind2=" "><subfield code="a">AR</subfield></datafield><datafield tag="952" ind1=" " ind2=" "><subfield code="d">54</subfield><subfield code="j">2020</subfield><subfield code="e">2</subfield><subfield code="b">24</subfield><subfield code="c">01</subfield><subfield code="h">141-147</subfield></datafield></record></collection>
|
author |
Wu, Xuhua |
spellingShingle |
Wu, Xuhua ddc 610 misc Acromioclavicular joint misc Hook plate misc 3D printing misc Matching performance Digital Technology Combined with 3D Printing to Evaluate the Matching Performance of AO Clavicular Hook Plates |
authorStr |
Wu, Xuhua |
ppnlink_with_tag_str_mv |
@@773@@(DE-627)531202356 |
format |
electronic Article |
dewey-ones |
610 - Medicine & health |
delete_txt_mv |
keep |
author_role |
aut aut aut aut aut aut aut aut |
collection |
springer |
remote_str |
true |
illustrated |
Not Illustrated |
issn |
1998-3727 |
topic_title |
610 ASE Digital Technology Combined with 3D Printing to Evaluate the Matching Performance of AO Clavicular Hook Plates Acromioclavicular joint (dpeaa)DE-He213 Hook plate (dpeaa)DE-He213 3D printing (dpeaa)DE-He213 Matching performance (dpeaa)DE-He213 |
topic |
ddc 610 misc Acromioclavicular joint misc Hook plate misc 3D printing misc Matching performance |
topic_unstemmed |
ddc 610 misc Acromioclavicular joint misc Hook plate misc 3D printing misc Matching performance |
topic_browse |
ddc 610 misc Acromioclavicular joint misc Hook plate misc 3D printing misc Matching performance |
format_facet |
Elektronische Aufsätze Aufsätze Elektronische Ressource |
format_main_str_mv |
Text Zeitschrift/Artikel |
carriertype_str_mv |
cr |
hierarchy_parent_title |
Indian journal of orthopaedics |
hierarchy_parent_id |
531202356 |
dewey-tens |
610 - Medicine & health |
hierarchy_top_title |
Indian journal of orthopaedics |
isfreeaccess_txt |
false |
familylinks_str_mv |
(DE-627)531202356 (DE-600)2323559-7 |
title |
Digital Technology Combined with 3D Printing to Evaluate the Matching Performance of AO Clavicular Hook Plates |
ctrlnum |
(DE-627)SPR03921379X (SPR)s43465-019-00034-0-e |
title_full |
Digital Technology Combined with 3D Printing to Evaluate the Matching Performance of AO Clavicular Hook Plates |
author_sort |
Wu, Xuhua |
journal |
Indian journal of orthopaedics |
journalStr |
Indian journal of orthopaedics |
lang_code |
eng |
isOA_bool |
false |
dewey-hundreds |
600 - Technology |
recordtype |
marc |
publishDateSort |
2020 |
contenttype_str_mv |
txt |
container_start_page |
141 |
author_browse |
Wu, Xuhua Wang, Gang Xia, Qingquan Rong, Ke Gan, Minfeng Wen, Gen Yin, Xiaofan Yang, Huilin |
container_volume |
54 |
class |
610 ASE |
format_se |
Elektronische Aufsätze |
author-letter |
Wu, Xuhua |
doi_str_mv |
10.1007/s43465-019-00034-0 |
dewey-full |
610 |
author2-role |
verfasserin |
title_sort |
digital technology combined with 3d printing to evaluate the matching performance of ao clavicular hook plates |
title_auth |
Digital Technology Combined with 3D Printing to Evaluate the Matching Performance of AO Clavicular Hook Plates |
abstract |
Background AO clavicular hook plates have been widely used for treating acromioclavicular (AC) joint dislocation and distal clavicle fractures. Many complications have been reported, and many patients have complained about the discomfort of the plate. However, no study on the impact of clavicular hook plates in AC joint 3D printing models has been reported. Objective To evaluate the matching performance of hook plates with different hook depths when they were implanted in 3D printing models of normal Chinese AC joints and to propose a further design to achieve a better match. Methods AO clavicular hook plates with two different hook depths of 15 mm and 18 mm were implanted in 3D printing models of forty Chinese normal AC joints. The angle between the distal clavicle and plate (CPA) and the drop between acromion and distal clavicle (ACD) of normal AC joints with and without plates were measured. Results Mismatch was found when the hook plates were implanted, with an average CPA of 18.8 ± 5.1° with the 15-mm hook plate and 10.2 ± 4.9° with the 18-mm hook plate. To eliminate the CPA, the ACD decreased by 6.3 ± 1.1 mm with the 15-mm hook plate and 2.9 ± 0.9 mm with the 18-mm hook plate. Conclusions The results revealed that AO clavicular hook plates with different hook depths were very likely to result in over-reduction of the AC joint. It is necessary to bend the hook angle to fit the patient’s AC joint to achieve accurate reduction. |
abstractGer |
Background AO clavicular hook plates have been widely used for treating acromioclavicular (AC) joint dislocation and distal clavicle fractures. Many complications have been reported, and many patients have complained about the discomfort of the plate. However, no study on the impact of clavicular hook plates in AC joint 3D printing models has been reported. Objective To evaluate the matching performance of hook plates with different hook depths when they were implanted in 3D printing models of normal Chinese AC joints and to propose a further design to achieve a better match. Methods AO clavicular hook plates with two different hook depths of 15 mm and 18 mm were implanted in 3D printing models of forty Chinese normal AC joints. The angle between the distal clavicle and plate (CPA) and the drop between acromion and distal clavicle (ACD) of normal AC joints with and without plates were measured. Results Mismatch was found when the hook plates were implanted, with an average CPA of 18.8 ± 5.1° with the 15-mm hook plate and 10.2 ± 4.9° with the 18-mm hook plate. To eliminate the CPA, the ACD decreased by 6.3 ± 1.1 mm with the 15-mm hook plate and 2.9 ± 0.9 mm with the 18-mm hook plate. Conclusions The results revealed that AO clavicular hook plates with different hook depths were very likely to result in over-reduction of the AC joint. It is necessary to bend the hook angle to fit the patient’s AC joint to achieve accurate reduction. |
abstract_unstemmed |
Background AO clavicular hook plates have been widely used for treating acromioclavicular (AC) joint dislocation and distal clavicle fractures. Many complications have been reported, and many patients have complained about the discomfort of the plate. However, no study on the impact of clavicular hook plates in AC joint 3D printing models has been reported. Objective To evaluate the matching performance of hook plates with different hook depths when they were implanted in 3D printing models of normal Chinese AC joints and to propose a further design to achieve a better match. Methods AO clavicular hook plates with two different hook depths of 15 mm and 18 mm were implanted in 3D printing models of forty Chinese normal AC joints. The angle between the distal clavicle and plate (CPA) and the drop between acromion and distal clavicle (ACD) of normal AC joints with and without plates were measured. Results Mismatch was found when the hook plates were implanted, with an average CPA of 18.8 ± 5.1° with the 15-mm hook plate and 10.2 ± 4.9° with the 18-mm hook plate. To eliminate the CPA, the ACD decreased by 6.3 ± 1.1 mm with the 15-mm hook plate and 2.9 ± 0.9 mm with the 18-mm hook plate. Conclusions The results revealed that AO clavicular hook plates with different hook depths were very likely to result in over-reduction of the AC joint. It is necessary to bend the hook angle to fit the patient’s AC joint to achieve accurate reduction. |
collection_details |
GBV_USEFLAG_A SYSFLAG_A GBV_SPRINGER SSG-OLC-PHA GBV_ILN_11 GBV_ILN_20 GBV_ILN_22 GBV_ILN_23 GBV_ILN_24 GBV_ILN_31 GBV_ILN_32 GBV_ILN_39 GBV_ILN_40 GBV_ILN_60 GBV_ILN_62 GBV_ILN_63 GBV_ILN_65 GBV_ILN_69 GBV_ILN_70 GBV_ILN_73 GBV_ILN_74 GBV_ILN_90 GBV_ILN_95 GBV_ILN_100 GBV_ILN_101 GBV_ILN_105 GBV_ILN_110 GBV_ILN_138 GBV_ILN_150 GBV_ILN_151 GBV_ILN_152 GBV_ILN_161 GBV_ILN_170 GBV_ILN_171 GBV_ILN_187 GBV_ILN_206 GBV_ILN_213 GBV_ILN_224 GBV_ILN_230 GBV_ILN_250 GBV_ILN_281 GBV_ILN_285 GBV_ILN_293 GBV_ILN_370 GBV_ILN_602 GBV_ILN_636 GBV_ILN_702 GBV_ILN_2001 GBV_ILN_2003 GBV_ILN_2004 GBV_ILN_2005 GBV_ILN_2006 GBV_ILN_2007 GBV_ILN_2008 GBV_ILN_2009 GBV_ILN_2010 GBV_ILN_2011 GBV_ILN_2014 GBV_ILN_2015 GBV_ILN_2020 GBV_ILN_2021 GBV_ILN_2025 GBV_ILN_2026 GBV_ILN_2027 GBV_ILN_2031 GBV_ILN_2034 GBV_ILN_2037 GBV_ILN_2038 GBV_ILN_2039 GBV_ILN_2044 GBV_ILN_2048 GBV_ILN_2049 GBV_ILN_2050 GBV_ILN_2055 GBV_ILN_2056 GBV_ILN_2057 GBV_ILN_2059 GBV_ILN_2061 GBV_ILN_2064 GBV_ILN_2065 GBV_ILN_2068 GBV_ILN_2088 GBV_ILN_2093 GBV_ILN_2106 GBV_ILN_2107 GBV_ILN_2108 GBV_ILN_2110 GBV_ILN_2111 GBV_ILN_2112 GBV_ILN_2113 GBV_ILN_2118 GBV_ILN_2122 GBV_ILN_2129 GBV_ILN_2143 GBV_ILN_2144 GBV_ILN_2147 GBV_ILN_2148 GBV_ILN_2152 GBV_ILN_2153 GBV_ILN_2190 GBV_ILN_2232 GBV_ILN_2336 GBV_ILN_2446 GBV_ILN_2470 GBV_ILN_2472 GBV_ILN_2507 GBV_ILN_2522 GBV_ILN_4012 GBV_ILN_4035 GBV_ILN_4037 GBV_ILN_4046 GBV_ILN_4112 GBV_ILN_4125 GBV_ILN_4126 GBV_ILN_4242 GBV_ILN_4246 GBV_ILN_4249 GBV_ILN_4251 GBV_ILN_4305 GBV_ILN_4306 GBV_ILN_4307 GBV_ILN_4313 GBV_ILN_4322 GBV_ILN_4323 GBV_ILN_4324 GBV_ILN_4325 GBV_ILN_4326 GBV_ILN_4328 GBV_ILN_4333 GBV_ILN_4334 GBV_ILN_4335 GBV_ILN_4336 GBV_ILN_4338 GBV_ILN_4367 GBV_ILN_4393 GBV_ILN_4700 |
container_issue |
2 |
title_short |
Digital Technology Combined with 3D Printing to Evaluate the Matching Performance of AO Clavicular Hook Plates |
url |
https://dx.doi.org/10.1007/s43465-019-00034-0 |
remote_bool |
true |
author2 |
Wang, Gang Xia, Qingquan Rong, Ke Gan, Minfeng Wen, Gen Yin, Xiaofan Yang, Huilin |
author2Str |
Wang, Gang Xia, Qingquan Rong, Ke Gan, Minfeng Wen, Gen Yin, Xiaofan Yang, Huilin |
ppnlink |
531202356 |
mediatype_str_mv |
c |
isOA_txt |
false |
hochschulschrift_bool |
false |
doi_str |
10.1007/s43465-019-00034-0 |
up_date |
2024-07-03T22:41:31.380Z |
_version_ |
1803599469761003521 |
fullrecord_marcxml |
<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim"><record><leader>01000caa a22002652 4500</leader><controlfield tag="001">SPR03921379X</controlfield><controlfield tag="003">DE-627</controlfield><controlfield tag="005">20230519073242.0</controlfield><controlfield tag="007">cr uuu---uuuuu</controlfield><controlfield tag="008">201007s2020 xx |||||o 00| ||eng c</controlfield><datafield tag="024" ind1="7" ind2=" "><subfield code="a">10.1007/s43465-019-00034-0</subfield><subfield code="2">doi</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-627)SPR03921379X</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(SPR)s43465-019-00034-0-e</subfield></datafield><datafield tag="040" ind1=" " ind2=" "><subfield code="a">DE-627</subfield><subfield code="b">ger</subfield><subfield code="c">DE-627</subfield><subfield code="e">rakwb</subfield></datafield><datafield tag="041" ind1=" " ind2=" "><subfield code="a">eng</subfield></datafield><datafield tag="082" ind1="0" ind2="4"><subfield code="a">610</subfield><subfield code="q">ASE</subfield></datafield><datafield tag="100" ind1="1" ind2=" "><subfield code="a">Wu, Xuhua</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="245" ind1="1" ind2="0"><subfield code="a">Digital Technology Combined with 3D Printing to Evaluate the Matching Performance of AO Clavicular Hook Plates</subfield></datafield><datafield tag="264" ind1=" " ind2="1"><subfield code="c">2020</subfield></datafield><datafield tag="336" ind1=" " ind2=" "><subfield code="a">Text</subfield><subfield code="b">txt</subfield><subfield code="2">rdacontent</subfield></datafield><datafield tag="337" ind1=" " ind2=" "><subfield code="a">Computermedien</subfield><subfield code="b">c</subfield><subfield code="2">rdamedia</subfield></datafield><datafield tag="338" ind1=" " ind2=" "><subfield code="a">Online-Ressource</subfield><subfield code="b">cr</subfield><subfield code="2">rdacarrier</subfield></datafield><datafield tag="520" ind1=" " ind2=" "><subfield code="a">Background AO clavicular hook plates have been widely used for treating acromioclavicular (AC) joint dislocation and distal clavicle fractures. Many complications have been reported, and many patients have complained about the discomfort of the plate. However, no study on the impact of clavicular hook plates in AC joint 3D printing models has been reported. Objective To evaluate the matching performance of hook plates with different hook depths when they were implanted in 3D printing models of normal Chinese AC joints and to propose a further design to achieve a better match. Methods AO clavicular hook plates with two different hook depths of 15 mm and 18 mm were implanted in 3D printing models of forty Chinese normal AC joints. The angle between the distal clavicle and plate (CPA) and the drop between acromion and distal clavicle (ACD) of normal AC joints with and without plates were measured. Results Mismatch was found when the hook plates were implanted, with an average CPA of 18.8 ± 5.1° with the 15-mm hook plate and 10.2 ± 4.9° with the 18-mm hook plate. To eliminate the CPA, the ACD decreased by 6.3 ± 1.1 mm with the 15-mm hook plate and 2.9 ± 0.9 mm with the 18-mm hook plate. Conclusions The results revealed that AO clavicular hook plates with different hook depths were very likely to result in over-reduction of the AC joint. It is necessary to bend the hook angle to fit the patient’s AC joint to achieve accurate reduction.</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Acromioclavicular joint</subfield><subfield code="7">(dpeaa)DE-He213</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Hook plate</subfield><subfield code="7">(dpeaa)DE-He213</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">3D printing</subfield><subfield code="7">(dpeaa)DE-He213</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Matching performance</subfield><subfield code="7">(dpeaa)DE-He213</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Wang, Gang</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Xia, Qingquan</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Rong, Ke</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Gan, Minfeng</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Wen, Gen</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Yin, Xiaofan</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Yang, Huilin</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="773" ind1="0" ind2="8"><subfield code="i">Enthalten in</subfield><subfield code="t">Indian journal of orthopaedics</subfield><subfield code="d">Varanasi : Assoc., 2004</subfield><subfield code="g">54(2020), 2 vom: 24. Jan., Seite 141-147</subfield><subfield code="w">(DE-627)531202356</subfield><subfield code="w">(DE-600)2323559-7</subfield><subfield code="x">1998-3727</subfield><subfield code="7">nnns</subfield></datafield><datafield tag="773" ind1="1" ind2="8"><subfield code="g">volume:54</subfield><subfield code="g">year:2020</subfield><subfield code="g">number:2</subfield><subfield code="g">day:24</subfield><subfield code="g">month:01</subfield><subfield code="g">pages:141-147</subfield></datafield><datafield tag="856" ind1="4" ind2="0"><subfield code="u">https://dx.doi.org/10.1007/s43465-019-00034-0</subfield><subfield code="z">lizenzpflichtig</subfield><subfield code="3">Volltext</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_USEFLAG_A</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">SYSFLAG_A</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_SPRINGER</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">SSG-OLC-PHA</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_11</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_20</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_22</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_23</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_24</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_31</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_32</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_39</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_40</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_60</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_62</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_63</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_65</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_69</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_70</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_73</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_74</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_90</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_95</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_100</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_101</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_105</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_110</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_138</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_150</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_151</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_152</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_161</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_170</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_171</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_187</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_206</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_213</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_224</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_230</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_250</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_281</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_285</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_293</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_370</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_602</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_636</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_702</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2001</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2003</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2004</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2005</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2006</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2007</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2008</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2009</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2010</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2011</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2014</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2015</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2020</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2021</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2025</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2026</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2027</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2031</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2034</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2037</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2038</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2039</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2044</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2048</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2049</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2050</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2055</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2056</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2057</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2059</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2061</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2064</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2065</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2068</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2088</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2093</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2106</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2107</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2108</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2110</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2111</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2112</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2113</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2118</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2122</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2129</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2143</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2144</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2147</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2148</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2152</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2153</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2190</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2232</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2336</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2446</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2470</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2472</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2507</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2522</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4012</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4035</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4037</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4046</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4112</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4125</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4126</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4242</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4246</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4249</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4251</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4305</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4306</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4307</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4313</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4322</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4323</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4324</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4325</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4326</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4328</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4333</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4334</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4335</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4336</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4338</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4367</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4393</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4700</subfield></datafield><datafield tag="951" ind1=" " ind2=" "><subfield code="a">AR</subfield></datafield><datafield tag="952" ind1=" " ind2=" "><subfield code="d">54</subfield><subfield code="j">2020</subfield><subfield code="e">2</subfield><subfield code="b">24</subfield><subfield code="c">01</subfield><subfield code="h">141-147</subfield></datafield></record></collection>
|
score |
7.400529 |