Efficacy and tolerability of a low-residue diet for bowel preparation: systematic review and meta-analysis
Background Colorectal cancer (CRC) contributes significantly to cancer mortality worldwide. In an effort to reduce the risk of death, detection of polyps through colonoscopy is crucial. The success of the colonoscopy depends on the diet administered the day before the test. Our aim was to evaluate t...
Ausführliche Beschreibung
Autor*in: |
Ahumada, Cristian [verfasserIn] |
---|
Format: |
E-Artikel |
---|---|
Sprache: |
Englisch |
Erschienen: |
2021 |
---|
Anmerkung: |
© The Author(s), under exclusive licence to Springer Science+Business Media, LLC, part of Springer Nature 2021 |
---|
Übergeordnetes Werk: |
Enthalten in: Surgical endoscopy and other interventional techniques - New York, NY : Springer, 1987, 36(2021), 6 vom: 01. Sept., Seite 3858-3875 |
---|---|
Übergeordnetes Werk: |
volume:36 ; year:2021 ; number:6 ; day:01 ; month:09 ; pages:3858-3875 |
Links: |
---|
DOI / URN: |
10.1007/s00464-021-08703-8 |
---|
Katalog-ID: |
SPR046949739 |
---|
LEADER | 01000caa a22002652 4500 | ||
---|---|---|---|
001 | SPR046949739 | ||
003 | DE-627 | ||
005 | 20230507175118.0 | ||
007 | cr uuu---uuuuu | ||
008 | 220510s2021 xx |||||o 00| ||eng c | ||
024 | 7 | |a 10.1007/s00464-021-08703-8 |2 doi | |
035 | |a (DE-627)SPR046949739 | ||
035 | |a (SPR)s00464-021-08703-8-e | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
100 | 1 | |a Ahumada, Cristian |e verfasserin |0 (orcid)0000-0002-4640-7856 |4 aut | |
245 | 1 | 0 | |a Efficacy and tolerability of a low-residue diet for bowel preparation: systematic review and meta-analysis |
264 | 1 | |c 2021 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a Computermedien |b c |2 rdamedia | ||
338 | |a Online-Ressource |b cr |2 rdacarrier | ||
500 | |a © The Author(s), under exclusive licence to Springer Science+Business Media, LLC, part of Springer Nature 2021 | ||
520 | |a Background Colorectal cancer (CRC) contributes significantly to cancer mortality worldwide. In an effort to reduce the risk of death, detection of polyps through colonoscopy is crucial. The success of the colonoscopy depends on the diet administered the day before the test. Our aim was to evaluate the efficacy, tolerability, and adverse effects of bowel preparation when using a low-residual diet (LRD) compared to a clear-liquid diet (CLD) the day before a scheduled colonoscopy. Methods PubMed/Medline, Embase, the Cochrane Central Register of Controlled Trials (CENTRAL) and Scopus databases were searched. We included studies of patients undergoing a scheduled colonoscopy for CRC screening and surveillance or for diagnostic purposes that compared a LRD with a CLD the day before the colonoscopy. Efficacy, the primary outcome, was evaluated as the rate of adequate bowel preparation. Secondary outcomes were tolerability and adverse effects of bowel preparation. Results Thirteen RCTs (N = 2587) were included. Patients receiving a LRD compared to a CLD showed no difference in adequate bowel preparations (RR 1.02; 95% CI 0.99–1.05; I2 = 60%). However, the LRD improved patient tolerability (RR 1.17; 95% CI 1.12–1.23; I2 = 66%) and had fewer adverse effects (RR 0.89; 95% CI 0.84–0.94; I2 = 73%) compared to the CLD. Groups using a LRD with 4L of polyethylene glycol in a single dose or a LRD with < 2000 kcal < 32 g of fibres/day had better tolerability. Conclusion Based on these findings, our recommendation is strong in favour of a LRD for bowel preparation of patients undergoing a scheduled colonoscopy. This diet could also be useful as a preoperative colonic preparation, but this requires further research. | ||
700 | 1 | |a Pereyra, Lisandro |4 aut | |
700 | 1 | |a Galvarini, Martín |4 aut | |
700 | 1 | |a Mella, José |4 aut | |
700 | 1 | |a Gómez, Estanislao |4 aut | |
700 | 1 | |a Pedreira, Silvia C. |4 aut | |
700 | 1 | |a Cimmino, Daniel G. |4 aut | |
773 | 0 | 8 | |i Enthalten in |t Surgical endoscopy and other interventional techniques |d New York, NY : Springer, 1987 |g 36(2021), 6 vom: 01. Sept., Seite 3858-3875 |w (DE-627)254909620 |w (DE-600)1463171-4 |x 1432-2218 |7 nnns |
773 | 1 | 8 | |g volume:36 |g year:2021 |g number:6 |g day:01 |g month:09 |g pages:3858-3875 |
856 | 4 | 0 | |u https://dx.doi.org/10.1007/s00464-021-08703-8 |z lizenzpflichtig |3 Volltext |
912 | |a GBV_USEFLAG_A | ||
912 | |a SYSFLAG_A | ||
912 | |a GBV_SPRINGER | ||
912 | |a GBV_ILN_11 | ||
912 | |a GBV_ILN_20 | ||
912 | |a GBV_ILN_22 | ||
912 | |a GBV_ILN_23 | ||
912 | |a GBV_ILN_24 | ||
912 | |a GBV_ILN_31 | ||
912 | |a GBV_ILN_32 | ||
912 | |a GBV_ILN_39 | ||
912 | |a GBV_ILN_40 | ||
912 | |a GBV_ILN_60 | ||
912 | |a GBV_ILN_62 | ||
912 | |a GBV_ILN_63 | ||
912 | |a GBV_ILN_69 | ||
912 | |a GBV_ILN_70 | ||
912 | |a GBV_ILN_73 | ||
912 | |a GBV_ILN_74 | ||
912 | |a GBV_ILN_90 | ||
912 | |a GBV_ILN_95 | ||
912 | |a GBV_ILN_100 | ||
912 | |a GBV_ILN_101 | ||
912 | |a GBV_ILN_105 | ||
912 | |a GBV_ILN_110 | ||
912 | |a GBV_ILN_120 | ||
912 | |a GBV_ILN_138 | ||
912 | |a GBV_ILN_150 | ||
912 | |a GBV_ILN_151 | ||
912 | |a GBV_ILN_152 | ||
912 | |a GBV_ILN_161 | ||
912 | |a GBV_ILN_170 | ||
912 | |a GBV_ILN_171 | ||
912 | |a GBV_ILN_187 | ||
912 | |a GBV_ILN_213 | ||
912 | |a GBV_ILN_224 | ||
912 | |a GBV_ILN_230 | ||
912 | |a GBV_ILN_250 | ||
912 | |a GBV_ILN_267 | ||
912 | |a GBV_ILN_281 | ||
912 | |a GBV_ILN_285 | ||
912 | |a GBV_ILN_293 | ||
912 | |a GBV_ILN_370 | ||
912 | |a GBV_ILN_602 | ||
912 | |a GBV_ILN_636 | ||
912 | |a GBV_ILN_702 | ||
912 | |a GBV_ILN_711 | ||
912 | |a GBV_ILN_2001 | ||
912 | |a GBV_ILN_2003 | ||
912 | |a GBV_ILN_2004 | ||
912 | |a GBV_ILN_2005 | ||
912 | |a GBV_ILN_2006 | ||
912 | |a GBV_ILN_2007 | ||
912 | |a GBV_ILN_2008 | ||
912 | |a GBV_ILN_2009 | ||
912 | |a GBV_ILN_2010 | ||
912 | |a GBV_ILN_2011 | ||
912 | |a GBV_ILN_2014 | ||
912 | |a GBV_ILN_2015 | ||
912 | |a GBV_ILN_2020 | ||
912 | |a GBV_ILN_2021 | ||
912 | |a GBV_ILN_2025 | ||
912 | |a GBV_ILN_2026 | ||
912 | |a GBV_ILN_2027 | ||
912 | |a GBV_ILN_2031 | ||
912 | |a GBV_ILN_2034 | ||
912 | |a GBV_ILN_2037 | ||
912 | |a GBV_ILN_2038 | ||
912 | |a GBV_ILN_2044 | ||
912 | |a GBV_ILN_2048 | ||
912 | |a GBV_ILN_2049 | ||
912 | |a GBV_ILN_2050 | ||
912 | |a GBV_ILN_2055 | ||
912 | |a GBV_ILN_2056 | ||
912 | |a GBV_ILN_2057 | ||
912 | |a GBV_ILN_2059 | ||
912 | |a GBV_ILN_2061 | ||
912 | |a GBV_ILN_2064 | ||
912 | |a GBV_ILN_2065 | ||
912 | |a GBV_ILN_2068 | ||
912 | |a GBV_ILN_2093 | ||
912 | |a GBV_ILN_2106 | ||
912 | |a GBV_ILN_2107 | ||
912 | |a GBV_ILN_2108 | ||
912 | |a GBV_ILN_2110 | ||
912 | |a GBV_ILN_2113 | ||
912 | |a GBV_ILN_2118 | ||
912 | |a GBV_ILN_2129 | ||
912 | |a GBV_ILN_2143 | ||
912 | |a GBV_ILN_2144 | ||
912 | |a GBV_ILN_2147 | ||
912 | |a GBV_ILN_2153 | ||
912 | |a GBV_ILN_2188 | ||
912 | |a GBV_ILN_2190 | ||
912 | |a GBV_ILN_2232 | ||
912 | |a GBV_ILN_2336 | ||
912 | |a GBV_ILN_2446 | ||
912 | |a GBV_ILN_2470 | ||
912 | |a GBV_ILN_2472 | ||
912 | |a GBV_ILN_2507 | ||
912 | |a GBV_ILN_2522 | ||
912 | |a GBV_ILN_2548 | ||
912 | |a GBV_ILN_4035 | ||
912 | |a GBV_ILN_4037 | ||
912 | |a GBV_ILN_4046 | ||
912 | |a GBV_ILN_4112 | ||
912 | |a GBV_ILN_4125 | ||
912 | |a GBV_ILN_4126 | ||
912 | |a GBV_ILN_4242 | ||
912 | |a GBV_ILN_4246 | ||
912 | |a GBV_ILN_4249 | ||
912 | |a GBV_ILN_4251 | ||
912 | |a GBV_ILN_4305 | ||
912 | |a GBV_ILN_4306 | ||
912 | |a GBV_ILN_4307 | ||
912 | |a GBV_ILN_4313 | ||
912 | |a GBV_ILN_4322 | ||
912 | |a GBV_ILN_4323 | ||
912 | |a GBV_ILN_4324 | ||
912 | |a GBV_ILN_4326 | ||
912 | |a GBV_ILN_4328 | ||
912 | |a GBV_ILN_4333 | ||
912 | |a GBV_ILN_4334 | ||
912 | |a GBV_ILN_4335 | ||
912 | |a GBV_ILN_4336 | ||
912 | |a GBV_ILN_4338 | ||
912 | |a GBV_ILN_4393 | ||
912 | |a GBV_ILN_4700 | ||
951 | |a AR | ||
952 | |d 36 |j 2021 |e 6 |b 01 |c 09 |h 3858-3875 |
author_variant |
c a ca l p lp m g mg j m jm e g eg s c p sc scp d g c dg dgc |
---|---|
matchkey_str |
article:14322218:2021----::fiayntlrbltoaorsdeitobwlrprtossea |
hierarchy_sort_str |
2021 |
publishDate |
2021 |
allfields |
10.1007/s00464-021-08703-8 doi (DE-627)SPR046949739 (SPR)s00464-021-08703-8-e DE-627 ger DE-627 rakwb eng Ahumada, Cristian verfasserin (orcid)0000-0002-4640-7856 aut Efficacy and tolerability of a low-residue diet for bowel preparation: systematic review and meta-analysis 2021 Text txt rdacontent Computermedien c rdamedia Online-Ressource cr rdacarrier © The Author(s), under exclusive licence to Springer Science+Business Media, LLC, part of Springer Nature 2021 Background Colorectal cancer (CRC) contributes significantly to cancer mortality worldwide. In an effort to reduce the risk of death, detection of polyps through colonoscopy is crucial. The success of the colonoscopy depends on the diet administered the day before the test. Our aim was to evaluate the efficacy, tolerability, and adverse effects of bowel preparation when using a low-residual diet (LRD) compared to a clear-liquid diet (CLD) the day before a scheduled colonoscopy. Methods PubMed/Medline, Embase, the Cochrane Central Register of Controlled Trials (CENTRAL) and Scopus databases were searched. We included studies of patients undergoing a scheduled colonoscopy for CRC screening and surveillance or for diagnostic purposes that compared a LRD with a CLD the day before the colonoscopy. Efficacy, the primary outcome, was evaluated as the rate of adequate bowel preparation. Secondary outcomes were tolerability and adverse effects of bowel preparation. Results Thirteen RCTs (N = 2587) were included. Patients receiving a LRD compared to a CLD showed no difference in adequate bowel preparations (RR 1.02; 95% CI 0.99–1.05; I2 = 60%). However, the LRD improved patient tolerability (RR 1.17; 95% CI 1.12–1.23; I2 = 66%) and had fewer adverse effects (RR 0.89; 95% CI 0.84–0.94; I2 = 73%) compared to the CLD. Groups using a LRD with 4L of polyethylene glycol in a single dose or a LRD with < 2000 kcal < 32 g of fibres/day had better tolerability. Conclusion Based on these findings, our recommendation is strong in favour of a LRD for bowel preparation of patients undergoing a scheduled colonoscopy. This diet could also be useful as a preoperative colonic preparation, but this requires further research. Pereyra, Lisandro aut Galvarini, Martín aut Mella, José aut Gómez, Estanislao aut Pedreira, Silvia C. aut Cimmino, Daniel G. aut Enthalten in Surgical endoscopy and other interventional techniques New York, NY : Springer, 1987 36(2021), 6 vom: 01. Sept., Seite 3858-3875 (DE-627)254909620 (DE-600)1463171-4 1432-2218 nnns volume:36 year:2021 number:6 day:01 month:09 pages:3858-3875 https://dx.doi.org/10.1007/s00464-021-08703-8 lizenzpflichtig Volltext GBV_USEFLAG_A SYSFLAG_A GBV_SPRINGER GBV_ILN_11 GBV_ILN_20 GBV_ILN_22 GBV_ILN_23 GBV_ILN_24 GBV_ILN_31 GBV_ILN_32 GBV_ILN_39 GBV_ILN_40 GBV_ILN_60 GBV_ILN_62 GBV_ILN_63 GBV_ILN_69 GBV_ILN_70 GBV_ILN_73 GBV_ILN_74 GBV_ILN_90 GBV_ILN_95 GBV_ILN_100 GBV_ILN_101 GBV_ILN_105 GBV_ILN_110 GBV_ILN_120 GBV_ILN_138 GBV_ILN_150 GBV_ILN_151 GBV_ILN_152 GBV_ILN_161 GBV_ILN_170 GBV_ILN_171 GBV_ILN_187 GBV_ILN_213 GBV_ILN_224 GBV_ILN_230 GBV_ILN_250 GBV_ILN_267 GBV_ILN_281 GBV_ILN_285 GBV_ILN_293 GBV_ILN_370 GBV_ILN_602 GBV_ILN_636 GBV_ILN_702 GBV_ILN_711 GBV_ILN_2001 GBV_ILN_2003 GBV_ILN_2004 GBV_ILN_2005 GBV_ILN_2006 GBV_ILN_2007 GBV_ILN_2008 GBV_ILN_2009 GBV_ILN_2010 GBV_ILN_2011 GBV_ILN_2014 GBV_ILN_2015 GBV_ILN_2020 GBV_ILN_2021 GBV_ILN_2025 GBV_ILN_2026 GBV_ILN_2027 GBV_ILN_2031 GBV_ILN_2034 GBV_ILN_2037 GBV_ILN_2038 GBV_ILN_2044 GBV_ILN_2048 GBV_ILN_2049 GBV_ILN_2050 GBV_ILN_2055 GBV_ILN_2056 GBV_ILN_2057 GBV_ILN_2059 GBV_ILN_2061 GBV_ILN_2064 GBV_ILN_2065 GBV_ILN_2068 GBV_ILN_2093 GBV_ILN_2106 GBV_ILN_2107 GBV_ILN_2108 GBV_ILN_2110 GBV_ILN_2113 GBV_ILN_2118 GBV_ILN_2129 GBV_ILN_2143 GBV_ILN_2144 GBV_ILN_2147 GBV_ILN_2153 GBV_ILN_2188 GBV_ILN_2190 GBV_ILN_2232 GBV_ILN_2336 GBV_ILN_2446 GBV_ILN_2470 GBV_ILN_2472 GBV_ILN_2507 GBV_ILN_2522 GBV_ILN_2548 GBV_ILN_4035 GBV_ILN_4037 GBV_ILN_4046 GBV_ILN_4112 GBV_ILN_4125 GBV_ILN_4126 GBV_ILN_4242 GBV_ILN_4246 GBV_ILN_4249 GBV_ILN_4251 GBV_ILN_4305 GBV_ILN_4306 GBV_ILN_4307 GBV_ILN_4313 GBV_ILN_4322 GBV_ILN_4323 GBV_ILN_4324 GBV_ILN_4326 GBV_ILN_4328 GBV_ILN_4333 GBV_ILN_4334 GBV_ILN_4335 GBV_ILN_4336 GBV_ILN_4338 GBV_ILN_4393 GBV_ILN_4700 AR 36 2021 6 01 09 3858-3875 |
spelling |
10.1007/s00464-021-08703-8 doi (DE-627)SPR046949739 (SPR)s00464-021-08703-8-e DE-627 ger DE-627 rakwb eng Ahumada, Cristian verfasserin (orcid)0000-0002-4640-7856 aut Efficacy and tolerability of a low-residue diet for bowel preparation: systematic review and meta-analysis 2021 Text txt rdacontent Computermedien c rdamedia Online-Ressource cr rdacarrier © The Author(s), under exclusive licence to Springer Science+Business Media, LLC, part of Springer Nature 2021 Background Colorectal cancer (CRC) contributes significantly to cancer mortality worldwide. In an effort to reduce the risk of death, detection of polyps through colonoscopy is crucial. The success of the colonoscopy depends on the diet administered the day before the test. Our aim was to evaluate the efficacy, tolerability, and adverse effects of bowel preparation when using a low-residual diet (LRD) compared to a clear-liquid diet (CLD) the day before a scheduled colonoscopy. Methods PubMed/Medline, Embase, the Cochrane Central Register of Controlled Trials (CENTRAL) and Scopus databases were searched. We included studies of patients undergoing a scheduled colonoscopy for CRC screening and surveillance or for diagnostic purposes that compared a LRD with a CLD the day before the colonoscopy. Efficacy, the primary outcome, was evaluated as the rate of adequate bowel preparation. Secondary outcomes were tolerability and adverse effects of bowel preparation. Results Thirteen RCTs (N = 2587) were included. Patients receiving a LRD compared to a CLD showed no difference in adequate bowel preparations (RR 1.02; 95% CI 0.99–1.05; I2 = 60%). However, the LRD improved patient tolerability (RR 1.17; 95% CI 1.12–1.23; I2 = 66%) and had fewer adverse effects (RR 0.89; 95% CI 0.84–0.94; I2 = 73%) compared to the CLD. Groups using a LRD with 4L of polyethylene glycol in a single dose or a LRD with < 2000 kcal < 32 g of fibres/day had better tolerability. Conclusion Based on these findings, our recommendation is strong in favour of a LRD for bowel preparation of patients undergoing a scheduled colonoscopy. This diet could also be useful as a preoperative colonic preparation, but this requires further research. Pereyra, Lisandro aut Galvarini, Martín aut Mella, José aut Gómez, Estanislao aut Pedreira, Silvia C. aut Cimmino, Daniel G. aut Enthalten in Surgical endoscopy and other interventional techniques New York, NY : Springer, 1987 36(2021), 6 vom: 01. Sept., Seite 3858-3875 (DE-627)254909620 (DE-600)1463171-4 1432-2218 nnns volume:36 year:2021 number:6 day:01 month:09 pages:3858-3875 https://dx.doi.org/10.1007/s00464-021-08703-8 lizenzpflichtig Volltext GBV_USEFLAG_A SYSFLAG_A GBV_SPRINGER GBV_ILN_11 GBV_ILN_20 GBV_ILN_22 GBV_ILN_23 GBV_ILN_24 GBV_ILN_31 GBV_ILN_32 GBV_ILN_39 GBV_ILN_40 GBV_ILN_60 GBV_ILN_62 GBV_ILN_63 GBV_ILN_69 GBV_ILN_70 GBV_ILN_73 GBV_ILN_74 GBV_ILN_90 GBV_ILN_95 GBV_ILN_100 GBV_ILN_101 GBV_ILN_105 GBV_ILN_110 GBV_ILN_120 GBV_ILN_138 GBV_ILN_150 GBV_ILN_151 GBV_ILN_152 GBV_ILN_161 GBV_ILN_170 GBV_ILN_171 GBV_ILN_187 GBV_ILN_213 GBV_ILN_224 GBV_ILN_230 GBV_ILN_250 GBV_ILN_267 GBV_ILN_281 GBV_ILN_285 GBV_ILN_293 GBV_ILN_370 GBV_ILN_602 GBV_ILN_636 GBV_ILN_702 GBV_ILN_711 GBV_ILN_2001 GBV_ILN_2003 GBV_ILN_2004 GBV_ILN_2005 GBV_ILN_2006 GBV_ILN_2007 GBV_ILN_2008 GBV_ILN_2009 GBV_ILN_2010 GBV_ILN_2011 GBV_ILN_2014 GBV_ILN_2015 GBV_ILN_2020 GBV_ILN_2021 GBV_ILN_2025 GBV_ILN_2026 GBV_ILN_2027 GBV_ILN_2031 GBV_ILN_2034 GBV_ILN_2037 GBV_ILN_2038 GBV_ILN_2044 GBV_ILN_2048 GBV_ILN_2049 GBV_ILN_2050 GBV_ILN_2055 GBV_ILN_2056 GBV_ILN_2057 GBV_ILN_2059 GBV_ILN_2061 GBV_ILN_2064 GBV_ILN_2065 GBV_ILN_2068 GBV_ILN_2093 GBV_ILN_2106 GBV_ILN_2107 GBV_ILN_2108 GBV_ILN_2110 GBV_ILN_2113 GBV_ILN_2118 GBV_ILN_2129 GBV_ILN_2143 GBV_ILN_2144 GBV_ILN_2147 GBV_ILN_2153 GBV_ILN_2188 GBV_ILN_2190 GBV_ILN_2232 GBV_ILN_2336 GBV_ILN_2446 GBV_ILN_2470 GBV_ILN_2472 GBV_ILN_2507 GBV_ILN_2522 GBV_ILN_2548 GBV_ILN_4035 GBV_ILN_4037 GBV_ILN_4046 GBV_ILN_4112 GBV_ILN_4125 GBV_ILN_4126 GBV_ILN_4242 GBV_ILN_4246 GBV_ILN_4249 GBV_ILN_4251 GBV_ILN_4305 GBV_ILN_4306 GBV_ILN_4307 GBV_ILN_4313 GBV_ILN_4322 GBV_ILN_4323 GBV_ILN_4324 GBV_ILN_4326 GBV_ILN_4328 GBV_ILN_4333 GBV_ILN_4334 GBV_ILN_4335 GBV_ILN_4336 GBV_ILN_4338 GBV_ILN_4393 GBV_ILN_4700 AR 36 2021 6 01 09 3858-3875 |
allfields_unstemmed |
10.1007/s00464-021-08703-8 doi (DE-627)SPR046949739 (SPR)s00464-021-08703-8-e DE-627 ger DE-627 rakwb eng Ahumada, Cristian verfasserin (orcid)0000-0002-4640-7856 aut Efficacy and tolerability of a low-residue diet for bowel preparation: systematic review and meta-analysis 2021 Text txt rdacontent Computermedien c rdamedia Online-Ressource cr rdacarrier © The Author(s), under exclusive licence to Springer Science+Business Media, LLC, part of Springer Nature 2021 Background Colorectal cancer (CRC) contributes significantly to cancer mortality worldwide. In an effort to reduce the risk of death, detection of polyps through colonoscopy is crucial. The success of the colonoscopy depends on the diet administered the day before the test. Our aim was to evaluate the efficacy, tolerability, and adverse effects of bowel preparation when using a low-residual diet (LRD) compared to a clear-liquid diet (CLD) the day before a scheduled colonoscopy. Methods PubMed/Medline, Embase, the Cochrane Central Register of Controlled Trials (CENTRAL) and Scopus databases were searched. We included studies of patients undergoing a scheduled colonoscopy for CRC screening and surveillance or for diagnostic purposes that compared a LRD with a CLD the day before the colonoscopy. Efficacy, the primary outcome, was evaluated as the rate of adequate bowel preparation. Secondary outcomes were tolerability and adverse effects of bowel preparation. Results Thirteen RCTs (N = 2587) were included. Patients receiving a LRD compared to a CLD showed no difference in adequate bowel preparations (RR 1.02; 95% CI 0.99–1.05; I2 = 60%). However, the LRD improved patient tolerability (RR 1.17; 95% CI 1.12–1.23; I2 = 66%) and had fewer adverse effects (RR 0.89; 95% CI 0.84–0.94; I2 = 73%) compared to the CLD. Groups using a LRD with 4L of polyethylene glycol in a single dose or a LRD with < 2000 kcal < 32 g of fibres/day had better tolerability. Conclusion Based on these findings, our recommendation is strong in favour of a LRD for bowel preparation of patients undergoing a scheduled colonoscopy. This diet could also be useful as a preoperative colonic preparation, but this requires further research. Pereyra, Lisandro aut Galvarini, Martín aut Mella, José aut Gómez, Estanislao aut Pedreira, Silvia C. aut Cimmino, Daniel G. aut Enthalten in Surgical endoscopy and other interventional techniques New York, NY : Springer, 1987 36(2021), 6 vom: 01. Sept., Seite 3858-3875 (DE-627)254909620 (DE-600)1463171-4 1432-2218 nnns volume:36 year:2021 number:6 day:01 month:09 pages:3858-3875 https://dx.doi.org/10.1007/s00464-021-08703-8 lizenzpflichtig Volltext GBV_USEFLAG_A SYSFLAG_A GBV_SPRINGER GBV_ILN_11 GBV_ILN_20 GBV_ILN_22 GBV_ILN_23 GBV_ILN_24 GBV_ILN_31 GBV_ILN_32 GBV_ILN_39 GBV_ILN_40 GBV_ILN_60 GBV_ILN_62 GBV_ILN_63 GBV_ILN_69 GBV_ILN_70 GBV_ILN_73 GBV_ILN_74 GBV_ILN_90 GBV_ILN_95 GBV_ILN_100 GBV_ILN_101 GBV_ILN_105 GBV_ILN_110 GBV_ILN_120 GBV_ILN_138 GBV_ILN_150 GBV_ILN_151 GBV_ILN_152 GBV_ILN_161 GBV_ILN_170 GBV_ILN_171 GBV_ILN_187 GBV_ILN_213 GBV_ILN_224 GBV_ILN_230 GBV_ILN_250 GBV_ILN_267 GBV_ILN_281 GBV_ILN_285 GBV_ILN_293 GBV_ILN_370 GBV_ILN_602 GBV_ILN_636 GBV_ILN_702 GBV_ILN_711 GBV_ILN_2001 GBV_ILN_2003 GBV_ILN_2004 GBV_ILN_2005 GBV_ILN_2006 GBV_ILN_2007 GBV_ILN_2008 GBV_ILN_2009 GBV_ILN_2010 GBV_ILN_2011 GBV_ILN_2014 GBV_ILN_2015 GBV_ILN_2020 GBV_ILN_2021 GBV_ILN_2025 GBV_ILN_2026 GBV_ILN_2027 GBV_ILN_2031 GBV_ILN_2034 GBV_ILN_2037 GBV_ILN_2038 GBV_ILN_2044 GBV_ILN_2048 GBV_ILN_2049 GBV_ILN_2050 GBV_ILN_2055 GBV_ILN_2056 GBV_ILN_2057 GBV_ILN_2059 GBV_ILN_2061 GBV_ILN_2064 GBV_ILN_2065 GBV_ILN_2068 GBV_ILN_2093 GBV_ILN_2106 GBV_ILN_2107 GBV_ILN_2108 GBV_ILN_2110 GBV_ILN_2113 GBV_ILN_2118 GBV_ILN_2129 GBV_ILN_2143 GBV_ILN_2144 GBV_ILN_2147 GBV_ILN_2153 GBV_ILN_2188 GBV_ILN_2190 GBV_ILN_2232 GBV_ILN_2336 GBV_ILN_2446 GBV_ILN_2470 GBV_ILN_2472 GBV_ILN_2507 GBV_ILN_2522 GBV_ILN_2548 GBV_ILN_4035 GBV_ILN_4037 GBV_ILN_4046 GBV_ILN_4112 GBV_ILN_4125 GBV_ILN_4126 GBV_ILN_4242 GBV_ILN_4246 GBV_ILN_4249 GBV_ILN_4251 GBV_ILN_4305 GBV_ILN_4306 GBV_ILN_4307 GBV_ILN_4313 GBV_ILN_4322 GBV_ILN_4323 GBV_ILN_4324 GBV_ILN_4326 GBV_ILN_4328 GBV_ILN_4333 GBV_ILN_4334 GBV_ILN_4335 GBV_ILN_4336 GBV_ILN_4338 GBV_ILN_4393 GBV_ILN_4700 AR 36 2021 6 01 09 3858-3875 |
allfieldsGer |
10.1007/s00464-021-08703-8 doi (DE-627)SPR046949739 (SPR)s00464-021-08703-8-e DE-627 ger DE-627 rakwb eng Ahumada, Cristian verfasserin (orcid)0000-0002-4640-7856 aut Efficacy and tolerability of a low-residue diet for bowel preparation: systematic review and meta-analysis 2021 Text txt rdacontent Computermedien c rdamedia Online-Ressource cr rdacarrier © The Author(s), under exclusive licence to Springer Science+Business Media, LLC, part of Springer Nature 2021 Background Colorectal cancer (CRC) contributes significantly to cancer mortality worldwide. In an effort to reduce the risk of death, detection of polyps through colonoscopy is crucial. The success of the colonoscopy depends on the diet administered the day before the test. Our aim was to evaluate the efficacy, tolerability, and adverse effects of bowel preparation when using a low-residual diet (LRD) compared to a clear-liquid diet (CLD) the day before a scheduled colonoscopy. Methods PubMed/Medline, Embase, the Cochrane Central Register of Controlled Trials (CENTRAL) and Scopus databases were searched. We included studies of patients undergoing a scheduled colonoscopy for CRC screening and surveillance or for diagnostic purposes that compared a LRD with a CLD the day before the colonoscopy. Efficacy, the primary outcome, was evaluated as the rate of adequate bowel preparation. Secondary outcomes were tolerability and adverse effects of bowel preparation. Results Thirteen RCTs (N = 2587) were included. Patients receiving a LRD compared to a CLD showed no difference in adequate bowel preparations (RR 1.02; 95% CI 0.99–1.05; I2 = 60%). However, the LRD improved patient tolerability (RR 1.17; 95% CI 1.12–1.23; I2 = 66%) and had fewer adverse effects (RR 0.89; 95% CI 0.84–0.94; I2 = 73%) compared to the CLD. Groups using a LRD with 4L of polyethylene glycol in a single dose or a LRD with < 2000 kcal < 32 g of fibres/day had better tolerability. Conclusion Based on these findings, our recommendation is strong in favour of a LRD for bowel preparation of patients undergoing a scheduled colonoscopy. This diet could also be useful as a preoperative colonic preparation, but this requires further research. Pereyra, Lisandro aut Galvarini, Martín aut Mella, José aut Gómez, Estanislao aut Pedreira, Silvia C. aut Cimmino, Daniel G. aut Enthalten in Surgical endoscopy and other interventional techniques New York, NY : Springer, 1987 36(2021), 6 vom: 01. Sept., Seite 3858-3875 (DE-627)254909620 (DE-600)1463171-4 1432-2218 nnns volume:36 year:2021 number:6 day:01 month:09 pages:3858-3875 https://dx.doi.org/10.1007/s00464-021-08703-8 lizenzpflichtig Volltext GBV_USEFLAG_A SYSFLAG_A GBV_SPRINGER GBV_ILN_11 GBV_ILN_20 GBV_ILN_22 GBV_ILN_23 GBV_ILN_24 GBV_ILN_31 GBV_ILN_32 GBV_ILN_39 GBV_ILN_40 GBV_ILN_60 GBV_ILN_62 GBV_ILN_63 GBV_ILN_69 GBV_ILN_70 GBV_ILN_73 GBV_ILN_74 GBV_ILN_90 GBV_ILN_95 GBV_ILN_100 GBV_ILN_101 GBV_ILN_105 GBV_ILN_110 GBV_ILN_120 GBV_ILN_138 GBV_ILN_150 GBV_ILN_151 GBV_ILN_152 GBV_ILN_161 GBV_ILN_170 GBV_ILN_171 GBV_ILN_187 GBV_ILN_213 GBV_ILN_224 GBV_ILN_230 GBV_ILN_250 GBV_ILN_267 GBV_ILN_281 GBV_ILN_285 GBV_ILN_293 GBV_ILN_370 GBV_ILN_602 GBV_ILN_636 GBV_ILN_702 GBV_ILN_711 GBV_ILN_2001 GBV_ILN_2003 GBV_ILN_2004 GBV_ILN_2005 GBV_ILN_2006 GBV_ILN_2007 GBV_ILN_2008 GBV_ILN_2009 GBV_ILN_2010 GBV_ILN_2011 GBV_ILN_2014 GBV_ILN_2015 GBV_ILN_2020 GBV_ILN_2021 GBV_ILN_2025 GBV_ILN_2026 GBV_ILN_2027 GBV_ILN_2031 GBV_ILN_2034 GBV_ILN_2037 GBV_ILN_2038 GBV_ILN_2044 GBV_ILN_2048 GBV_ILN_2049 GBV_ILN_2050 GBV_ILN_2055 GBV_ILN_2056 GBV_ILN_2057 GBV_ILN_2059 GBV_ILN_2061 GBV_ILN_2064 GBV_ILN_2065 GBV_ILN_2068 GBV_ILN_2093 GBV_ILN_2106 GBV_ILN_2107 GBV_ILN_2108 GBV_ILN_2110 GBV_ILN_2113 GBV_ILN_2118 GBV_ILN_2129 GBV_ILN_2143 GBV_ILN_2144 GBV_ILN_2147 GBV_ILN_2153 GBV_ILN_2188 GBV_ILN_2190 GBV_ILN_2232 GBV_ILN_2336 GBV_ILN_2446 GBV_ILN_2470 GBV_ILN_2472 GBV_ILN_2507 GBV_ILN_2522 GBV_ILN_2548 GBV_ILN_4035 GBV_ILN_4037 GBV_ILN_4046 GBV_ILN_4112 GBV_ILN_4125 GBV_ILN_4126 GBV_ILN_4242 GBV_ILN_4246 GBV_ILN_4249 GBV_ILN_4251 GBV_ILN_4305 GBV_ILN_4306 GBV_ILN_4307 GBV_ILN_4313 GBV_ILN_4322 GBV_ILN_4323 GBV_ILN_4324 GBV_ILN_4326 GBV_ILN_4328 GBV_ILN_4333 GBV_ILN_4334 GBV_ILN_4335 GBV_ILN_4336 GBV_ILN_4338 GBV_ILN_4393 GBV_ILN_4700 AR 36 2021 6 01 09 3858-3875 |
allfieldsSound |
10.1007/s00464-021-08703-8 doi (DE-627)SPR046949739 (SPR)s00464-021-08703-8-e DE-627 ger DE-627 rakwb eng Ahumada, Cristian verfasserin (orcid)0000-0002-4640-7856 aut Efficacy and tolerability of a low-residue diet for bowel preparation: systematic review and meta-analysis 2021 Text txt rdacontent Computermedien c rdamedia Online-Ressource cr rdacarrier © The Author(s), under exclusive licence to Springer Science+Business Media, LLC, part of Springer Nature 2021 Background Colorectal cancer (CRC) contributes significantly to cancer mortality worldwide. In an effort to reduce the risk of death, detection of polyps through colonoscopy is crucial. The success of the colonoscopy depends on the diet administered the day before the test. Our aim was to evaluate the efficacy, tolerability, and adverse effects of bowel preparation when using a low-residual diet (LRD) compared to a clear-liquid diet (CLD) the day before a scheduled colonoscopy. Methods PubMed/Medline, Embase, the Cochrane Central Register of Controlled Trials (CENTRAL) and Scopus databases were searched. We included studies of patients undergoing a scheduled colonoscopy for CRC screening and surveillance or for diagnostic purposes that compared a LRD with a CLD the day before the colonoscopy. Efficacy, the primary outcome, was evaluated as the rate of adequate bowel preparation. Secondary outcomes were tolerability and adverse effects of bowel preparation. Results Thirteen RCTs (N = 2587) were included. Patients receiving a LRD compared to a CLD showed no difference in adequate bowel preparations (RR 1.02; 95% CI 0.99–1.05; I2 = 60%). However, the LRD improved patient tolerability (RR 1.17; 95% CI 1.12–1.23; I2 = 66%) and had fewer adverse effects (RR 0.89; 95% CI 0.84–0.94; I2 = 73%) compared to the CLD. Groups using a LRD with 4L of polyethylene glycol in a single dose or a LRD with < 2000 kcal < 32 g of fibres/day had better tolerability. Conclusion Based on these findings, our recommendation is strong in favour of a LRD for bowel preparation of patients undergoing a scheduled colonoscopy. This diet could also be useful as a preoperative colonic preparation, but this requires further research. Pereyra, Lisandro aut Galvarini, Martín aut Mella, José aut Gómez, Estanislao aut Pedreira, Silvia C. aut Cimmino, Daniel G. aut Enthalten in Surgical endoscopy and other interventional techniques New York, NY : Springer, 1987 36(2021), 6 vom: 01. Sept., Seite 3858-3875 (DE-627)254909620 (DE-600)1463171-4 1432-2218 nnns volume:36 year:2021 number:6 day:01 month:09 pages:3858-3875 https://dx.doi.org/10.1007/s00464-021-08703-8 lizenzpflichtig Volltext GBV_USEFLAG_A SYSFLAG_A GBV_SPRINGER GBV_ILN_11 GBV_ILN_20 GBV_ILN_22 GBV_ILN_23 GBV_ILN_24 GBV_ILN_31 GBV_ILN_32 GBV_ILN_39 GBV_ILN_40 GBV_ILN_60 GBV_ILN_62 GBV_ILN_63 GBV_ILN_69 GBV_ILN_70 GBV_ILN_73 GBV_ILN_74 GBV_ILN_90 GBV_ILN_95 GBV_ILN_100 GBV_ILN_101 GBV_ILN_105 GBV_ILN_110 GBV_ILN_120 GBV_ILN_138 GBV_ILN_150 GBV_ILN_151 GBV_ILN_152 GBV_ILN_161 GBV_ILN_170 GBV_ILN_171 GBV_ILN_187 GBV_ILN_213 GBV_ILN_224 GBV_ILN_230 GBV_ILN_250 GBV_ILN_267 GBV_ILN_281 GBV_ILN_285 GBV_ILN_293 GBV_ILN_370 GBV_ILN_602 GBV_ILN_636 GBV_ILN_702 GBV_ILN_711 GBV_ILN_2001 GBV_ILN_2003 GBV_ILN_2004 GBV_ILN_2005 GBV_ILN_2006 GBV_ILN_2007 GBV_ILN_2008 GBV_ILN_2009 GBV_ILN_2010 GBV_ILN_2011 GBV_ILN_2014 GBV_ILN_2015 GBV_ILN_2020 GBV_ILN_2021 GBV_ILN_2025 GBV_ILN_2026 GBV_ILN_2027 GBV_ILN_2031 GBV_ILN_2034 GBV_ILN_2037 GBV_ILN_2038 GBV_ILN_2044 GBV_ILN_2048 GBV_ILN_2049 GBV_ILN_2050 GBV_ILN_2055 GBV_ILN_2056 GBV_ILN_2057 GBV_ILN_2059 GBV_ILN_2061 GBV_ILN_2064 GBV_ILN_2065 GBV_ILN_2068 GBV_ILN_2093 GBV_ILN_2106 GBV_ILN_2107 GBV_ILN_2108 GBV_ILN_2110 GBV_ILN_2113 GBV_ILN_2118 GBV_ILN_2129 GBV_ILN_2143 GBV_ILN_2144 GBV_ILN_2147 GBV_ILN_2153 GBV_ILN_2188 GBV_ILN_2190 GBV_ILN_2232 GBV_ILN_2336 GBV_ILN_2446 GBV_ILN_2470 GBV_ILN_2472 GBV_ILN_2507 GBV_ILN_2522 GBV_ILN_2548 GBV_ILN_4035 GBV_ILN_4037 GBV_ILN_4046 GBV_ILN_4112 GBV_ILN_4125 GBV_ILN_4126 GBV_ILN_4242 GBV_ILN_4246 GBV_ILN_4249 GBV_ILN_4251 GBV_ILN_4305 GBV_ILN_4306 GBV_ILN_4307 GBV_ILN_4313 GBV_ILN_4322 GBV_ILN_4323 GBV_ILN_4324 GBV_ILN_4326 GBV_ILN_4328 GBV_ILN_4333 GBV_ILN_4334 GBV_ILN_4335 GBV_ILN_4336 GBV_ILN_4338 GBV_ILN_4393 GBV_ILN_4700 AR 36 2021 6 01 09 3858-3875 |
language |
English |
source |
Enthalten in Surgical endoscopy and other interventional techniques 36(2021), 6 vom: 01. Sept., Seite 3858-3875 volume:36 year:2021 number:6 day:01 month:09 pages:3858-3875 |
sourceStr |
Enthalten in Surgical endoscopy and other interventional techniques 36(2021), 6 vom: 01. Sept., Seite 3858-3875 volume:36 year:2021 number:6 day:01 month:09 pages:3858-3875 |
format_phy_str_mv |
Article |
institution |
findex.gbv.de |
isfreeaccess_bool |
false |
container_title |
Surgical endoscopy and other interventional techniques |
authorswithroles_txt_mv |
Ahumada, Cristian @@aut@@ Pereyra, Lisandro @@aut@@ Galvarini, Martín @@aut@@ Mella, José @@aut@@ Gómez, Estanislao @@aut@@ Pedreira, Silvia C. @@aut@@ Cimmino, Daniel G. @@aut@@ |
publishDateDaySort_date |
2021-09-01T00:00:00Z |
hierarchy_top_id |
254909620 |
id |
SPR046949739 |
language_de |
englisch |
fullrecord |
<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim"><record><leader>01000caa a22002652 4500</leader><controlfield tag="001">SPR046949739</controlfield><controlfield tag="003">DE-627</controlfield><controlfield tag="005">20230507175118.0</controlfield><controlfield tag="007">cr uuu---uuuuu</controlfield><controlfield tag="008">220510s2021 xx |||||o 00| ||eng c</controlfield><datafield tag="024" ind1="7" ind2=" "><subfield code="a">10.1007/s00464-021-08703-8</subfield><subfield code="2">doi</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-627)SPR046949739</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(SPR)s00464-021-08703-8-e</subfield></datafield><datafield tag="040" ind1=" " ind2=" "><subfield code="a">DE-627</subfield><subfield code="b">ger</subfield><subfield code="c">DE-627</subfield><subfield code="e">rakwb</subfield></datafield><datafield tag="041" ind1=" " ind2=" "><subfield code="a">eng</subfield></datafield><datafield tag="100" ind1="1" ind2=" "><subfield code="a">Ahumada, Cristian</subfield><subfield code="e">verfasserin</subfield><subfield code="0">(orcid)0000-0002-4640-7856</subfield><subfield code="4">aut</subfield></datafield><datafield tag="245" ind1="1" ind2="0"><subfield code="a">Efficacy and tolerability of a low-residue diet for bowel preparation: systematic review and meta-analysis</subfield></datafield><datafield tag="264" ind1=" " ind2="1"><subfield code="c">2021</subfield></datafield><datafield tag="336" ind1=" " ind2=" "><subfield code="a">Text</subfield><subfield code="b">txt</subfield><subfield code="2">rdacontent</subfield></datafield><datafield tag="337" ind1=" " ind2=" "><subfield code="a">Computermedien</subfield><subfield code="b">c</subfield><subfield code="2">rdamedia</subfield></datafield><datafield tag="338" ind1=" " ind2=" "><subfield code="a">Online-Ressource</subfield><subfield code="b">cr</subfield><subfield code="2">rdacarrier</subfield></datafield><datafield tag="500" ind1=" " ind2=" "><subfield code="a">© The Author(s), under exclusive licence to Springer Science+Business Media, LLC, part of Springer Nature 2021</subfield></datafield><datafield tag="520" ind1=" " ind2=" "><subfield code="a">Background Colorectal cancer (CRC) contributes significantly to cancer mortality worldwide. In an effort to reduce the risk of death, detection of polyps through colonoscopy is crucial. The success of the colonoscopy depends on the diet administered the day before the test. Our aim was to evaluate the efficacy, tolerability, and adverse effects of bowel preparation when using a low-residual diet (LRD) compared to a clear-liquid diet (CLD) the day before a scheduled colonoscopy. Methods PubMed/Medline, Embase, the Cochrane Central Register of Controlled Trials (CENTRAL) and Scopus databases were searched. We included studies of patients undergoing a scheduled colonoscopy for CRC screening and surveillance or for diagnostic purposes that compared a LRD with a CLD the day before the colonoscopy. Efficacy, the primary outcome, was evaluated as the rate of adequate bowel preparation. Secondary outcomes were tolerability and adverse effects of bowel preparation. Results Thirteen RCTs (N = 2587) were included. Patients receiving a LRD compared to a CLD showed no difference in adequate bowel preparations (RR 1.02; 95% CI 0.99–1.05; I2 = 60%). However, the LRD improved patient tolerability (RR 1.17; 95% CI 1.12–1.23; I2 = 66%) and had fewer adverse effects (RR 0.89; 95% CI 0.84–0.94; I2 = 73%) compared to the CLD. Groups using a LRD with 4L of polyethylene glycol in a single dose or a LRD with < 2000 kcal < 32 g of fibres/day had better tolerability. Conclusion Based on these findings, our recommendation is strong in favour of a LRD for bowel preparation of patients undergoing a scheduled colonoscopy. This diet could also be useful as a preoperative colonic preparation, but this requires further research.</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Pereyra, Lisandro</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Galvarini, Martín</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Mella, José</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Gómez, Estanislao</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Pedreira, Silvia C.</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Cimmino, Daniel G.</subfield><subfield code="4">aut</subfield></datafield><datafield tag="773" ind1="0" ind2="8"><subfield code="i">Enthalten in</subfield><subfield code="t">Surgical endoscopy and other interventional techniques</subfield><subfield code="d">New York, NY : Springer, 1987</subfield><subfield code="g">36(2021), 6 vom: 01. Sept., Seite 3858-3875</subfield><subfield code="w">(DE-627)254909620</subfield><subfield code="w">(DE-600)1463171-4</subfield><subfield code="x">1432-2218</subfield><subfield code="7">nnns</subfield></datafield><datafield tag="773" ind1="1" ind2="8"><subfield code="g">volume:36</subfield><subfield code="g">year:2021</subfield><subfield code="g">number:6</subfield><subfield code="g">day:01</subfield><subfield code="g">month:09</subfield><subfield code="g">pages:3858-3875</subfield></datafield><datafield tag="856" ind1="4" ind2="0"><subfield code="u">https://dx.doi.org/10.1007/s00464-021-08703-8</subfield><subfield code="z">lizenzpflichtig</subfield><subfield code="3">Volltext</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_USEFLAG_A</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">SYSFLAG_A</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_SPRINGER</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_11</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_20</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_22</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_23</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_24</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_31</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_32</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_39</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_40</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_60</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_62</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_63</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_69</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_70</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_73</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_74</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_90</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_95</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_100</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_101</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_105</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_110</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_120</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_138</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_150</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_151</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_152</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_161</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_170</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_171</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_187</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_213</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_224</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_230</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_250</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_267</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_281</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_285</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_293</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_370</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_602</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_636</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_702</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_711</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2001</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2003</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2004</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2005</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2006</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2007</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2008</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2009</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2010</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2011</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2014</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2015</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2020</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2021</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2025</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2026</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2027</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2031</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2034</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2037</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2038</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2044</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2048</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2049</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2050</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2055</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2056</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2057</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2059</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2061</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2064</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2065</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2068</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2093</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2106</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2107</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2108</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2110</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2113</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2118</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2129</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2143</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2144</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2147</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2153</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2188</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2190</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2232</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2336</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2446</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2470</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2472</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2507</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2522</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2548</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4035</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4037</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4046</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4112</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4125</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4126</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4242</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4246</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4249</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4251</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4305</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4306</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4307</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4313</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4322</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4323</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4324</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4326</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4328</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4333</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4334</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4335</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4336</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4338</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4393</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4700</subfield></datafield><datafield tag="951" ind1=" " ind2=" "><subfield code="a">AR</subfield></datafield><datafield tag="952" ind1=" " ind2=" "><subfield code="d">36</subfield><subfield code="j">2021</subfield><subfield code="e">6</subfield><subfield code="b">01</subfield><subfield code="c">09</subfield><subfield code="h">3858-3875</subfield></datafield></record></collection>
|
author |
Ahumada, Cristian |
spellingShingle |
Ahumada, Cristian Efficacy and tolerability of a low-residue diet for bowel preparation: systematic review and meta-analysis |
authorStr |
Ahumada, Cristian |
ppnlink_with_tag_str_mv |
@@773@@(DE-627)254909620 |
format |
electronic Article |
delete_txt_mv |
keep |
author_role |
aut aut aut aut aut aut aut |
collection |
springer |
remote_str |
true |
illustrated |
Not Illustrated |
issn |
1432-2218 |
topic_title |
Efficacy and tolerability of a low-residue diet for bowel preparation: systematic review and meta-analysis |
format_facet |
Elektronische Aufsätze Aufsätze Elektronische Ressource |
format_main_str_mv |
Text Zeitschrift/Artikel |
carriertype_str_mv |
cr |
hierarchy_parent_title |
Surgical endoscopy and other interventional techniques |
hierarchy_parent_id |
254909620 |
hierarchy_top_title |
Surgical endoscopy and other interventional techniques |
isfreeaccess_txt |
false |
familylinks_str_mv |
(DE-627)254909620 (DE-600)1463171-4 |
title |
Efficacy and tolerability of a low-residue diet for bowel preparation: systematic review and meta-analysis |
ctrlnum |
(DE-627)SPR046949739 (SPR)s00464-021-08703-8-e |
title_full |
Efficacy and tolerability of a low-residue diet for bowel preparation: systematic review and meta-analysis |
author_sort |
Ahumada, Cristian |
journal |
Surgical endoscopy and other interventional techniques |
journalStr |
Surgical endoscopy and other interventional techniques |
lang_code |
eng |
isOA_bool |
false |
recordtype |
marc |
publishDateSort |
2021 |
contenttype_str_mv |
txt |
container_start_page |
3858 |
author_browse |
Ahumada, Cristian Pereyra, Lisandro Galvarini, Martín Mella, José Gómez, Estanislao Pedreira, Silvia C. Cimmino, Daniel G. |
container_volume |
36 |
format_se |
Elektronische Aufsätze |
author-letter |
Ahumada, Cristian |
doi_str_mv |
10.1007/s00464-021-08703-8 |
normlink |
(ORCID)0000-0002-4640-7856 |
normlink_prefix_str_mv |
(orcid)0000-0002-4640-7856 |
title_sort |
efficacy and tolerability of a low-residue diet for bowel preparation: systematic review and meta-analysis |
title_auth |
Efficacy and tolerability of a low-residue diet for bowel preparation: systematic review and meta-analysis |
abstract |
Background Colorectal cancer (CRC) contributes significantly to cancer mortality worldwide. In an effort to reduce the risk of death, detection of polyps through colonoscopy is crucial. The success of the colonoscopy depends on the diet administered the day before the test. Our aim was to evaluate the efficacy, tolerability, and adverse effects of bowel preparation when using a low-residual diet (LRD) compared to a clear-liquid diet (CLD) the day before a scheduled colonoscopy. Methods PubMed/Medline, Embase, the Cochrane Central Register of Controlled Trials (CENTRAL) and Scopus databases were searched. We included studies of patients undergoing a scheduled colonoscopy for CRC screening and surveillance or for diagnostic purposes that compared a LRD with a CLD the day before the colonoscopy. Efficacy, the primary outcome, was evaluated as the rate of adequate bowel preparation. Secondary outcomes were tolerability and adverse effects of bowel preparation. Results Thirteen RCTs (N = 2587) were included. Patients receiving a LRD compared to a CLD showed no difference in adequate bowel preparations (RR 1.02; 95% CI 0.99–1.05; I2 = 60%). However, the LRD improved patient tolerability (RR 1.17; 95% CI 1.12–1.23; I2 = 66%) and had fewer adverse effects (RR 0.89; 95% CI 0.84–0.94; I2 = 73%) compared to the CLD. Groups using a LRD with 4L of polyethylene glycol in a single dose or a LRD with < 2000 kcal < 32 g of fibres/day had better tolerability. Conclusion Based on these findings, our recommendation is strong in favour of a LRD for bowel preparation of patients undergoing a scheduled colonoscopy. This diet could also be useful as a preoperative colonic preparation, but this requires further research. © The Author(s), under exclusive licence to Springer Science+Business Media, LLC, part of Springer Nature 2021 |
abstractGer |
Background Colorectal cancer (CRC) contributes significantly to cancer mortality worldwide. In an effort to reduce the risk of death, detection of polyps through colonoscopy is crucial. The success of the colonoscopy depends on the diet administered the day before the test. Our aim was to evaluate the efficacy, tolerability, and adverse effects of bowel preparation when using a low-residual diet (LRD) compared to a clear-liquid diet (CLD) the day before a scheduled colonoscopy. Methods PubMed/Medline, Embase, the Cochrane Central Register of Controlled Trials (CENTRAL) and Scopus databases were searched. We included studies of patients undergoing a scheduled colonoscopy for CRC screening and surveillance or for diagnostic purposes that compared a LRD with a CLD the day before the colonoscopy. Efficacy, the primary outcome, was evaluated as the rate of adequate bowel preparation. Secondary outcomes were tolerability and adverse effects of bowel preparation. Results Thirteen RCTs (N = 2587) were included. Patients receiving a LRD compared to a CLD showed no difference in adequate bowel preparations (RR 1.02; 95% CI 0.99–1.05; I2 = 60%). However, the LRD improved patient tolerability (RR 1.17; 95% CI 1.12–1.23; I2 = 66%) and had fewer adverse effects (RR 0.89; 95% CI 0.84–0.94; I2 = 73%) compared to the CLD. Groups using a LRD with 4L of polyethylene glycol in a single dose or a LRD with < 2000 kcal < 32 g of fibres/day had better tolerability. Conclusion Based on these findings, our recommendation is strong in favour of a LRD for bowel preparation of patients undergoing a scheduled colonoscopy. This diet could also be useful as a preoperative colonic preparation, but this requires further research. © The Author(s), under exclusive licence to Springer Science+Business Media, LLC, part of Springer Nature 2021 |
abstract_unstemmed |
Background Colorectal cancer (CRC) contributes significantly to cancer mortality worldwide. In an effort to reduce the risk of death, detection of polyps through colonoscopy is crucial. The success of the colonoscopy depends on the diet administered the day before the test. Our aim was to evaluate the efficacy, tolerability, and adverse effects of bowel preparation when using a low-residual diet (LRD) compared to a clear-liquid diet (CLD) the day before a scheduled colonoscopy. Methods PubMed/Medline, Embase, the Cochrane Central Register of Controlled Trials (CENTRAL) and Scopus databases were searched. We included studies of patients undergoing a scheduled colonoscopy for CRC screening and surveillance or for diagnostic purposes that compared a LRD with a CLD the day before the colonoscopy. Efficacy, the primary outcome, was evaluated as the rate of adequate bowel preparation. Secondary outcomes were tolerability and adverse effects of bowel preparation. Results Thirteen RCTs (N = 2587) were included. Patients receiving a LRD compared to a CLD showed no difference in adequate bowel preparations (RR 1.02; 95% CI 0.99–1.05; I2 = 60%). However, the LRD improved patient tolerability (RR 1.17; 95% CI 1.12–1.23; I2 = 66%) and had fewer adverse effects (RR 0.89; 95% CI 0.84–0.94; I2 = 73%) compared to the CLD. Groups using a LRD with 4L of polyethylene glycol in a single dose or a LRD with < 2000 kcal < 32 g of fibres/day had better tolerability. Conclusion Based on these findings, our recommendation is strong in favour of a LRD for bowel preparation of patients undergoing a scheduled colonoscopy. This diet could also be useful as a preoperative colonic preparation, but this requires further research. © The Author(s), under exclusive licence to Springer Science+Business Media, LLC, part of Springer Nature 2021 |
collection_details |
GBV_USEFLAG_A SYSFLAG_A GBV_SPRINGER GBV_ILN_11 GBV_ILN_20 GBV_ILN_22 GBV_ILN_23 GBV_ILN_24 GBV_ILN_31 GBV_ILN_32 GBV_ILN_39 GBV_ILN_40 GBV_ILN_60 GBV_ILN_62 GBV_ILN_63 GBV_ILN_69 GBV_ILN_70 GBV_ILN_73 GBV_ILN_74 GBV_ILN_90 GBV_ILN_95 GBV_ILN_100 GBV_ILN_101 GBV_ILN_105 GBV_ILN_110 GBV_ILN_120 GBV_ILN_138 GBV_ILN_150 GBV_ILN_151 GBV_ILN_152 GBV_ILN_161 GBV_ILN_170 GBV_ILN_171 GBV_ILN_187 GBV_ILN_213 GBV_ILN_224 GBV_ILN_230 GBV_ILN_250 GBV_ILN_267 GBV_ILN_281 GBV_ILN_285 GBV_ILN_293 GBV_ILN_370 GBV_ILN_602 GBV_ILN_636 GBV_ILN_702 GBV_ILN_711 GBV_ILN_2001 GBV_ILN_2003 GBV_ILN_2004 GBV_ILN_2005 GBV_ILN_2006 GBV_ILN_2007 GBV_ILN_2008 GBV_ILN_2009 GBV_ILN_2010 GBV_ILN_2011 GBV_ILN_2014 GBV_ILN_2015 GBV_ILN_2020 GBV_ILN_2021 GBV_ILN_2025 GBV_ILN_2026 GBV_ILN_2027 GBV_ILN_2031 GBV_ILN_2034 GBV_ILN_2037 GBV_ILN_2038 GBV_ILN_2044 GBV_ILN_2048 GBV_ILN_2049 GBV_ILN_2050 GBV_ILN_2055 GBV_ILN_2056 GBV_ILN_2057 GBV_ILN_2059 GBV_ILN_2061 GBV_ILN_2064 GBV_ILN_2065 GBV_ILN_2068 GBV_ILN_2093 GBV_ILN_2106 GBV_ILN_2107 GBV_ILN_2108 GBV_ILN_2110 GBV_ILN_2113 GBV_ILN_2118 GBV_ILN_2129 GBV_ILN_2143 GBV_ILN_2144 GBV_ILN_2147 GBV_ILN_2153 GBV_ILN_2188 GBV_ILN_2190 GBV_ILN_2232 GBV_ILN_2336 GBV_ILN_2446 GBV_ILN_2470 GBV_ILN_2472 GBV_ILN_2507 GBV_ILN_2522 GBV_ILN_2548 GBV_ILN_4035 GBV_ILN_4037 GBV_ILN_4046 GBV_ILN_4112 GBV_ILN_4125 GBV_ILN_4126 GBV_ILN_4242 GBV_ILN_4246 GBV_ILN_4249 GBV_ILN_4251 GBV_ILN_4305 GBV_ILN_4306 GBV_ILN_4307 GBV_ILN_4313 GBV_ILN_4322 GBV_ILN_4323 GBV_ILN_4324 GBV_ILN_4326 GBV_ILN_4328 GBV_ILN_4333 GBV_ILN_4334 GBV_ILN_4335 GBV_ILN_4336 GBV_ILN_4338 GBV_ILN_4393 GBV_ILN_4700 |
container_issue |
6 |
title_short |
Efficacy and tolerability of a low-residue diet for bowel preparation: systematic review and meta-analysis |
url |
https://dx.doi.org/10.1007/s00464-021-08703-8 |
remote_bool |
true |
author2 |
Pereyra, Lisandro Galvarini, Martín Mella, José Gómez, Estanislao Pedreira, Silvia C. Cimmino, Daniel G. |
author2Str |
Pereyra, Lisandro Galvarini, Martín Mella, José Gómez, Estanislao Pedreira, Silvia C. Cimmino, Daniel G. |
ppnlink |
254909620 |
mediatype_str_mv |
c |
isOA_txt |
false |
hochschulschrift_bool |
false |
doi_str |
10.1007/s00464-021-08703-8 |
up_date |
2024-07-04T01:10:32.414Z |
_version_ |
1803608845102088192 |
fullrecord_marcxml |
<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim"><record><leader>01000caa a22002652 4500</leader><controlfield tag="001">SPR046949739</controlfield><controlfield tag="003">DE-627</controlfield><controlfield tag="005">20230507175118.0</controlfield><controlfield tag="007">cr uuu---uuuuu</controlfield><controlfield tag="008">220510s2021 xx |||||o 00| ||eng c</controlfield><datafield tag="024" ind1="7" ind2=" "><subfield code="a">10.1007/s00464-021-08703-8</subfield><subfield code="2">doi</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-627)SPR046949739</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(SPR)s00464-021-08703-8-e</subfield></datafield><datafield tag="040" ind1=" " ind2=" "><subfield code="a">DE-627</subfield><subfield code="b">ger</subfield><subfield code="c">DE-627</subfield><subfield code="e">rakwb</subfield></datafield><datafield tag="041" ind1=" " ind2=" "><subfield code="a">eng</subfield></datafield><datafield tag="100" ind1="1" ind2=" "><subfield code="a">Ahumada, Cristian</subfield><subfield code="e">verfasserin</subfield><subfield code="0">(orcid)0000-0002-4640-7856</subfield><subfield code="4">aut</subfield></datafield><datafield tag="245" ind1="1" ind2="0"><subfield code="a">Efficacy and tolerability of a low-residue diet for bowel preparation: systematic review and meta-analysis</subfield></datafield><datafield tag="264" ind1=" " ind2="1"><subfield code="c">2021</subfield></datafield><datafield tag="336" ind1=" " ind2=" "><subfield code="a">Text</subfield><subfield code="b">txt</subfield><subfield code="2">rdacontent</subfield></datafield><datafield tag="337" ind1=" " ind2=" "><subfield code="a">Computermedien</subfield><subfield code="b">c</subfield><subfield code="2">rdamedia</subfield></datafield><datafield tag="338" ind1=" " ind2=" "><subfield code="a">Online-Ressource</subfield><subfield code="b">cr</subfield><subfield code="2">rdacarrier</subfield></datafield><datafield tag="500" ind1=" " ind2=" "><subfield code="a">© The Author(s), under exclusive licence to Springer Science+Business Media, LLC, part of Springer Nature 2021</subfield></datafield><datafield tag="520" ind1=" " ind2=" "><subfield code="a">Background Colorectal cancer (CRC) contributes significantly to cancer mortality worldwide. In an effort to reduce the risk of death, detection of polyps through colonoscopy is crucial. The success of the colonoscopy depends on the diet administered the day before the test. Our aim was to evaluate the efficacy, tolerability, and adverse effects of bowel preparation when using a low-residual diet (LRD) compared to a clear-liquid diet (CLD) the day before a scheduled colonoscopy. Methods PubMed/Medline, Embase, the Cochrane Central Register of Controlled Trials (CENTRAL) and Scopus databases were searched. We included studies of patients undergoing a scheduled colonoscopy for CRC screening and surveillance or for diagnostic purposes that compared a LRD with a CLD the day before the colonoscopy. Efficacy, the primary outcome, was evaluated as the rate of adequate bowel preparation. Secondary outcomes were tolerability and adverse effects of bowel preparation. Results Thirteen RCTs (N = 2587) were included. Patients receiving a LRD compared to a CLD showed no difference in adequate bowel preparations (RR 1.02; 95% CI 0.99–1.05; I2 = 60%). However, the LRD improved patient tolerability (RR 1.17; 95% CI 1.12–1.23; I2 = 66%) and had fewer adverse effects (RR 0.89; 95% CI 0.84–0.94; I2 = 73%) compared to the CLD. Groups using a LRD with 4L of polyethylene glycol in a single dose or a LRD with < 2000 kcal < 32 g of fibres/day had better tolerability. Conclusion Based on these findings, our recommendation is strong in favour of a LRD for bowel preparation of patients undergoing a scheduled colonoscopy. This diet could also be useful as a preoperative colonic preparation, but this requires further research.</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Pereyra, Lisandro</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Galvarini, Martín</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Mella, José</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Gómez, Estanislao</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Pedreira, Silvia C.</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Cimmino, Daniel G.</subfield><subfield code="4">aut</subfield></datafield><datafield tag="773" ind1="0" ind2="8"><subfield code="i">Enthalten in</subfield><subfield code="t">Surgical endoscopy and other interventional techniques</subfield><subfield code="d">New York, NY : Springer, 1987</subfield><subfield code="g">36(2021), 6 vom: 01. Sept., Seite 3858-3875</subfield><subfield code="w">(DE-627)254909620</subfield><subfield code="w">(DE-600)1463171-4</subfield><subfield code="x">1432-2218</subfield><subfield code="7">nnns</subfield></datafield><datafield tag="773" ind1="1" ind2="8"><subfield code="g">volume:36</subfield><subfield code="g">year:2021</subfield><subfield code="g">number:6</subfield><subfield code="g">day:01</subfield><subfield code="g">month:09</subfield><subfield code="g">pages:3858-3875</subfield></datafield><datafield tag="856" ind1="4" ind2="0"><subfield code="u">https://dx.doi.org/10.1007/s00464-021-08703-8</subfield><subfield code="z">lizenzpflichtig</subfield><subfield code="3">Volltext</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_USEFLAG_A</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">SYSFLAG_A</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_SPRINGER</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_11</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_20</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_22</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_23</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_24</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_31</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_32</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_39</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_40</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_60</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_62</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_63</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_69</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_70</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_73</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_74</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_90</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_95</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_100</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_101</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_105</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_110</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_120</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_138</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_150</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_151</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_152</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_161</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_170</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_171</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_187</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_213</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_224</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_230</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_250</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_267</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_281</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_285</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_293</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_370</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_602</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_636</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_702</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_711</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2001</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2003</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2004</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2005</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2006</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2007</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2008</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2009</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2010</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2011</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2014</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2015</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2020</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2021</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2025</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2026</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2027</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2031</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2034</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2037</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2038</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2044</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2048</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2049</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2050</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2055</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2056</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2057</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2059</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2061</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2064</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2065</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2068</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2093</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2106</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2107</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2108</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2110</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2113</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2118</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2129</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2143</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2144</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2147</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2153</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2188</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2190</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2232</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2336</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2446</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2470</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2472</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2507</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2522</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2548</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4035</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4037</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4046</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4112</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4125</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4126</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4242</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4246</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4249</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4251</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4305</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4306</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4307</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4313</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4322</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4323</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4324</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4326</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4328</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4333</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4334</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4335</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4336</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4338</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4393</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4700</subfield></datafield><datafield tag="951" ind1=" " ind2=" "><subfield code="a">AR</subfield></datafield><datafield tag="952" ind1=" " ind2=" "><subfield code="d">36</subfield><subfield code="j">2021</subfield><subfield code="e">6</subfield><subfield code="b">01</subfield><subfield code="c">09</subfield><subfield code="h">3858-3875</subfield></datafield></record></collection>
|
score |
7.400589 |